Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 388(22): 2037-2048, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36876756

RESUMEN

BACKGROUND: Data from a 5-year follow-up of outcomes after transcatheter edge-to-edge repair of severe mitral regurgitation, as compared with outcomes after maximal doses of guideline-directed medical therapy alone, in patients with heart failure are now available. METHODS: We randomly assigned patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy to undergo transcatheter edge-to-edge repair plus receive medical therapy (device group) or to receive medical therapy alone (control group) at 78 sites in the United States and Canada. The primary effectiveness end point was all hospitalizations for heart failure through 2 years of follow-up. The annualized rate of all hospitalizations for heart failure, all-cause mortality, the risk of death or hospitalization for heart failure, and safety, among other outcomes, were assessed through 5 years. RESULTS: Of the 614 patients enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of hospitalization for heart failure through 5 years was 33.1% per year in the device group and 57.2% per year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.41 to 0.68). All-cause mortality through 5 years was 57.3% in the device group and 67.2% in the control group (hazard ratio, 0.72; 95% CI, 0.58 to 0.89). Death or hospitalization for heart failure within 5 years occurred in 73.6% of the patients in the device group and in 91.5% of those in the control group (hazard ratio, 0.53; 95% CI, 0.44 to 0.64). Device-specific safety events within 5 years occurred in 4 of 293 treated patients (1.4%), with all the events occurring within 30 days after the procedure. CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite guideline-directed medical therapy, transcatheter edge-to-edge repair of the mitral valve was safe and led to a lower rate of hospitalization for heart failure and lower all-cause mortality through 5 years of follow-up than medical therapy alone. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079.).


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
2.
Circ J ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38852997

RESUMEN

BACKGROUND: Age-related changes in left ventricular (LV) structure and function lower the threshold for the onset of heart failure with preserved ejection fraction (HFpEF). LV parameters change also with race; however, the racial differences in age-related changes in LV parameters with and without adjustment for body mass index (BMI), heart rate (HR), and blood pressure (BP) remain unclear.Methods and Results: We performed a subanalysis of the World Alliance Society of Echocardiography Normal Values Study, an international cross-sectional study that examined normal echocardiographic values in 15 countries. The age-related changes in 2-dimensional echocardiographic derived parameters including LV size, systolic function, and mass, were compared between healthy Japanese (n=227) and healthy White (n=98) and Black (n=69) American participants. In men, age-related changes in all parameters did not differ significantly among races. However, compared with Japanese women, White American women had a smaller body surface area (BSA)-indexed LV volume, BSA-indexed LV internal dimension at end-systole, BSA-indexed LV stroke volume, and LV mass index to BSA, and a larger LV ejection fraction with age, even after adjusting for BMI, HR, and BP. CONCLUSIONS: Age-related changes in LV structure and function, which are important for the pathophysiology of HFpEF, may differ by race. Therefore, future studies examining echocardiographic reference values for each age group in each race are needed.

3.
Echocardiography ; 40(3): 188-195, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36621915

RESUMEN

BACKGROUND: Assessment of left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) plays a key role in the diagnosis of cardiac amyloidosis (CA). However, manual measurements are time consuming and prone to variability. We aimed to assess whether fully automated artificial intelligence (AI) calculation of LVEF and GLS provide similar estimates and can identify abnormalities in agreement with conventional manual methods, in patients with pre-clinical and clinical CA. METHODS: We identified 51 patients (age 80 ± 10 years, 53% male) with confirmed CA according to guidelines, who underwent echocardiography before and/or at the time of CA diagnosis (median (IQR) time between observations 3.87 (1.93, 5.44 years). LVEF and GLS were quantified from the apical 2- and 4-chamber views using both manual and fully automated methods (EchoGo Core 2.0, Ultromics). Inter-technique agreement was assessed using linear regression and Bland-Altman analyses and two-way ANOVA. The diagnostic accuracy and time for detecting abnormalities (defined as LVEF ≤ 50% and GLS ≥ -15.1%, respectively) using AI was assessed by comparisons to manual measurements as a reference. RESULTS: There were no significant differences in manual and automated LVEF and GLS values in either pre-CA (p = .791 and p = .105, respectively) or at diagnosis (p = .463 and p = .722). The two methods showed strong correlation on both the pre-CA (r = .78 and r = .83) and CA echoes (r = .74 and r = .80) for LVEF and GLS, respectively. The sensitivity and specificity of AI-derived indices for detecting abnormal LVEF were 83% and 86%, respectively, in the pre-CA echo and 70% and 79% at CA diagnosis. The sensitivity and specificity of AI-derived indices for detecting abnormal GLS was 82% and 86% in the pre-CA echo and 100% and 67% at the time of CA diagnosis. There was no significant difference in the relationship between LVEF (p = .99) and GLS (p = .19) and time to abnormality between the two methods. CONCLUSION: Fully automated AI-calculated LVEF and GLS are comparable to manual measurements in patients pre-CA and at the time of CA diagnosis. The widespread implementation of automated LVEF and GLS may allow for more rapid assessment in different disease states with comparable accuracy and reproducibility to manual methods.


Asunto(s)
Amiloidosis , Disfunción Ventricular Izquierda , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Función Ventricular Izquierda , Volumen Sistólico , Inteligencia Artificial , Reproducibilidad de los Resultados , Tensión Longitudinal Global , Valor Predictivo de las Pruebas
4.
Echocardiography ; 40(5): 388-396, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37062026

RESUMEN

INTRODUCTION: Cardiac involvement seems to impact prognosis of COVID-19, especially in critically ill patients. We aimed to assess the prognostic value of right ventricular (RV) and left ventricular (LV) dysfunction, evaluated by bedside triage echocardiography (echo), in patients admitted to emergency departments (ED) in the US with COVID-19. We also assessed the feasibility of using cloud imaging for sharing and interpreting echocardiograms. METHODS: Patients admitted to three reference EDs with confirmed COVID-19 underwent triage echo within 72 h of symptom onset with remote interpretation. Clinical and laboratory data, as well as COVID-19 symptoms, were collected. The association between echo variables, demographics and clinical data with all-cause hospital mortality and intensive care unit (ICU) admission was assessed using logistic regression. RESULTS: Three hundred ninety-nine patients were enrolled, 41% women, with a mean age of 62±16 years. Mean oxygen saturation on presentation was 92.3± 9.2%. Compared to in-hospital survivors, non-survivors were older, had lower oxygen saturation on presentation, were more likely to have a chronic condition and had lower LV ejection fraction (50.3±19.7% vs. 58.0±13.6%) (P < .05). In the cohort, 101 (25%) patients had moderate/severe LV dysfunction, 131 (33%) had moderate/severe RV dysfunction. Advanced age and lower oxygen saturation were independently associated with death and ICU admission. LV and RV function, or other echo variables, were not independent predictors of outcomes. CONCLUSION: In patients admitted with COVID-19 undergoing early echo triage, the independent predictors of death and ICU admission were age and oxygen saturation. The inclusion of echo variables did not improve prediction of unfavorable outcomes.


Asunto(s)
COVID-19 , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Triaje , Función Ventricular Izquierda , Ecocardiografía , Estudios Retrospectivos
5.
Circulation ; 143(18): 1754-1762, 2021 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-33820423

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. METHODS: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. RESULTS: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA2DS2-VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% (P<0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% (P<0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. CONCLUSIONS: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02702271.


Asunto(s)
Apéndice Atrial/fisiopatología , Anciano , Humanos , Estudios Prospectivos , Resultado del Tratamiento
6.
Circulation ; 144(6): 426-437, 2021 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-34039025

RESUMEN

BACKGROUND: In the randomized COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation), among 614 patients with heart failure with 3+ or 4+ secondary mitral regurgitation (MR), transcatheter mitral valve repair (TMVr) with the MitraClip reduced MR, heart failure hospitalizations, and mortality and improved quality of life compared with guideline-directed medical therapy (GDMT) alone. We aimed to examine the prognostic relationship between MR reduction and outcomes after TMVr and GDMT alone. METHODS: Outcomes in COAPT between 30 days and 2 years were examined on the basis of the severity of residual MR at 30 days. RESULTS: TMVr-treated patients had less severe residual MR at 30 days than GDMT-treated patients (0/1+, 2+, and 3+/4+: 72.9%, 19.9%, and 7.2% versus 8.2%, 26.1%, and 65.8%, respectively [P<0.0001]). The rate of composite death or heart failure hospitalizations between 30 days and 2 years was lower in patients with 30-day residual MR of 0/1+ and 2+ compared with patients with 30-day residual MR of 3+/4+ (37.7% versus 49.5% versus 72.2%, respectively [P<0.0001]). This relationship was consistent in the TMVr and GDMT arms (Pinteraction=0.92). The improvement in Kansas City Cardiomyopathy Questionnaire score from baseline to 30 days was maintained between 30 days and 2 years in patients with 30-day MR ≤2+ but deteriorated in those with 30-day MR 3+/4+ (-0.3±1.7 versus -9.4±4.6 [P=0.0008]) consistently in both groups (Pinteraction=0.95). CONCLUSIONS: In the COAPT trial, reduced MR at 30 days was associated with greater freedom from death or heart failure hospitalizations and improved quality of life through 2-year follow-up whether the MR reduction was achieved by TMVr or GDMT. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01626079.


Asunto(s)
Insuficiencia Cardíaca/epidemiología , Insuficiencia de la Válvula Mitral/epidemiología , Calidad de Vida , Cateterismo Cardíaco , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Prótesis Valvulares Cardíacas , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/terapia , Evaluación de Resultado en la Atención de Salud , Pronóstico , Vigilancia en Salud Pública , Ensayos Clínicos Controlados Aleatorios como Asunto , Índice de Severidad de la Enfermedad , Factores de Tiempo
7.
N Engl J Med ; 381(8): 739-748, 2019 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-31433921

RESUMEN

BACKGROUND: The role of assessment of myocardial viability in identifying patients with ischemic cardiomyopathy who might benefit from surgical revascularization remains controversial. Furthermore, although improvement in left ventricular function is one of the goals of revascularization, its relationship to subsequent outcomes is unclear. METHODS: Among 601 patients who had coronary artery disease that was amenable to coronary-artery bypass grafting (CABG) and who had a left ventricular ejection fraction of 35% or lower, we prospectively assessed myocardial viability using single-photon-emission computed tomography, dobutamine echocardiography, or both. Patients were randomly assigned to undergo CABG and receive medical therapy or to receive medical therapy alone. Left ventricular ejection fraction was measured at baseline and after 4 months of follow-up in 318 patients. The primary end point was death from any cause. The median duration of follow-up was 10.4 years. RESULTS: CABG plus medical therapy was associated with a lower incidence of death from any cause than medical therapy alone (182 deaths among 298 patients in the CABG group vs. 209 deaths among 303 patients in the medical-therapy group; adjusted hazard ratio, 0.73; 95% confidence interval, 0.60 to 0.90). However, no significant interaction was observed between the presence or absence of myocardial viability and the beneficial effect of CABG plus medical therapy over medical therapy alone (P = 0.34 for interaction). An increase in left ventricular ejection fraction was observed only among patients with myocardial viability, irrespective of treatment assignment. There was no association between changes in left ventricular ejection fraction and subsequent death. CONCLUSIONS: The findings of this study do not support the concept that myocardial viability is associated with a long-term benefit of CABG in patients with ischemic cardiomyopathy. The presence of viable myocardium was associated with improvement in left ventricular systolic function, irrespective of treatment, but such improvement was not related to long-term survival. (Funded by the National Institutes of Health; STICH ClinicalTrials.gov number, NCT00023595.).


Asunto(s)
Puente de Arteria Coronaria , Corazón/fisiología , Isquemia Miocárdica/cirugía , Volumen Sistólico , Anciano , Ecocardiografía de Estrés , Femenino , Estudios de Seguimiento , Corazón/diagnóstico por imagen , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Am J Med Genet A ; 188(5): 1448-1456, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35092149

RESUMEN

Spontaneous coronary artery dissection (SCAD) is a potential precipitant of myocardial infarction and sudden death for which the etiology is poorly understood. Mendelian vascular and connective tissue disorders underlying thoracic aortic disease (TAD), have been reported in ~5% of individuals with SCAD. We therefore hypothesized that patients with TAD are at elevated risk for SCAD. We queried registries enrolling patients with TAD to define the incidence of SCAD. Of 7568 individuals enrolled, 11 (0.15%) were found to have SCAD. Of the sequenced cases (9/11), pathogenic variants were identified (N = 9), including COL3A1 (N = 3), FBN1 (N = 2), TGFBR2 (N = 2), TGFBR1 (N = 1), and PRKG1 (N = 1). Individuals with SCAD had an increased frequency of iliac artery dissection (25.0% vs. 5.1%, p = 0.047). The prevalence of SCAD among individuals with TAD is low. The identification of pathogenic variants in genes previously described in individuals with SCAD, particularly those underlying vascular Ehlers-Danlos, Marfan syndrome, and Loeys-Dietz syndrome, is consistent with prior reports from clinical SCAD series. Further research is needed to identify specific genetic influences on SCAD risk.


Asunto(s)
Anomalías de los Vasos Coronarios , Síndrome de Ehlers-Danlos , Síndrome de Loeys-Dietz , Enfermedades Vasculares , Anomalías de los Vasos Coronarios/epidemiología , Anomalías de los Vasos Coronarios/genética , Síndrome de Ehlers-Danlos/genética , Predisposición Genética a la Enfermedad , Humanos , Síndrome de Loeys-Dietz/complicaciones , Síndrome de Loeys-Dietz/epidemiología , Síndrome de Loeys-Dietz/genética , Factores de Riesgo , Enfermedades Vasculares/congénito , Enfermedades Vasculares/epidemiología , Enfermedades Vasculares/genética
9.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34505737

RESUMEN

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/etiología , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Lancet ; 396(10252): 669-683, 2020 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-32593323

RESUMEN

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Mortalidad , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/terapia , Anciano , Anciano de 80 o más Años , Australia , Transfusión Sanguínea , Causas de Muerte , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/terapia , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/terapia , Diálisis Renal , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Estados Unidos
11.
Breast Cancer Res Treat ; 185(3): 863-868, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33400034

RESUMEN

PURPOSE: HER2-targeted therapies are associated with cardiotoxicity which is usually asymptomatic and reversible. We report the updated cardiac safety assessment of patients with compromised heart function receiving HER2-targeted therapy for breast cancer, enrolled in the SAFE-HEaRt trial, at a median follow-up of 3.5 years. METHODS: Thirty patients with stage I-IV HER2-positive breast cancer receiving trastuzumab with or without pertuzumab, or ado-trastuzumab emtansine (T-DM1), with asymptomatic LVEF (left ventricular ejection fraction) 40-49%, were started on cardioprotective medications, with the primary endpoint being completion of HER2-targeted therapy without cardiac events (CE) or protocol-defined asymptomatic worsening of LVEF. IRB-approved follow-up assessment included 23 patients. RESULTS: Median follow-up as of June 2020 is 42 months. The study met its primary endpoint with 27 patients (90%) completing their HER2-targeted therapies without cardiac issues. Of the 23 evaluable patients at long-term f/u, 14 had early stage breast cancer, and 9 had metastatic disease, 8 of whom remained on HER2-targeted therapies. One patient developed symptomatic heart failure with no change in LVEF. There were no cardiac deaths. The mean LVEF improved to 52.1% from 44.9% at study baseline, including patients who remained on HER2-targeted therapy, and those who received prior anthracyclines. CONCLUSIONS: Long-term follow-up of the SAFE-HEaRt study continues to provide safety data of HER2-targeted therapy use in patients with compromised heart function. The late development of cardiac dysfunction is uncommon and continued multi-disciplinary oncologic and cardiac care of patients is vital for improved patient outcomes.


Asunto(s)
Neoplasias de la Mama , Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/tratamiento farmacológico , Femenino , Estudios de Seguimiento , Humanos , Receptor ErbB-2/genética , Volumen Sistólico , Trastuzumab/efectos adversos , Función Ventricular Izquierda
12.
Am Heart J ; 237: 25-33, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33713618

RESUMEN

BACKGROUND: Previous studies from the Low Risk TAVR (LRT) trial demonstrated that transcatheter aortic valve replacement (TAVR) is safe and feasible in low-risk patients, with excellent 30-day and 1-year outcomes. The objective of this study was to report clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration (SVD) 2 years after TAVR. METHODS: The LRT trial was the first Food and Drug Administration-approved Investigational Device Exemption trial in the United States to evaluate the safety and feasibility of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis (AS). Valve hemodynamics and SVD by echo were recorded 30 days, 1 year, and 2 years post-TAVR. RESULTS: The LRT trial enrolled 200 low-risk patients to receive TAVR. Their mean age was 73.6 years and 61.5% were men. At 2-year follow-up, the mortality rate was 4.2%; the cardiovascular death rate was 1.6%. The disabling stroke rate was 1.1%, permanent pacemaker implantation rate was 8.6%, and 4 patients (2.2%) presented with endocarditis (2 between years 1 and 2). Of the 14% of TAVR subjects who had evidence of HALT at 30 days, there was no impact on valve hemodynamics, endocarditis or stroke at 2 years. CONCLUSIONS: TAVR for low-risk patients with symptomatic severe tricuspid AS is safe at 2 years. The presence of HALT at 30 days did not impact the early hemodynamic improvements nor the durability of the valve structure.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía , Estudios de Factibilidad , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
13.
Echocardiography ; 38(5): 752-759, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33835611

RESUMEN

BACKGROUND: Pericardial effusion drainage in patients with significant pulmonary hypertension (PH) has been questioned because of hemodynamic collapse concern, mainly because of right ventricular (RV) function challenging assessment. We aimed to assess RV function changes related to pericardiocentesis in patients with and without PH. METHODS: Consecutive patients with symptomatic moderate-to-large pericardial effusion who had either echocardiographic or clinical signs of cardiac tamponade and who underwent pericardiocentesis from 2013 to 2018 were included. RV speckle-tracking echocardiography analysis was performed before and after pericardiocentesis. Patients were stratified by significant PH (pulmonary artery systolic pressure [PASP] ≥50 mm Hg). RESULTS: The study cohort consisted of 76 patients, 23 (30%) with PH. In patients with PH, both end-diastolic and end-systolic areas (EDA, ESA) increased significantly after pericardiocentesis (22.6 ± 8.0 cm2 -26.4 ± 8.4 cm2 , P = .01) and (15.9 ± 6.3 cm2 -18.7 ± 6.5 cm2 , P = .02), respectively. However, RV function indices including fractional area change (FAC: 30.6 ± 13.7%-29.1 ± 8.8%, P = .61) and free-wall longitudinal strain (FWLS: -16.7 ± 6.7 to -15.9 ± 5.0, P = .50) remained unchanged postpericardiocentesis. In contrast, in the non-PH group, after pericardiocentesis, EDA increased significantly (20.4 ± 6.2-22.4 ± 5.9 cm2 , P = .006) but ESA did not (14.9 ± 5.7 vs 15.0 ± 4.6 cm2 , P = .89), and RV function indices improved (FAC 27.9 ± 11.7%-33.1 ± 8.5%, P = .003; FWLS -13.6 ± 5.4 to -17.2 ± 3.9%, P < .001). CONCLUSION: Quantification of RV size and function can improve understanding of echocardiographic and hemodynamic changes postpericardiocentesis, which has the potential to guide management of PH patients with large pericardial effusion.


Asunto(s)
Hipertensión Pulmonar , Disfunción Ventricular Derecha , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/diagnóstico por imagen , Pericardiocentesis , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Función Ventricular Derecha
14.
Curr Opin Cardiol ; 35(5): 464-473, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32649357

RESUMEN

PURPOSE OF REVIEW: Functional mitral regurgitation (FMR) is a complex condition in which significant mitral regurgitation coexist with cardiomyopathy and heart failure and carries an increased risk for associated morbidity and mortality. In addition to guideline-directed medical therapy and cardiac resynchronization therapy, percutaneous transcatheter mitral valve repair (TMVr) is a new therapeutic option but requires careful selection of the proper candidates. We describe the different mechanisms of functional mitral regurgitation, review echocardiographic parameters to assess its severity, and discuss recently published relevant studies including TMVr. RECENT FINDINGS: Two randomized controlled trials assessing the efficacy and safety of TMVr using the MitraClip in patients with heart failure and severe functional mitral regurgitation were published: MITRA-FR (Percutaneous Repair with the MitraClip Device for Severe Functional/Secondary Mitral Regurgitation) and COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation). The results of these trials were opposite: although MITRA-FR failed to show clinical benefit, COAPT showed a dramatic clinical and echocardiographic benefit from transcatheter mitral valve repair using the MitraClip device. We discuss these two important trials and how differences in patient enrollment could explain the discrepant results and the manner they may influence future studies and clinical practice. SUMMARY: Patients with FMR receiving optimal guideline-directed medical therapy and cardiac resynchronization therapy who meet specific clinical and echocardiographic criteria can benefit from transcatheter mitral valve repair.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Ecocardiografía , Insuficiencia Cardíaca/cirugía , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Evaluación de Resultado en la Atención de Salud , Resultado del Tratamiento
15.
Circulation ; 137(24): 2557-2567, 2018 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-29530883

RESUMEN

BACKGROUND: Comparative echocardiographic data on transcatheter aortic valve replacement systems from randomized trials are limited. The REPRISE III trial (Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Randomized Clinical Evaluation) is a multicenter, randomized comparison of a mechanically expanded (Lotus) versus self-expanding (CoreValve) transcatheter aortic valve replacement device. This analysis rigorously assesses Doppler-derived valve hemodynamics and the impact on outcomes at 1 year in patients with extreme/high surgical risk treated with Lotus and CoreValve from REPRISE III. METHODS: REPRISE III includes patients with extreme- and high-risk aortic stenosis. Patients were enrolled at 55 centers. All transthoracic echocardiograms with Doppler were obtained following a standard protocol up to 12 months postimplant and analyzed by a core laboratory. Valve size, mean gradient, aortic valve area, and Doppler velocity index and their impact on clinical outcomes are reported. Additional parameters including paravalvular leak were evaluated using a multiparametric approach. RESULTS: A total of 912 patients were randomly assigned (2:1 ratio; 607 Lotus:305 CoreValve). Median age was 84 years, 51% of the patients were women, and the Society of Thoracic Surgeons score was 6.8±4.1. CoreValve demonstrated lower gradients and larger aortic valve area and Doppler velocity index than Lotus at discharge; the difference decreased in subsequent follow-up up to a year (all P<0.01). Lotus had lower rates of paravalvular leak that persisted over time (P<0.05). Similar outcomes were seen when comparing each valve type by size group (small, medium, large). The hemodynamic differences between valves did not translate into worse clinical outcomes. All-cause mortality was not different between the 2 groups in any of the 3 valve sizes. When comparing patients with normal valve gradients (<20 mm Hg, n=780) with those with abnormal gradients (>20 mm Hg, n=48) in the entire patient population, all-cause mortality was not different. This was also not significant when evaluating each valve type separately. Similarly, there were no differences for aortic valve area >1.1 cm2 or <1.1 cm2 and for Doppler velocity index >0.35 or <0.35 (all P=not significant). CONCLUSIONS: Lotus had significantly greater freedom from moderate or severe paravalvular leak and smaller valve area and higher gradients than CoreValve. The hemodynamic differences were not associated with any clinical differences in the composite end point of mortality, disabling stroke, and moderate paravalvular leak or with quality of life at 1 year of follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Hemodinámica , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
16.
Catheter Cardiovasc Interv ; 93(4): 707-712, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30280469

RESUMEN

OBJECTIVES: The aim of this study was to determine the prognostic value of contractile reserve (CR) at baseline in patients with low-flow, low-gradient severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients with severe AS, left ventricular dysfunction, and low transaortic gradient are at high risk for mortality during surgical aortic valve replacement (SAVR). Furthermore, patients without CR have been shown to have perioperative mortality comparable to that of patients treated medically for severe AS. METHODS: We retrospectively analyzed patients who underwent TAVR with a diagnosis of low-gradient severe AS (mean transvalvular aortic gradient < 40 mmHg, LVEF < 50%, and AVA ≤ 1.0 cm2 or AVAi ≤ 0.6 cm2 ) and who had a pre-TAVR dobutamine stress echocardiogram (DSE). Patients were stratified by the presence or absence of CR, defined as an increase in stroke volume ≥ 20% during DSE. RESULTS: From 2008 to 2016, 61 patients with low-gradient severe AS underwent TAVR and had pre-TAVR DSE. CR was present in 31 patients (51%) and absent in 30 (49%). There was no significant difference between the two groups in baseline demographics, medical history, access site, or types of valves. All-cause mortality was similar in both groups at 30 days (13% with CR vs 10% without CR, P = 1.00) and 1 year (29% with CR vs 33% without CR, HR 1.20, 95% CI 0.49-2.96, P = 0.69). CONCLUSION: In patients with low-flow, low-gradient severe AS undergoing TAVR, the presence or absence of CR does not predict all-cause mortality at 30 days or 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Hemodinámica , Contracción Miocárdica , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Masculino , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad
17.
N Engl J Med ; 373(21): 2015-24, 2015 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-26436963

RESUMEN

BACKGROUND: A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. METHODS: We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]). RESULTS: Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007). CONCLUSIONS: Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars-Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.).


Asunto(s)
Anticoagulantes/uso terapéutico , Válvula Aórtica/fisiopatología , Bioprótesis/efectos adversos , Enfermedades de las Válvulas Cardíacas/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/etiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Ataque Isquémico Transitorio/etiología , Masculino , Sistema de Registros , Accidente Cerebrovascular/etiología
18.
J Vasc Surg ; 68(2): 364-371, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29567025

RESUMEN

OBJECTIVE: Endovascular repair in patients with connective tissues disorders is not recommended because of concern for repair failure. The aim of this study was to investigate thoracic endovascular aortic repair (TEVAR) outcomes in patients with confirmed or suspected syndromic and nonsyndromic genetically triggered thoracic aortic dissection. METHODS: We analyzed data for patients with descending thoracic aorta (DTA) dissection treated with TEVAR from the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). Enrolled patients had confirmed (syndromic or familial) or suspected genetically triggered thoracic aortic disease. The latter group includes patients with sporadic aortic dissection presenting at 50 years of age or younger in the absence of a family history or syndromic features. RESULTS: Between 2006 and 2014, there were 371 patients with DTA dissection enrolled in GenTAC. TEVAR was performed in 31 cases (58.1% male; median age, 47 years; range, 21.3-65.6 years). Genetically triggered aortic dissection was confirmed in 18 cases, and an additional 13 cases had suspected genetically triggered dissection because of early onset of presentation. TEVAR was performed in nine patients with type A aortic dissection: five in conjunction with acute type A dissection repair and four in the chronic phase to treat aneurysmal degeneration of the residual dissected DTA (median interval to TEVAR, 2.1 years). TEVAR was also performed in 22 cases of type B aortic dissection (TBAD), 12 acute and 10 chronic (median interval to TEVAR, 1.6 years). There were no perioperative deaths. Median follow-up for all cases was 2 years (range, 0.4 month-7 years). Reinterventions after TEVAR were performed in 13 cases (41.9%). This included urgent repair of three retrograde ascending aorta dissections occurring after TEVAR for acute TBAD (25%) and seven thoracoabdominal repairs with stent graft explantation (22.6%) at a median of 7 months after TEVAR (range, 1-16.6 months). CONCLUSIONS: TEVAR in patients with genetically triggered aortic dissections can be lifesaving in the acute setting though associated with high risk of retrograde aortic dissection in acute TBAD. For chronic dissection-related DTA aneurysmal degeneration, TEVAR could potentially be lifesaving in patients deemed too high risk for open surgical repair. Close postoperative surveillance is required, given the risk of subsequent device failure and need for reintervention. Because these circumstances are rare, multicenter prospective enrollment of patients with genetically triggered aortic disease is essential to delineate the indications for and risks of TEVAR in this heterogeneous population.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Enfermedad Aguda , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/genética , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/genética , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Femenino , Predisposición Genética a la Enfermedad , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Sistema de Registros , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto Joven
19.
Oncologist ; 22(5): 518-525, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28314836

RESUMEN

BACKGROUND: Human epidermal growth receptor 2 (HER2) targeted therapies have survival benefit in adjuvant and metastatic HER2 positive breast cancer but are associated with cardiac dysfunction. Current U.S. Food and Drug Administration recommendations limit the use of HER2 targeted agents to patients with normal left ventricular (LV) systolic function. METHODS: The objective of the SAFE-HEaRt study is to evaluate the cardiac safety of HER2 targeted therapy in patients with HER2 positive breast cancer and mildly reduced left ventricular ejection fraction (LVEF) with optimized cardiac therapy. Thirty patients with histologically confirmed HER2 positive breast cancer (stage I-IV) and reduced LVEF (40% to 49%) who plan to receive HER2 targeted therapy for ≥3 months will be enrolled. Prior to initiation on study, optimization of heart function with beta-blockers and angiotensin converting enzyme inhibitors will be initiated. Patients will be followed by serial echocardiograms and cardiac visits during and 6 months after completion of HER2 targeted therapy. Myocardial strain and blood biomarkers, including cardiac troponin I and high-sensitivity cardiac troponin T, will be examined at baseline and during the study. DISCUSSION: LV dysfunction in patients with breast cancer poses cardiac and oncological challenges and limits the use of HER2 targeted therapies and its oncological benefits. Strategies to prevent cardiac dysfunction associated with HER2 targeted therapy have been limited to patients with normal LVEF, thus excluding patients who may receive the highest benefit from those strategies. SAFE-HEaRt is the first prospective pilot study of HER2 targeted therapies in patients with reduced LV function while on optimized cardiac treatment that can provide the basis for clinical practice changes. The Oncologist 2017;22:518-525 IMPLICATIONS FOR PRACTICE: Human epidermal growth receptor 2 (HER2) targeted therapies have survival benefit in adjuvant and metastatic HER2 positive breast cancer but are associated with cardiac dysfunction. To our knowledge, SAFE-HEaRt is the first clinical trial that prospectively tests the hypothesis that HER2 targeted therapies may be safely administered in patients with mildly reduced cardiac function in the setting of ongoing cardiac treatment and monitoring. The results of this study will provide cardiac safety data and inform consideration of clinical practice changes in patients with HER2 positive breast cancer and reduced cardiac function, as well as provide information regarding cardiovascular monitoring and treatment in this population.


Asunto(s)
Neoplasias de la Mama/tratamiento farmacológico , Cardiotoxicidad/fisiopatología , Receptor ErbB-2/genética , Trastuzumab/efectos adversos , Disfunción Ventricular Izquierda/fisiopatología , Ado-Trastuzumab Emtansina , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Inhibidores de la Enzima Convertidora de Angiotensina/administración & dosificación , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/efectos adversos , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Cardiotoxicidad/complicaciones , Ecocardiografía , Femenino , Corazón/efectos de los fármacos , Corazón/fisiopatología , Humanos , Maitansina/administración & dosificación , Maitansina/efectos adversos , Maitansina/análogos & derivados , Persona de Mediana Edad , Terapia Molecular Dirigida , Estadificación de Neoplasias , Trastuzumab/administración & dosificación , Troponina I/sangre , Troponina T/sangre , Disfunción Ventricular Izquierda/sangre , Disfunción Ventricular Izquierda/inducido químicamente
20.
Am Heart J ; 184: 141-147, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28224928

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction was shown to be associated with adverse outcomes in a variety of cardiac patients and is considered a risk factor for adverse outcome according to the updated Valve Academic Research Consortium criteria. OBJECTIVE: Our goal was to assess the impact of RV function at baseline on 1-year mortality among patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: All patients with severe AS treated with TAVR from May 2007 to March 2015 at our center were included in the present study, and baseline and procedural characteristics were recorded for each patient. The patients were categorized according to RV function at baseline as assessed by current guidelines, and a comparison of mortality rates up to 1 year was performed. RESULTS: Among 650 patients, 606 had adequate echocardiogram quality and 146 (24%) had RV dysfunction. There were significant differences between the 2 groups, as patients with RV dysfunction were younger (81±9 vs 84±7 years, P=.01) and were more likely to be male (65% vs 42%, P<.001). In addition, patients with RV dysfunction had higher rates of prior myocardial infarction (26% vs 16%, P=.02) and atrial fibrillation (51% vs 39%, P=.02). Echocardiographic parameters demonstrated higher rates of left ventricular ejection fraction <40% (40% vs 18%, P<.001), tricuspid regurgitation above moderate (16% vs 9%, P=.04), and higher pulmonary artery systolic pressure (50±17 vs 44±16 mm Hg, P<.001) among patients with severe AS and RV dysfunction compared with patients with normal RV function. Despite the unfavorable cardiac function, patients with severe AS undergoing TAVR have similar functional class (P=.22) and mortality rates at 1year (27% vs 23%, log-rank P=.45). CONCLUSIONS: Patients with severe AS and RV dysfunction have similar 1-year mortality and functional class after TAVR to patients with normal RV function. The presence of RV dysfunction does not correlate with outcome in patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Derecha/fisiopatología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía , Femenino , Humanos , Masculino , Mortalidad , Pronóstico , Estudios Prospectivos , Volumen Sistólico , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA