Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37387689

RESUMEN

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Femenino , Humanos , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Estudios Retrospectivos , Resultado del Tratamiento
2.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Artículo en Francés | MEDLINE | ID: mdl-38231094

RESUMEN

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Asunto(s)
Síndrome Coronario Agudo , Cardiología , Endocarditis , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia
3.
J Cardiovasc Electrophysiol ; 34(6): 1395-1404, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37232426

RESUMEN

AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Taquicardia Ventricular , Tetralogía de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Joven , Persona de Mediana Edad , Femenino , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/complicaciones , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
4.
Europace ; 25(4): 1458-1466, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36857597

RESUMEN

AIMS: Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. METHODS AND RESULTS: Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). CONCLUSION: The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Electrocardiografía/métodos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Arritmias Cardíacas/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Función Ventricular Izquierda
5.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37115434

RESUMEN

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Corazón , Frecuencia Cardíaca , Ablación por Catéter/métodos , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 33(8): 1687-1693, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35637606

RESUMEN

INTRODUCTION: Systematic and quantitative descriptions of vein of Marshall (VOM)-induced tissue ablation are lacking. We sought to characterize the distribution of low voltage observed in the left atrium (LA) after VOM ethanol infusion. METHODS AND RESULTS: The distribution of ethanol-induced low voltage was evaluated by comparing high-density maps performed before and after VOM ethanol infusion in 114 patients referred for atrial fibrillation ablation. The two most frequently impacted segments were the inferior portion of the ridge (82.5%) and the first half of the mitral isthmus (pulmonary vein side) (92.1%). Low-voltage absence in these typical areas resulted from inadvertent ethanol infusion in the left atrial appendage vein (n = 3), initial VOM dissection (n = 3), or a "no branches" VOM morphology (n = 1). Visible anastomosis of the VOM with roof or posterior veins more frequently resulted in low-voltage extension beyond typical areas, toward the entire left antrum (19.0% vs. 1.9%, p = .0045) or the posterior LA (39.7% vs. 3.8%, p < .001) but with a limited positive predictive value ranging from 29.4% to 43.5%. Ethanol-induced low voltage covered a median LA surface of 3.6% (1.9%-5.0%) and did not exceed 8% of the LA surface in 90% of patients. CONCLUSION: VOM ethanol infusion typically locates at the inferior ridge and the adjacent half of the mitral isthmus. Low-voltage extensions can be anticipated but not guaranteed by the presence of visible anastomosis of the VOM with roof or posterior veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Etanol/efectos adversos , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/cirugía
7.
J Cardiovasc Electrophysiol ; 32(3): 588-594, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33537996

RESUMEN

INTRODUCTION: Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx™ is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report. METHODS: To compare the POLARx™ cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO™ (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx™ were enrolled. Data were prospectively gathered. POLARx™ patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP. RESULTS: Seventy patients were analyzed, 20 in POLARx™, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA2 DS2 -VASc 1, left-atrium size 34 ml/m², and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx™ vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx™ group (90 min vs. 60 min, p < .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx™ and AFAP groups, respectively. Despite equal TTI, the POLARx™ had a lower minimal temperature reached (-57°C vs -47°C, p < .001). CONCLUSION: The novel POLARx™ cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Tecnología , Resultado del Tratamiento
8.
Heart Rhythm ; 21(6): 828-835, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38286245

RESUMEN

BACKGROUND: Differentiating between atypical atrioventricular nodal reentrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia utilizing a septal accessory pathway is a complex challenge. OBJECTIVE: The purpose of this study was to describe the "local VA index," a straightforward method based on signals from the coronary sinus catheter, to distinguish between these arrhythmias during tachycardia and entrainment. The ventriculoatrial (VA) interval on the coronary sinus catheter is measured during tachycardia and entrainment, at the site of earliest atrial activity. The difference between these 2 situations defines the "local VA index." We also propose a mechanism to clarify the limitations of historical pacing maneuvers, such as postpacing interval minus tachycardia cycle length (PPI-TCL) and stimulus-atrial interval minus ventriculoatrial interval (SA-VA), by examining nodal decrement and intraventricular conduction delay. METHODS: In a retrospective study of 75 patients referred for supraventricular tachycardia evaluation, 37 were diagnosed with atrioventricular reentrant tachycardia (AVRT) with orthodromic reciprocating tachycardia, and 38 with AVNRT (27 typical, 11 atypical). RESULTS: In comparison to AVRT patients, AVNRT patients exhibited longer PPI-TCL (176 ± 47 ms vs 113 ± 42 ms; P <.01) and SA-VA (138 ± 47 ms vs 64 ± 28 ms; P <.01). The AVRT group had mean local VA index of -1 ± 13 ms, whereas the AVNRT group had a significantly longer index of 91 ± 46 ms (P <.01). An optimal threshold for differentiation was a local VA index of 40 ms. Importantly, there was no significant correlation between pacing cycle length and nodal decrement as well as intraventricular delay related to pathway location. This interindividual variability might explain misleading interpretations of PPI-TCL and SA-VA. CONCLUSION: This novel approach is advantageous because of its simplicity and effectiveness, requiring only 2 diagnostic catheters. A local VA interval difference <40 ms provides a clear distinction for AVRT.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Supraventricular , Humanos , Diagnóstico Diferencial , Femenino , Masculino , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Persona de Mediana Edad , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Electrocardiografía/métodos , Adulto , Sistema de Conducción Cardíaco/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/fisiopatología
9.
J Clin Med ; 13(19)2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39407972

RESUMEN

Currently, pulmonary vein isolation (PVI) is the gold standard in catheter ablation for atrial fibrillation (AF). However, PVI alone may be insufficient in the management of persistent AF, and complementary methods are being explored. One such method takes an anatomical approach-improving both its success rate and lesion durability may lead to improved treatment outcomes. An additional approach complementary to the anatomical one is also attracting attention, one that focuses on epicardial conduction. This involves ethanol ablation of the vein of Marshall (VOM) and can be very effective in blocking epicardial conduction related to Marshall structure; it is becoming incorporated into standard treatment. However, the pitfall of this "Marshall-PLAN", a method that combines an anatomical approach with ethanol infusion within the VOM (Et-VOM), is that Et-VOM and other line creations are not always successfully completed. This has led to cases of AF and/or atrial tachycardia (AT) recurrence even after completing this lesion set. Investigating effective adjunctive methods will enable us to complete the lesion set with the aim to lower the rates of recurrence of AF and/or AT in the future.

10.
J Clin Med ; 12(19)2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37834932

RESUMEN

Over the last few years, pacing of the conduction system (CSP) has emerged as the new standard pacing modality for bradycardia indications, allowing a more physiological ventricular activation compared to conventional right ventricular pacing. CSP has also emerged as an alternative modality to conventional biventricular pacing for the delivery of cardiac resynchronization therapy (CRT) in heart failure patients. However, if the initial clinical data seem to support this new physiological-based approach to CRT, the lack of large randomized studies confirming these preliminary results prevents CSP from being used routinely in clinical practice. Furthermore, concerns are still present regarding the long-term performance of pacing leads when employed for CSP, as well as their extractability. In this review article, we provide the state-of-the-art of CSP as an alternative to biventricular pacing for CRT delivery in heart failure patients. In particular, we describe the physiological concepts supporting this approach and we discuss the future perspectives of CSP in this context according to the implant techniques (His bundle pacing and left bundle branch area pacing) and the clinical data published so far.

11.
Artículo en Inglés | MEDLINE | ID: mdl-37783852

RESUMEN

BACKGROUND: A novel method to measure atrial fibrillation cycle length (AF-CL) was recently described, based on the average of 10 consecutive signals (FARS10). FARS10 accurately identified pulmonary vein isolation (PVI)-responders among patients with persistent AF. Whether this method is applicable to patients with paroxysmal AF is unknown. OBJECTIVE: The aim of this study is to evaluate the prognostic value of FARS10 measurements in patients with paroxysmal AF. METHODS AND RESULTS: We enrolled paroxysmal AF patients undergoing PVI in a prospective multicenter study. After AF induction with a standardized protocol, the AF-CL was measured using FARS-10 method. The primary endpoint was AF/AT-recurrence. One-hundred and four patients were included (61 ± 14 years, 25% females). After a mean follow-up of 12 ± 4 months, AF/AT recurrence rate was 20%. The fastest PV CL (fPV-CL) was independently associated with the primary endpoint at multivariate analysis (HR 1.02, p < 0.001). Every 10 ms increase in fPV-CL, AF recurrences increased by 20%. The value of 160 ms was found to be the optimal cut-off (specificity 81%, sensitivity 76%). Patients with fPV-CL < 160 ms experienced lower AF recurrences as compared to patients with fPV-CL > 160 ms (8% vs. 32% at 1 year; HR = 0.17, p < 0.001). Progression to persistent AF was observed in 13% of patients with fPV-CL > 160 ms. CONCLUSION: fPV-CL measured with the FARS-10 method accurately predicts PVI success in paroxysmal AF patients undergoing PVI. Patients with slow PV activity (fPV-CL > 160 ms) experience higher AF recurrence rate after PVI and more frequent progression to persistent AF. In 104 patients with paroxysmal atrial fibrillation (AF) undergoing AF ablation, AF was induced at the beginning of the procedure. Pulmonary vein activity was measured using FARS10 measurement (10 consecutive fastest atrial repetitive similar morphology signals). The value of 160 ms was found to be the best cut-off to discriminate outcomes. At 1-year follow-up, patients with fast veins (< 160 ms) experienced significantly fewer AF recurrences as compared to patients with slow veins (> 160 ms). PV activity measured with FARS10 method accurately discriminates pulmonary vein isolation responders, in patients with paroxysmal AF. ABBREVIATIONS: AF atrial fibrillation, AT atrial tachycardia, CL cycle length, FARS10: 10 consecutive fastest atrial repetitive similar morphology signal, fPV fastest pulmonary vein, HR hazard ratio, ms milliseconds.

12.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37414109

RESUMEN

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

13.
Heart Rhythm ; 20(1): 14-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36115541

RESUMEN

BACKGROUND: Beyond pulmonary vein (PV) isolation, anatomic isthmus transection is an adjunctive strategy for persistent atrial fibrillation. Data on the durability of multiple lines of block remain scarce. OBJECTIVE: The purpose of this study was to evaluate the impact of gaps within such a lesion set. METHODS: We followed 291 consecutive patients who underwent (1) vein of Marshall ethanol infusion, (2) PV isolation, and (3) mitral, cavotricuspid, and dome isthmus transection. Dome transection relied on 2 distinct strategies over time: a single roof line with touch-ups applied in case of gap demonstrated by conventional maneuvers (first leg), and an alternative floor line if the roof line exhibited a gap during high-density mapping with careful electrogram reannotation (second leg). RESULTS: Twelve-month sinus rhythm maintenance was 70% after 1 procedure and 94% after 1 or 2 procedures. Event-free survival after the first procedure was lower in case of residual gaps within the lesion set (log-rank, P = .004). Delayed gaps were found in 94% of a second procedure performed in the 69 patients relapsing despite a complete lesion set with PV gaps increasing the risk of recurrence of atrial fibrillation (67% vs 34%; P = .02) and anatomic isthmus gaps supporting a majority of atrial tachycardias (60%). Between the first leg and the second leg, a significant decrease was found in roof lines considered blocked during the first procedure (99% vs 78%; P < .001) and in delayed dome gaps observed during a second procedure (68% vs 43%; P = .05). CONCLUSION: Gaps are arrhythmogenic and can be reduced by optimized ablation and assessment of lines of block. Closing these gaps improves sinus rhythm maintenance.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
14.
Am J Cardiol ; 166: 45-52, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34961604

RESUMEN

Etiologic factors and long-term outcomes of catheter ablation of atrial fibrillation (AF) in young patients have not been well characterized. This study aimed to analyze the etiologic factors and outcomes of pulmonary vein isolation (PVI) in patients with young-onset AF (young-AF, defined as having first documented episode <45 years). Consecutive patients with young-AF undergoing PVI (n = 197) in 2 academic centers were enrolled and followed for 36.1 ± 24.5 months. A control group of patients with AF onset ≥45 years (n = 554) was included. The most frequent risk factors in young-AF were intensive exercise (25%), moderate-to-heavy alcohol consumption (23%), and familial AF (22%). Compared with patients with AF onset ≥45-year, patients with young-AF were more often men (82% vs 66%, p <0.001), had more frequently paroxysmal AF (81% vs 60%, p <0.001), had less left atrial dilatation (40.9 ± 6.2 mm vs 44.2 ± 7.2 mm, p <0.001), and had lower 4-year recurrence rate after last PVI procedure (22% vs 45%, p <0.001). In young-AF, structural heart disease (SHD) was the only independent predictor of recurrence. Patients with young-AF selected to undergo cryoballoon (CB) ablation were younger (35.0 ± 7.7 vs 36.6 ± 6.7 years, p = 0.035) and had less persistent AF (6% vs 24%, p = 0.004) and coronary artery disease (2% vs 7%, p = 0.02) compared with radiofrequency ablation. After excluding patients with persistent AF and SHD, there was no difference in single procedural success between radiofrequency or CB PVI (27% vs 17%, p = 0.11). In conclusion, patients with young-AF have diverse etiologies and high single and multiprocedural PVI successes. SHD is the only independent predictor of recurrence. In patients with young-AF, there is a selection bias for CB ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Cardiopatías , Venas Pulmonares , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Cardiopatías/etiología , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
15.
Biomolecules ; 12(8)2022 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-36008935

RESUMEN

Arrhythmogenic cardiomyopathy (ACM) is a rare inherited disorder, whose genetic cause is elusive in about 50-70% of cases. ACM presents a variable disease course which could be influenced by genetics. We performed next-generation sequencing on a panel of 174 genes associated with inherited cardiovascular diseases on 82 ACM probands (i) to describe and classify the pathogenicity of rare variants according to the American College of Medical Genetics and Genomics both for ACM-associated genes and for genes linked to other cardiovascular genetic conditions; (ii) to assess, for the first time, the impact of common variants on the ACM clinical disease severity by genotype-phenotype correlation and survival analysis. We identified 15 (likely) pathogenic variants and 66 variants of uncertain significance in ACM-genes and 4 high-impact variants in genes never associated with ACM (ABCC9, APOB, DPP6, MIB1), which deserve future consideration. In addition, we found 69 significant genotype-phenotype associations between common variants and clinical parameters. Arrhythmia-associated polymorphisms resulted in an increased risk of arrhythmic events during patients' follow-up. The description of the genetic framework of our population and the observed genotype-phenotype correlation constitutes the starting point to address the current lack of knowledge in the genetics of ACM.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Arritmias Cardíacas/genética , Displasia Ventricular Derecha Arritmogénica/genética , Displasia Ventricular Derecha Arritmogénica/patología , Estudios de Asociación Genética , Humanos , Fenotipo
16.
J Clin Med ; 11(7)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35407408

RESUMEN

A radiofrequency energy lesion transmurality marker incorporating power, contact force, and time (Ablation Index, AI) was shown to be associated with outcomes of catheter ablation (CA) of multiple arrhythmias, but was never systematically assessed in the CA of focal atrial tachycardias (AT). We aimed to evaluate the role of AI as a predictor of outcomes in focal AT CA, and therefore, retrospectively included 45 consecutive patients undergoing CA for focal AT in four referral electrophysiology laboratories. Clinical and procedural information were collected. For each patient, maximum and mean (by averaging maximum AI values for each radiofrequency ablation lesion) AI were measured. The primary outcome was focal AT-free survival, and was systematically assessed with periodical Holter monitors or cardiac implantable electronic devices. CA was acutely effective in each case; however, 20% (n = 9) of the study population experienced a focal AT recurrence over a median follow-up of 288 days. Both maximum and mean AI values were significantly higher among patients without AT recurrences (maximum AI = 568 ± 91, mean AI = 426 ± 105) than in patients with AT relapses (maximum AI = 447 ± 142, mean AI = 352 ± 76, p = 0.036, and p = 0.028, respectively). The optimal cutoffs associated with freedom from recurrences were 461 for maximum AI (sensitivity, 0.89; specificity, 0.56) and 301 for mean AI (sensitivity, 0.97; specificity, 0.44). In a time-to-event analysis, maximum AI was significantly associated with survival free from AT recurrence (p = 0.001), whereas mean AI was not (p = 0.08). In summary, maximum AI is the best procedural parameter associated with the outcomes of CA for focal AT, and may help standardize the procedural approach.

17.
Heart Rhythm ; 19(5): 701-709, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35033665

RESUMEN

BACKGROUND: An understanding of normal atrial activation during sinus rhythm can inform catheter ablation strategies to avoid deleterious impacts of ablation lesions on atrial conduction and mechanics. OBJECTIVE: The purpose of this study was to describe how the sinus node impulse originates, propagates, and collides in right and left atria with normal voltage. METHODS: Fifty consecutive patients undergoing catheter ablation of atrial fibrillation with endocardial atrial voltage >0.5 mV during high-density 3-dimensional mapping were studied. RESULTS: Sinus node exits varied among patients along a lateral oblique arc extending from the anterior aspect of the superior vena cava (SVC) to the mid-posterior wall of the right atrium (RA). Conduction slowing or block at one of the smooth components that faces the crista terminalis was observed in 54% of cases, including complete block at the SVC musculature and systemic venous sinus in 6% of cases. Depending on these 2 key features of RA activation, interatrial conduction was mediated by the Bachmann bundle (64%) and posterior bundles (54%), with an overlap of the resulting left atrial breakthrough location. Wavefront collision was consistently observed at 3 sites: the septal aspect of the cavotricuspid isthmus, and the lower aspects of the dome and of the mitral isthmus. CONCLUSION: During sinus rhythm, atrial activation occurs via distinct sequences mediated by a complex interaction of anatomic factors.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Humanos , Nodo Sinoatrial , Vena Cava Superior/patología
18.
JACC Case Rep ; 3(11): 1373-1375, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34505074

RESUMEN

Differential diagnosis of wide complex tachycardia in patients taking anti-arrhythmic can be challenging. Conventional ECG diagnostic criteria are poorly specific and should be applied with caution. Patients who develop life-threatening arrhythmias after flecainide infusion should be screened for Brugada Syndrome, especially if concomitant sinus node dysfunction is present. (Level of Difficulty: Intermediate.).

19.
Front Cardiovasc Med ; 8: 688351, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34395558

RESUMEN

Chronic myelomonocytic leukemia (CMML) is a clonal hematopoietic stem cell disorder with overlapping myelodysplastic and myeloproliferative features. The disease is generally characterized by blood monocytosis, bone marrow dysplasia, cytopenia, and hepatosplenomegaly. While malignant blood diseases are frequently associated with a high risk of thromboembolism, CMML is often accompanied by immune-mediated hemorrhagic diathesis. Indeed, very few reports in literature report thrombotic complications of CMML patients. We will briefly present here the case of a patient with CMML who developed a massive right atrial thrombus. We aim to highlight the non-negligible thrombotic burden of the disease, and we will get through the differential diagnosis of right atrial masses and the management of right atrial thrombi, which are a rare and poorly known entity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA