Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Int J Legal Med ; 136(5): 1273-1279, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35147732

RESUMEN

From March 13 until May 31, 2020, a complete lockdown in Turkey was planned and implemented by the government of Turkey. The vulnerable population with substance use disorders was affected more than others due to the social isolation measures meant to control the pandemic. This study presents detailed and broad data on drug abuse in suspected cases during the first wave of the COVID-19 pandemic in Turkey and compares the frequencies and patterns of drug abuse before and during the pandemic. The samples were screened by liquid chromatography-high resolution mass spectrometry and liquid chromatography-tandem mass spectrometry. Blood and urine samples of suspected users (n = 9669) were analyzed for drugs of abuse during the first wave of the COVID-19 pandemic and compared with their results (n = 8727) obtained just before the COVID-19 pandemic. The use of party drugs, such as MDMA and cocaine, and the classic illicit drug cannabis was significantly decreased and followed the same trend after complete lockdown was over. In contrast, methamphetamine use increased significantly during the lockdown period and continued after the lockdown. Interestingly, the number of tests that were positive for pregabalin as a misused licit drug increased, and this increase continued after the lockdown. The results showed a significant increase in drug abuse cases and changes in drug abuse trends, with an alteration toward more easily obtainable and lower-priced drugs. Using more dangerous and easily available licit and illicit drugs may cause serious health problems.


Asunto(s)
COVID-19 , Consumidores de Drogas , Drogas Ilícitas , Trastornos Relacionados con Sustancias , Control de Enfermedades Transmisibles , Humanos , Drogas Ilícitas/análisis , Pandemias , Detección de Abuso de Sustancias/métodos , Trastornos Relacionados con Sustancias/epidemiología , Turquía/epidemiología
2.
Echocardiography ; 39(12): 1631-1634, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36354015

RESUMEN

Untreated severe mitral regurgitation (MR) is associated with poor outcomes due to the adverse consequences of long-standing volume overload on the left ventricle and left atrium, which leads to pulmonary hypertension and right-sided heart failure. Early intervention results in favorable long-term outcomes making appropriate timing of intervention very critical. We present a 53-year-old male with severe symptomatic MR and right sided-heart failure which progressed to cardiac cirrhosis necessitating enrollment to the liver transplant list. Transcatheter mitral valve repair (TMVR) using MitraClip implantation resulted in impressive clinical improvement and resolution of cirrhosis. Eventually, the patient was taken off the transplant list. Treatment of severe MR may lead to improvements in congestive hepatopathy.


Asunto(s)
Trasplante de Hígado , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
3.
Catheter Cardiovasc Interv ; 97(5): 912-916, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33197110

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) using Watchman device has become a world-wide, well-established therapeutic alternative to chronic systemic oral anticoagulation in patient who are at high-risk of bleeding with paroxysmal (PAF) or chronic atrial fibrillation (Afib). Currently, LAAO procedures are performed under general anesthesia (GA) and patients stay overnight post procedure in the United States. We aimed to present the effectiveness and safety of same day discharge following LAAO under moderate conscious sedation (MCS) in patients without procedural complications. METHODS: A total of 112 patients between August 2019 and May 2020 with elevated CHA2 DS2 VASc (median score of 3) underwent transesophageal echocardiography (TEE)-guided LAAO with FDA approved Watchman (Boston Scientific, MN) under MCS and discharged home on the same day 6 hr following their post procedural transthoracic echocardiogram (TTE) evaluations. All patients had next day TTE and follow up at the cardiology clinic. We prospectively evaluated clinical and procedural outcomes using medical records of these patients. RESULTS: Among all the patients, the mean age was 83.5 ± 8.5 years, 45 (40%) were women. Procedural duration, device implant time and fluoroscopic times were 45 ± 8.6, 14.5 ± 7.8 and 10.2 ± 1.2 min, respectively. The median required dosage of propofol was 105 ± 2.8 mg. No complications arose from MCS. There was no need for conversion to GA in any of the patients during the procedure. All patients were able to be discharged 6 hr following their TTE evaluation post procedure. There were no procedural complications. CONCLUSIONS: Same day discharge following LAAO closure seems to be safe and effective in patients without procedural complications. LAAO can also be performed safely and effectively under moderate conscious sedation. Applying moderate conscious sedation may simplify the LAAO procedure, reduce procedural time, procedural costs and hospital stay while increasing overall patient satisfaction.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/efectos adversos , Sedación Consciente/efectos adversos , Ecocardiografía Transesofágica , Femenino , Humanos , Alta del Paciente , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 94(6): 820-826, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-30938045

RESUMEN

OBJECTIVES: To evaluate the safety and efficacy of percutaneous mitral valve repair for the management of functional mitral insufficiency. BACKGROUND: Severe FMR is present in 25-30% of patients with heart failure and is an independent predictor of mortality and hospitalizations in patients with both ischemic and nonischemic cardiomyopathy. MitraClip therapy has been approved for high surgical risk patients with primary mitral regurgitation. Recent studies including two randomized trials have yielded conflicting results in terms of its clinical efficacy and outcomes for FMR. A quantitative evaluation and synthesis of this information are essential in elucidating the role of MitraClip repair for FMR. METHODS: We performed a literature search using PubMed, EMBASE, and Cochrane Central Register of Controlled Trials from September 2008 to September 2018. Studies comparing percutaneous mitral valve repair using the MitraClip device against conservative therapy for the management of functional mitral regurgitation were included. RESULTS: Seven studies with 1,174 patients in MitraClip group and 1,015 patients in medical therapy group met inclusion criteria. The 12-month mortality in the MitraClip group was 18.4% compared with 25.9% in the medical therapy group (odds ratio [OR]: 0.65 [0.50, 0.86]; p < .002). The rate of readmission at 12 months was 29.9% in the MitraClip group compared with 54.1% in the medical therapy group (OR: 040 [0.32-0.49]; p < .0001. The prognostic efficacy of MitraClip repair appears to be more substantial over longer follow-up period over medical therapy alone. CONCLUSIONS: Based on the results of this meta-analysis, percutaneous mitral valve repair with MitraClip appears to be superior to medical therapy for symptomatic moderate-to-severe functional mitral insufficiency. Further clinical research is needed to identify the ideal patient subgroups who receive maximum benefit with the MitraClip therapy.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 91(7): 1363-1364, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29894594

RESUMEN

Transcatheter aortic valve replacement is now the standard of care for severe symptomatic aortic stenosis patients who are at high-surgical risk. Percutaneous approach without a surgical cut down has been increasingly adapted by some centers in USA. Percutaneous approach seems to be associated with shorter hospital stay, similar short and late vascular complications, less disabling stroke, similar mortality as well as significantly less hospital cost. However, this technique also requires operators to be able to manage any vascular complications using advanced endovascular interventions to achieve complete hemostasis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Humanos , Factores de Riesgo
6.
Catheter Cardiovasc Interv ; 88(4): 571-581, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27029396

RESUMEN

BACKGROUND: The Occlutech Figulla ASD device series (OFSO) shows an improved device design for interventional ASD closure, larger follow-up series are missing. METHODS: We retrospectively reviewed the feasibility, safety, implantation properties, results, and follow-up of ASD closure using Occlutech devices over a 5 year period by establishing a multi-institutional collaborative result registry with 16 contributing centers from 11 countries (IRFACODE). RESULTS: In 1315 patients of all age groups (female 66.9%), successful (98%) ASD closure was performed (mean age 28.9 years, weight 52 kg, height 148.6 cm). Of the defects, 47.9% showed no or only a deficient aortic rim; in 11.9%, there was more than one defect; a septum aneurysm was present in 21.5%; and the mean implanted device size was 20.5 mm. Immediate closure was achieved in 78.6%, at discharge in 83.1%, and 96.4% and 97.3% at 6 and 12 months follow-up, respectively. During a mean follow-up of 2.7 years (in total 3597 patient years), significant complications were minimal (total = 8, <1%) with secondary device embolizations in five and AV-blocks in three patients. No erosion or death was reported. CONCLUSION: ASD closure using OFSO is feasible in a large variety of patients, safe with only a minimal risk of severe side effects and especially without any aortic erosions despite a large percentage of large and complicated defects. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Asia , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Europa (Continente) , Estudios de Factibilidad , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Lactante , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
7.
Heart Lung Circ ; 25(1): 29-34, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26166174

RESUMEN

BACKGROUND: The aim of the present study was to perform a preliminary evaluation of the potential association between platelet distribution width (PDW) and frequency of major adverse cardiovascular events (MACEs) development in an observational study of acute coronary syndrome (ACS) patients. METHODS: A total of 679 consecutive patients with ACS (498 (73.3%) males; mean age was 63.31±11.2 years; study population composed of 320 patients with acute myocardial infarction and 359 patients with unstable angina pectoris) subjected to primary percutaneous coronary intervention with transradial approach (TRA) were retrospectively enrolled to the study. Tertiles were formed based on PDW levels. The associations between PDW and in-hospital and long-term MACEs were analysed. RESULTS: The frequencies of in-hospital instent thrombosis (P=0.05), long-term instent restenosis (P=0.005) and long-term total MACEs (P=0.008) were higher in tertiles having a high PDW value. In multivariate analyses, PDW was an independent predictor of in-hospital and long-term MACEs (odds ratio 1.081, 95% confidence interval 1.003-1.165; p=0.042). The projected Kaplan-Meier incidence of a MACEs in the PDW tertiles groups were 12.8%, 12.1%, and 21.6% at 40 months (respectively, p=0.003). CONCLUSIONS: The pre-procedural PDW may be an independent predictor of both in-hospital and long-term adverse outcomes in patients with ACS.


Asunto(s)
Síndrome Coronario Agudo , Angina Inestable , Plaquetas/metabolismo , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/cirugía , Anciano , Angina Inestable/sangre , Angina Inestable/mortalidad , Angina Inestable/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/mortalidad , Infarto del Miocardio/cirugía , Estudios Retrospectivos , Tasa de Supervivencia , Trombosis/sangre , Trombosis/etiología , Trombosis/mortalidad
9.
Turk Kardiyol Dern Ars ; 52(6): 375-383, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39225646

RESUMEN

OBJECTIVE: This study aims to assess the efficacy and safety of tricuspid valve (TV) transcatheter edge-to-edge repair (TEER) procedures using the MitraClip or TriClip device in high-risk patients with severe secondary tricuspid regurgitation (TR) and provide Turkish-specific data on procedural outcomes and clinical follow-up. METHODS: This study enrolled 42 high-risk patients with severe secondary TR who underwent transcatheter edge-to-edge repair using either the MitraClip or TriClip device. Patient selection criteria included severe TR, high surgical risk (EuroScore ≥ 8 and Tricuspid Regurgitation Impact Severity Score (TRI-SCORE) ≥ 6), symptomatic despite medical therapy, and anatomical suitability for TriClip. Patients underwent rigorous evaluation by a specialized cardiac team before the procedure, including 2D/3D transesophageal echocardiography to assess eligibility. RESULTS: The study achieved a 100% procedural success rate, defined as successful implantation and at least one-degree reduction in TR severity. Post-procedure assessments revealed that 88.1% of patients had mild to moderate TR, indicating significant improvement, while only 11.9% retained severe TR. During the median follow-up of 11.5 months, rehospitalization occurred in 23.8% of patients, and mortality was observed in 7.1% of patients, demonstrating a favorable safety profile. Comparative analysis between TriClip and MitraClip devices showed similar efficacy and safety outcomes, with no significant differences in procedural durations or complication rates. CONCLUSION: The study demonstrates the effectiveness and safety of TV TEER using TriClip or MitraClip devices in managing severe secondary TR in high-risk patients. Procedure success, improved TR severity, and favorable clinical outcomes were observed, supporting the role of transcatheter techniques in TR management.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Masculino , Femenino , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Turquía , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Ecocardiografía Transesofágica , Persona de Mediana Edad , Anciano de 80 o más Años , Índice de Severidad de la Enfermedad , Implantación de Prótesis de Válvulas Cardíacas/métodos
10.
Cardiovasc Revasc Med ; 64: 21-24, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38388247

RESUMEN

BACKGROUND: With the advances in percutaneous treatment technologies, the left atrial appendage occlusion (LAAO) and the transcatheter mitral valve repair using MitraClip (TMVR) are increasingly being performed today. The SAFARI 2™ guidewire is primarily used during transcatheter aortic valve implantation (TAVI), our group has also been using it during MitraClip and LAAO procedures. Our clinical study aimed to share our data on the safety and effectiveness for the use of the SAFARI 2™ guidewire during MitraClip or LAAO procedures. METHODS: This study included a total of 1730 patients (948 patients of MitraClip and 782 of LAAO). It was designed as single arm, retrospective, and multicenter between July 2016 and August 2022. SAFARI 2™ guidewire was used exclusively during all the procedures. RESULTS: A total of 1730 patients (male 55.8 %) were included in the study. There was no guidewire-related complications, stroke/transient ischemic attack, bleeding (minor/major/life-threatening), need for cardiac surgery, pneumonia, and vascular dissection/rupture in patients undergoing LAAO. There were 2 device-related pericardial effusions without tamponade. No stroke/transient ischemic attack, bleeding (minor/major/life-threatening), mortality, need for cardiac surgery, pneumonia, guidewire-related complication, pericardial effusion, vascular dissection/rupture, or clip embolization was observed in patients undergoing MitraClip. CONCLUSIONS: By taking advantage of its pre-shaped structure, the SAFARI 2™ guidewire seems to offer a reliable and safe device delivery for both MitraClip and LAAO procedures as a regular work horse wire. Our results should be confirmed by larger randomized or prospective trials.


Asunto(s)
Apéndice Atrial , Cateterismo Cardíaco , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Factores de Riesgo , Factores de Tiempo , Diseño de Equipo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
11.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742736

RESUMEN

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Falla de Prótesis , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ecocardiografía Transesofágica , Masculino , Resultado del Tratamiento , Femenino , Anciano , Reoperación
12.
Am J Cardiol ; 211: 130-136, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38035500

RESUMEN

Radial artery occlusion (RAO) has been the most common postprocedural complication of transradial artery access. The optimal method of prevention of RAO is still lacking. In our study, we aimed to evaluate the effect of patent hemostasis on early (24 hours) and late (2 weeks) RAO prevention. The Open Radial Artery Study was a single-arm, prospective, and multicenter study. The primary end points were early and late RAO at the vascular access site after transradial coronary procedures. Secondary end points were access site hematoma, pseudoaneurysm formation, arteriovenous fistula, and nerve injury. A total of 2,181 patients were analyzed (67% male, mean age 68 years). The mean interventional duration and hemostatic times were 75.6 ± 55.6 and 60 ± 5.6 minutes, respectively. Radial artery spasm occurred in 10% of patients (n = 218). Catheter kinking, radial artery rupture, or dissection were not observed during the procedure. RAO, hematoma, pseudoaneurysm, arteriovenous fistula, or nerve damage was not observed in any of the patients in the early or late period. In patients who undergo coronary diagnostic or interventional procedures through transradial artery access, the patent hemostasis method seems a critical step in the prevention of early and late RAO.


Asunto(s)
Aneurisma Falso , Arteriopatías Oclusivas , Fístula Arteriovenosa , Humanos , Masculino , Anciano , Femenino , Arteria Radial , Estudios Prospectivos , Aneurisma Falso/epidemiología , Aneurisma Falso/etiología , Hematoma/epidemiología , Hematoma/etiología , Fístula Arteriovenosa/complicaciones , Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos
13.
Turk Kardiyol Dern Ars ; 51(4): 290-293, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37272152

RESUMEN

Transcatheter edge-to-edge repair treatment is mainly used for patients with chronic heart failure concomitant severe mitral regurgitation. However, utilization of this system in the acute seting of myocardial infarction is still limited. In this case report authors aimed to show the effectiveness of the percutaneous treatment for severe acute mitral regurgitation early after myocardial infarction.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Humanos , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Insuficiencia Cardíaca/complicaciones , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
14.
Front Cardiovasc Med ; 10: 1218158, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37663416

RESUMEN

Patent ductus arteriosus (PDA) is a common congenital heart disease affecting roughly one in every 2,000 term births. Although most of the patients are diagnosed and treated during childhood, few cases may persist into adulthood. We presented a 27-year-old male patient with a 20.2 mm diameter PDA who was referred to our hospital with progressive fatigue and exertional dyspnea. Given the potential complications, usual techniques such as coil occlusion and duct occluders were deemed inappropriate for this patient. Thoracic endovascular aortic repair (TEVAR) using a non-touch exclusion technique was successfully performed for this patient. The patient was discharged with no major post-surgical complications. TEVAR could be a new, safe, and effective alternative treatment to other transcatheter procedures for complicated PDAs in some patients.

15.
Postepy Kardiol Interwencyjnej ; 19(1): 56-63, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090209

RESUMEN

Introduction: Data on the change in mitral valve annulus diameter (MAD), and left atrial appendage (LAA) structure and function after transcatheter edge-to-edge repair (TEER) of the mitral valve in patients with secondary mitral regurgitation (MR) are lacking. Aim: To evaluate the change in these parameters just after the clip insertion and its relationship with prognosis in the long term. Material and methods: A total of 50 patients (age: 71.5 ±11.3 years, 70% male) with moderate-to-severe or severe MR were included in the study. Transthoracic (TTE) and transoesophageal echocardiography (TEE) were performed before and after the procedure. Prognostic data were recorded with post-procedure telephone calls and follow-up visits. Results: TEE performed during the procedure showed that LAA contraction and filling velocity significantly increased (p < 0.001 for all). Systolic pulmonary artery pressure (SPAP), MAD, and LAA landing zone dimension significantly decreased (p < 0.001 for all). There was only a significant correlation between the MAD before clip placement and the MAD change after clip placement (r = 0.6, p < 0.001). During a mean follow-up period of 10.5 ±8.9 months, no significant correlation was found between MAD change, LAA contraction and filling velocity change, and LAA landing zone dimension change and rehospitalization, stroke, mortality, and composite outcome. Conclusions: The contraction and filling velocity of LAA, SPAP, MAD, and LAA landing zone dimension changed significantly immediately after the MitraClip procedure. Although these parameters are not related to composite outcome in our study, MAD, LAA diameter, and velocity need to be compared between successful and unsuccessful procedures to predict their clinical relevance.

16.
Cardiovasc Revasc Med ; 47: 76-85, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36270966

RESUMEN

This review compares the recommendations of the recent 2020 American College of Cardiology (ACC)/American Heart Association (AHA) and 2021 European Society of Cardiology (ESC)/European Association for Cardio-Thoracic Surgery (EACTS) guidelines on the management of patients with valvular heart disease (VHD). ACC/AHA and ESC/EACTS guidelines are both the updated versions of previous 2017 documents. Both guidelines fundamentally agree on the extended indications of percutaneous valve interventions, the optimal use of imaging modalities other than 2D echocardiography, the importance of a multidisciplinary Heart Team as well as active patient participation in clinical decision making, more widespread use of NOACs and earlier intervention with lower left ventricular dilatation thresholds to decrease long-term mortality. The differences between the guidelines are mainly related to the classification of the severity of valve pathologies and frequency of follow-up, level of recommendations of valve intervention indications in special patient groups such as frail patients and the left ventricular diameter and ejection fraction thresholds for intervention.


Asunto(s)
Cardiología , Enfermedades de las Válvulas Cardíacas , Humanos , Estados Unidos , Administración Oral , Anticoagulantes , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/cirugía , Ecocardiografía
17.
J Invasive Cardiol ; 34(6): E481-E483, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35652712

RESUMEN

The use of simultaneous left ventricular and ascending aortic pressure tracings by cardiac catheterization is the gold standard of care for accurate hemodynamic assessment of aortic stenosis severity in patients with equivocal echocardiogram. We describe the first-in-man single radial access "double-barrel" technique for the evaluation of aortic stenosis. A 7-Fr Glidesheath Slender hydrophilic-coated introducer sheath (Terumo) was placed in the right radial artery. Two 4-Fr pigtails, 1 in the left ventricle and 1 in the ascending aorta, were advanced through the single sheath. The single radial access "double-barrel" technique is a simple way to accurately evaluate patients with aortic stenosis, avoiding multiple access sites or femoral access.


Asunto(s)
Estenosis de la Válvula Aórtica , Corazón Univentricular , Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Presión Arterial , Cateterismo Cardíaco/métodos , Humanos , Arteria Radial
18.
Turk Kardiyol Dern Ars ; 50(8): 613-616, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35976240

RESUMEN

The objective of this article is to describe a patient with hemorrhagic shock due to type 3 postendovascular aortic repair rupture successfully treated with the endurant II stent graft via a primary endovascular approach with a rapid response protocol. A 65-year-old male patient who underwent endovascular aortic repair 3 years ago was admitted to the emergency department with severe abdominal pain and hemorrhagic shock. The patient was rapidly taken to the angiography laboratory, and aortography demonstrated distal aortic graft rupture and extravasation of contrast media. The repair was performed successfully with 3 stent-grafts by paying attention to rupture localization and renal artery ostia. The hemodynamics of the patient improved very quickly, and the patient was discharged after 5 days. Emergency primary stent grafting using a rapid response protocol could be a crucial alternative to open surgery for late endoleaks, which are complicated with hemorrhagic shock.


Asunto(s)
Reparación Endovascular de Aneurismas , Choque Hemorrágico , Humanos , Anciano , Choque Hemorrágico/cirugía
19.
Eurasian J Med ; 53(2): 144-147, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34177299

RESUMEN

Ventricular septal defect (VSD) is one of the most common congenital heart diseases worldwide today. Although the majority close spontaneously, transcatheter VSD closure is a common option for symptomatic patients with suitable anatomy in adult age. Although transesophageal echocardiography (TEE) and intracardiac echocardiography are the most common imaging modalities for the procedure, in patients with poor TEE images, Transthoracic echocardiography (TTE) can be used as a reliable alternative. Here we present an adult patient with pulmonary hypertension associated with a muscular VSD which was closed percutaneously using 2-dimensional TTE because of poor TEE images.

20.
Z Naturforsch C J Biosci ; 76(9-10): 417-424, 2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34047146

RESUMEN

Although radical treatment of Alzheimer's and Parkinson's disease is not possible yet, it is aimed to slow the course of the disease and increase the life quality of individuals with the drugs used in the clinic at the present time. Successful results have been achieved in the use of cholinesterase inhibitors and monoamine oxidase inhibitors together in these neurodegenerative diseases. In this study, indane ring which are in the structure of anticholinesterase effective molecules and 2-hydrazinothiazole structure whose inhibitory activities reported on monoamine oxidase-B (MAO-B) were combined; 4-(substituted phenyl)-2-[2-(3-phenyl-2,3-dihydro-1H-inden-1-ylidene) hydrazinyl]thiazole derivatives (3a-3i) were synthesized as dual inhibitors. The structures of the compounds were verified by IR, 1H-NMR, 13C-NMR, and HRMS spectroscopy. When enzyme inhibition activities were evaluated, it was determined that the compounds 3a (42.33%) and 3d (42.39%) on acetylcholinesterase (AChE) enzyme; compounds 3g (75.42%) and 3h (60.33%) showed inhibition on MAO-B enzyme at most, at 10-3 M concentration.


Asunto(s)
Inhibidores de la Colinesterasa/farmacología , Inhibidores de la Monoaminooxidasa/farmacología , Monoaminooxidasa/efectos de los fármacos , Tiazoles/química , Humanos , Inhibidores de la Monoaminooxidasa/química , Análisis Espectral/métodos , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA