Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 4251, 2024 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-38378834

RESUMEN

Craniospinal irradiation (CSI) is a vital therapeutic approach utilized for young patients suffering from central nervous system disorders such as medulloblastoma. The task of accurately outlining the treatment area is particularly time-consuming due to the presence of several sensitive organs at risk (OAR) that can be affected by radiation. This study aimed to assess two different methods for automating the segmentation process: an atlas technique and a deep learning neural network approach. Additionally, a novel method was devised to prospectively evaluate the accuracy of automated segmentation as a knowledge-based quality assurance (QA) tool. Involving a patient cohort of 100, ranging in ages from 2 to 25 years with a median age of 8, this study employed quantitative metrics centered around overlap and distance calculations to determine the most effective approach for practical clinical application. The contours generated by two distinct methods of atlas and neural network were compared to ground truth contours approved by a radiation oncologist, utilizing 13 distinct metrics. Furthermore, an innovative QA tool was conceptualized, designed for forthcoming cases based on the baseline dataset of 100 patient cases. The calculated metrics indicated that, in the majority of cases (60.58%), the neural network method demonstrated a notably higher alignment with the ground truth. Instances where no difference was observed accounted for 31.25%, while utilization of the atlas method represented 8.17%. The QA tool results showed that the two approaches achieved 100% agreement in 39.4% of instances for the atlas method and in 50.6% of instances for the neural network auto-segmentation. The results indicate that the neural network approach showcases superior performance, and its significantly closer physical alignment to ground truth contours in the majority of cases. The metrics derived from overlap and distance measurements have enabled clinicians to discern the optimal choice for practical clinical application.


Asunto(s)
Irradiación Craneoespinal , Tomografía Computarizada por Rayos X , Humanos , Niño , Redes Neurales de la Computación , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Cancers (Basel) ; 16(3)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38339393

RESUMEN

(1) Background: Proton therapy, a precise form of radiation treatment, can be significantly affected by variations in bowel content. The purpose was to identify the most beneficial gantry angles that minimize deviations from the treatment plan quality, thus enhancing the safety and efficacy of proton therapy for Wilms' tumor patients. (2) Methods: Thirteen patients with Wilms' tumor, enrolled in the SJWT21 clinical trial, underwent proton therapy. The variations in bowel gas were systematically monitored using daily Cone Beam Computed Tomography (CBCT) imaging. Air cavities identified in daily CBCT images were analyzed to construct daily verification plans and measure water equivalent path length (WEPL) changes. A worst-case scenario simulation was conducted to identify the safest beam angles. (3) Results: The study revealed a maximum decrease in target dose (ΔD100%) of 8.0%, which corresponded to a WEPL variation (ΔWEPL) of 11.3 mm. The average reduction in target dose, denoted as mean ΔD100%, was found to be 2.8%, with a standard deviation (SD) of 3.2%. The mean ΔWEPL was observed as 3.3 mm, with an SD of 2.7 mm. The worst-case scenario analysis suggested that gantry beam angles oriented toward the patient's right and posterior aspects from 110° to 310° were associated with minimized WEPL discrepancies. (4) Conclusions: This study comprehensively evaluated the influence of bowel gas variability on treatment plan accuracy and proton range uncertainties in pediatric proton therapy for Wilms' tumor.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA