Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(2): e14157, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37820316

RESUMEN

Radioembolization using Yttrium-90 (90 Y) microspheres is widely used to treat primary and metastatic liver tumors. The present work provides minimum practice guidelines for establishing and supporting such a program. Medical physicists play a key role in patient and staff safety during these procedures. Products currently available are identified and their properties and suppliers summarized. Appropriateness for use is the domain of the treating physician. Patient work up starts with pre-treatment imaging. First, a mapping study using Technetium-99m (Tc-99m ) is carried out to quantify the lung shunt fraction (LSF) and to characterize the vascular supply of the liver. An MRI, CT, or a PET-CT scan is used to obtain information on the tumor burden. The tumor volume, LSF, tumor histology, and other pertinent patient characteristics are used to decide the type and quantity of 90 Y to be ordered. On the day of treatment, the appropriate dose is assayed using a dose calibrator with a calibration traceable to a national standard. In the treatment suite, the care team led by an interventional radiologist delivers the dose using real-time image guidance. The treatment suite is posted as a radioactive area during the procedure and staff wear radiation dosimeters. The treatment room, patient, and staff are surveyed post-procedure. The dose delivered to the patient is determined from the ratio of pre-treatment and residual waste exposure rate measurements. Establishing such a treatment modality is a major undertaking requiring an institutional radioactive materials license amendment complying with appropriate federal and state radiation regulations and appropriate staff training commensurate with their respective role and function in the planning and delivery of the procedure. Training, documentation, and areas for potential failure modes are identified and guidance is provided to ameliorate them.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Microesferas , Neoplasias Hepáticas/radioterapia , Radioisótopos de Itrio/uso terapéutico , Embolización Terapéutica/métodos , Física
2.
J Appl Clin Med Phys ; 23(5): e13565, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35226392

RESUMEN

PURPOSE: Optimization of dosimetric leaf gap (DLG) and transmission is commonly performed through a manual trial and error process, which can lead to sub-optimal values. The purpose of this work is to create an alternative automated optimization process that provides the optimal DLG and transmission pair for use in a clinical setting. METHODS: Utilizing the treatment planning system application programming interface, a phase space of clinically viable DLG and transmission pairs was generated. The phase space contained 51,051 dose planes for DLGs between 0.0  and 2.5 mm and transmission values between 0.01% and 2.5%. Thirteen plans were measured for multiple multileaf collimator types and nominal beam energies. The optimization minimized the mean γ-index and maximized the γ-index pass rate. The optimized values were validated using five plans excluded from the optimization. RESULTS: Of the nominal beam energies and multileaf collimator system (MLC)-type combinations tested, 6/7 showed an increase in γ-index pass rate and a decrease in mean γ-index signifying better agreement between measurement and calculation. When comparing the optimized DLG and transmission values to the clinically implemented values identified via an iterative method, 5/7 energy, and MLC type combinations showed no statistically significant changes. In addition, the optimized values were benchmarked against three Task Group 119 plans with published γ-index pass rates, which had been held out of the optimization. For those plans, the optimized DLG and transmission values provided the same or better γ-index pass rates. CONCLUSION: We presented a novel and viable automated alternative to current approaches of selecting the DLG and transmission parameters. This method will reduce the time required to determine the clinically acceptable DLG and transmission parameters and ensure optimality for the plans included in the optimization.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
3.
J Appl Clin Med Phys ; 22(11): 196-202, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34582118

RESUMEN

The current clinical interface for Varian's intrafraction motion review (IMR) is limited, providing only qualitative data for review at the treatment console. This study provides a method of extracting and interpreting data from combined log files for quantitative evaluation. Combined log files acquired during patient treatment and a parsing code was developed to scan the combined log file looking for unique identifiers pertaining to the data of interest. We were able to extract clinically relevant parameters from the log files including date and time, gantry angle, expected marker position, found marker position, pixel size, and detection result. This study details how to compare IMR data to Calypso investigating dual-surrogates for intrafraction monitoring during treatment for other researchers to build on these methods. Understanding data recorded during treatment within the combined log files can be helpful in quality improvement of patient care by retrospectively reviewing intrafraction motion.


Asunto(s)
Movimiento , Planificación de la Radioterapia Asistida por Computador , Humanos , Movimiento (Física) , Estudios Retrospectivos
4.
Curr Cardiol Rep ; 22(11): 151, 2020 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-32964267

RESUMEN

PURPOSE OF REVIEW: Radiation-induced cardiovascular disease, including coronary artery disease, is a well-known sequela of radiation therapy and represents a significant source of morbidity and mortality for cancer survivors. This review examines current literature and guidelines to care for this growing population of cancer survivors. RECENT FINDINGS: The development of radiation-induced ischemic heart disease following radiation can lead even to early cardiotoxicities, inclusive of coronary artery disease, which limit cancer treatment outcomes. These coronary lesions tend to be diffuse, complex, and proximal. Early detection with multimodality imaging and targeted intervention is required to minimize these risks. Early awareness, detection, and management of radiation-induced cardiovascular disease are paramount as cancer survivorship continues to grow.


Asunto(s)
Enfermedades Cardiovasculares , Isquemia Miocárdica , Neoplasias , Cardiotoxicidad , Enfermedades Cardiovasculares/etiología , Detección Precoz del Cáncer , Humanos , Isquemia Miocárdica/etiología , Neoplasias/radioterapia , Radioterapia/efectos adversos
5.
Wound Repair Regen ; 27(2): 139-149, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30576033

RESUMEN

Cutaneous wounds caused by an exposure to high doses of ionizing radiation remain a therapeutic challenge. While new experimental strategies for treatment are being developed, there are currently no off-the-shelf therapies for the treatment of cutaneous radiation injury that have been proven to promote repair of the damaged tissues. Plasma-based biomaterials are biologically active biomaterials made from platelet enriched plasma, which can be made into both solid and semi-solid forms, are inexpensive, and are available as off-the-shelf, nonrefrigerated products. In this study, the use of plasma-based biomaterials for the mitigation of acute and late toxicity for cutaneous radiation injury was investigated using a mouse model. A 2-cm diameter circle of the dorsal skin was irradiated with a single dose of 35 Gy followed by topical treatment with plasma-based biomaterial or vehicle once daily for 5 weeks postirradiation. Weekly imaging demonstrated more complete wound resolution in the plasma-based biomaterial vs. vehicle group which became statistically significant (p < 0.05) at weeks 12, 13, and 14 postmaximum wound area. Despite more complete wound healing, at 9 and 17 weeks postirradiation, there was no statistically significant difference in collagen deposition or skin thickness between the plasma-based biomaterial and vehicle groups based on Masson trichrome staining nor was there a statistically significant difference in inflammatory or fibrosis-related gene expression between the groups. Although significant improvement was not observed for late toxicity, plasma-based biomaterials were effective at promoting wound closure, thus helping to mitigate acute toxicity.


Asunto(s)
Materiales Biocompatibles/uso terapéutico , Plasma Rico en Plaquetas , Traumatismos por Radiación/patología , Traumatismos por Radiación/terapia , Piel/patología , Animales , Materiales Biocompatibles/farmacología , Análisis Costo-Beneficio , Modelos Animales de Enfermedad , Masculino , Ratones , Cicatrización de Heridas
6.
J Appl Clin Med Phys ; 19(3): 351-354, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29493079

RESUMEN

AAPM Report 142 recommends and the State of Ohio requires that the imaging dose be quantified in radiotherapy applications. Using the TG51 dose calibration protocol for MV Imaging dose measurement requires knowledge of the kQ parameter for the beam quality and the ionization chamber type under investigation. The %dd(10)x of the Varian TrueBeam 2.5 MV imaging beam falls outside the range of the available data for the calculation of the kQ value. Due to the similarities of the 2.5 MV imaging beam and the 60 Co beam, we and others made the assumption that kQ = 1.0 in TG51 calculations. In this study, we used the TG21 and TG51 calibration protocols in conjunction to validate that kQ = 1.0 for the 2.5 MV imaging beam using a PTW 30013 farmer chamber. Standard measurements for TG51 absolute dosimetry QA were performed at 100 cm SSD, 10 cm depth, 10 × 10 field size, delivering 100 Monitor Units to a waterproof Farmer Chamber (PTW TN30013) for both 2.5 and 6 MV. Both the TG21 and TG51 formalisms were used to calculate the dose to water per MU at dmax (Dw /MU) for the 6 MV beam. The calculated outputs were 1.0005 and 1.0004 cGy/MU respectively. The TG21 formalism was then used to calculate (Dw /MU) for the 2.5 MV imaging beam. This value was then used in the TG51 formalism to find kQ for the 2.5 MV imaging beam. A kQ value of 1.00 ± 0.01 was calculated for 2.5 MV using this method.


Asunto(s)
Modelos Teóricos , Fantasmas de Imagen , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Calibración , Electrones , Humanos , Fotones , Radiometría/métodos
7.
J Appl Clin Med Phys ; 19(1): 115-124, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29159920

RESUMEN

PURPOSE: To establish a streamlined end-to-end test of a 6 degrees-of-freedom (6DoF) robotic table using a 3D printed phantom for periodic quality assurance. METHODS: A 3D printed phantom was fabricated with translational and rotational offsets and an imbedded central ball-bearing (BB). The phantom underwent each step of the radiation therapy process: CT simulation in a straight orientation, plan generation using the treatment planning software, setup to offset marks at the linac, registration and corrected 6DoF table adjustments via hidden target test, delivery of a Winston-Lutz test to the BB, and verification of table positioning via field and laser lights. The registration values, maximum total displacement of the combined Winston-Lutz fields, and a pass or fail criterion of the laser and field lights were recorded. The quality assurance process for each of the three linacs were performed for the first 30 days. RESULTS: Within a 95% confidence interval, the overall uncertainty values for both translation and rotation were below 1.0 mm and 0.5° for each linac respectively. When combining the registration values and other uncertainties for all three linacs, the average deviations were within 2.0 mm and 1.0° of the designed translation and rotation offsets of the 3D print respectively. For all three linacs, the maximum total deviation for the Winston-Lutz test did not exceed 1.0 mm. Laser and light field verification was within tolerance every day for all three linacs given the latest guidance documentation for table repositioning. CONCLUSION: The 3D printer is capable of accurately fabricating a quality assurance phantom for 6DoF positioning verification. The end-to-end workflow allows for a more efficient test of the 6DoF mechanics while including other important tests needed for routine quality assurance.


Asunto(s)
Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación , Posicionamiento del Paciente , Fantasmas de Imagen , Impresión Tridimensional , Garantía de la Calidad de Atención de Salud/normas , Radioterapia de Intensidad Modulada/normas , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Programas Informáticos
8.
Radiographics ; 34(4): 1062-81, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25019442

RESUMEN

The focus of this article is radiation therapy for gynecologic cancers, with emphasis on imaging-based treatment planning and delivery. For the various gynecologic cancers, radiation oncologists rely on essential clinical information to triage treatment options, and various imaging studies are performed for treatment planning and radiation therapy delivery. A practical approach is provided to help radiologists tailor their reports for the needs of their radiation oncology and gynecologic oncology colleagues, to optimize multidisciplinary care for patients with gynecologic cancer. Template radiology reports are proposed to address the specific information needs of oncologists at each phase-before, during, and after treatment. Fueled by the rapid progress in engineering and computer sciences during the past 2 decades, remarkable advances have been made in anatomic, functional, and molecular imaging and in radiation treatment planning and delivery in patients with gynecologic cancer. Radiation therapy has evolved from a nontargeted approach to a precisely targeted, highly conformal treatment modality, to further improve treatment outcomes and reduce morbidity. High-quality imaging has become essential for staging of the disease, delineation of tumor extent for treatment planning and delivery, and monitoring therapy response. Anatomic and functional imaging has also been shown to provide prognostic information that allows clinicians to tailor therapy on the basis of personalized patient information. This field is an area of active research, and future clinical trials are warranted to validate preliminary results in the field.


Asunto(s)
Diagnóstico por Imagen , Neoplasias de los Genitales Femeninos/diagnóstico , Neoplasias de los Genitales Femeninos/radioterapia , Diagnóstico por Imagen/métodos , Técnicas de Diagnóstico Obstétrico y Ginecológico , Femenino , Humanos , Estadificación de Neoplasias , Pronóstico
9.
Med Phys ; 51(2): 786-798, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38103260

RESUMEN

BACKGROUND: The first clinical trials to assess the feasibility of FLASH radiotherapy in humans have started (FAST-01, FAST-02) and more trials are foreseen. To increase comparability between trials it is important to assure treatment quality and therefore establish a standard for machine quality assurance (QA). Currently, the AAPM TG-224 report is considered as the standard on machine QA for proton therapy, however, it was not intended to be used for ultra-high dose rate (UHDR) proton beams, which have gained interest due to the observation of the FLASH effect. PURPOSE: The aim of this study is to find consensus on practical guidelines on machine QA for UHDR proton beams in transmission mode in terms of which QA is required, how they should be done, which detectors are suitable for UHDR machine QA, and what tolerance limits should be applied. METHODS: A risk assessment to determine the gaps in the current standard for machine QA was performed by an international group of medical physicists. Based on that, practical guidelines on how to perform machine QA for UHDR proton beams were proposed. RESULTS: The risk assessment clearly identified the need for additional guidance on temporal dosimetry, addressing dose rate (constancy), dose spillage, and scanning speed. In addition, several minor changes from AAPM TG-224 were identified; define required dose rate levels, the use of clinically relevant dose levels, and the use of adapted beam settings to minimize activation of detector and phantom materials or to avoid saturation effects of specific detectors. The final report was created based on discussions and consensus. CONCLUSIONS: Consensus was reached on what QA is required for UHDR scanning proton beams in transmission mode for isochronous cyclotron-based systems and how they should be performed. However, the group discussions also showed that there is a lack of high temporal resolution detectors and sufficient QA data to set appropriate limits for some of the proposed QA procedures.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Ciclotrones , Protones , Consenso , Radiometría , Dosificación Radioterapéutica
10.
Neurosurgery ; 94(4): 797-804, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37902322

RESUMEN

BACKGROUND AND OBJECTIVES: Vertebral compression fracture (VCF) is a common, but serious toxicity of spinal stereotactic body radiotherapy (SBRT). Several variables that place patients at high risk of VCF have previously been identified, including advanced Spinal Instability Neoplastic Score (SINS), a widely adopted clinical decision criterion to assess spinal instability. We examine the role of tumoral endplate (EP) disruption in the risk of VCF and attempt to incorporate it into a simple risk stratification system. METHODS: This study was a retrospective cohort study from a single institution. Demographic and treatment information was collected for patients who received spinal SBRT between 2013 and 2019. EP disruption was noted on pre-SBRT computed tomography scan. The primary end point of 1-year cumulative incidence of VCF was assessed on follow-up MRI and computed tomography scans at 3-month intervals after treatment. RESULTS: A total of 111 patients were included. The median follow-up was 18 months. Approximately 48 patients (43%) had at least one EP disruption. Twenty patients (18%) experienced a VCF at a median of 5.2 months from SBRT. Patients with at least one EP disruption were more likely to experience VCF than those with no EP disruption (29% vs 6%, P < .001). A nomogram was created using the variables of EP disruption, a SINS of ≥7, and adverse histology. Patients were stratified into groups at low and high risk of VCF, which were associated with 2% and 38% risk of VCF ( P < .001). CONCLUSION: EP disruption is a novel risk factor for VCF in patients who will undergo spinal SBRT. A simple nomogram incorporating EP disruption, adverse histology, and SINS score is effective for quickly assessing risk of VCF. These data require validation in prospective studies and could be helpful in counseling patients regarding VCF risk and referring for prophylactic interventions in high-risk populations.


Asunto(s)
Fracturas por Compresión , Radiocirugia , Fracturas de la Columna Vertebral , Neoplasias de la Columna Vertebral , Humanos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/epidemiología , Fracturas de la Columna Vertebral/etiología , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/etiología , Fracturas por Compresión/epidemiología , Radiocirugia/efectos adversos , Radiocirugia/métodos , Estudios Prospectivos , Estudios Retrospectivos , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/patología
11.
Adv Radiat Oncol ; 8(4): 101201, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37008254

RESUMEN

Purpose: Increasing evidence suggests that ultra-high-dose-rate (UHDR) radiation could result in similar tumor control as conventional (CONV) radiation therapy (RT) while reducing toxicity to surrounding healthy tissues. Considering that radiation toxicity to gonadal tissues can cause hormone disturbances and infertility in young patients with cancer, the purpose of this study was to assess the possible role of UHDR-RT in reducing toxicity to healthy gonads in mice compared with CONV-RT. Methods and Materials: Radiation was delivered to the abdomen or pelvis of female (8 or 16 Gy) and male (5 Gy) C57BL/6J mice, respectively, at conventional (∼0.4 Gy/s) or ultrahigh (>100 Gy/s) dose rates using an IntraOp Mobetron linear accelerator. Organ weights along with histopathology and immunostaining of irradiated gonads were used to compare toxicity between radiation modalities. Results: CONV-RT and UHDR-RT induced a similar decrease in uterine weights at both studied doses (∼50% of controls), which indicated similarly reduced ovarian follicular activity. Histologically, ovaries of CONV- and UHDR-irradiated mice exhibited a comparable lack of follicles. Weights of CONV- and UHDR-irradiated testes were reduced to ∼30% of controls, and the percentage of degenerate seminiferous tubules was also similar between radiation modalities (∼80% above controls). Pairwise comparisons of all quantitative data indicated statistical significance between irradiated (CONV or UHDR) and control groups (from P ≤ .01 to P ≤ .0001) but not between radiation modalities. Conclusions: The data presented here suggest that the short-term effects of UHDR-RT on the mouse gonads are comparable to those of CONV-RT.

12.
Pract Radiat Oncol ; 13(6): 510-516, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37516957

RESUMEN

Carbon-fiber reinforced (CFR) polyetheretherketone hardware is an alternative to traditional metal hardware used for spinal fixation surgeries before postoperative radiation therapy for patients with spinal metastases. CFR hardware's radiolucency decreases metal artifact, improving visualization and accuracy of treatment planning. We present the first clinical use and proof of principle of CFR spinal hardware with tantalum markers used for successful tracking of intrafraction motion (IM) using Varian TrueBeam IMR (Intrafraction Motion Review) software module during postoperative spine stereotactic radiation. A 63-year-old woman with history of endometrial cancer presented with acute back pain. Imaging demonstrated pathologic T12 vertebral fracture with cord compression. She underwent T12 vertebrectomy with circumferential decompression and posterior instrumented T10-L2 fusion at our facility using CFR-polyetheretherketone hardware with tantalum screw markers followed by postoperative stereotactic body radiation therapy to 3000 cGy in 5 fractions delivered to T11-T12. Tantalum screw markers were used for IMR tracking. During irradiation, 260 kV images were acquired, and IMR software was able to identify and track markers. During the entire treatment, the IM motions were less than 3 mm. This is the first presented case of CFR spinal hardware with tantalum markers used for successful IMR tracking of IM during daily spine stereotactic treatment. Future work will be needed to improve workflow and create a spine-specific IMR protocol.


Asunto(s)
Radiocirugia , Femenino , Humanos , Persona de Mediana Edad , Fibra de Carbono , Tantalio/uso terapéutico , Polímeros , Polietilenglicoles , Cetonas
13.
Int J Radiat Oncol Biol Phys ; 116(5): 1202-1217, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37121362

RESUMEN

FLASH radiation therapy (FLASH-RT), delivered with ultrahigh dose rate (UHDR), may allow patients to be treated with less normal tissue toxicity for a given tumor dose compared with currently used conventional dose rate. Clinical trials are being carried out and are needed to test whether this improved therapeutic ratio can be achieved clinically. During the clinical trials, quality assurance and credentialing of equipment and participating sites, particularly pertaining to UHDR-specific aspects, will be crucial for the validity of the outcomes of such trials. This report represents an initial framework proposed by the NRG Oncology Center for Innovation in Radiation Oncology FLASH working group on quality assurance of potential UHDR clinical trials and reviews current technology gaps to overcome. An important but separate consideration is the appropriate design of trials to most effectively answer clinical and scientific questions about FLASH. This paper begins with an overview of UHDR RT delivery methods. UHDR beam delivery parameters are then covered, with a focus on electron and proton modalities. The definition and control of safe UHDR beam delivery and current and needed dosimetry technologies are reviewed and discussed. System and site credentialing for large, multi-institution trials are reviewed. Quality assurance is then discussed, and new requirements are presented for treatment system standard analysis, patient positioning, and treatment planning. The tables and figures in this paper are meant to serve as reference points as we move toward FLASH-RT clinical trial performance. Some major questions regarding FLASH-RT are discussed, and next steps in this field are proposed. FLASH-RT has potential but is associated with significant risks and complexities. We need to redefine optimization to focus not only on the dose but also on the dose rate in a manner that is robust and understandable and that can be prescribed, validated, and confirmed in real time. Robust patient safety systems and access to treatment data will be critical as FLASH-RT moves into the clinical trials.


Asunto(s)
Habilitación Profesional , Electrones , Humanos , Instituciones de Salud , Posicionamiento del Paciente , Tecnología , Dosificación Radioterapéutica
14.
Front Oncol ; 12: 912804, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35756685

RESUMEN

Background: With survival improving in many metastatic malignancies, spine metastases have increasingly become a source of significant morbidity; achieving durable local control (LC) is critical. Stereotactic body radiotherapy (SBRT) may offer improved LC and/or symptom palliation. However, due to setup concerns, SBRT is infrequently offered to patients with ≥3 contiguous involved levels. Because data are limited, we sought to evaluate the feasibility, toxicity, and cancer control outcomes of spine SBRT delivered to ≥3 contiguous levels. Methods: We retrospectively identified all SBRT courses delivered between 2013 and 2019 at a tertiary care institution for postoperative or intact spine metastases. Radiotherapy was delivered to 14-35 Gy in 1-5 fractions. Patients were stratified by whether they received SBRT to 1-2 or ≥3 contiguous levels. The primary endpoint was 1-year LC and was compared between groups. Factors associated with increased likelihood of local failure (LF) were explored. Acute and chronic toxicity was assessed. In-depth dosimetric data were collected. Results: Overall, 165 patients with 194 SBRT courses were identified [54% were men, median age was 61 years, 93% had Karnofsky Performance Status (KPS) ≥70, and median follow-up was 15 months]. One hundred thirteen patients (68%) received treatment to 1-2 and 52 to 3-7 (32%) levels. The 1-year LC was 88% (89% for 1-2 levels vs. 84% for ≥3 levels, p = 0.747). On multivariate analysis, uncontrolled systemic disease was associated with inferior LC for patients with ≥3 treated levels. No other demographic, disease, treatment, or dosimetric variables achieved significance. Rates of new/progressive fracture were equivalent (8% vs. 9.5%, p = 0.839). There were no radiation-induced myelopathy or grade 3+ acute or late toxicities in either group. Coverage of ≥95% of the planning target volume with ≥95% prescription dose was similar between groups (96% 1-2 levels vs. 89% ≥3 levels, p = 0.078). Conclusions: For patients with ≥3 contiguous involved levels, spine SBRT is feasible and may offer excellent LC without significant toxicity. Prospective evaluation is warranted.

15.
Front Oncol ; 12: 912799, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36505845

RESUMEN

Background: With advances in systemic therapy translating to improved survival in metastatic malignancies, spine metastases have become an increasingly common source of morbidity. Achieving durable local control (LC) for patients with circumferential epidural disease can be particularly challenging. Circumferential stereotactic body radiotherapy (SBRT) may offer improved LC for circumferential vertebral and/or epidural metastatic spinal disease, but prospective (and retrospective) data are extremely limited. We sought to evaluate the feasibility, toxicity, and cancer control outcomes with this novel approach to circumferential spinal disease. Methods: We retrospectively identified all circumferential SBRT courses delivered between 2013 and 2019 at a tertiary care institution for post-operative or intact spine metastases. Radiotherapy was delivered to 14-27.5 Gy in one to five fractions. Feasibility was assessed by determining the proportion of plans for which ≥95% planning target volume (PTV) was coverable by ≥95% prescription dose. The primary endpoint was 1-year LC. Factors associated with increased likelihood of local failure (LF) were explored. Acute and chronic toxicity were assessed. Detailed dosimetric data were collected. Results: Fifty-eight patients receiving 64 circumferential SBRT courses were identified (median age 61, KPS ≥70, 57% men). With a median follow-up of 15 months, the 12-month local control was 85% (eight events). Five and three recurrences were in the epidural space and bone, respectively. On multivariate analysis, increased PTV and uncontrolled systemic disease were significantly associated with an increased likelihood of LF; ≥95% PTV was covered by ≥95% prescription dose in 94% of the cases. The rate of new or progressive vertebral compression fracture was 8%. There were no myelitis events or any grade 3+ acute or late toxicities. Conclusions: For patients with circumferential disease, circumferential spine SBRT is feasible and may offer excellent LC without significant toxicity. A prospective evaluation of this approach is warranted.

16.
Radiother Oncol ; 157: 40-46, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33484751

RESUMEN

BACKGROUND AND PURPOSE: The goal of this prospective study is to validate the use of periodic imaging during treatment with a fiducial marker detection algorithm using radiofrequency transponders for prostate cancer patients undergoing treatment for radiation therapy. MATERIALS AND METHODS: Ten male patients were enrolled in this study and treated for prostate cancer with implanted electromagnetic monitoring beacons. We evaluated the accuracy and limitations of Intrafraction Motion Review (IMR) by comparing the known locations of the beacons using the electromagnetic monitoring system to the position data reported from IMR images. RESULTS: A total of 4054 images were taken during treatment. The difference in vector magnitude of the two methods is centered around zero (mean: 0.03 cm, SD: 0.16 cm) and Lin's Concordance Correlation Coefficient (CCC) is 0.99 (95% CI: 0.98, 1) overall. The Euclidean distance between the two methods was close to zero (median: 0.09 cm, IQR: 0.06, 0.14 cm). The difference in distance between any two markers was centered around zero (mean: 0.01 cm, SD: 0.12 cm) and Lin's CCC is 0.97 (95% CI: 0.96, 0.98) overall. CONCLUSION: The accuracy of the algorithm for detected markers within the 2D images is comparable to electromagnetic monitoring for fiducial identification when detected. IMR could provide an alternate solution for patients with contraindications of use of an electromagnetic monitoring system and a cost effective alternative to the acquisition of an additional system for patient monitoring, but does not provide data for pre-treatment set-up verification and real-time 3D positioning during treatment.


Asunto(s)
Neoplasias de la Próstata , Planificación de la Radioterapia Asistida por Computador , Marcadores Fiduciales , Humanos , Masculino , Movimiento (Física) , Movimiento , Estudios Prospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia
17.
Biomed Phys Eng Express ; 7(6)2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-34544065

RESUMEN

The purpose of this study was to develop and evaluate a framework to support automated standardized testing and analysis of Cone Beam Computed Tomography (CBCT) image quality QA across multiple institutions. A survey was conducted among the participating institutions to understand the variability of the CBCT QA practices. A commercial, automated software platform was validated by seven institutions participating in a consortium dedicated to automated quality assurance. The CBCT image analysis framework was used to compare periodic QA results among 23 linear accelerators (linacs) from seven institutions. The CBCT image quality metrics (geometric distortion, spatial resolution, contrast, HU constancy, uniformity and noise) data are plotted as a function of means with the upper and lower control limits compared to the linac acceptance criteria and AAPM recommendations. For example, mean geometric distortion and HU constancy metrics were found to be 0.13 mm (TG142 recommendation: ≤2 mm) and 13.4 respectively (manufacturer acceptance specification: ≤±50).Image upload and analysis process was fully automated using a MATLAB-based platform. This analysis enabled a quantitative, longitudinal assessment of the performance of quality metrics which were also compared across 23 linacs. For key CBCT parameters such as uniformity, contrast, and HU constancy, all seven institutions used stricter goals than what would be recommended based on the analysis of the upper and lower control limits. These institutional goals were also found to be stricter than that found in AAPM published guidance. This work provides a reference that could be used to machine-specific optimized tolerance of CBCT image maintenance via control charts to monitor performance we well as the sensitivity of different tests in support of a broader quality assurance program. To ensure the daily image quality needed for patient care, the optimized statistical QA metrics recommended to using along with risk-based QA.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Aceleradores de Partículas , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Programas Informáticos
18.
Radiother Oncol ; 155: 167-173, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33157173

RESUMEN

BACKGROUND/PURPOSE: Rates of acute esophagitis in breast cancer patients undergoing regional nodal irradiation (RNI) are under-reported. We set to identify esophageal dose-volume constraints associated with grade 2 esophagitis (G2E). We hypothesized that the G2E rate was higher with intensity modulated radiation therapy (IMRT) vs. 3D conformal radiation therapy (3DCRT). MATERIALS/METHODS: We identified patients that received RNI (50 Gy/25 fractions) from 1/2013 to 6/2019. We retrospectively contoured the esophagus in a consistent manner and recorded esophageal mean dose, max dose, and V10-V50. Our primary endpoint was the G2E rate. Receiver operating characteristics curves analysis (e.g., Youden's J statistic) were used to determine the cutpoints for the dosimetric parameters which were then tested in logistic regression models. RESULTS: We identified 531 patients (50% left-sided; 41% IMRT; 16.2% G2E). G2E was significantly higher in IMRT vs. 3DCRT patients (23.6% vs. 10.9%, p < 0.0001). All esophageal dosimetric parameters were significantly associated with G2E after adjusting for age and laterality. The cutpoints for esophageal mean dose, V10 and V20 were 11 Gy, 30%, and 15%, respectively. The associations between the dichotomized dose-volume parameters and G2E were OR = 3.82 (95% CI 2.28-6.40, p < 0.0001) for esophageal mean dose, OR = 5.37 (95% CI 3.01-9.58, p < 0.0001) for esophageal V10, and OR = 3.23 (95% CI 1.93-5.41, p < 0.0001) for esophageal V20. CONCLUSION: In patients receiving RNI with modern techniques, we found that G2E occurs in >15%, and more frequently with IMRT. These data strongly support the routine contouring of the esophagus in RNI planning, and our constraints should be incorporated in future prospective protocols of RNI.


Asunto(s)
Neoplasias de la Mama , Esofagitis , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Neoplasias de la Mama/radioterapia , Esofagitis/etiología , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Conformacional/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos , Estudios Retrospectivos
19.
Neurosurgery ; 88(5): 1021-1027, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33575784

RESUMEN

BACKGROUND: Spine surgery is indicated for select patients with mechanical instability, pain, and/or malignant epidural spinal cord compression, with or without neurological compromise. Stereotactic body radiotherapy (SBRT) is an option for durable local control (LC) for metastatic spine disease. OBJECTIVE: To determine factors associated with LC and progression-free survival (PFS) for patients receiving postoperative stereotactic spine radiosurgery. METHODS: We analyzed consecutive patients from 2013 to 2019 treated with surgical intervention followed by SBRT. Surgical interventions included laminectomy and vertebrectomy. SBRT included patients treated with 1 to 5 fractions of radiosurgery. We analyzed LC, PFS, overall survival (OS), and toxicity. Univariate and multivariate analyses were performed. RESULTS: A total of 63 patients were treated with a median follow-up of 12.5 mo. Approximately 75% of patients underwent vertebrectomy and 25% underwent laminectomy. One-year cumulative incidence of local failure was 19%. LC was significantly improved for patients receiving radiosurgery ≤40 d from surgery compared to that for patients receiving radiosurgery ≥40 d from surgery, 94% vs 75%, respectively, at 1 yr (P = .03). Patients who received preoperative embolization had improved LC with 1-yr LC of 88% vs 76% for those who did not receive preoperative embolization (P = .037). Significant predictors for LC on multivariate analysis were time from surgery to radiosurgery, higher radiotherapy dose, and preoperative embolization. The 1-yr PFS and OS was 56% and 60%, respectively. CONCLUSION: Postoperative radiosurgery has excellent and durable LC for spine metastasis. An important consideration when planning postoperative radiosurgery is minimizing delay from surgery to radiosurgery. Preoperative embolization and higher radiotherapy dose were associated with improved LC warranting further study.


Asunto(s)
Radiocirugia , Neoplasias de la Columna Vertebral , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Neoplasias de la Columna Vertebral/mortalidad , Neoplasias de la Columna Vertebral/secundario , Neoplasias de la Columna Vertebral/cirugía , Resultado del Tratamiento , Adulto Joven
20.
IEEE Trans Nucl Sci ; 57(1): 135-143, 2010 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-20352062

RESUMEN

A slit-slit collimator consists of two orthogonal slits and can be conceptualized as a generalized pinhole. Since the two slits are independent of each other, there can be independent axial and transaxial acceptance angles. A small axial acceptance angle may help mitigate axial blurring with circular orbits, allowing multiple copies axially. In addition, since the two slit planes can be placed at different distances with respect to the source, a better detector usage can be achieved, especially in the case of detectors and imaged objects with different aspect ratios. In this paper an analytical expression is derived for the sensitivity of slit-slit collimation including effective slit widths for photon penetration. An analytical expression for sensitivity is necessary in order to accurately model the system response. This expression could also be useful for comparing the slit-slit's sensitivity performance with others. When the effective slit width is used instead of the geometric slit width, the derived analytical expression accurately accounts for photon penetration of the aperture. The derived expression for the sensitivity was validated by Monte Carlo simulation for both geometric and penetrative cases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA