1.
AAPS PharmSciTech ; 19(1): 251-261, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28695328

RESUMEN

Onbrez Breezhaler® is a low-resistance capsule-based device that was developed to deliver indacaterol maleate. The study was designed to investigate the effects of both maximum flow rate (MIF) and inhalation volume (Vin) on the dose emission of indacaterol 150 and 300 µg dose strengths after one and two inhalations using dose unit sampling apparatus (DUSA) as well as to study the aerodynamic characteristics of indacaterol Breezhaler® using the Andersen cascade impactor (ACI) at a different set of MIF and Vin. Indacaterol 150 and 300 µg contain equal amounts of lactose per carrier. However, 150 µg has the smallest carrier size. The particle size distribution (PSD) of indacaterol DPI formulations 150 and 300 µg showed that the density of fine particles increased with the increase of the primary pressure. For both strengths (150 µg and 300 µg), ED1 increased and ED2 decreased when the inhalation flow rate and inhaled volume increased. The reduction in ED1 and subsequent increase in ED2 was such that when the Vin is greater than 1 L, then 60 L/min could be regarded as the minimum MIF. The Breezhaler was effective in producing respirable particles with an MMAD ≤5 µm irrespective of the inhalation flow rate, but the mass fraction of particles with an aerodynamic diameter <3 µm is more pronounced between 60 and 90 L/min. The dose emission of indacaterol was comparable for both dose strengths 150 and 300 µg. These in vitro results suggest that a minimum MIF of 60 L/min is required during routine use of Onbrez Breezhaler®, and confirm the good practice to make two separate inhalations from the same dose.


Asunto(s)
Indanos/administración & dosificación , Nebulizadores y Vaporizadores , Quinolonas/administración & dosificación , Administración por Inhalación , Indanos/química , Tamaño de la Partícula , Quinolonas/química
2.
Eur J Pharm Sci ; 139: 105059, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31472254

RESUMEN

Dry powder inhalers (DPIs) are passive devices used to administer inhaled medication for the management of asthma and chronic obstructive pulmonary disease (COPD). DPIs require patients to generate a sufficient internal turbulent airflow force during each inhalation to deaggregate the powdered drug formulation into an emitted dose containing particles with the greatest likelihood of lung deposition. This internal force is generated by the interaction between the user's inhalation flow and the resistance of the DPI. Traditional compendial in vitro methods of measuring dose emission use a vacuum pump to simulate inhalation. We have adapted this in vitro method by replacing the square wave inhalation profile generated by a vacuum pump with the inhalation profiles of patients using an empty DPI. This method enables accurate assessment of the actual dose they would have inhaled. In the present study, real-life inhalation profiles were selected from 15 patients with COPD who inhaled through an empty placebo Spiromax® DPI. Ex vivo dose emissions were measured for the medium (emitted dose of 160 µg/4.5 µg) and high-strength (320 µg/9 µg) budesonide/formoterol formulations from the Spiromax DPI. These profiles were used to investigate the effect of the primary inhalation parameter-peak inhalation flow (PIF). Some profiles were modified to isolate other inhalation parameters (namely, inhaled volume [Vin] and acceleration rate of the inhalation maneuver [ACIM]). Both the medium-strength and high-strength DuoResp Spiromax displayed flow-dependent dose emission. When the PIF of a patient's inhalation maneuver increased from 26.8 L/min to 69.7 L/min, there was a significant (p < 0.05) effect on the dose-emission characteristics of the medium-strength and high-strength DuoResp Spiromax. At each PIF, an increase in Vin from approximately 500 mL to 2000 mL had no effect on the dose-emission characteristics of either strength. However, at each Vin there was a significant (p < 0.05) effect on the dose-emission characteristics as PIF increased. The effect of ACIM on the dose-emission characteristics was small. The ex vivo methodology used in this study provides a practical approach to identify the actual dose a patient might inhale during routine real-life use of the DuoResp Spiromax.


Asunto(s)
Broncodilatadores/administración & dosificación , Combinación Budesonida y Fumarato de Formoterol/administración & dosificación , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Administración por Inhalación , Anciano , Inhaladores de Polvo Seco , Volumen Espiratorio Forzado , Humanos , Inhalación , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología
3.
Int J Pharm ; 522(1-2): 137-146, 2017 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-28254655

RESUMEN

The dose emitted from dry powder inhalers (DPI) is inhalation flow dependent and so varies with the peak inhalation flow (PIF) of a patient's inhalation maneuver (IM). Dose emission could also be affected by other IM parameters-the inhaled volume (Vin) and the initial acceleration rate of the IM (ACIM). We have adapted the compendial method for in-vitro DPI determinations so that inhalation profiles replace the inhalation square profile generated by a vacuum pump. These real-life patient inhalation profiles were measured when 18 COPD patients inhaled through an empty placebo Symbicort® Turbuhaler®. They have been used to identify the dose emission characteristics from a fixed dosed combination of 200µg budesonide plus 6µg formoterol Turbuhaler®. To isolate each inhalation parameter some profiles were modified to provide a further 9 profiles to study the influence of Vin and 27 to identify the effect of ACIM. The fine particle dose, total emitted dose and mass median aerodynamic diameter were significantly (p<0.05) influenced by PIF (p<0.05) whereas ACIM and Vin had only a small effect. The results show the value of this ex-vivo methodology to provide an insight into the dose that each patient would have inhaled during real-life use.


Asunto(s)
Administración por Inhalación , Aerosoles , Broncodilatadores/administración & dosificación , Broncodilatadores/uso terapéutico , Combinación Budesonida y Fumarato de Formoterol/administración & dosificación , Combinación Budesonida y Fumarato de Formoterol/uso terapéutico , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Anciano , Algoritmos , Combinación de Medicamentos , Inhaladores de Polvo Seco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de la Partícula
4.
Eur J Pharm Sci ; 104: 180-187, 2017 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-28351669

RESUMEN

Most patients using dry powder inhalers (DPIs) do not achieve the inhalation parameters recommended for pharmacopoeial in-vitro dose emission testing. The dose emission characteristics of formoterol from an Easyhaler® have been measured using the Andersen Cascade Impactor (ACI) with a maximum inhalation flow (MIF) of 28.3, 60 and 90L/min and inhaled volumes (Vin) of 240, 750, 1500 and 2000mL. The total emitted dose (TED) was significantly higher at 90L/min (p<0.05), but the difference in the TED between low (28.3L/min) and high (90L/min) flow rate was significantly reduced by increasing the Vin. The fine particle dose (FPD) was higher (p<0.05) at 90L/min for all Vin values compared to 28.3 and 60L/min. Similarly the mass median aerodynamic diameter (MMAD) was smaller at 90L/min across all Vin values. Dose emission characteristics were lower at 240mL for both MIFs. The results for 240mL could be due to an insufficient Vin pulled through the ACI or incomplete emptying of the dose metering cup. This study shows that the FPD, %FPF and MMAD were not significantly affected by the vin≥750mL and that an inhaled volume as low as 750mL could be used with the ACI.


Asunto(s)
Inhaladores de Polvo Seco/métodos , Fumarato de Formoterol/administración & dosificación , Administración por Inhalación , Humanos , Técnicas In Vitro , Tamaño de la Partícula