Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Clin Rheumatol ; 24(6): 295-301, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29424762

RESUMEN

BACKGROUND/OBJECTIVE: The objective of this study was to determine whether the extended or flexed knee positioning was superior for arthrocentesis and whether the flexed knee positioning could be improved by mechanical compression. METHODS: Fifty-five clinically effusive knees underwent arthrocentesis in a quality improvement intervention: 20 consecutive knees in the extended knee position using the superolateral approach, followed by 35 consecutive knees in the flexed knee position with and without an external compression brace placed on the suprapatellar bursa. Arthrocentesis success and fluid yield in milliliters were measured. RESULTS: Fluid yield for the extended knee was greater (191% greater) than the flexed knee (extended knee, 16.9 ± 15.7 mL; flexed knee, 5.8 ± 6.3 mL; P < 0.007). Successful diagnostic arthrocentesis (≥2 mL) was 95% (19/20) in the extended knee and 77% (27/35) in the flexed knee (P = 0.08). After mechanical compression was applied to the suprapatellar bursa and patellofemoral joint of the flexed knee, fluid yields were essentially identical (extended knee, 16.9 ± 15.7 mL; flexed knee, 16.7 ± 11.3 mL; P = 0.73), as were successful diagnostic arthrocentesis (≥2 mL) (extended knee 95% vs. flexed knee 100%, P = 0.12). CONCLUSIONS: The extended knee superolateral approach is superior to the flexed knee for conventional arthrocentesis; however, the extended knee positioning and flexed knee positioning have identical arthrocentesis success when mechanical compression is applied to the superior knee. This new flexed knee technique for arthrocentesis is a useful alternative for patients who are in wheelchairs, have flexion contractures, cannot be supine, or cannot otherwise extend their knee.


Asunto(s)
Artrocentesis , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla , Dolor Asociado a Procedimientos Médicos , Posicionamiento del Paciente/métodos , Anciano , Artrocentesis/efectos adversos , Artrocentesis/métodos , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Evaluación de Resultado en la Atención de Salud , Dolor Asociado a Procedimientos Médicos/diagnóstico , Dolor Asociado a Procedimientos Médicos/prevención & control , Mejoramiento de la Calidad
2.
Clin Orthop Relat Res ; 473(12): 3894-902, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26443774

RESUMEN

BACKGROUND: Greater levels of self-reported pain, pain catastrophizing, and depression have been shown to be associated with persistent pain and functional limitation after surgeries such as TKA. It would be useful for clinicians to be able to measure these factors efficiently. QUESTIONS/PURPOSES: We asked: (1) What is the association of whole-body pain with osteoarthritis (OA)-related knee pain, function, pain catastrophizing, and mental health? (2) What is the sensitivity and specificity for different cutoffs for body pain diagram region categories in relation to pain catastrophizing? METHODS: Patients (n = 267) with knee OA undergoing elective TKA at one academic center and two community orthopaedic centers were enrolled before surgery in a prospective cohort study. Questionnaires included the WOMAC Pain and Function Scales, Pain Catastrophizing Scale (PCS), Mental Health Inventory-5 (MHI-5), and a pain body diagram. The diagram documents pain in 19 anatomic areas. Based on the distribution of the anatomic areas, we established six different body regions. Our analyses excluded the index (surgically treated) knee. Linear regression was used to evaluate the association between the total number of nonindex painful sites on the whole-body pain diagram and measures of OA-related pain and function, mental health, and pain catastrophizing. Generalized linear regression was used to evaluate the association between the number of painful nonindex body regions (categorized as 0; 1-2; or 3-6) with our measures of interest. All models were adjusted for age, sex, and number of comorbid conditions. The cohort included 63% females and the mean age was 66 years (SD, 9 years). With removal of the index knee, the median pain diagram score was 2 (25(th), 75(th) percentiles, 1, 4) with a range of 0 to 15. The median number of painful body regions was 2 (25(th), 75(th) percentiles, 1, 3). RESULTS: After adjusting for age, sex, and number of comorbid conditions, we found modest associations between painful body region categories and mean scores for WOMAC physical function (r = 0.22, p < 0.001), WOMAC pain (r = 0.20, p = 0.001), MHI-5 (r = -0.31, p < 0.001), and PCS (r = 0.27, p < 0.001). A nonindex body pain region score greater than 0 had 100% (95% CI, 75%-100%) sensitivity for a pain catastrophizing score greater than 30 but a specificity of just 23% (95% CI, 18%-29%) . A score of 3 or greater had greater specificity (73%; 95% CI, 66%-79%) but lower sensitivity (53%; 95% CI, 27%-78%). CONCLUSIONS: We found modest associations between the number of painful sites on a whole-body pain diagram and the number of painful body regions and measures of OA-related pain, function, pain catastrophizing, and mental health. Patients with higher self-reported body pain region scores might benefit from further evaluation for depression and pain catastrophizing. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artralgia/psicología , Catastrofización/psicología , Salud Mental , Osteoartritis de la Rodilla/psicología , Centros Médicos Académicos , Anciano , Artralgia/diagnóstico , Artralgia/etiología , Artroplastia de Reemplazo de Rodilla , Catastrofización/diagnóstico , Catastrofización/etiología , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/cirugía , Dimensión del Dolor , Estudios Prospectivos , Factores de Riesgo , Encuestas y Cuestionarios , Estados Unidos
3.
J Am Acad Orthop Surg ; 21(6): 364-71, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23728961

RESUMEN

Researchers and clinicians operate in an increasingly complex clinical and regulatory environment in which understanding the principles governing human research is essential. However, most orthopaedic surgeons have not received in-depth training in regulatory requirements and scientific research methods. Ensuring that research is conducted in accordance with state and federal laws and ethical principles is essential to guard compromising patient information and avoid severe penalties for noncompliance. The researcher must understand the regulations for compliance and proper data management, including the requirements of the Health Insurance Portability and Accountability Act, proper application of informed consent, use of the Institutional Review Board, and data protection guidelines. Tools such as a regulatory binder can assist investigators in complying with requirements, maintaining regulatory standards, and ensuring a robust study design and conduct.


Asunto(s)
Experimentación Humana/ética , Experimentación Humana/legislación & jurisprudencia , Ortopedia/ética , Ortopedia/legislación & jurisprudencia , Confidencialidad , Conflicto de Intereses , Comités de Ética en Investigación , Humanos , Consentimiento Informado , Mala Conducta Científica , Estados Unidos
4.
Rheumatol Int ; 32(2): 513-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21253739

RESUMEN

Although intraarticular injections are important to the management of rheumatoid arthritis, there are few studies regarding the cost-effectiveness of alternative injection techniques. This randomized controlled study addressed the cost-effectiveness of two different low-cost, anatomic landmark palpation-directed intraarticular injection techniques. Ninety-six symptomatic rheumatoid knees were randomized to two different low-cost, palpation-guided intraarticular injection techniques utilizing (1) a conventional syringe or (2) a mechanical syringe, the RPD (the reciprocating procedure device). Three milliliters of 1% lidocaine were used to anesthetize the synovial membrane, followed by arthrocentesis and hydrodissection, and injection of 80 mg of triamcinolone acetonide utilizing the one-needle two-syringe technique. Baseline pain, procedural pain, aspirated fluid volume, pain at outcome (2 weeks and 6 months), responders, reinjection rates, cost/patient/year, and cost/responder/year were determined. Pain was measured with the 10 cm Visual Analogue Pain Scale (VAS). Both techniques significantly reduced pain scores at outcome from baseline (P < 0.001). The mechanical syringe technique resulted in a greater volume of aspirated fluid (P < 0.01), a 38% reduction in procedural pain (P < 0.001), a 24% reduction in pain scores at outcome (P < 0.03), an increase in the responder rate (P < 0.025), 33% increase in the time to next injection (P < 0.001), 23% ($35 US) reduction in cost/patient/year for a patient treated in a physician office (P < 0.001), 24% reduction ($26 US) in cost/patient/year for a hospital outpatient (P < 0.001), and 51% ($151 US) reduction in cost/responder/year (P < 0.001). The outcomes and cost-effectiveness of intraarticular injection of the rheumatoid knee can be improved significantly with low-cost alternations in technique.


Asunto(s)
Artralgia/tratamiento farmacológico , Artritis Reumatoide/tratamiento farmacológico , Adulto , Anciano , Antiinflamatorios/administración & dosificación , Antiinflamatorios/economía , Artralgia/economía , Artralgia/etiología , Artritis Reumatoide/complicaciones , Artritis Reumatoide/economía , Análisis Costo-Beneficio/economía , Análisis Costo-Beneficio/tendencias , Femenino , Humanos , Inyecciones Intraarticulares/economía , Inyecciones Intraarticulares/métodos , Inyecciones Intraarticulares/tendencias , Masculino , Persona de Mediana Edad , Triamcinolona/administración & dosificación , Triamcinolona/economía
5.
Int J Rheum Dis ; 25(3): 303-310, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34984834

RESUMEN

AIM: Complete arthrocentesis of the effusive knee ameliorates patient pain, reduces intra-articular and intraosseous pressure, removes inflammatory cytokines, and has been shown to substantially improve the therapeutic outcomes of intra-articular injections. However, conventional arthrocentesis incompletely decompresses the knee, leaving considerable residual synovial fluid in the intra-articular space. The present study determined whether external pneumatic circumferential compression of the effusive knee permitted more successful arthrocentesis and complete joint decompression. METHODS: Using a paired sample design, 50 consecutive effusive knees underwent conventional arthrocentesis and then arthrocentesis with pneumatic compression. Pneumatic compression was applied to the superior knee using a conventional thigh blood pressure cuff inflated to 100 mm Hg which compressed the suprapatellar bursa and patellofemoral joint, forcing fluid from the superior knee to the anterolateral portal where the fluid could be accessed. Arthrocentesis success and fluid yield in mL before and after pneumatic compression were determined. RESULTS: Successful diagnostic arthrocentesis (≥3 mL) of the effusive knee was 82% (41/50) with conventional arthrocentesis and increased to 100% (50/50) with pneumatic compression (P = .001). Synovial fluid yields increased by 144% (19.8 ± 17.1 mL) with pneumatic compression (conventional arthrocentesis; 13.7 ± 16.4 mL, pneumatic compression: 33.4 ± 26.5 mL; 95% CI: 10.9 < 19.7 < 28.9 mL, P < .0001). CONCLUSIONS: Conventional arthrocentesis routinely does not fully decompress the effusive knee. External circumferential pneumatic compression markedly improves arthrocentesis success and fluid yield, and permits complete decompression of the effusive knee. Pneumatic compression of the effusive knee with a thigh blood pressure cuff is an inexpensive and widely available technique to improve arthrocentesis outcomes.


Asunto(s)
Artralgia/cirugía , Artrocentesis/métodos , Osteoartritis de la Rodilla/cirugía , Anciano , Artralgia/diagnóstico , Artralgia/etiología , Femenino , Humanos , Inyecciones Intraarticulares , Articulación de la Rodilla , Masculino , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico , Resultado del Tratamiento , Ultrasonografía
6.
Biochem Biophys Res Commun ; 405(4): 673-7, 2011 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-21284937

RESUMEN

Non-toxic derivatives of botulinum neurotoxin A (BoNT/A) have potential use as neuron-targeting delivery vehicles, and as reagents to study intracellular trafficking. We have designed and expressed an atoxic derivative of BoNT/A (BoNT/A ad) as a full-length 150 kDa molecule consisting of a 50 kDa light chain (LC) and a 100 kDa heavy chain (HC) joined by a disulfide bond and rendered atoxic through the introduction of metalloprotease-inactivating point mutations in the light chain. Studies in neuronal cultures demonstrated that BoNT/A ad cannot cleave synaptosomal-associated protein 25 (SNAP25), the substrate of wt BoNT/A, and that it effectively competes with wt BoNT/A for binding to endogenous neuronal receptors. In vitro and in vivo studies indicate accumulation of BoNT/A ad at the neuromuscular junction of the mouse diaphragm. Immunoprecipitation studies indicate that the LC of BoNT/A ad forms a complex with SNAP25 present in the neuronal cytosolic fraction, demonstrating that the atoxic LC retains the SNAP25 binding capability of the wt toxin. Toxicity of BoNT/A ad was found to be reduced approximately 100,000-fold relative to wt BoNT/A.


Asunto(s)
Toxinas Botulínicas Tipo A/metabolismo , Neuronas/metabolismo , Proteínas Recombinantes/metabolismo , Animales , Bioensayo , Toxinas Botulínicas Tipo A/genética , Toxinas Botulínicas Tipo A/toxicidad , Citosol/metabolismo , Femenino , Ratones , Ratones Endogámicos ICR , Unión Neuromuscular/metabolismo , Neuronas/efectos de los fármacos , Ratas , Ratas Sprague-Dawley , Proteínas Recombinantes/genética , Proteínas Recombinantes/toxicidad , Proteína 25 Asociada a Sinaptosomas/metabolismo
7.
J Clin Rheumatol ; 17(8): 409-15, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22089991

RESUMEN

OBJECTIVE: The present randomized controlled study investigated whether sonographic needle guidance affected the outcomes of intra-articular injection for osteoarthritis of the knee. METHODS: Ninety-four noneffusive knees with osteoarthritis were randomized to injection by conventional palpation-guided anatomic landmark injection or sonographic image-guided injection enhanced with a 1-handed mechanical (the reciprocating procedure device) syringe. After intra-articular placement and synovial space dilation were confirmed by sonography, a syringe exchange was performed, and 80 mg of triamcinolone acetonide was injected with the second syringe through the indwelling intra-articular needle. Baseline pain, procedural pain, pain at outcome (2 weeks and 6 months), responders, therapeutic duration, reinjection rates, total cost, and cost per responder were determined. RESULTS: Relative to conventional palpation-guided anatomic landmark methods, sonographic guidance for injection of the knee resulted in 48% reduction in procedural pain (P < 0.001), a 42% reduction in pain scores at outcome (P < 0.03), 107% increase in the responder rate (P < 0.001), 52% reduction in the nonresponder rate (P < 0.001), a 36% increase in therapeutic duration (P = 0.01), a 13% reduction ($17) in cost per patient per year, and a 58% ($224) reduction in cost per responder per year for a hospital outpatient (P < 0.001). CONCLUSIONS: Sonographic needle guidance reduced procedural pain and improved the clinical outcomes and cost-effectiveness of intra-articular injections of the osteoarthritic knee.


Asunto(s)
Inyecciones Intraarticulares/economía , Osteoartritis de la Rodilla/tratamiento farmacológico , Triamcinolona Acetonida/administración & dosificación , Ultrasonografía Intervencional/economía , Anciano , Análisis Costo-Beneficio , Femenino , Humanos , Inyecciones Intraarticulares/efectos adversos , Masculino , Persona de Mediana Edad , Dolor/prevención & control , Dimensión del Dolor , Resultado del Tratamiento
8.
Sci Transl Med ; 13(575)2021 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-33408188

RESUMEN

Botulism is caused by a potent neurotoxin that blocks neuromuscular transmission, resulting in death by asphyxiation. Currently, the therapeutic options are limited and there is no antidote. Here, we harness the structural and trafficking properties of an atoxic derivative of botulinum neurotoxin (BoNT) to transport a function-blocking single-domain antibody into the neuronal cytosol where it can inhibit BoNT serotype A (BoNT/A1) molecular toxicity. Post-symptomatic treatment relieved toxic signs of botulism and rescued mice, guinea pigs, and nonhuman primates after lethal BoNT/A1 challenge. These data demonstrate that atoxic BoNT derivatives can be harnessed to deliver therapeutic protein moieties to the neuronal cytoplasm where they bind and neutralize intracellular targets in experimental models. The generalizability of this platform might enable delivery of antibodies and other protein-based therapeutics to previously inaccessible intraneuronal targets.


Asunto(s)
Toxinas Botulínicas Tipo A , Botulismo , Anticuerpos de Dominio Único , Animales , Botulismo/tratamiento farmacológico , Cobayas , Ratones , Modelos Animales , Neurotoxinas
9.
Protein Expr Purif ; 71(1): 62-73, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20045734

RESUMEN

Work from multiple laboratories has clarified how the structural domains of botulinum neurotoxin A (BoNT/A) disable neuronal exocytosis, but important questions remain unanswered. Because BoNT/A intoxication disables its own uptake, light chain (LC) does not accumulate in neurons at detectable levels. We have therefore designed, expressed and purified a series of BoNT/A atoxic derivatives (ad) that retain the wild type features required for native trafficking. BoNT/A1ad(ek) and BoNT/A1ad(tev) are full length derivatives rendered atoxic through double point mutations in the LC protease (E(224)>A; Y(366)>A). DeltaLC-peptide-BoNT/A(tev) and DeltaLC-GFP-BoNT/A(tev) are derivatives wherein the catalytic portion of the LC is replaced with a short peptide or with GFP plus the peptide. In all four derivatives, we have fused the S6 peptide sequence GDSLSWLLRLLN to the N-terminus of the proteins to enable site-specific attachment of cargo using Sfp phosphopantetheinyl transferase. Cargo can be attached in a manner that provides a homogeneous derivative population rather than a polydisperse mixture of singly and multiply-labeled molecular species. All four derivatives contain an introduced cleavage site for conversion into disulfide-bonded heterodimers. These constructs were expressed in a baculovirus system and the proteins were secreted into culture medium and purified to homogeneity in yields ranging from 1 to 30 mg per liter. These derivatives provide unique tools to study toxin trafficking in vivo, and to assess how the structure of cargo linked to the heavy chain (HC) influences delivery to the neuronal cytosol. Moreover, they create the potential to engineer BoNT-based molecular vehicles that can target therapeutic agents to the neuronal cytoplasm.


Asunto(s)
Toxinas Botulínicas Tipo A/metabolismo , Neuronas/metabolismo , Ingeniería de Proteínas/métodos , Secuencia de Aminoácidos , Toxinas Botulínicas Tipo A/química , Toxinas Botulínicas Tipo A/aislamiento & purificación , Colorantes Fluorescentes/metabolismo , Proteínas Fluorescentes Verdes/metabolismo , Datos de Secuencia Molecular , Proteínas Mutantes/química , Proteínas Mutantes/metabolismo , Péptidos/química , Péptidos/aislamiento & purificación , Procesamiento Proteico-Postraduccional , Transporte de Proteínas , Proteínas Recombinantes de Fusión/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray
10.
Clin Rheumatol ; 38(8): 2255-2263, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30953230

RESUMEN

INTRODUCTION/OBJECTIVES: We hypothesized that mechanical compression of the knee in rheumatoid arthritis (RA) would mobilize occult extractable fluid and improve arthrocentesis success. METHODS: Sixty-seven consecutive knees with RA and 186 knees with OA and were included. Conventional arthrocentesis was performed and success and volume (milliliters) determined; the needle was left intraarticularly, and mechanical compression was applied with an elastomeric knee brace. Arthrocentesis was then resumed until fluid return ceased. Fluid was characterized as to volume and cell counts. RESULTS: In the RA, knee mechanical compression decreased failed diagnostic arthrocentesis from 56.7% (38/67) to 26.9% (18/67) (- 47.4%, p = 0.003) and increased absolute arthrocentesis yield from 4.7 ± 10.3 ml to 9.8 ± 9.8 ml (108% increase, 95% CI - 8.5 < - 5.1 < - 1.7 p = 0.0038). Total extractable fluid yield was 96% greater in RA (9.8 ± 9.8 ml) than OA (5.0 ± 9.4 ml, p = 0.0008), and occult extractable fluid was 77% greater in RA than OA (RA 5.3 ± 8.7 ml, OA 3.0 ± 5.5 ml, p = 0.046). Large effusions versus small effusions in RA demonstrated increased neutrophils in synovial fluid (p = 0.04) but no difference in radiologic arthritis grade (p = 0.87). In contrast, large effusions versus small effusions in OA demonstrated no difference in neutrophils in synovial fluid (p = 0.87) but significant different radiologic arthritis grade (p = 0.04). CONCLUSION: Mechanical compression improves the success of diagnostic and therapeutic knee arthrocentesis in both RA and OA. Large effusions in RA are associated with increased neutrophil counts but not arthritis grade; in contrast, large effusions in OA are associated with more severe arthritis grades but not increased neutrophil counts. Key points• Mechanical compression of the painful knee improves arthrocentesis success and fluid yield in both rheumatoid arthritis and osteoarthritis.• The painful rheumatoid knee contains approximately 100% more fluid than the osteoarthritic knee.• Large effusions in the osteoarthritic knee are characterized by higher grades of mechanical destruction but not increased neutrophil counts.• In contrast, large effusions in the rheumatoid knee are characterized by higher synovial fluid neutrophil counts but not the grade of mechanical destruction, indicating different mechanisms of effusion formation in rheumatoid arthritis versus osteoarthritis.


Asunto(s)
Artritis Reumatoide/terapia , Tirantes , Inflamación/terapia , Osteoartritis de la Rodilla/terapia , Líquido Sinovial , Anciano , Artrocentesis , Femenino , Humanos , Rodilla , Masculino , Persona de Mediana Edad , Estrés Mecánico
11.
Orthop Clin North Am ; 49(4): 389-396, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30224000

RESUMEN

Technologies continue to shape the path of medical treatment. Orthopedic surgeons benefit from becoming more aware of how twenty-first century information technology (IT) can benefit patients. The percentage of orthopedic patients utilizing IT resources is increasing, and new IT tools are becoming utilized. These include disease-specific applications. This article highlights the opportunity for developing IT tools applicable to the growing population of patients with osteoarthritis (OA), and presents a potential solution that can facilitate the way OA education and treatment are delivered, and thereby maximize efficiency for the health care system, the physician, and the patient.


Asunto(s)
Artritis/cirugía , Artroplastia de Reemplazo , Manejo de la Enfermedad , Educación del Paciente como Asunto/métodos , Telemedicina/métodos , Humanos
12.
Clin Rheumatol ; 37(8): 2251-2259, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28913649

RESUMEN

We hypothesized that constant compression of the knee would mobilize residual synovial fluid and promote successful arthrocentesis. Two hundred and ten knees with grade II-III osteoarthritis were included in this paired design study: (1) conventional arthrocentesis was performed with manual compression and success and volume (milliliters) determined; and (2) the intra-articular needle was left in place, and a circumferential elastomeric brace was tightened on the knee to provide constant compression. Arthrocentesis was attempted again and additional fluid volume was determined. Diagnostic procedural cost-effectiveness was determined using 2017 US Medicare costs. No serious adverse events were noted in 210 subjects. In the 158 noneffusive (dry) knees, sufficient synovial fluid for diagnostic purposes (≥ 2 ml) was obtained in 5.0% (8/158) without compression and 22.8% (36/158) with compression (p = 0.0001, z for 95% CI = 1.96), and the absolute volume of arthrocentesis fluid obtained without compression was 0.28 ± 0.79 versus 1.10 ± 1.81 ml with compression (293% increase, p = 0.0001). In the 52 effusive knees, diagnostic synovial fluid (≥ 2 ml) was obtained in 75% (39/52) without compression and 100% (52/52) with compression (p = 0.0001, z for 95% CI = 1.96), and the absolute volume of arthrocentesis without compression was 14.7 ± 13.8 versus 25.3 ± 15.5 ml with compression (72.1% increase, p = 0.0002). Diagnostic procedural cost-effectiveness was $655/sample without compression and $387/sample with compression. The new technique of constant compression via circumferential mechanical compression mobilizes residual synovial fluid beyond manual compression improving the success, cost-effectiveness, and yield of diagnostic and therapeutic arthrocentesis in both the effusive and noneffusive knee.


Asunto(s)
Artrocentesis/métodos , Tirantes , Vendajes de Compresión , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/terapia , Líquido Sinovial , Artrocentesis/economía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor Asociado a Procedimientos Médicos/diagnóstico
13.
Sci Rep ; 7: 42923, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28220863

RESUMEN

Botulinum neurotoxin (BoNT) binds to and internalizes its light chain into presynaptic compartments with exquisite specificity. While the native toxin is extremely lethal, bioengineering of BoNT has the potential to eliminate toxicity without disrupting neuron-specific targeting, thereby creating a molecular vehicle capable of delivering therapeutic cargo into the neuronal cytosol. Building upon previous work, we have developed an atoxic derivative (ad) of BoNT/C1 through rationally designed amino acid substitutions in the metalloprotease domain of wild type (wt) BoNT/C1. To test if BoNT/C1 ad retains neuron-specific targeting without concomitant toxic host responses, we evaluated the localization, activity, and toxicity of BoNT/C1 ad in vitro and in vivo. In neuronal cultures, BoNT/C1 ad light chain is rapidly internalized into presynaptic compartments, but does not cleave SNARE proteins nor impair spontaneous neurotransmitter release. In mice, systemic administration resulted in the specific co-localization of BoNT/C1 ad with diaphragmatic motor nerve terminals. The mouse LD50 of BoNT/C1 ad is 5 mg/kg, with transient neurological symptoms emerging at sub-lethal doses. Given the low toxicity and highly specific neuron-targeting properties of BoNT/C1 ad, these data suggest that BoNT/C1 ad can be useful as a molecular vehicle for drug delivery to the neuronal cytoplasm.


Asunto(s)
Toxinas Botulínicas/metabolismo , Portadores de Fármacos/química , Secuencia de Aminoácidos , Animales , Toxinas Botulínicas/genética , Toxinas Botulínicas/toxicidad , Células Cultivadas , Dimerización , Femenino , Dosificación Letal Mediana , Ratones , Microscopía Confocal , Células Madre Embrionarias de Ratones/citología , Neuronas/citología , Neuronas/metabolismo , Transmisión Sináptica/efectos de los fármacos , Proteína 25 Asociada a Sinaptosomas/metabolismo , Sintaxina 1/metabolismo
14.
Sci Rep ; 6: 30429, 2016 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-27484492

RESUMEN

Cyto-012 is a recombinant derivative of Botulinum neurotoxin Type A (BoNT/A). It primarily differs from wild type (wt) BoNT/A1 in that it incorporates two amino acid substitutions in the catalytic domain of the light chain (LC) metalloprotease (E224 > A and Y366 > A), designed to provide a safer clinical profile. Cyto-012 is specifically internalized into rat cortical and hippocampal neurons, and cleaves Synaptosomal-Associated Protein 25 (SNAP-25), the substrate of wt BoNT/A, but exhibits slower cleavage kinetics and therefore requires a higher absolute dose to exhibit pharmacologic activity. The pharmacodynamics of Cyto-012 and wt BoNT/A have similar onset and duration of action using the Digital Abduction Assay (DAS). Intramuscular LD50 values for Cyto-012 and wt BoNT/A respectively, were 0.63 ug (95% CI = 0.61, 0.66) and 6.22 pg (95% CI = 5.42, 7.02). ED50 values for Cyto-012 and wt BoNT/A were respectively, 0.030 ug (95% CI = 0.026, 0.034) and 0.592 pg (95% CI = 0.488, 0.696). The safety margin (intramuscular LD50/ED50 ratio) for Cyto-012 was found to be improved 2-fold relative to wt BoNT/A (p < 0.001). The DAS response to Cyto-012 was diminished when a second injection was administered 32 days after the first. These data suggest that the safety margin of BoNT/A can be improved by modulating their activity towards SNAP-25.


Asunto(s)
Toxinas Botulínicas Tipo A/toxicidad , Fármacos Neuromusculares/toxicidad , Animales , Toxinas Botulínicas Tipo A/farmacocinética , Células Cultivadas , Femenino , Dosificación Letal Mediana , Ratones , Músculo Esquelético/metabolismo , Fármacos Neuromusculares/farmacocinética , Neuronas/efectos de los fármacos , Neuronas/metabolismo , Ratas , Ratas Sprague-Dawley , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/toxicidad
15.
Am J Manag Care ; 21(8): e494-500, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26625504

RESUMEN

OBJECTIVES: Osteoarthritis of the knee is a chronic disease associated with pain and reduced quality of life. The ability to reliably measure patient-reported symptoms is important for clinical decision making and evaluation of outcomes. Electronic and web-based tools can eliminate much of the labor-intensive aspects of questionnaire administration and enables both real-time evaluation of responses by physicians and integration of data from multiple sites. This article describes the results of implementing a single integrated electronic questionnaire system into routine orthopedic practice at 2 diverse institutions. STUDY DESIGN: Case study. METHODS: A web-based version of a general quality-of-life questionnaire (EuroQol 5-dimension [EQ-5D]) and the pain domain of a disease-specific questionnaire (Knee Osteoarthritis Outcome Score [KOOS]) were administered in the office waiting room to (n = 666) patients at 2 centers over a 9-month period using touchscreen devices. Data were analyzed and descriptive statistics were calculated to assess feasibility of integration into the distinct work flows and to assess the agreement of the results. RESULTS: The electronic questionnaire had a completion rate of 93% to 95%. Average questionnaire completion times were 3 to 5 minutes at each institution. Mean EQ-5D and KOOS scores for patients pre- and postsurgery were also consistent with prior literature studies. CONCLUSIONS: Lessons learned for future adoption of questionnaire systems elsewhere include the need for baseline assessment of clinic work flows to identify the optimal point of administration and the need for IT support. This study demonstrates the feasibility of routinely collecting patient-reported data as part of standard care, which will become increasingly important as the nationwide emphasis on tracking quality and cost-effectiveness of treatments in orthopedics grows.


Asunto(s)
Osteoartritis de la Rodilla/complicaciones , Dimensión del Dolor , Medición de Resultados Informados por el Paciente , Calidad de Vida , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ortopedia , Administración de la Práctica Médica , Interfaz Usuario-Computador , Adulto Joven
16.
Am J Med Qual ; 30(5): 484-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-24852172

RESUMEN

The Centers for Medicare & Medicaid Services considers readmissions within 30 days of discharge to be a quality indicator. Hospitals' and eventually physicians' readmission rates will be used to determine payment for services. It is imperative that health care providers understand which patients are at risk for readmission so that they can apply the appropriate preventive interventions. The research team analyzed all orthopedic admissions and readmissions at their institution from September 2008 to April 2011 in this study. Preparing for the next stage in health care reform, identifying any preoperative factors that may place certain patients into a "high-risk" category for readmission following an orthopedic procedure is of paramount importance. This data analysis of more than 13 000 patients noted that race-based and income-based risk factors did not translate into significant risk factors or predictors of 30-day readmission following orthopedic admission.


Asunto(s)
Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/estadística & datos numéricos , Readmisión del Paciente/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Clase Social , Estudios de Cohortes , Femenino , Disparidades en Atención de Salud , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Pronóstico , Grupos Raciales , Factores de Riesgo , Compra Basada en Calidad
17.
J Bone Joint Surg Am ; 97(23): 1921-8, 2015 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-26631992

RESUMEN

BACKGROUND: Preoperative risk stratification and optimization of preoperative care may be helpful in reducing readmission rates after primary total joint arthroplasty. Assessment of the predictive value of individual modifiable risk factors without a tool to assess cumulative risk may not provide proper risk stratification of patients with regard to potential readmissions. As part of a Perioperative Orthopaedic Surgical Home model, we developed a scoring system, the Readmission Risk Assessment Tool (RRAT), which allows for risk stratification in patients undergoing elective primary total joint arthroplasty at our institution. The purpose of this study was to analyze the relationship between the RRAT score and readmission after primary hip or knee arthroplasty. METHODS: The RRAT, which is scored incrementally on the basis of the number and severity of modifiable comorbidities, was used to generate readmission scores for a cohort of 207 readmitted patients and two cohorts (one random and one age-matched) of 234 non-readmitted patients each. Regression analysis was performed to assess the strength of association of individual risk factors and the RRAT score with readmissions. We also calculated the odds and odds ratio (OR) at each RRAT score level to identify patients with relatively higher risk of readmission. RESULTS: There were 207 (2.08%) readmissions among 9930 patients over a six-year period (2008 through 2013). Surgical site infection was the most common cause of readmission (ninety-three cases, 45%). The median RRAT scores were 3 (IQR [interquartile range], 1 to 4) and 1 (IQR, 0 to 2) for readmitted and non-readmitted groups, respectively. An RRAT score of ≥3 was significantly associated with higher odds of readmission. CONCLUSIONS: Population health management, cost-effective care, and optimization of outcomes to maximize value are the new maxims for health-care delivery in the United States. We found that the RRAT score had a significant association with readmission after joint arthroplasty and could potentially be a clinically useful tool for risk mitigation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Toma de Decisiones Clínicas/métodos , Técnicas de Apoyo para la Decisión , Readmisión del Paciente , Complicaciones Posoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
18.
PLoS One ; 9(1): e85517, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24465585

RESUMEN

We have previously described genetic constructs and expression systems that enable facile production of recombinant derivatives of botulinum neurotoxins (BoNTs) that retain the structural and trafficking properties of wt BoNTs. In this report we describe the properties of one such derivative, BoNT/A ad, which was rendered atoxic by introducing two amino acid mutations to the light chain (LC) of wt BoNT/A, and which is being developed as a molecular vehicle for delivering drugs to the neuronal cytoplasm. The neuronal binding, internalization, and intracellular trafficking of BoNT/A ad in primary hippocampal cultures was evaluated using three complimentary techniques: flow cytometry, immunohistochemistry, and Western blotting. Neuronal binding of BoNT ad was significantly increased when neurons were incubated in depolarizing medium. Flow cytometry demonstrated that BoNT/A ad internalized into neurons but not glia. After 24 hours, the majority of the neuron-bound BoNT/A ad became internalized, as determined by its resistance to pronase E-induced proteolytic degradation of proteins associated with the plasma membrane of intact cells. Significant amounts of the atoxic LC accumulated in a Triton X-100-extractable fraction of the neurons, and persisted as such for at least 11 days with no evidence of degradation. Immunocytochemical analysis demonstrated that the LC of BoNT/A ad was translocated to the neuronal cytoplasm after uptake and was specifically targeted to SNARE proteins. The atoxic LC consistently co-localized with synaptic markers SNAP-25 and VAMP-2, but was rarely co-localized with markers for early or late endosomes. These data demonstrate that BoNT/A ad mimics the trafficking properties of wt BoNT/A, confirming that our platform for designing and expressing BoNT derivatives provides an accessible system for elucidating the molecular details of BoNT trafficking, and can potentially be used to address multiple medical and biodefense needs.


Asunto(s)
Toxinas Botulínicas Tipo A/administración & dosificación , Toxinas Botulínicas Tipo A/farmacocinética , Endocitosis , Neuronas/metabolismo , Animales , Western Blotting , Toxinas Botulínicas Tipo A/genética , Células Cultivadas , Citoplasma/metabolismo , Femenino , Citometría de Flujo , Hipocampo/citología , Hipocampo/embriología , Hipocampo/metabolismo , Microscopía Confocal , Mutación , Neurotoxinas/administración & dosificación , Neurotoxinas/genética , Neurotoxinas/farmacocinética , Unión Proteica , Transporte de Proteínas , Ratas , Ratas Sprague-Dawley , Factores de Tiempo , Proteína 2 de Membrana Asociada a Vesículas/metabolismo
19.
J Rheumatol ; 38(2): 252-63, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21078710

RESUMEN

OBJECTIVE: We studied whether sonographic needle guidance affected the outcomes of intraarticular (IA) injection for inflammatory arthritis. METHODS: Joints with inflammatory arthritis (n = 244; 76% rheumatoid arthritis, 3% small joints, 51% intermediate, and 46% large) were randomized to injection by conventional palpation-guided anatomic injection (120 joints) or sonographic image-guided injection enhanced with a 1-handed reciprocating procedure device mechanical syringe (124 joints). A 1-needle, 2-syringe technique was used. After IA placement and synovial space dilation were confirmed by sonography, a syringe exchange was performed, and triamcinolone acetonide was injected with the second syringe through the indwelling IA needle. Baseline pain, procedural pain, pain at outcome (2 weeks and 6 months), responders, therapeutic duration, reinjection rates, total cost, and cost per responder were determined. RESULTS: Relative to conventional palpation-guided methods, sonographic guidance for injection of inflammatory arthritis resulted in an 81% reduction in injection pain (p < 0.001), 35% reduction in pain scores at outcome (p < 0.02), 38% increase in the responder rate (p < 0.003), 34% reduction in the non-responder rate (p < 0.003), 32% increase in therapeutic duration (p = 0.01), 8% reduction ($7) in cost/patient/year, and a 33% ($64) reduction in cost/responder/year for a hospital outpatient (p < 0.001). CONCLUSION: Sonographic needle guidance improves the performance, clinical outcomes, and cost-effectiveness of IA injections for inflammatory arthritis. (Clinical Trial Identifier NCT00651625).


Asunto(s)
Artritis/economía , Inflamación/economía , Articulaciones/diagnóstico por imagen , Corticoesteroides/uso terapéutico , Artritis/diagnóstico por imagen , Artritis/tratamiento farmacológico , Análisis Costo-Beneficio/economía , Femenino , Humanos , Inflamación/diagnóstico por imagen , Inflamación/tratamiento farmacológico , Inyecciones Intraarticulares/economía , Inyecciones Intraarticulares/métodos , Modelos Logísticos , Masculino , Dimensión del Dolor , Resultado del Tratamiento , Ultrasonografía
20.
Artículo en Inglés | MEDLINE | ID: mdl-21447197

RESUMEN

BACKGROUND: The extended knee lateral midpatellar portal for intraarticular injection of the knee is accurate but is not practical for all patients. We hypothesized that a modified anteriolateral portal where the synovial membrane of the medial femoral condyle is the target would be highly accurate and effective for intraarticular injection of the knee. METHODS: 83 subjects with non-effusive osteoarthritis of the knee were randomized to intraarticular injection using the modified anteriolateral bent knee versus the standard lateral midpatellar portal. After hydrodissection of the synovial membrane with lidocaine using a mechanical syringe (reciprocating procedure device), 80 mg of triamcinolone acetonide were injected into the knee with a 2.0-in (5.1-cm) 21-gauge needle. Baseline pain, procedural pain, and pain at outcome (2 weeks and 6 months) were determined with the 10 cm Visual Analogue Pain Score (VAS). The accuracy of needle placement was determined by sonographic imaging. RESULTS: The lateral midpatellar and anteriolateral portals resulted in equivalent clinical outcomes including procedural pain (VAS midpatellar: 4.6 ± 3.1 cm; anteriolateral: 4.8 ± 3.2 cm; p = 0.77), pain at outcome (VAS midpatellar: 2.6 ± 2.8 cm; anteriolateral: 1.7 ± 2.3 cm; p = 0.11), responders (midpatellar: 45%; anteriolateral: 56%; p = 0.33), duration of therapeutic effect (midpatellar: 3.9 ± 2.4 months; anteriolateral: 4.1 ± 2.2 months; p = 0.69), and time to next procedure (midpatellar: 7.3 ± 3.3 months; anteriolateral: 7.7 ± 3.7 months; p = 0.71). The anteriolateral portal was 97% accurate by real-time ultrasound imaging. CONCLUSION: The modified anteriolateral bent knee portal is an effective, accurate, and equivalent alternative to the standard lateral midpatellar portal for intraarticular injection of the knee. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00651625.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA