RESUMEN
BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.
Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiologíaRESUMEN
BACKGROUND: Although transcatheter aortic valve replacement (TAVR) therapy continues to grow, there have been concerns about the occurrence of hypoattenuating leaflet thickening (HALT), which may affect prosthesis function or durability. This study aimed to examine prosthesis frame factors and correlate their extent to the frequency of HALT and clinical outcomes. METHODS: We prospectively examined 565 patients with cardiac computed tomography screening for HALT at 30 days after balloon-expandable SAPIEN3 and self-expanding EVOLUT TAVR. Deformation of the TAVR prostheses, asymmetric prosthesis leaflet expansion, prosthesis sinus volumes, and commissural alignment were analyzed on the postprocedural computed tomography. For descriptive purposes, an index of prosthesis deformation was calculated, with values >1.00 representing relative midsegment underexpansion. A time-to-event model was performed to evaluate the association of HALT with the clinical outcome. RESULTS: Overall, HALT was present in 21% of SAPIEN3 patients and in 16% of EVOLUT patients at 30 days after TAVR. The occurrence of HALT was directly associated with greater prosthesis frame deformation (P<0.001), worse asymmetry of the leaflets (P<0.001), and smaller TAVR neosinus volumes (P<0.001). These relations were present in both prosthetic types and in all of their size ranges (all P<0.05). In multivariable analyses that include clinical variables previously associated with HALT (eg, anticoagulant therapy), variables of TAVR prosthesis deformation remained predictive of HALT. Although HALT was not associated with changes in prosthetic hemodynamics, its presence was associated with the risk of mortality at 1 year, with respect to greater incidences of all-cause mortality (hazard ratio, 2.98 [95% CI, 1.57-5.63]; P=0.001), cardiac death (hazard ratio, 4.58 [95% CI, 1.81-11.6]; P=0.001), and a composite outcome of all-cause mortality and heart failure hospitalization (hazard ratio, 1.94 [95% CI, 1.14-3.30]; P=0.02) with adjustment for age, sex, and comorbidities. CONCLUSIONS: Nonuniform expansion of TAVR prostheses resulting in frame deformation, asymmetric leaflet, and smaller neosinus volume is related to occurrence of HALT in patients who undergo TAVR. These data may have implications for both prosthesis valve design and deployment techniques to improve clinical outcomes for these patients.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
BACKGROUND: Randomized clinical trials demonstrated transcatheter edge-to-edge repair (TEER) efficacy in improving outcome vs. medical management for functional mitral regurgitation, but limited randomized data are available for the treatment of degenerative mitral regurgitation (DMR). We aimed to compare the outcome of older patients treated with TEER vs. unoperated DMR. METHODS AND RESULTS: Registries including consecutive patients ≥65 years with symptomatic severe DMR treated with TEER (MitraSwiss and Minneapolis Heart Institute registries) or unoperated (MIDA registry) were analysed. Survival was compared overall and after matching for age, sex, EuroSCORE II, and ejection fraction. The study included 1187 patients (872 treated with TEER and 315 unoperated). During 24 ± 17 months of follow-up, 430 patients died, 18 ± 1% at 1 year and 50 ± 2% at 4 years. Patients undergoing TEER had similar age (82 ± 6 vs. 82 ± 7 years) and sex to unoperated patients, but higher surgical risk/comorbidity (EuroSCORE II 3.98 ± 4.28% vs. 2.77 ± 2.46%), more symptoms, and atrial fibrillation (P < 0.0001). Transcatheter edge-to-edge repair was associated with lower mortality accounting for age, sex, EuroSCORE II, New York Heart Association class, atrial fibrillation, and ejection fraction [hazard ratio (HR): 0.47, 95% confidence interval (CI): 0.37-0.58; P < 0.0001]. After propensity matching (247 pairs of patients), TEER consistently showed better survival compared with unoperated patients (49 ± 6% vs. 37 ± 3% at 4 years, P < 0.0001) even in comprehensive multivariable analysis (HR: 0.60, 95% CI: 0.40-0.91; P = 0.03). Procedural failure was infrequent but post-procedural mitral regurgitation, remaining moderate-to-severe in 66 (7.6%) patients, was associated with excess mortality vs. trivial residual regurgitation (30 ± 6% vs. 11 ± 1% at 1 year, P < 0.0001). CONCLUSION: Amongst older patients with severe symptomatic DMR at high surgical risk, mitral TEER was associated with higher survival vs. unoperated patients. Successful control of mitral regurgitation was key to survival improvement with mitral TEER, which should be actively considered in patients deemed inoperable.
Asunto(s)
Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Volumen Sistólico , Resultado del TratamientoRESUMEN
Saphenous vein grafts (SVGs) remain the most frequently used conduits in coronary artery bypass graft surgery (CABG). Despite advances in surgical techniques and pharmacotherapy, SVG failure rates remain high, often leading to repeat coronary revascularization. The no-touch SVG harvesting technique (minimal graft manipulation with preservation of vasa vasorum and nerves) reduces the risk of SVG failure, whereas the effect of the off-pump technique on SVG patency remains unclear. Use of buffered storage solutions, intraoperative graft flow measurement, careful selection of the target vessels, and physiological assessment of the native coronary circulation before CABG may also reduce the incidence of SVG failure. Perioperative aspirin and high-intensity statin administration are the cornerstones of secondary prevention after CABG. Dual antiplatelet therapy is recommended for off-pump CABG and in patients with a recent acute coronary syndrome. Intermediate (30%-60%) SVG stenoses often progress rapidly. Stenting of intermediate SVG stenoses failed to improve outcomes; hence, treatment focuses on strict control of coronary artery disease risk factors. Redo CABG is associated with higher perioperative mortality compared with percutaneous coronary intervention (PCI); hence, the latter is preferred for most patients requiring repeat revascularization after CABG. SVG PCI is limited by high rates of no-reflow and a high incidence of restenosis during follow-up. Drug-eluting and bare metal stents provide similar long-term outcomes in SVG PCI. Embolic protection devices reduce no-reflow and should be used when feasible. PCI of the corresponding native coronary artery is associated with better short- and long-term outcomes and is preferred over SVG PCI, if technically feasible.
Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Vena Safena/trasplante , Animales , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/diagnóstico , Manejo de la Enfermedad , Humanos , Atención Perioperativa/métodos , Insuficiencia del Tratamiento , Resultado del TratamientoRESUMEN
OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Vena Cava Inferior/diagnóstico por imagenRESUMEN
AIMS: The commonly used valve-in-valve (VIV) app recommends sizing based on dimensions of both the transcatheter heart valve (THV) and bioprosthetic surgical valve. The implications of hydrodynamic testing to guide VIV sizing are poorly understood. This bench study assessed the hydrodynamic performance of different sizes of self-expanding supra-annular THVs in three different surgical aortic bioprostheses at different implantation depths. METHODS: A small versus medium ACURATE neo (ACn), and a 26 mm versus 29 mm Evolut R were assessed after VIV implantation in 25 mm Mitroflow, Mosaic, and Magna Ease aortic surgical bioprostheses, at three implantation depths (+2 mm, -2 mm, and -6 mm). RESULTS: The medium-sized ACn had lower gradients compared to the small ACn when the THV was implanted high (+2 mm, or -2 mm). The 29 mm Evolut R had lower gradients compared to a 26 mm Evolut R for all implantation depths, except for a depth of -2 mm in the 25 mm Mitroflow. The medium ACn and 29 mm Evolut R had larger effective orifice areas compared to the small ACn and 26 mm Evolut R, respectively. Both Evolut R sizes had acceptable regurgitant fractions (<15%), while both ACn sizes were above the acceptable performance criteria (>15%), at all implantation depths. CONCLUSIONS: Use of a larger self-expanding THV was associated with superior hydrodynamic performance if the THV was implanted high. Hydrodynamic testing can provide additional information to the VIV app to help guide VIV sizing.
Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Cateterismo Cardíaco/efectos adversos , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/fisiopatología , Humanos , Hidrodinámica , Ensayo de Materiales , Diseño de Prótesis , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
Transcatheter aortic valve replacement (TAVR) is not currently approved for pure native valve aortic incompetence, and is typically performed on a compassionate basis in selected patients who are at high risk for conventional surgery. We describe the first use of TAVR to treat iatrogenic severe acute pure aortic incompetence following mitral valve surgery. A 71-year-old gentleman developed life-threatening acute aortic regurgitation (AR) within hours of a very challenging fifth open heart mitral valve replacement. Careful inspection of echocardiographic and computed tomographic imaging identified the cause as a disrupted left coronary cusp at the commissure caused by the surgical mitral annular reconstruction. Medical management with afterload reduction failed with recurrent pulmonary edema, and a sixth open heart surgery was deemed prohibitively high risk. The lack of aortic annular calcium onto which anchors a transcatheter valve was a concern for TAVR. However, we postulated that the struts of the mitral valve bioprosthesis would offer some support to the TAVR valve. We opted for a self-expanding system because of concerns about potential unfavorable interaction between the balloon onto which balloon-expandable bioprosthesis is mounted and the struts of the mitral bioprosthesis, and because the Evolut R system has additional anchoring points at the crown which might enhance transcatheter valve stability in the non-calcified annulus, compared with the Edwards Sapien system. Transfemoral TAVR, performed with a Medtronic Evolut R 34 mm system under general anesthesia and using moderately rapid ventricular pacing, was successful with minimal residual AR. On follow-up 1 month later the patient was asymptomatic, and the aortic and mitral bioprostheses were functioning normally on echocardiogram.
Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Bioprótesis , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del TratamientoRESUMEN
Transcatheter aortic valve replacement (TAVR) has emerged as a preferred treatment modality for aortic stenosis, marking a significant advancement in cardiac interventions. Transcatheter heart valves (THVs) have also received approval for treating failed bioprosthetic valves and rings across aortic, mitral, tricuspid, and pulmonic positions. Unlike surgically implanted valves, which are sewn into the annulus, THVs are anchored through relative oversizing. Although THVs are designed to function optimally in a fully expanded state, they exhibit a certain degree of tolerance to underexpansion. However, significant deformation beyond this tolerance can adversely affect the valve's hemodynamics and durability, ultimately impacting patient outcomes. Such post-implantation deviations from the valve's intended three-dimensional design are influenced by a variety of physiological and anatomical factors unique to each patient and procedure, leading to underexpansion, eccentric expansion, and vertical deformation. These deformation patterns increase leaflet stress and strain, potentially causing fatigue and damage. This review article delves into the extent of THV deformation, its impact on leaflet function, hypoattenuating leaflet thickening, and structural valve degeneration. It provides an in-depth analysis of deformation specifics in different procedural contexts, including TAVR in native aortic stenosis, aortic and mitral valve-in-valve procedures, and redo-TAVR. Additionally, the review discusses strategies to mitigate THV deformation during the procedure, offering insights into potential solutions to these challenges.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de PrótesisRESUMEN
Background: Bioprosthetic valve fracture (BVF) during valve-in-valve TAVR (transcatheter aortic valve replacement) is a procedural adjunct designed to optimize the expansion of the transcatheter heart valve and reduce patient-prosthesis mismatch by using a high-pressure balloon to intentionally fracture the surgical heart valve (SHV). Methods: We performed bench testing on 15 bioprosthetic SHV to examine the optimal balloon size and pressure for BVF. We assessed morphological changes and expansion of SHV by computed tomography angiography. Successful BVF was defined as balloon waist disappearance on fluoroscopy and/or sudden pressure drop during balloon inflation. Results: Nine valves met the definition of BVF, 3 of which were confirmed by disruption of the stent frame. We classified surgical valves into 3 subsets: 1) fracturable with metal stent frame (MSF), 2) fracturable with polymer stent frame (PSF) and 3) nonfracturable. In general, valves with MSF were fractured using a balloon size = true internal diameter plus 3-5 mm inflated at high pressure (16-20 ATM) whereas valves with PSF could be fractured with a balloon size = true internal diameter plus 3-5 mm and lower balloon pressure (6-14 ATM). Gains in computed tomography angiography derived inflow area after BVF were 12.3% for MSF and 3.6% for PSF SHV. Conclusions: Gains in CT-determined valve area after BVF depend on the physical properties of the SHV, which in turn influences pressure thresholds and balloon sizing strategy for optimal BVF. Elastic recoil of PSF valves limits the gains in inflow area after BVF.
RESUMEN
BACKGROUND: Quantification of myocardial changes in severe aortic stenosis (AS) is prognostically important. The potential for comprehensive myocardial assessment pre-transcatheter aortic valve replacement (TAVR) by computed tomography angiography (CTA) is unknown. OBJECTIVES: This study sought to evaluate whether quantification of left ventricular (LV) extracellular volume-a marker of myocardial fibrosis-and global longitudinal strain-a marker of myocardial deformation-at baseline CTA associate with post-TAVR outcomes. METHODS: Consecutive patients with symptomatic severe AS between January 2021 and June 2022 who underwent pre-TAVR CTA were included. Computed tomography extracellular volume (CT-ECV) was derived from septum tracing after generating the 3-dimensional CT-ECV map. Computed tomography global longitudinal strain (CT-GLS) used semi-automated feature tracking analysis. The clinical endpoint was the composite outcome of all-cause mortality and heart failure hospitalization. RESULTS: Among the 300 patients (80.0 ± 9.4 years of age, 45% female, median Society of Thoracic Surgeons Predicted Risk of Mortality score 2.80%), the left ventricular ejection fraction (LVEF) was 58% ± 12%, the median CT-ECV was 28.5% (IQR: 26.2%-32.1%), and the median CT-GLS was -20.1% (IQR: -23.8% to -16.3%). Over a median follow-up of 16 months (IQR: 12-22 months), 38 deaths and 70 composite outcomes occurred. Multivariable Cox proportional hazards model, accounting for clinical and echocardiographic variables, demonstrated that CT-ECV (HR: 1.09 [95% CI: 1.02-1.16]; P = 0.008) and CT-GLS (HR: 1.07 [95% CI: 1.01-1.13]; P = 0.017) associated with the composite outcome. In combination, elevated CT-ECV and CT-GLS (above median for each) showed a stronger association with the outcome (HR: 7.14 [95% CI: 2.63-19.36]; P < 0.001). CONCLUSIONS: Comprehensive myocardial quantification of CT-ECV and CT-GLS associated with post-TAVR outcomes in a contemporary low-risk cohort with mostly preserved LVEF. Whether these imaging biomarkers can be potentially used for the decision making including timing of AS intervention and post-TAVR follow-up will require integration into future clinical trials.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda , Volumen Sistólico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo-transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P<0.05). CT-sizing increased redo-TAV feasibility by +8% at node-6, +10% at node-5, and +4% at node-4. Redo-TAV feasibility increased with annulus size, sinotubular junction dimensions, coronary heights, index Evolut size, deeper Evolut implant depth, and lower NSP levels (all P<0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estudios de Factibilidad , Prótesis Valvulares Cardíacas , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Riesgo , Estudios Retrospectivos , Reoperación , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: Assessment of coronary artery disease (CAD) is critical in managing severe aortic stenosis. Unplanned coronary angiography after TAVR, with or without percutaneous coronary intervention, may present significant challenges. OBJECTIVES: The aim of this study was to evaluate the incidence, predictors, and outcomes of unplanned coronary angiography after transcatheter aortic valve replacement (TAVR). METHODS: All TAVR procedures between July 2015 and December 2021 were examined for the occurrence of unplanned angiography and for procedural success with percutaneous coronary intervention if attempted, and a machine learning prediction model was created. RESULTS: Among 1,444 patients (median age 81 years, 59% men), 6.7% had unplanned post-TAVR angiography, 45% within the first year. The most common indication was acute coronary syndrome, which occurred in 3.3% overall. Patients with preprocedural CAD (50.1%) had a significantly higher incidence of unplanned angiography (10.5% vs 2.9%; P < 0.001) in comparison with others. In multivariable analysis, factors associated with unplanned angiography were age (>75 years; HR: 0.46; 95% CI: 0.30-0.71; P < 0.001), mean aortic valve gradient (HR: 0.82; 95% CI: 0.68-0.98; P = 0.031), dialysis (HR: 2.68; 95% CI: 1.07-6.74; P = 0.036), and CAD (HR: 2.96; 95% CI: 1.76-4.98; P < 0.001). In multivariate models, these same variables had areas under the curve of 0.71 to 0.77 for 5-year prediction of unplanned angiography. CONCLUSIONS: Unplanned angiography post-TAVR occurs in about 1 in 15 patients, with about one-half occurring within the first year, about one-half due to acute coronary syndrome, and pre-existing CAD being the strongest predictor. For those considering TAVR and who have or are at risk for CAD, a comprehensive strategy to facilitate lifetime management is needed.
RESUMEN
Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.
Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Toma de Decisiones Clínicas , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Terminología como Asunto , Valor Predictivo de las PruebasRESUMEN
BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.
Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Tomografía Computarizada por Rayos X/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Anciano de 80 o más Años , Cuidados Preoperatorios/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodosRESUMEN
BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodosRESUMEN
Tricuspid regurgitation (TR) is a highly prevalent and heterogeneous valvular disease, independently associated with excess mortality and high morbidity in all clinical contexts. TR is profoundly undertreated by surgery and is often discovered late in patients presenting with right-sided heart failure. To address the issue of undertreatment and poor clinical outcomes without intervention, numerous structural tricuspid interventional devices have been and are in development, a challenging process due to the unique anatomic and physiological characteristics of the tricuspid valve, and warranting well-designed clinical trials. The path from routine practice TR detection to appropriate TR evaluation, to conduction of clinical trials, to enriched therapeutic possibilities for improving TR access to treatment and outcomes in routine practice is complex. Therefore, this paper summarizes the key points and methods crucial to TR detection, quantitation, categorization, risk-scoring, intervention-monitoring, and outcomes evaluation, particularly of right-sided function, and to clinical trial development and conduct, for both interventional and surgical groups.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Diagnóstico por Imagen , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Ensayos Clínicos como AsuntoRESUMEN
BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.
Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de RegistrosRESUMEN
BACKGROUND: Consensus-driven criteria have recently been proposed for prediction of mitral transcatheter edge-to-edge repair outcomes, yet validation for response to therapy is needed. We examined the relation between contemporary criteria and outcomes with mitral transcatheter edge-to-edge repair therapy. METHODS: Mitral transcatheter edge-to-edge repair patients were classified according to anatomic and clinical criteria (1) Heart Valve Collaboratory criteria for nonsuitability; (2) commercial indications (suitable); and (3) neither (ie, intermediate). Analyses for Mitral Valve Academic Research Consortium-defined outcomes of reduction in mitral regurgitation and survival were performed. RESULTS: Among 386 patients (median age, 82 years; 48% women), the most common classification was intermediate (46%), with 138 patients (36%) and 70 patients (18%) in the suitable and nonsuitable categories, respectively. Nonsuitable classification was related to prior valve surgery, smaller mitral valve area, type IIIa morphology, larger coaptation depth, and shorter posterior leaflet. Nonsuitable classification was associated with less technical success (P<0.001) and survival free of mortality, heart failure hospitalization, and mitral surgery (P<0.001). Among the nonsuitable patients, technical failure or any 30-day major adverse cardiac event occurred in 25.7%. Nevertheless, in these patients, acceptable mitral regurgitation reduction without adverse events still occurred in 69%, and their 1-year survival with mild or no symptoms was 52%. CONCLUSIONS: Contemporary classification criteria identify patients less suitable for mitral transcatheter edge-to-edge repair with respect to acute procedural success and survival, though patients most commonly fit an intermediate category. In experienced centers, sufficient mitral regurgitation reduction can be achieved safely in the selected patients even with challenging anatomy.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversosRESUMEN
OBJECTIVE: We sought to determine outcomes of aortic valve replacement (AVR) versus root replacement after transcatheter AVR (TAVR) explantation because they remain unknown. METHODS: From November 2009 to September 2020, data from the EXPLANT-TAVR International Registry of patients who underwent TAVR explant were retrospectively reviewed, divided by AVR versus root replacement. After excluding explants performed during the same admission as the initial TAVR and concomitant procedures involving the other valves, 168 AVR cases were compared with 28 root replacements, and outcomes were reported at 30 days and 1 year. RESULTS: Among 196 patients (mean age, 73.5 ± 9.9 years) who had primary aortic valve intervention at TAVR explant, the median time from TAVR to surgical explant was 11.2 months (interquartile range, 4.4-32.9 months). Indications for explant were similar between the 2 groups. Compared with AVR, patients requiring root replacement had fewer comorbidities but more unfavorable anatomy for redo TAVR (52.6% vs 26.4%; P = .032), fewer urgent/emergency cases (32.1% vs 58.3%; P = .013), longer median interval from index TAVR to TAVR explant (17.6 vs 9.9 months; P = .047), and more concomitant ascending aortic replacement (58.8% vs 14.0%; P < .001). Median follow-up was 6.9 months (interquartile range, 1.4-21.6 months) after TAVR explant and 97.4% complete. Overall survival at follow-up was 81.2% with no differences between groups (log rank P = .54). In-hospital, 30-day, and 1-year mortality rates and stroke rates were not different between the 2 groups. CONCLUSIONS: In the EXPLANT-TAVR Registry, AVR and root replacement groups had different clinical characteristics, but no differences in short-term mortality and morbidities. Further investigations are necessary to identify patients at risk of root replacement in TAVR explant.