Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37638389

RESUMEN

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Frecuencia Cardíaca/fisiología , Bloqueo Cardíaco
2.
Circulation ; 143(3): 212-226, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33169628

RESUMEN

BACKGROUND: Fast ventricular tachycardias (VTs) have historically been attributed to shorter path lengths with smaller reentrant circuit dimensions in animal models. The relationship between the dimensions of the reentrant VT circuit and tachycardia cycle length (TCL) has not been examined in humans. This study aimed to analyze the determinants of the rate of human VT with comparison of circuit dimensions and conduction velocity (CV) across a wide range of both stable and unstable VTs delineated by high-resolution mapping. METHODS: Fifty-four VTs with complete circuit delineation (>90% TCL) by high-resolution multielectrode mapping were analyzed in 49 patients (men, 88%; age, 65 years [58-71 years]; nonischemic, 47%). Fast VT was defined as TCL <333 milliseconds (rate >180 bpm). Unstable VT was defined by hemodynamic deterioration with an intrinsic mean arterial pressure <60 mm Hg during a sustained episode. RESULTS: The median TCL of VT was 365 milliseconds (306-443 milliseconds), and 24 fast VTs were characterized. A wide range of CVs was observed within the entrance (0.03-0.55 m/s), common pathway (0.03-0.77 m/s), exit (0.03-0.53 m/s), and outer loop (0.17-1.13 m/s). There were no significant differences in the median dimensions of the isthmus and path length between fast and slow VTs and between unstable and stable VTs. The outer loop CV was the only circuit component that correlated with TCL in both ischemic cardiomyopathy (r=-0.5, P=0.006) and nonischemic cardiomyopathy (r=-0.45, P=0.028). The duration of the longest diastolic electrogram was inversely correlated with the dimensions of common pathway (length: r=-0.46, P=0.001, width: r=-0.3, P=0.047) and predictive of rapid VT termination by a single radiofrequency application (r=-0.41, P=0.023). CONCLUSIONS: Because of a wide spectrum of CV observed within the reentrant path during human VT, the dimensions of the circuit were not predictive of VT cycle length. For the first time, we demonstrate that the CV of the outer loop, rather than isthmus, is the principal determinant of the rate of VT. The size of the circuit was similar between fast and slow VTs and between unstable and stable VTs. Long, continuous electrograms were indicative of spatially confined isthmus dimensions, confirmed by rapid termination of VT during radiofrequency delivery.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Anciano , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/cirugía
3.
Pacing Clin Electrophysiol ; 44(9): 1549-1561, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34245025

RESUMEN

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity and mortality making the identification of the causative organism critical. The vast majority of CIED infections are caused by Staphylococcal species. CIED infections associated with atypical pathogens are rare and have not been systematically investigated. The objective of this study is to characterize the clinical course, management and outcome in patients with CIED infection secondary to atypical pathogens. METHODS: Medical records of all patients who underwent CIED system extraction at the University of Chicago Medical Center between January 2010 and November 2020 were retrospectively reviewed to identify patients with CIED infection. Demographic, clinical, infection-related and outcome data were collected. CIED infections were divided into typical and atypical groups based on the pathogens isolated. RESULTS: Among 356 CIED extraction procedures, 130 (37%) were performed for CIED infection. Atypical pathogens were found in 5.4% (n = 7) and included Pantoea species (n = 2), Kocuria species (n = 1), Cutibacterium acnes (n = 1), Corynebacterium tuberculostearicum (n = 1), Corynebacterium striatum (n = 1), Stenotrophomonas maltophilia (n = 1), and Pseudozyma ahidis (n = 1). All patients with atypical CIED infections were successfully treated with total system removal and tailored antibiotic therapy. There were no infection-related deaths. CONCLUSIONS: CIED infections with atypical pathogens were rare and associated with good outcome if diagnosed early and treated with total system removal and tailored antimicrobial therapy. Atypical pathogens cultured from blood, tissue or hardware in patients with CIED infection should be considered pathogens and not contaminants.


Asunto(s)
Antibacterianos/uso terapéutico , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/terapia , Anciano , Terapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
Indian Pacing Electrophysiol J ; 21(2): 124-127, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33271274

RESUMEN

Permanent pacemaker (PPM) malfunction due to electrical connection problems such as a loose set screw or lead-header malapposition is extremely rare. We present a patient with complete heart block (CHB) who had PPM malfunction and recurrent syncope, late (14 months) after initial implantation, which was caused by the ventricular lead pin disengagement from the header resulting in oversensing due to noise, pacing inhibition and recurrent syncope. PPM due to lead-header malapposition this late after device implantation has previously not been reported.

5.
Circulation ; 140(17): 1383-1397, 2019 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-31533463

RESUMEN

BACKGROUND: Accurate and expedited identification of scar regions most prone to reentry is needed to guide ventricular tachycardia (VT) ablation. We aimed to prospectively assess outcomes of VT ablation guided primarily by the targeting of deceleration zones (DZ) identified by propagational analysis of ventricular activation during sinus rhythm. METHODS: Patients with scar-related VT were prospectively enrolled in the University of Chicago VT Ablation Registry between 2016 and 2018. Isochronal late activation maps annotated to the latest local electrogram deflection were created with high-density multielectrode mapping catheters. Targeted ablation of DZ (>3 isochrones within 1cm radius) was performed, prioritizing later activated regions with maximal isochronal crowding. When possible, activation mapping of VT was performed, and successful ablation sites were compared with DZ locations for mechanistic correlation. Patients were prospectively followed for VT recurrence and mortality. RESULTS: One hundred twenty patients (median age 65 years [59-71], 15% female, 50% nonischemic, median ejection fraction 31%) underwent 144 ablation procedures for scar-related VT. 57% of patients had previous ablation and epicardial access was employed in 59% of cases. High-density mapping during baseline rhythm was performed (2518 points [1615-3752] endocardial, 5049±2580 points epicardial) and identified an average of 2±1 DZ, which colocalized to successful termination sites in 95% of cases. The median total radiofrequency application duration was 29 min (21-38 min) to target DZ, representing ablation of 18% of the low-voltage area. At 12±10 months, 70% freedom from VT recurrence (80% in ischemic cardiomyopathy and 63% in nonischemic cardiomyopathy) was achieved. The overall survival rate was 87%. CONCLUSIONS: A novel voltage-independent high-density mapping display can identify the functional substrate for VT during sinus rhythm and guide targeted ablation, obviating the need for extensive radiofrequency delivery. Regions with isochronal crowding during the baseline rhythm were predictive of VT termination sites, providing mechanistic evidence that deceleration zones are highly arrhythmogenic, functioning as niduses for reentry.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Mapeo del Potencial de Superficie Corporal , Cardiomiopatías/fisiopatología , Taquicardia Ventricular/fisiopatología , Anciano , Arritmias Cardíacas/terapia , Mapeo del Potencial de Superficie Corporal/métodos , Cardiomiopatías/terapia , Ablación por Catéter/métodos , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/terapia , Taquicardia Ventricular/terapia
6.
Circulation ; 139(16): 1876-1888, 2019 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-30704273

RESUMEN

BACKGROUND: Septal activation in patients with left bundle-branch block (LBBB) patterns has not been described previously. We performed detailed intracardiac mapping of left septal conduction to assess for the presence and level of complete conduction block (CCB) in the His-Purkinje system. Response to His bundle pacing was assessed in patients with and without CCB in the left bundle. METHODS: Left septal mapping was performed with a linear multielectrode catheter in consecutive patients with LBBB pattern referred for device implantation (n=38) or substrate mapping (n=47). QRS width, His duration, His-ventricular (HV) intervals, and septal conduction patterns were analyzed. The site of CCB was localized to the level of the left-sided His fibers (left intrahisian) or left bundle branch. Patients with ventricular activation preceded by Purkinje potentials were categorized as having intact Purkinje activation. RESULTS: A total of 88 left septal conduction recordings were analyzed in 85 patients: 72 LBBB block pattern and 16 controls (narrow QRS, n=11; right bundle-branch block, n=5). Among patients with LBB block pattern, CCB within the proximal left conduction system was observed in 64% (n=46) and intact Purkinje activation in the remaining 36% (n=26). Intact Purkinje activation was observed in all controls. The site of block in patients with CCB was at the level of the left His bundle in 72% and in the proximal left bundle branch in 28%. His bundle pacing corrected wide QRS in 54% of all patients with LBBB pattern and 85% of those with CCB (94% left intrahisian, 62% proximal left bundle-branch). No patients with intact Purkinje activation demonstrated correction of QRS with His bundle pacing. CCB showed better predictive value (positive predictive value 85%, negative predictive value 100%, sensitivity 100%) than surface ECG criteria for correction with His bundle pacing. CONCLUSIONS: Heterogeneous septal conduction was observed in patients with surface LBBB pattern, ranging from no discrete block to CCB. When block was present, we observed pathology localized within the left-sided His fibers (left intrahisian block), which was most amenable to corrective His bundle pacing by recruitment of latent Purkinje fibers. ECG criteria for LBBB incompletely predicted CCB, and intracardiac data might be useful in refining patient selection for resynchronization therapy.


Asunto(s)
Fascículo Atrioventricular/fisiología , Bloqueo de Rama/diagnóstico , Técnicas de Imagen Cardíaca/métodos , Electrocardiografía/métodos , Tabiques Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/diagnóstico , Ramos Subendocárdicos/fisiología , Anciano , Fascículo Atrioventricular/diagnóstico por imagen , Catéteres Cardíacos , Terapia de Resincronización Cardíaca , Estudios de Cohortes , Femenino , Frecuencia Cardíaca , Tabiques Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Pronóstico
7.
Pacing Clin Electrophysiol ; 43(5): 527-533, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32259298

RESUMEN

Conventional treatment strategies for catecholaminergic polymorphic ventricular tachycardia (CPVT) include avoidance of strenuous exercise and competitive sports, drugs such as ß-blockers and flecainide and, cervical sympathectomy. An implantable cardioverter-defibrillator (ICD) has been utilized if the response to these strategies is inadequate; however, ICD use in CPVT patients, in addition to usual complications, is associated with an increased risk of life-threatening electrical storm. Ivabradine is a selective inhibitor of hyperpolarization-activated cyclic nucleotide-gated potassium channel 4 generated funny current (If ), which has been shown to be efficacious in suppression of inappropriate sinus tachycardia, junctional tachycardia, atrial tachycardia, and ventricular ectopy in humans. We report an 18-year-old male with a severe CPVT phenotype refractory to flecainide, nadolol, and sympathectomy who exhibited suppression of ventricular arrhythmias after initiation of ivabradine. These findings are of importance as ivabradine could be an important add-on therapy in CPVT patients who are drug refractory or are unable to continue conventional therapies at the recommended doses.


Asunto(s)
Fármacos Cardiovasculares/uso terapéutico , Ivabradina/uso terapéutico , Taquicardia Ventricular/tratamiento farmacológico , Adolescente , Electrocardiografía , Prueba de Esfuerzo , Flecainida/uso terapéutico , Humanos , Masculino , Nadolol/uso terapéutico , Fenotipo , Simpatectomía , Taquicardia Ventricular/cirugía
8.
J Cardiovasc Electrophysiol ; 30(2): 183-192, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30516301

RESUMEN

INTRODUCTION: Ventricular arrhythmias (VA) after left ventricular assist device (LVAD) placement are associated with increased morbidity and mortality. We sought to assess epicardial voltage characteristics at the time of LVAD implantation and investigate relationships between scar burden and postimplant VA. METHODS AND RESULTS: Consecutive patients underwent open chest epicardial electroanatomic mapping immediately before LVAD implantation. Areas of low voltage and sites with local abnormal potentials were identified. Patients were followed prospectively for postimplant VA and clinical outcomes. Between 2015 and 2017, 36 patients underwent high-density intraoperative epicardial voltage mapping; 15 had complete maps suitable for analysis. Mapping required a median of 11.8 (interquartile range [IQR], 8.5-12.7) minutes, with a median of 2650 (IQR, 2139-3191) points sampled per patient. Over a median follow-up of 311 (IQR, 168-469) postoperative days, four patients (27%) experienced sustained VA. Patients with postimplant VA were more likely to have had preimplant implantable cardioverter defibrillator shocks (100% vs 27%; P = 0.03), ventricular tachycardia storm (75% vs 9%; P = 0.03), and lower ejection fraction (13.5 vs 19.0%, P = 0.05). Patients with postimplant VA also had a significantly higher burden of epicardial low bipolar voltage points: 55.4% vs 24.9% of points were less than 0.5 mV (P = 0.01), and 88.9% vs 63.7% of points less than 1.5 mV (P = 0.004). CONCLUSIONS: Intraoperative high-density epicardial mapping during LVAD implantation is safe and efficient, facilitating characterization of a potentially arrhythmogenic substrate. An increased burden of the epicardial scar may be associated with a higher incidence of postimplant VA. The role of empiric intraoperative epicardial ablation to mitigate risk of postimplant VA requires further study.


Asunto(s)
Arritmias Cardíacas/etiología , Cicatriz/complicaciones , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Pericardio/fisiopatología , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Potenciales de Acción , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Cicatriz/diagnóstico , Cicatriz/fisiopatología , Mapeo Epicárdico , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pericardio/patología , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
9.
Pacing Clin Electrophysiol ; 42(8): 1146-1154, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30912151

RESUMEN

We report a 17-year-old boy with a large RYR2 exon 3 deletion who has a severe catecholaminergic polymorphic ventricular tachycardia (CPVT) phenotype characterized by refractoriness to both nadolol and flecainide which has previously not been reported in this subgroup of CPVT patients. Treatment options in a patient like ours are therefore limited and sympathectomy and implantable cardioverter-defibrillator implantation should be considered early in the treatment course as was done in this patient. In contrast to other CPVT patients who do not usually have structural cardiac abnormalities, these patients are at a high risk of developing left ventricular noncompaction or dilated cardiomyopathy and therefore might benefit from cardiac imaging at regular intervals.


Asunto(s)
Antiarrítmicos/uso terapéutico , Exones , Flecainida/uso terapéutico , Eliminación de Gen , Nadolol/uso terapéutico , Canal Liberador de Calcio Receptor de Rianodina/genética , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/genética , Adolescente , Humanos , Masculino
10.
Pacing Clin Electrophysiol ; 41(9): 1158-1164, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29931776

RESUMEN

BACKGROUND: The relationship between high-grade atrioventricular block (HGAVB) with cumulative frequent pacing and risk of atrial arrhythmias (AAs) has not been well characterized. We hypothesized HGAVB and pacing may have significant impact on incidence and prevalence of AAs by modulating atrial substrate. OBJECTIVE: To determine impact of HGAVB and pacing on AAs including atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT). METHODS: All consecutive patients who underwent dual-chamber pacemaker implantation for HGAVB from 2005 to 2011 at the University of Chicago were included. AAs and percent of pacing were detected through device interrogation. Patients' data were collected from electronic medical records and clinic visits. RESULTS: A total of 166 patients (mean age 71 ± 15 years; 54% female, 56% African American) were studied. AF was documented in 27% of patients before pacemaker implantation. During a mean 5.8 ± 2.2 years of follow-up, 47% had device-detected AF, 10% AFL, and 26% AT. New-onset AF was documented in 40 of the 122 patients without prior AF (33%). Continuous (≥ 99%) right ventricular pacing was associated with significantly decreased AF prevalence (34% vs 59%, P = 0.005), and correlated with lower incidence (26% vs 41%, P = 0.22). Pacing suppressed AF in 14% of patients with baseline AF; those patients had lower atrial pacing (3.2% vs 45%, P < 0.0001). Left atrial dilation was the only independent predictor of AF with frequent pacing (P = 0.009). CONCLUSIONS: HGAVB is associated with high incidence and prevalence of AAs with and without pacing. Cumulative frequent (≥99%) ventricular pacing reduces risk of AF in patients with HGAVB.


Asunto(s)
Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Aleteo Atrial/etiología , Aleteo Atrial/fisiopatología , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/epidemiología , Aleteo Atrial/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevalencia
14.
Ann Thorac Surg Short Rep ; 2(1): 150-155, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38464466

RESUMEN

BACKGROUND: We have developed a tissue engineered cardiac patch derived from a 3-dimensional (3D) myocardial tissue reinforced with extracellular matrix in an effort to enhance in situ myocardial regeneration. The feasibility of the patch was evaluated in a porcine model by various modalities to assess both the constructive and functional aspects of regeneration. METHODS: A spheroid-based 3D multicellular tissue was created using a 3D net mold system that incorporated cardiomyocytes and embryonic fibroblast cells. The 3D multicellular tissue was incorporated with extracellular matrix sheets and surgically implanted into the right ventricle of a healthy porcine model (n = 4). After 60 days, the implanted patches were evaluated by cardiac magnetic resonance imaging and electroanatomic mapping studies as well as by post-euthanasia analyses, including measurements of mechanical viscoelasticity. RESULTS: Cardiac magnetic resonance imaging revealed improved regional tissue perfusion in the patch area. Electroanatomic mapping exhibited regenerated electrical conductivity in the patch, as evidenced by relatively preserved voltage regions (1.11 ± 0.8 mV) in comparison to the normal right ventricle (4.7 ± 2.8 mV). Histologic and tissue analyses confirmed repopulation of site-specific host cells, including premature cardiomyocytes and active vasculogenesis. These findings were supported by quantitative reverse transcription-polymerase chain reaction. CONCLUSIONS: The tissue engineered cardiac patch effectively facilitated in situ constructive and functional myocardial regeneration, characterized by increased regional tissue perfusion and positive electrical activity in the porcine model.

15.
JAMA Cardiol ; 9(5): 449-456, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38536171

RESUMEN

Importance: Current left bundle branch block (LBBB) criteria are based on animal experiments or mathematical models of cardiac tissue conduction and may misclassify patients. Improved criteria would impact referral decisions and device type for cardiac resynchronization therapy. Objective: To develop a simple new criterion for LBBB based on electrophysiological studies of human patients, and then to validate this criterion in an independent population. Design, Setting, and Participants: In this diagnostic study, the derivation cohort was from a single-center, prospective study of patients undergoing electrophysiological study from March 2016 through November 2019. The validation cohort was assembled by retrospectively reviewing medical records for patients from the same center who underwent transcatheter aortic valve replacement (TAVR) from October 2015 through May 2022. Exposures: Patients were classified as having LBBB or intraventricular conduction delay (IVCD) as assessed by intracardiac recording. Main Outcomes and Measures: Sensitivity and specificity of the electrocardiography (ECG) criteria assessed in patients with LBBB or IVCD. Results: A total of 75 patients (median [IQR] age, 63 [53-70.5] years; 21 [28.0%] female) with baseline LBBB on 12-lead ECG underwent intracardiac recording of the left ventricular septum: 48 demonstrated complete conduction block (CCB) and 27 demonstrated intact Purkinje activation (IPA). Analysis of surface ECGs revealed that late notches in the QRS complexes of lateral leads were associated with CCB (40 of 48 patients [83.3%] with CCB vs 13 of 27 patients [48.1%] with IPA had a notch or slur in lead I; P = .003). Receiver operating characteristic curves for all septal and lateral leads were constructed, and lead I displayed the best performance with a time to notch longer than 75 milliseconds. Used in conjunction with the criteria for LBBB from the American College of Cardiology/American Heart Association/Heart Rhythm Society, this criterion had a sensitivity of 71% (95% CI, 56%-83%) and specificity of 74% (95% CI, 54%-89%) in the derivation population, contrasting with a sensitivity of 96% (95% CI, 86%-99%) and specificity of 33% (95% CI, 17%-54%) for the Strauss criteria. In an independent validation cohort of 46 patients (median [IQR] age, 78.5 [70-84] years; 21 [45.7%] female) undergoing TAVR with interval development of new LBBB, the time-to-notch criterion demonstrated a sensitivity of 87% (95% CI, 74%-95%). In the subset of 10 patients with preprocedural IVCD, the criterion correctly distinguished IVCD from LBBB in all cases. Application of the Strauss criteria performed similarly in the validation cohort. Conclusions and Relevance: The findings suggest that time to notch longer than 75 milliseconds in lead I is a simple ECG criterion that, when used in conjunction with standard LBBB criteria, may improve specificity for identifying patients with LBBB from conduction block. This may help inform patient selection for cardiac resynchronization or conduction system pacing.


Asunto(s)
Bloqueo de Rama , Electrocardiografía , Humanos , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
16.
J Am Coll Cardiol ; 82(11): 1096-1105, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-37673510

RESUMEN

BACKGROUND: Factors determining hemodynamic stability during human ventricular tachycardia (VT) are incompletely understood. OBJECTIVES: The purposes of this study were to characterize sinus rate (SR) responses during monomorphic VT in association with hemodynamic stability and to prospectively assess the effects of vagolytic therapy on VT tolerance. METHODS: This is a retrospective analysis of patients undergoing scar-related VT ablation. Vasovagal responses were evaluated by analyzing sinus cycle length before VT induction and during VT. SR responses were classified into 3 groups: increasing (≥5 beats/min, sympathetic), decreasing (≥5 beats/min, vagal), and unchanged, with the latter 2 categorized as inappropriate SR. In a prospective cohort (n = 30) that exhibited a failure to increase SR, atropine was administered to improve hemodynamic tolerance to VT. RESULTS: In 150 patients, 261 VT episodes were analyzed (29% untolerated, 71% tolerated) with median VT duration 1.6 minutes. A total of 52% of VT episodes were associated with a sympathetic response, 31% had unchanged SR, and 17% of VTs exhibited a vagal response. A significantly higher prevalence of inappropriate SR responses was observed during untolerated VT (sustained VT requiring cardioversion within 150 seconds) compared with tolerated VT (84% vs 34%; P < 0.001). Untolerated VT was significantly different between groups: 9% (sympathetic), 82% (vagal), and 32% (unchanged) (P < 0.001). Atropine administration improved hemodynamic tolerance to VT in 70%. CONCLUSIONS: Nearly one-half of VT episodes are associated with failure to augment SR, indicative of an under-recognized pathophysiological vasovagal response to VT. Inappropriate SR responses were more predictive of hemodynamic instability than VT rate and ejection fraction. Vagolytic therapy may be a novel method to augment blood pressure during VT.


Asunto(s)
Taquicardia Ventricular , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Taquicardia Ventricular/terapia , Hemodinámica , Atropina/farmacología , Ubiquitina-Proteína Ligasas
17.
Heart Rhythm O2 ; 3(6Part B): 731-735, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36589010

RESUMEN

Background: Transvenous lead extraction is the standard of care for cardiac implantable electronic device (CIED) malfunction/infection-related removal. However, data on its performance and results in underdeveloped countries are limited. Objective: The purpose of this study was to report the feasibility and efficacy of a lead extraction program in a tertiary hospital in Chile, South America. Methods: Patients requiring CIED removal at the Electrophysiology Division of the Hospital las Higuera's were retrospectively analyzed. Outcomes including procedure-related mortality, procedural success and failure, and cardiac and vascular complications were reported. Results: A total of 15 patients were analyzed (median age 68 [interquartile range 52-75] years; 80% male). Patients with lead extraction difficulty index >10 represented 33% of patients. Infection was the indication for removal in all patients, with pocket infection (80%). Mechanical rotational tools were used in 66% of cases, and a total of 29 leads were removed. Procedural success was accomplished in 93% of cases. There was 1 (7%) intraprocedural complication and no procedure-related mortality. Conclusions: The development of a lead management program is feasible, safe, and effective in underdeveloped countries.

18.
Heart Rhythm ; 19(4): 527-535, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34757186

RESUMEN

BACKGROUND: Catheter ablation strategies for ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT) are not established when spontaneous triggers are rare or absent. OBJECTIVE: The purpose of this study was to report the feasibility and efficacy of a novel empiric ablation strategy of pacemapping to stored implantable cardioverter-defibrillator (ICD) template electrograms (SITE) of the clinical premature ventricular contraction (PVC) trigger. METHODS: Fifteen patients with drug-refractory VF/PMVT receiving defibrillator shocks without identifiable and mappable PVC triggers were prospectively analyzed. The protocol incorporated systematic pacemapping from known arrhythmogenic sites (moderator band/right ventricular [RV] papillary muscles, left conduction system/Purkinje network, outflow tracts) with real-time comparison between the paced ICD electrogram (EGM) morphology and SITE. RESULTS: Regions within the left Purkinje network yielded the best pacemap match for the SITE of the clinical PVC trigger in 55% of ablation targets (left posterior fascicle 6, left septal fascicle 1, left anterior fascicle 5), followed by the RV moderator band region in 14% (n = 3), RV papillary muscles in 13% (n = 3), periaortic region in 14% (n = 3), and left ventricular anterolateral papillary muscle in 4% (n = 1). Freedom from ICD therapies off antiarrhythmic drug (AAD) was 64% at 6 months and 48% at 12 months. Shock burden was reduced from 4 (2-6) to 0 (0-1) (P = .001), and use of AADs was reduced from 2 (1-2) to 0 (0-1) (P = .001). CONCLUSION: In the absence of a mappable trigger, an empiric strategy of interrogating the Purkinje network, papillary muscles, and outflow tract regions by pacemap matching with SITE of the clinical PVC is feasible to guide ablation. A significant reduction in VF/PMVT therapy burden and AAD utilization was observed after a single procedure.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Ablación por Catéter/métodos , Estudios de Factibilidad , Humanos , Estudios Prospectivos , Taquicardia Ventricular/cirugía , Fibrilación Ventricular
19.
JACC Clin Electrophysiol ; 8(5): 651-661, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35589178

RESUMEN

OBJECTIVES: This study sought to analyze the impact of the American College of Cardiology, American Heart Association, and Heart Rhythm Society (ACC/AHA/HRS) guidelines for cardiac resynchronization therapy with defibrillator (CRT-D) update on utilization and efficacy of CRT-D. BACKGROUND: In September 2012, the ACC/AHA/HRS guidelines for CRT-D were modified to include left bundle branch block (LBBB) as a Class I indication. METHODS: The IBM Watson MarketScan Database was queried between January 1, 2003, and December 31, 2018, for CRT-D implants or upgrades. The primary outcome was heart failure (HF) hospitalization following left ventricular lead implant. Secondary outcomes included all-cause mortality and device-related lead revision. RESULTS: A total of 27,238 patients were analyzed: 18,384 pre-update and 8,854 post-update. Mean age was 69 ± 11 years, 73% men, and 98% with history of HF hospitalization. The proportion of patients with LBBB increased from 29% to 55% (P < 0.001) after the update. Patients receiving CRT-D post-update demonstrated a greater prevalence of comorbidities, including atrial fibrillation (47% vs 40%; P < 0.001), diabetes mellitus (45% vs 39%; P < 0.001), chronic kidney disease (24% vs 15%; P < 0.001), and HF hospitalization in the year before CRT-D (40% vs 37%; P < 0.001). Despite greater baseline comorbidities, HF hospitalization significantly declined post-update (HR: 0.89; P < 0.001). Multivariate predictors of reduced HF hospitalization included angiotensin receptor neprilysin inhibitor prescription (HR: 0.48; P < 0.001) and presence of LBBB (HR: 0.71; P < 0.001). All-cause mortality was not significantly different between the 2 groups, and fewer lead revisions were noted post-update (0.6% vs 1.7%; P < 0.001). CONCLUSIONS: The revised 2012 guidelines led to an increased proportion of LBBB patients receiving CRT-D at the population-level. This change was associated with reduced HF hospitalization, despite broadening therapy to patients with more comorbid conditions.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/terapia , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
Cureus ; 13(1): e12702, 2021 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-33604224

RESUMEN

Background The CanGaroo® Envelope (Aziyo Biologics, Silver Spring, MD) is intended to securely hold a cardiovascular implantable electronic device (CIED) to create a stable environment when implanted in the body. Data on the utilization of this newly available product are limited. Objective In this study, our objective was to describe the specific profiles of patients who may benefit from the use of the CanGaroo® Envelope at the time of CIED implantation. Methods  The utilization of the CanGaroo® Envelope was assessed from January 2019 to October 2019 among a series of patients who were either undergoing de-novo CIED implantation or replacement. Results Among a total of 50 patients, the CanGaroo® Envelope was utilized in 15 (30%). Three distinct patient profiles were identified: profile 1: elderly patients with poor tissue turgor at risk of wound dehiscence or erosion; profile 2: patients with a history of previous device infection; and profile 3: patients at high risk of device infection having one or more of the following risk factors - chronic kidney disease, immunocompromised state, or diabetes mellitus. At a mean follow-up of 18 ±3 months, no CIED pocket erosion, dehiscence, or infection was noted. Conclusions Three distinct profiles of patients who could potentially benefit from the use of the CanGaroo® Envelope were identified by the implanting physicians. Long-term follow-up data, including infection and wound dehiscence rates, are necessary to further analyze the optimal utilization of the device.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA