Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Isr Med Assoc J ; 18(2): 104-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26979003

RESUMEN

BACKGROUND: Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). OBJECTIVES: To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. METHODS: During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. RESULTS: Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. CONCLUSIONS: In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.


Asunto(s)
Filtros de Vena Cava , Vena Cava Inferior/cirugía , Tromboembolia Venosa/prevención & control , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Embolia Pulmonar/prevención & control , Estudios Retrospectivos , Factores de Tiempo , Filtros de Vena Cava/efectos adversos , Adulto Joven
2.
J Vasc Interv Radiol ; 25(5): 702-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24582172

RESUMEN

PURPOSE: To describe the transvenous application of intracardiac echocardiography (ICE) for guidance during endovascular aortic repair (EVAR). MATERIALS AND METHODS: Eight patients with an infrarenal abdominal aortic aneurysm (AAA) and chronic renal failure were determined suitable for EVAR. The procedure was performed by deploying the transcaval and transiliac vein guidance of an ICE catheter to reduce the dosage of iodinated contrast medium. Multiple guidance parameters were assessed. The present study describes the EVAR procedure and postprocedure transabdominal ultrasound (US) follow-up results at 3-4 months. RESULTS: The eight procedures were completed by using transvenous ICE guidance. No contrast medium was used in five patients, and 3-20 mL of isoosmolar contrast medium was administered in the other three. No endoleaks were detected by ICE immediately after stent deployment. One patient who had a single functioning kidney developed renal failure that was attributed to manipulation-related cholesterol embolization. That patient became dependent on dialysis and died 3.5 months after the procedure. No endoleaks were detected at 3-4-month US follow-up in the other seven patients. CONCLUSIONS: Transvenous ICE guidance is a promising method to reduce the dosage of iodinated contrast medium in patients with renal dysfunction undergoing EVAR. A prospective trial comparing this modality versus digital subtraction angiography guidance with iodinated contrast medium in terms of safety, accuracy, and long-term efficacy is recommended.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Cateterismo Venoso Central/métodos , Procedimientos Endovasculares/métodos , Fallo Renal Crónico/diagnóstico por imagen , Fallo Renal Crónico/cirugía , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Resultado del Tratamiento
3.
Pediatr Nephrol ; 27(6): 1037-40, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22366877

RESUMEN

BACKGROUND: Hyponatremic hypertensive syndrome (HHS) is characterized by unilateral renal artery stenosis with secondary hypertension and glomerular and tubular dysfunction due to hyperfiltration and activation of the renin-angiotensin system (RAS). CASE-DIAGNOSIS/TREATMENT: We describe four children with HHS. All presented with polyuria and polydipsia, electrolyte disturbances, metabolic alkalosis, variable tubular dysfunction, and nephrotic range proteinuria along with hypertension. Interestingly, in one patient, glomerular and tubular abnormalities preceded the development of hypertension. All symptoms resolved after the underlying renal ischemia was corrected by percutaneous angioplasty. CONCLUSION: Hyponatremic hypertensive syndrome may be more common in children than previously thought. Clinicians should be alert of the signs and symptoms because cure is possible with timely diagnosis and treatment.


Asunto(s)
Hipertensión Renovascular/etiología , Hiponatremia/etiología , Obstrucción de la Arteria Renal/complicaciones , Angioplastia , Biomarcadores/sangre , Biomarcadores/orina , Preescolar , Femenino , Hemodinámica , Humanos , Hipertensión Renovascular/diagnóstico , Hipertensión Renovascular/metabolismo , Hipertensión Renovascular/fisiopatología , Hipertensión Renovascular/terapia , Hiponatremia/diagnóstico , Hiponatremia/metabolismo , Hiponatremia/fisiopatología , Hiponatremia/terapia , Lactante , Masculino , Obstrucción de la Arteria Renal/diagnóstico , Obstrucción de la Arteria Renal/metabolismo , Obstrucción de la Arteria Renal/fisiopatología , Obstrucción de la Arteria Renal/terapia , Sistema Renina-Angiotensina , Síndrome , Resultado del Tratamiento
4.
Sensors (Basel) ; 12(8): 10067-85, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23112588

RESUMEN

Modern "smart" CMOS sensors have penetrated into various applications, such as surveillance systems, bio-medical applications, digital cameras, cellular phones and many others. Reducing the power of these sensors continuously challenges designers. In this paper, a low power global shutter CMOS image sensor with Wide Dynamic Range (WDR) ability is presented. This sensor features several power reduction techniques, including a dual voltage supply, a selective power down, transistors with different threshold voltages, a non-rationed logic, and a low voltage static memory. A combination of all these approaches has enabled the design of the low voltage "smart" image sensor, which is capable of reaching a remarkable dynamic range, while consuming very low power. The proposed power-saving solutions have allowed the maintenance of the standard architecture of the sensor, reducing both the time and the cost of the design. In order to maintain the image quality, a relation between the sensor performance and power has been analyzed and a mathematical model, describing the sensor Signal to Noise Ratio (SNR) and Dynamic Range (DR) as a function of the power supplies, is proposed. The described sensor was implemented in a 0.18 um CMOS process and successfully tested in the laboratory. An SNR of 48 dB and DR of 96 dB were achieved with a power dissipation of 4.5 nW per pixel.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/instrumentación , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Metales/química , Óxidos/química , Relación Señal-Ruido
5.
Isr Med Assoc J ; 14(6): 354-8, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22891395

RESUMEN

BACKGROUND: The presence of stones in the common bile duct (CBD) may cause complications such as obstructing jaundice or ascending cholangitis, and the stones should be removed. OBJECTIVES: To assess the efficacy of percutaneous elimination of CBD stones from the gallbladder through the papilla. METHODS: During a 4 year period, six patients (five men and one woman, mean age 71.5 years) who had CBD stones and an existing gallbladder drain underwent percutaneous stone push into the duodenum after balloon dilatation of the papilla, with a diameter equal to that of the largest stone. Access into the CBD was from the gallbladder, using an already existing percutaneous gallbladder drain (cholecystostomy tube). RESULTS: Each patient had one to three CBD stones measuring 7-14 mm. Successful CBD stone elimination into the duodenum was achieved in five of the six patients. The single failure occurred in a patient with choledochal diverticulum, who was operated successfully. There were no major or minor complications during or after the procedures. CONCLUSIONS: Trans-cholecystic CBD stone elimination is a safe and feasible percutaneous technique that utilizes existing tracts, thus obviating the need to create new percutaneous access. This procedure can replace endoscopic or surgical CBD exploration.


Asunto(s)
Cateterismo/métodos , Colecistostomía , Cálculos Biliares/terapia , Adulto , Anciano de 80 o más Años , Colangiografía , Femenino , Cálculos Biliares/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Resultado del Tratamiento
6.
JACC Case Rep ; 3(2): 212-216, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34317504

RESUMEN

Björk conduit failure is a common reason for reintervention after a Björk modification of the Fontan procedure. We describe a first performed in human percutaneous procedure for the treatment of a failing Björk circuit in an adult with congenital heart disease and complex anatomic features. (Level of Difficulty: Advanced.).

7.
AJR Am J Roentgenol ; 194(6): 1626-9, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20489105

RESUMEN

OBJECTIVE: The purpose of our study was to determine whether pharmacologic thrombolysis with urokinase in the lyse and wait (L&W) technique compared with mechanical declotting using the Arrow-Trerotola percutaneous thrombectomy device is more efficient, safer, or less expensive in treating thrombosed hemodialysis grafts. MATERIALS AND METHODS: The files of 157 patients who underwent arteriovenous graft declotting from 2000 to 2007 at one tertiary care center were reviewed. The study group included 83 women and 74 men with a mean age of 68 +/- 12 years (range, 27-95 years). A total of 563 procedures were performed: 427 with the L&W technique and 136 with mechanical percutaneous thrombectomy using the percutaneous thrombectomy device. The two types of procedures were compared for success rate, complications, average patency time, and cost. RESULTS: There were no statistically significant differences between the pharmacologic and mechanical procedures in immediate success rate (99% and 98%, respectively) or average patency time (5.44 months and 5.40 months, respectively). The L&W technique was considerably less expensive. CONCLUSION: Given its lower cost and equal efficacy and safety, L&W appears to be preferable to mechanical thrombolysis with a percutaneous thrombectomy device for initial arteriovenous hemodialysis graft declotting.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Oclusión de Injerto Vascular/terapia , Activadores Plasminogénicos/administración & dosificación , Diálisis Renal , Trombectomía/instrumentación , Terapia Trombolítica/métodos , Trombosis/terapia , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Oclusión de Injerto Vascular/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/tratamiento farmacológico , Resultado del Tratamiento , Grado de Desobstrucción Vascular
8.
Surg Endosc ; 24(12): 3144-8, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20526628

RESUMEN

BACKGROUND: Accurate localization of small colorectal cancers and polyps during laparoscopic resection may be difficult and requires precise and reliable localization techniques. This study aimed to assess the usefulness of intraoperative ultrasonography (IOUS) combined with retrograde saline instillation in locating small colorectal cancers and polyps during laparoscopically assisted colectomy. METHODS: The study investigated 14 patients with left-sided lesions of the colon and rectum necessitating preoperative marking. During laparoscopically assisted colorectal surgery, the large bowel was filled with saline solution by gravity, then scanned with a 5- to 10-MHz laparoscopic ultrasound probe. RESULTS: In all patients, both polyps and small cancers were clearly detected by IOUS. Furthermore, the technique was found to be easily mastered and performed. The mean detection time was 11 min. Polyps were seen as hypodense masses protruding from the bowel mucosa, whereas invasive cancers had both hypo- and hyperdense regions with sonographically appreciable penetration through bowel layers. CONCLUSION: Intraoperative laparoscopic ultrasonography in conjunction with saline instillation can serve as a useful tool that allows the surgeon to locate small nonpalpable tumors during laparoscopically assisted resection of colorectal cancer.


Asunto(s)
Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Endosonografía , Cuidados Intraoperatorios/métodos , Laparoscopía , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
9.
Catheter Cardiovasc Interv ; 74(2): 278-85, 2009 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-19198011

RESUMEN

OBJECTIVE: To evaluate the feasibility of a new 0.014'' CiTop guidewire to cross total occlusions within normal and diseased blood vessels; proof of concept. BACKGROUND: Despite recent advances, chronic arterial occlusions remain the main obstacle of coronary and peripheral interventions. METHODS: The OVALUM CiTop 0.014'' guidewire is an over-the-wire catheter designed to penetrate through chronic total occlusions (CTO) and allow for further PCI interventions. The CiTop guidewire was tested in normal peripheral and coronary arteries of swine (n = 7) and in totally occluded arterial lesions within human amputations (n = 10). RESULTS: The CiTop 0.014'' guidewire was operated successfully in seven peripheral blood vessels and 12 coronary arteries without angiographic or histological evidence of damage to the arterial wall. The CiTop crossed 9 of the 10 occluded segments within the human amputation with no angiographic or histological evidence of arterial damage (90% success rate). Average time to cross the occlusion was 4.6 +/- 5.6 min. In one artery (10%), angiographic evidence of perforation was noted and there was histological evidence for arterial wall damage. CONCLUSION: Our data show that the new 0.014'' CiTop guidewire can be well operated within normal peripheral and coronary arteries of swine, and with minimal complications within totally occluded blood vessels from human amputations while effectively penetrating and crossing total arterial occlusions.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Angioplastia de Balón/instrumentación , Arteriopatías Oclusivas/terapia , Vasos Coronarios , Extremidad Inferior/irrigación sanguínea , Amputación Quirúrgica , Angioplastia de Balón/efectos adversos , Angioplastia Coronaria con Balón/efectos adversos , Animales , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/patología , Enfermedad Crónica , Constricción Patológica , Angiografía Coronaria , Vasos Coronarios/patología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Ensayo de Materiales , Docilidad , Sus scrofa
10.
J Vasc Interv Radiol ; 20(1): 66-70, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19028115

RESUMEN

PURPOSE: To assess the primary and secondary patency rates for juxtaanastomotic stenoses, with or without superimposed thromboses, of arteriovenous hemodialysis fistulas treated with angioplasty and to compare it with National Kidney Foundation Dialysis Outcomes Quality Initiative treatment guidelines for stenosed and occluded arteriovenous fistulas (50% primary patency rate at 12 months). MATERIALS AND METHODS: This study was a retrospective analysis, covering a period of 5(1/2) years. Forty-three hemodialysis patients were referred due to secondary fistula dysfunction, and angiography was diagnostic of a juxtaanastomotic lesion. Interventions consisted of standard angioplasty techniques along with thrombolysis and/or thrombectomy and intravascular stent placement as needed. Follow-up was performed at the attending dialysis center, and repeat angiography was performed as clinically required. RESULTS: Immediate postprocedural angiography demonstrated an angiographic success rate of 98%. Clinical success, with at least one session of normal dialysis, occurred in 95% of interventions. Primary patency rates at 12 months for the stenosed and stenosed/thrombosed fistulas were 56% and 64%, respectively. Secondary patency rates at 12 months were 64% and 63%, respectively. Half of the stenosed fistulas were patent at 1.5 years, 28% were patent at 4 years, and 13% remained patent at 6 years. No major complications were documented. Four minor complications, which did not require therapy, were noted. CONCLUSIONS: The results achieved are comparable to those reported for interventions at nonjuxtaanastomotic sites and exceed those quoted by the National Kidney Foundation Dialysis Outcomes Quality Initiative guidelines. Angioplastic interventions in a juxtaanastomatic area of arteriovenous fistulas are safe, promote prolonged patency, and postpone the need for surgical intervention or creation of a new fistula.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica/efectos adversos , Diálisis Renal , Trombosis/terapia , Extremidad Superior/irrigación sanguínea , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/instrumentación , Constricción Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Radiografía , Estudios Retrospectivos , Stents , Trombectomía , Terapia Trombolítica , Trombosis/diagnóstico por imagen , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
11.
J Vasc Interv Radiol ; 20(2): 259-63, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19097808

RESUMEN

Hyperammonemia with or without ascites with normal synthetic liver functions after liver transplantation might indicate the presence of anastomotic stenosis of the portal or hepatic vein or the existence of a patent portosystemic shunt. The authors describe six patients, three children after split-liver transplantation and three adults after cadaver liver transplantation, who presented with hyperammonemia. Three patients had ascites. All lesions were successfully treated percutaneously; stents were placed in patients with anastomotic stenoses and coil embolization was performed in patients with patent portosystemic shunts--with either transhepatic or transjugular approaches according to the site of the abnormality. Ammonia levels returned to normal, and ascites had regressed completely for at least 3 months.


Asunto(s)
Ascitis/etiología , Ascitis/cirugía , Hiperamonemia/etiología , Hiperamonemia/cirugía , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/diagnóstico por imagen , Radiografía Intervencional/métodos , Stents , Adolescente , Adulto , Ascitis/diagnóstico por imagen , Prótesis Vascular , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
12.
J Clin Ultrasound ; 37(7): 375-9, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19479717

RESUMEN

PURPOSE: To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. METHODS: Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. RESULTS: The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. CONCLUSION: In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique.


Asunto(s)
Neoplasias Colorrectales/cirugía , Cirugía Colorrectal/métodos , Pólipos Intestinales/cirugía , Ultrasonografía Intervencional/métodos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/cirugía , Anciano , Ciego/diagnóstico por imagen , Ciego/patología , Ciego/cirugía , Colonoscopía , Neoplasias Colorrectales/diagnóstico por imagen , Diagnóstico Precoz , Femenino , Humanos , Pólipos Intestinales/diagnóstico por imagen , Periodo Intraoperatorio , Masculino , Estudios Prospectivos , Ultrasonografía Doppler
13.
Isr Med Assoc J ; 11(10): 611-4, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20077948

RESUMEN

BACKGROUND: Critical limb ischemia is an increasingly common condition that has high surgical morbidity and limited non-surgical options. OBJECTIVES: To evaluate the use of silicon carbide-coated Motion stents, as compared to reported data for bare metal stents, in elderly patients with infrapopliteal artery stenoses causing critical limb ischemia after failed or complicated percutaneous transluminal angioplasty. METHODS: Between January 2003 and March 2004, 41 stents were inserted into 17 consecutive patients (11 males, 6 females, mean age 82 years, range 75-93) following unsuccessful or complicated PTA. Seven patients had one-vessel run-off, six had two-vessel and four had three vessel run-off. All patients suffered from CLI, had up to three lesions and more than one co-morbid condition, and were considered at high surgical risk. Silicon carbide-coated Motion coronary stents, 2.5-4 mm diameterand 25 and 30 mm length, were used. Pre-intervention assessment included clinical condition, ankle brachial index, Doppler ultrasound and digital subtracted angiography. Postintervention evaluation included clinical condition, ABI and Doppler ultrasound at 3, 6 and 12 months. RESULTS: The technical success rate per lesion was 100% (41/41). Two patients died of unrelated causes after 2 and 8 months respectively. Primary patency rates with duplex ultrasound were 68.7% (11/16) at 3 months, 43.7% (7/16) at 6 months and 40% (6/15) after 12 months. Nine patients developed complete occlusion in 13 stents; three of these patients underwent a below-knee amputation and two patients a partial foot amputation. Re-intervention (PTA only) was performed in 7 patients (43.7%). Secondary patency rate was 81.2% (13/16) at 6 months and 60% (9/15) at one year. Mean ABI index had improved at 6 months from 0.32 to 0.67, and to 0.53 at one year. Clinical improvement was evident in 87.5% (14/16) at 6 months and in 66.6% (10/15) at one year. CONCLUSIONS: Silicon carbide-coated stents are comparable to bare metal stents after 6 and 12 months in infrapopliteal interventions in CLI when stenting is indicated.


Asunto(s)
Arteriopatías Oclusivas/terapia , Isquemia/terapia , Pierna/irrigación sanguínea , Enfermedades Vasculares Periféricas/terapia , Arteria Poplítea , Stents , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Angioplastia de Balón , Índice Tobillo Braquial , Arteriopatías Oclusivas/diagnóstico , Compuestos Inorgánicos de Carbono , Materiales Biocompatibles Revestidos , Femenino , Estudios de Seguimiento , Humanos , Isquemia/diagnóstico , Masculino , Enfermedades Vasculares Periféricas/diagnóstico , Compuestos de Silicona , Insuficiencia del Tratamiento , Resultado del Tratamiento , Ultrasonografía Doppler , Grado de Desobstrucción Vascular
14.
Nephrol Dial Transplant ; 23(12): 4036-40, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18586765

RESUMEN

BACKGROUND: Failed renal allografts left in situ may cause inflammation presenting as graft intolerance syndrome (GIS). There are no sufficient data regarding clinical course and treatment options of GIS in paediatric patients. METHODS: A retrospective study of all children with failed renal allografts treated in Schneider's Children Medical Center of Israel during a 10-year period was conducted. Diagnosis of GIS was based on clinical criteria and persistence of renal perfusion according to radio-isotopic scan. RESULTS: Twenty children with failed renal allografts were studied. The mean age at transplantation was 10.3 +/- 4.9 years. The mean graft survival was 2.9 +/- 2.5 years. Two grafts were removed immediately due to vascular complications. Of the 18 patients with transplants remaining in situ, 11 (61%) developed GIS within 2.7 +/- 2.1 months after restarting dialysis. GIS manifestations included fever (91%), local tenderness (82%), hypertension (73%), abdominal pain (64%), macroscopic haematuria (27%), pulmonary congestion (27%) and enlargement of the graft (18%). Laboratory findings included anaemia, hypoalbuminaemia and elevated ESR and CRP. Three patients were successfully treated with indomethacin and/or prednisone. In one patient the graft was surgically removed due to suspected post-transplantation lymphoproliferative disorder. Seven patients underwent percutaneous embolization of the graft, and in six patients a complete resolution of symptoms occurred within 32.2 +/- 45 days. Complications included abscess and retinal artery thrombosis. Six patients were successfully re-transplanted, three are still on haemodialysis and two died of causes unrelated to GIS. CONCLUSIONS: GIS may be common among children with failed renal allografts. Percutaneous embolization of the graft seems effective and safe. Further studies are needed to evaluate late outcome of paediatric patients with GIS.


Asunto(s)
Rechazo de Injerto/etiología , Trasplante de Riñón/efectos adversos , Adolescente , Antiinflamatorios/uso terapéutico , Niño , Preescolar , Embolización Terapéutica , Femenino , Rechazo de Injerto/diagnóstico , Rechazo de Injerto/terapia , Supervivencia de Injerto , Humanos , Masculino , Diálisis Renal , Estudios Retrospectivos , Síndrome , Resultado del Tratamiento
15.
Diagn Interv Radiol ; 13(1): 39-41, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17354194

RESUMEN

PURPOSE: To report the long-term follow-up results of peripheral cutting balloon incision and dilatation (PCBID) after failed high-pressure balloon dilatation in patients with benign ureteral and biliary strictures. MATERIALS AND METHODS: The study included 9 patients (5 males and 4 females) who underwent successful PCBID procedures. Of these, 4 patients had biliary strictures; 2 of them had choledocho-choledochal anastomosis after liver transplantation, one at the choledocho-jejunal anastomosis, and the other at the papilla of Vater after failed endoscopic papillotomy. Of the 5 patients with ureteral strictures, 2 occurred following kidney transplantation, one after local radiation, and 2 had pelvic metastases compressing the urinary tract. The duration of follow-up, both clinical and radiological, was 24 months. RESULTS: The 9 patients who underwent successful PCBID procedures represented 82% of the original group treated by PCBID, which we reported in a previous publication. There were no periprocedural complications. The rate of primary patency, which was confirmed clinically and ultrasonographically at the end of follow- up, was 55% (5/9), and the secondary patency rate was 78% (7/9). Choledocho-choledochal restenosis occurred in 2 patients, 5 and 9 months after liver transplantation, who were treated percutaneously; one by balloon angioplasty (secondary patency for 19 months) and the other by PCBID (patency for 15 months). The remaining 2 patients (both with pelvic metastases) had restenosis 5 and 6 months postprocedure and were successfully treated by the insertion of double-J ureteral stents. CONCLUSION: PCBID is a simple and safe option for the treatment of ureteral and biliary strictures after failed high-pressure balloon dilatation, which demonstrated a two-year primary patency rate of 55% and a secondary patency rate of 78%.


Asunto(s)
Enfermedades de las Vías Biliares/terapia , Cateterismo/métodos , Obstrucción Ureteral/terapia , Adulto , Anciano , Anciano de 80 o más Años , Anastomosis Quirúrgica/efectos adversos , Enfermedades de las Vías Biliares/etiología , Enfermedades de las Vías Biliares/patología , Cateterismo/instrumentación , Constricción Patológica/etiología , Constricción Patológica/patología , Constricción Patológica/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Esfinterotomía Endoscópica/efectos adversos , Resultado del Tratamiento , Obstrucción Ureteral/etiología , Obstrucción Ureteral/patología
16.
Fertil Steril ; 83(2): 487-90, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15705401

RESUMEN

Eight female adult ex-breeder New Zealand white rabbits underwent bilateral, unilateral, or superselective unilateral uterine artery embolization. The histopathologic changes after embolization in New Zealand white rabbits resemble those in humans, making rabbits an appropriate model for experimental uterine artery embolization.


Asunto(s)
Embolización Terapéutica/métodos , Leiomioma/terapia , Neoplasias Uterinas/terapia , Útero/irrigación sanguínea , Animales , Modelos Animales de Enfermedad , Femenino , Fertilidad , Leiomioma/irrigación sanguínea , Proyectos Piloto , Conejos , Neoplasias Uterinas/irrigación sanguínea , Útero/patología
17.
Clin Chim Acta ; 353(1-2): 147-55, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15698602

RESUMEN

BACKGROUND: B-type natriuretic peptide (BNP) is a cardiac hormone that regulates hemodynamic equilibrium and alleviates ventricular stress. In patients with chronic heart failure, BNP levels increase in proportion to the severity of clinical symptoms and degree of decreased left ventricular ejection fraction. BNP has clinical utility in the evaluation, management, and prognosis of patients with heart failure. METHODS: We evaluated the analytical performance characteristics of the BNP immunochemiluminometric assay in the ACS:180 instrument at three hospital laboratory sites. The analytical performance characteristics evaluated included imprecision, sensitivity (minimum detectable concentration, MDC), analytical measurement range (AMR), dilution linearity/recovery, lot-to-lot reagent variation, high-dose hook effect, and comparison against ADVIA Centaur BNP results on patients' EDTA-plasma samples. RESULTS: Total imprecision was <10% coefficient of variation at BNP concentrations of 43-1830 pg/ml; MDC was 6.9 pg/ml; AMR was 6.9-5000 pg/ml; overall recovery of BNP in samples diluted up to 1:10 was 98%; there was no lot-to-lot reagent variation in BNP results and no high-dose hook effect at BNP concentrations up to 100,000 pg/ml; and, ACS:180 results were highly correlated (r=0.996) with Centaur BNP results. CONCLUSIONS: The ACS:180 BNP assay demonstrated excellent analytical performance characteristics and agreement with BNP results obtained using the Centaur instrument.


Asunto(s)
Inmunoensayo/métodos , Péptido Natriurético Encefálico/sangre , Gasto Cardíaco Bajo/sangre , Humanos , Laboratorios de Hospital , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Eur J Radiol ; 53(2): 287-92, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15664294

RESUMEN

OBJECTIVE: Elderly patients with extensive infrainguinal peripheral vascular disease and critical chronic limb ischemia (CCLI) are poor surgical candidates. Our purpose was to evaluate angiographic and clinical results of popliteal, infrapopliteal, and multi-level disease percutaneous transluminal angioplasty (PTA) in such patients. DESIGN: Retrospective study of angiographic and clinical files in selected group. MATERIALS AND METHODS: Between 1996 and 2002, 38 elderly patients aged 80-94 years old (mean age 83.3) with critical leg ischemia were treated with PTA. All patients were at high surgical risk. 31/38 (81.5%) patients had chronic non-healing wounds, and 14/38 (37%) had multi-level disease of superficial femoral, popliteal and crural arteries. One hundred and two lesions were treated by angioplasty. Immediate angiographic and 1 year clinical results were retrospectively analyzed. RESULTS: The overall procedural success rate was 32/38 (84.2%). There were three major complications (7.9%), but no deaths, and three technical failures, all were of infrapopliteal lesions. After 1 year, 27 patients could be followed, five patients died during the first year of unrelated causes. Twenty-three patients (85.2%), were clinically re-occluded within 1 year, but complete and partial wound healing was achieved in 80% (16/20) and rest pain improvement in 57% (4/7), so that overall limb salvage was 74% (20/27). CONCLUSIONS: Elderly patients with multi-level CCLI have a short patency term following angioplasty of 14.8% after 1 year. Nevertheless, this temporary vascular patency enables wound healing or improvement in 74% of these patients, thus such endovascular interventions are recommended in this age group.


Asunto(s)
Isquemia/terapia , Pierna/irrigación sanguínea , Enfermedades Vasculares Periféricas/terapia , Anciano , Anciano de 80 o más Años , Angiografía , Angioplastia de Balón , Enfermedad Crónica , Femenino , Humanos , Isquemia/diagnóstico por imagen , Masculino , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Arteria Poplítea , Estudios Retrospectivos
19.
Asian Cardiovasc Thorac Ann ; 23(1): 55-60, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25053662

RESUMEN

AIM: Bronchial artery angiography with embolization has become a mainstay in the treatment of massive hemoptysis. Whereas the immediate success rate is high, the reported long-term success rate varies widely among different groups. We aimed to explore the long-term outcome and clinical predictors associated with recurrent bleeding following bronchial artery embolization. METHODS: We reviewed the clinical characteristics, underlying etiologies, procedure details, and outcome of bronchial artery embolization performed for massive hemoptysis between 1999 and 2012. RESULTS: All 52 consecutive patients treated by bronchial artery embolization during the study period were included. The major etiologies of massive hemoptysis were bronchiectasis (mostly post-infectious) in 53.8%, and primary and metastatic lung cancer in 30.8%. The immediate success rate was high (48/52; 92%). Of 45 patients who survived more than 24 hours following bronchial artery embolization, recurrent bleeding did not occur in 19 (42.2%) during a median follow-up period of 60 months (range 6-130 months). Bleeding recurred in 26 (57.7%); within 30 days in 15 (33.3%) and after 1 month in the other 11 (24.4%). The average time to onset of early and late repeat bleeding was 2 and 506 days, respectively. Idiopathic bronchiectasis and lung cancer were associated with a high likelihood of late bleeding recurrence. CONCLUSIONS: Bronchial artery embolization is an effective immediate treatment for massive hemoptysis. Because the bleeding recurrence rate is high in patients with lung cancer or idiopathic bronchiectasis, surgery should be considered in these patients following initial stabilization by bronchial artery embolization. For other underlying etiologies, the long-term outcome is excellent.


Asunto(s)
Arterias Bronquiales , Embolización Terapéutica/métodos , Hemoptisis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Arterias Bronquiales/diagnóstico por imagen , Bronquiectasia/complicaciones , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Femenino , Hemoptisis/diagnóstico , Hemoptisis/etiología , Hemoptisis/mortalidad , Humanos , Israel , Estimación de Kaplan-Meier , Neoplasias Pulmonares/complicaciones , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
20.
Fertil Steril ; 81(2): 424-9, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14967384

RESUMEN

OBJECTIVE: To evaluate the prevalence of varicocele in the left and right spermatic veins in infertile men by several methods of examination. DESIGN: Prospective study. SETTING: Andrology unit of a department of obstetrics and gynecology, and interventional radiology unit of the radiology department at a tertiary care facility. PATIENT(S): Two hundred eighty-six infertile men evaluated for varicocele. INTERVENTION(S): Patients underwent evaluation for infertility. Physical examination was followed by contact thermography, Doppler sonography, and venography of both testes. MAIN OUTCOME MEASURE(S): We measured the prevalence of varicocele in the left and right spermatic veins in infertile men, and the response of semen parameters after embolization of internal spermatic vein. RESULT(S): Varicocele was detected by one of the noninvasive methods and confirmed by venography in 255 patients (89.2%): the left site in 45 (17.6%), the right side in 4 (1.5%), and bilaterally in 206 (80.8%). All patients were treated by embolization. Mean sperm concentration increased from 6.12 +/- 1.02 to 21.3 +/- 1.69 million/mL; mean sperm motility from 16.81 +/- 1.51 to 35.90 +/- 1.41%; and mean sperm morphology from 9.75 +/- 0.85 to 16.92 +/- 1.17%. Pregnancy rate was 43.5%. CONCLUSION(S): The present study finds that what was traditionally considered a predominantly unilateral anatomical abnormality apparently has a strikingly high bilateral prevalence (80.7%). This may suggest that we should consider varicocele a bilateral disease. The second finding is the high rate of varicocele detected by venography, thermography, and sonography when compared with physical examination results. Our study may have important implications for treatment, indicating that patients with clinical evidence of unilateral left varicocele should be carefully evaluated for bilateral varicocele.


Asunto(s)
Varicocele/fisiopatología , Lateralidad Funcional , Humanos , Incidencia , Masculino , Estudios Prospectivos , Escleroterapia , Escroto , Recuento de Espermatozoides , Motilidad Espermática , Termografía , Varicocele/diagnóstico , Varicocele/epidemiología , Varicocele/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA