Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(5): 1177-1182, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36942777

RESUMEN

INTRODUCTION: Routine ultrasound (US) guidance for femoral venous access to decrease vascular complications of atrial fibrillation (AF) ablation procedures has been advocated. However, the benefit has not been unequivocally demonstrated by randomized-trial data. METHODS: Consecutive patients undergoing pulmonary vein isolation (PVI) on uninterrupted anticoagulant treatment were included. A quasi-random allocation to either US-guided or conventional puncture group was based on which of the two procedure rooms the patient was scheduled in, with only one of the rooms equipped with a US machine including a vascular transducer. The same four novice operators in rotation, with no relevant previous experience in US-guided vascular access performed venous punctures in both rooms. Major and minor vascular complications and the rate of prolonged hospitalization were compared. Major vascular complication was defined as groin hematoma, arteriovenous fistula, or pseudoaneurysm. Hematoma was considered as a major vascular complication if it met type 2 or higher Bleeding Academic Research Consortium criteria (requiring nonsurgical, medical intervention by a health care professional; leading to hospitalization or increased level of care, or prompting evacuation). RESULTS: Of the 457 patients 199 were allocated to the US-guided puncture group, while the conventional, palpation-based approach was performed in 258 cases. Compared with the conventional technique, US guidance reduced the rate of any vascular complication (11.63% vs. 2.01%, p < .0001), including both major (4.26% vs. 1.01%, p = .038) and minor (7.36% vs. 1.01%, p = .001) vascular complications. In addition, the rate of prolonged hospitalization was lower in the US-guided puncture group (5.04% vs. 1.01%, p = .032). CONCLUSION: The use of US for femoral vein puncture in patients undergoing PVI decreased the rate of both major and minor vascular complications. This quasi-randomized comparison strongly supports adapting routine use of US for AF ablation procedures.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ultrasonografía Intervencional/métodos , Hemorragia/etiología , Hemorragia/prevención & control , Hematoma , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 33(6): 1190-1196, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35362181

RESUMEN

BACKGROUND: The two most common postoperative atrial flutter (AFL) circuits after right atriotomy are the cavotricuspid isthmus (CTI) dependent and the lateral, peri-incisional. We investigated whether radiofrequency ablation (RFA) of both circuits results in more favorable long-term outcomes. METHODS: Single-center retrospective cohort study of consecutive patients who underwent RFA of AFL after open-heart surgery. The effect of surgery type and RFA strategy on AFL recurrence was evaluated. RESULTS: One hundred and forty-two patients (mean age 64.5 ± 12.7 years, 65.% male) were enrolled. Patients with right atrial (RA) flutter (n = 124) were divided into two groups based on the index RFA procedure: only one RA circuit was ablated (Group 1, n = 84, 67.7%) or both the CTI and the peri-incisional circuit ablated (Group 2, n = 40, 32.3%). The previous open-heart surgery was categorized based on the extension of the RA incision: limited (Type A) or extended (Type B) atriotomy. After a mean follow-up of 36 ± 28 months, flutter recurrence was not different among patients with limited RA atriotomy (25% vs. 22% in Groups 1A and 2A, respectively, p = 1.0). However, after type B surgery, ablation of both AFL circuits was associated with a reduced recurrence rate (63% vs. 26% in Groups 1B and 2B, respectively, p = .002). CONCLUSIONS: In patients with postoperative RA flutter after extended right atriotomy, ablation of both the CTI and the peri-incisional isthmus significantly reduces the AFL recurrence rate. Prophylactic ablation of both isthmi, even if not proven to support reentry, is reasonable in this population.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Anciano , Arritmias Cardíacas/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/prevención & control , Ablación por Catéter/efectos adversos , Femenino , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
J Cardiovasc Electrophysiol ; 30(2): 171-177, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30375070

RESUMEN

INTRODUCTION: Both isoproterenol (Iso) and adenosine (Ado) are used to induce atrial fibrillation (AF) in the electrophysiology lab. However, the utility of Ado has not been systematically established. OBJECTIVE: The purpose of this study was to compare Ado to Iso for the induction of paroxysmal AF. METHODS: Forty patients (16 women; mean age, 60 ± 12 years) with paroxysmal AF, presenting for ablation were prospectively included of whom 36 (90%) received Ado (18-36 mg) and/or Iso (3-20 µg/min incremental dose) in a randomized order (26 [72%] received both drugs). RESULTS: AF was induced with Iso in 15 of 32 (47%) and with Ado in 12 of 30 (40%) patients (P = 0.9). Iso-triggered AF started from the left pulmonary veins (PVs) in 11 of 15 (73%), from the right PVs in 3 of 15 (20%), and from the coronary sinus (CS) in 1 of 15 (7%) cases. Ado-induced AF episodes originated from the left PVs in 6 of 12 (50%), from the right atrium (RA) in 4 of 12 (33%), and from the CS in 2 of 12 (17%) cases. Altogether, Iso-induced AF was more likely initiated from the PVs (93%) compared with Ado (50%) ( P = 0.02). Ado-induced non-PV triggers were not predictive of arrhythmia recurrence after PV isolation. CONCLUSION: Ado much more frequently induces non-PV triggers, especially from the RA. The clinical significance of these foci, however, is questionable.


Asunto(s)
Adenosina/administración & dosificación , Agonistas Adrenérgicos beta/administración & dosificación , Fibrilación Atrial/diagnóstico , Seno Coronario/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Isoproterenol/administración & dosificación , Venas Pulmonares/fisiopatología , Agonistas del Receptor Purinérgico P1/administración & dosificación , Potenciales de Acción , Adenosina/efectos adversos , Agonistas Adrenérgicos beta/efectos adversos , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Seno Coronario/cirugía , Femenino , Frecuencia Cardíaca , Humanos , Isoproterenol/efectos adversos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/cirugía , Agonistas del Receptor Purinérgico P1/efectos adversos , Reproducibilidad de los Resultados
4.
Orv Hetil ; 158(10): 387-392, 2017 Mar.
Artículo en Húngaro | MEDLINE | ID: mdl-28270004

RESUMEN

At present, the direct thrombin inhibitor dabigatran is the only one amongst the new direct anticoagulants which has an effective, specific reversal agent. The novel agent idarucizumab is a humanized, monoclonal antibody fragment binds to dabigatran within minutes thereby offers an opportunity to induce a safe, long-lasting reverse of the anticoagulant effects of dabigatran. The authors describe the first use of idarucizumab in Hungary (23. 05. 2016) in an old female patient with non-valvular paroxysmal atrial fibrillation of high stroke risk-score and renal dysfunction who was taking dabigatran (2 x 110 mg/day) when an acute abdomen developed requiring emergency cholecystectomy. Patient received the antidote (idarucizumab 2 x 2.5 g/50 ml iv.) two hours before the surgical intervention, and she did not have any uncontrollable, life-threatening bleeding during the surgery. The high activated partial thromboplastin time relating to anticoagulative influence before the surgery normalized completely after administration of the antidote. Antagonizing dabigatran with idarucizumab was feasible and safe without any side effects. The patient received dabigatran therapy again after her recovery. Orv. Hetil., 2017, 158(10), 387-392.


Asunto(s)
Anticuerpos Monoclonales Humanizados/uso terapéutico , Antitrombinas/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Dabigatrán/efectos adversos , Anciano de 80 o más Años , Femenino , Humanos , Hungría , Resultado del Tratamiento
5.
Acta Chim Slov ; 61(2): 376-81, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25125121

RESUMEN

In this study an easy strategy for conducting polymer based nanocomposite formation is presented through the deposition of cobalt-ferrite (CoFe(2)O(4)) containing poly(3,4-ethylenedioxythiophene) (PEDOT) thin layers. The electrochemical polymerization has been performed galvanostatically in an aqueous micellar medium in the presence of the nanoparticles and the surface active Triton X-100. The nanoparticles have been characterized by Transmission electron microscopy (TEM), the thin layers has been studied by applying Scanning electron microscopy (SEM), and X-ray diffraction (XRD), and the basic electrochemical properties have been also determined. Moreover, electrocatalytic activity of the composite was demonstrated in the electrooxidation reaction of dopamine (DA). The enhanced sensitivity - related to the cobalt-ferrite content - and the experienced photocatalyitic activity are promising for future application.

6.
Orv Hetil ; 155(25): 986-92, 2014 Jun 22.
Artículo en Húngaro | MEDLINE | ID: mdl-24936574

RESUMEN

INTRODUCTION: During chemotherapy of cancer patients, vein inflammation may develop which may lead to pain and difficulty in blood sampling. The use of implanted venous access ports may overcome these problems. With a correct use of needles, venous port membrane may be pierced 2000-2500 times. AIM: The aim of the authors was to analyze their experience with venous access ports and evaluate whether insertion of venous ports occurred in an optimal time. METHOD: A retrospective study of 63 patients who received venous access ports between 2005 and 2012 was carried out. Complication rate and the time of venous port insertion were analysed. RESULTS: Of the 63 patients, the venous access port was removed in 22 patients because it was no longer required (n = 14) due to the development of complications (n = 8). 24 patients died from the underlying disease and 17 patients are still alive with the venous port in place. CONCLUSIONS: In the period studied patients with venous access ports had an improved quality of life. However, the authors conclude that venous access ports were not inserted in an optimal time.


Asunto(s)
Antineoplásicos/administración & dosificación , Cateterismo Venoso Central , Catéteres de Permanencia , Neoplasias/tratamiento farmacológico , Adulto , Anciano , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/estadística & datos numéricos , Catéteres de Permanencia/efectos adversos , Catéteres de Permanencia/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Factores de Tiempo
7.
EES Catal ; 2(2): 664-674, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38464594

RESUMEN

Photoelectrodes with FTO/Au/Sb2Se3/TiO2/Au architecture were studied in photoelectrochemical CO2 reduction reaction (PEC CO2RR). The preparation is based on a simple spin coating technique, where nanorod-like structures were obtained for Sb2Se3, as confirmed by SEM images. A thin conformal layer of TiO2 was coated on the Sb2Se3 nanorods via ALD, which acted as both an electron transfer layer and a protective coating. Au nanoparticles were deposited as co-catalysts via photo-assisted electrodeposition at different applied potentials to control their growth and morphology. The use of such architectures has not been explored in CO2RR yet. The photoelectrochemical performance for CO2RR was investigated with different Au catalyst loadings. A photocurrent density of ∼7.5 mA cm-2 at -0.57 V vs. RHE for syngas generation was achieved, with an average Faradaic efficiency of 25 ± 6% for CO and 63 ± 12% for H2. The presented results point toward the use of Sb2Se3-based photoelectrodes in solar CO2 conversion applications.

8.
Materials (Basel) ; 16(17)2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37687613

RESUMEN

The persulfate-based advanced oxidation process is a promising method for degrading organic pollutants. Herein, TiO2 and ZnO photocatalysts were combined with the peroxydisulfate ion (PDS) to enhance the efficiency. ZnO was significantly more efficient in PDS conversion and SO4•- generation than TiO2. For ZnO, the PDS increased the transformation rate of the trimethoprim antibiotic from 1.58 × 10-7 M s-1 to 6.83 × 10-7 M s-1. However, in the case of TiO2, the moderated positive effect was manifested mainly in O2-free suspensions. The impact of dissolved O2 and trimethoprim on PDS transformation was also studied. The results reflected that the interaction of O2, PDS, and TRIM with the surface of the photocatalyst and their competition for photogenerated charges must be considered. The effect of radical scavengers confirmed that in addition to SO4•-, •OH plays an essential role even in O2-free suspensions, and the contribution of SO4•- to the transformation is much more significant for ZnO than for TiO2. The negative impact of biologically treated domestic wastewater as a matrix was manifested, most probably because of the radical scavenging capacity of Cl- and HCO3-. Nevertheless, in the case of ZnO, the positive effect of PDS successfully overcompensates that, due to the efficient SO4•- generation. Reusability tests were performed in Milli-Q water and biologically treated domestic wastewater, and only a slight decrease in the reactivity of ZnO photocatalysts was observed.

9.
J Cardiovasc Electrophysiol ; 23(9): 996-1000, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22812499

RESUMEN

UNLABELLED: Randomized Trial of ICE During CTI Ablation. INTRODUCTION: Despite a high success rate, radio-frequency ablation (RFA) of the cavotricuspid isthmus (CTI) can be unusually challenging in some cases. We postulated that visualization of the CTI with intracardiac echocardiography (ICE) could maximize the success rate, decrease the procedure and ablation time, and minimize the radiation exposure. METHODS AND RESULTS: In our prospective, randomized study, we included 102 patients scheduled for CTI ablation. We randomized patients in 2 groups: guided only by fluoroscopy (n = 52) or ICE-guided (n =50) group. Procedure time, fluoroscopy time, and the time spent for RFA were significantly shorter, radiation exposure (dose-area product-DAP) and the sum of delivered radio frequency energy were significantly lower in the ICE-group (68.06 ± 15.09 minutes vs 105.94 ± 36.51 minutes, P < 0.001, 5.54 ± 3.77 minutes vs 18.63 ± 10.60 minutes, P <0.001, 482.80 ± 534.12 seconds vs 779.76 ± 620.82 seconds, P = 0.001 and 397.62 ± 380.81 cGycm(2) vs 1,312.92 ± 1,129.28 cGycm(2) , P < 0.001, 10,866.84 ± 6,930.84 Ws vs 16,393.56 ± 13,995.78 Ws, P = 0.048, respectively). Seven patients (13%) from the fluoroscopy-only group crossed over to ICE-guidance because of prolonged unsuccessful RFA and were all treated successfully. Four vascular complications and 2 recurrences were equally distributed between the 2 groups. CONCLUSIONS: ICE-guided ablation of the CTI significantly shortens the procedure and fluoroscopy time, markedly decreases radiation exposure, and time spent for ablation in comparison with fluoroscopy-only procedures. At the same time, visualization with ICE allowed successful ablation in challenging cases. (J Cardiovasc Electrophysiol, Vol. 23, pp. 996-1000, September 2012).


Asunto(s)
Ablación por Catéter/métodos , Electrocardiografía , Válvula Tricúspide/cirugía , Vena Cava Inferior/cirugía , Anciano , Ablación por Catéter/efectos adversos , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia
11.
Herzschrittmacherther Elektrophysiol ; 33(1): 81-83, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34989832

RESUMEN

A persistent left superior vena cava (LSVC) represents a challenging congenital abnormality for transvenous cardiac device implantation. In the current case a secondary prophylactic VDD implantable cardioverter-defibrillator (ICD) implantation was planned in a 75-year-old woman presenting with ischemic cardiomyopathy and elevated stroke risk. Since no venous communication to the right side was identified intraoperatively, the lead was placed via the persistent LSVC. The far-field signal on the floating atrial dipole could be successfully blanked out, and appropriate device function with high and stable atrial sensing was demonstrated at follow-up.


Asunto(s)
Desfibriladores Implantables , Isquemia Miocárdica , Vena Cava Superior Izquierda Persistente , Anciano , Estimulación Cardíaca Artificial , Femenino , Humanos , Vena Cava Superior/anomalías , Vena Cava Superior/diagnóstico por imagen
12.
J Interv Card Electrophysiol ; 63(3): 709-714, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35044581

RESUMEN

PURPOSE: Radiofrequency (RF) catheter ablation of the slow pathway (SP) in atrioventricular nodal reentry tachycardia (AVNRT) is highly effective; however, it may require prolonged fluoroscopy and RF time. We postulated that visualization of the SP region with intracardiac echocardiography (ICE) could decrease ablation time, minimize radiation exposure, and facilitate SP ablation compared to the standard, fluoroscopy-guided approach. METHODS: In our study, we randomized 91 patients undergoing electrophysiologic study and SP ablation for AVNRT into 2 groups: fluoroscopy-only (n = 48) or ICE-guided (n = 43) group. Crossover to ICE-guidance was allowed after 8 unsuccessful RF applications. RESULTS: Mapping plus ablation time (mean ± standard deviation: 18.8 ± 16.1 min vs 11.6 ± 15.0 min, p = 0.031), fluoroscopy time (median [interquartile range]: 4.9 [2.93-8.13] min vs. 1.8 [1.2-2.8] min, p < 0.001), and total ablation time (144 [104-196] s vs. 81 [60-159] s, p = 0.001) were significantly shorter in the ICE group. ICE-guidance was associated with reduced radiation exposure (13.2 [8.2-13.4] mGy vs. 3.7 [1.5-5.8] mGy, p < 0.001). The sum of delivered RF energy (3866 [2786-5656] Ws vs. 2283 [1694-4284] Ws, p = 0.002) and number of RF applications (8 [4.25-12.75] vs. 4 [2-7], p = 0.001) were also lower with ICE-guidance. Twelve (25%) patients crossed over to the ICE-guided group. All were treated successfully thereafter with similar number, time, and cumulative energy of RF applications compared to the ICE group. No recurrence occurred during the follow-up. CONCLUSIONS: ICE-guidance during SP ablation significantly reduces mapping and ablation time, radiation exposure, and RF delivery in comparison to fluoroscopy-only procedures. Moreover, early switching to ICE-guided ablation seems to be an optimal choice in challenging cases.


Asunto(s)
Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Ablación por Catéter/métodos , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Fluoroscopía/métodos , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico por imagen , Taquicardia por Reentrada en el Nodo Atrioventricular/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
13.
Europace ; 13(7): 1022-7, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21454337

RESUMEN

AIMS: Early activation at the His bundle (HB) region or proximal coronary sinus (CS) during focal atrial tachycardias (FATs) often necessitates biatrial mapping. Analysis of CS electrograms (EGMs) consisting of a near-field (N) component from CS musculature and a far-field (F) component from left atrial (LA) myocardium can uncover LA activation preceding right atrial (RA) activation. A similar pattern might be observed at the HB. METHODS AND RESULTS: Eight patients underwent RA and LA pacing testing the hypothesis that N and F components originating from the RA and LA septum are present in the HB atrial EGM (Pacing group). In this group N preceded F (N-F sequence) in all, while F preceded N (F-N sequence) in seven of eight patients during RA and LA pacing, respectively. Twenty-seven patients with FAT demonstrating earliest activation at the HB or proximal CS during limited RA mapping were also studied (FAT group). Two observers analysed the EGMs at the earliest site during FAT. They found an N-F sequence in 17 (94%) and 16 (89%) of 18 RA FAT and an F-N sequence in seven (78%) and eight (89%) of nine LA FAT, respectively. The F-N sequence predicted the need for LA access with a sensitivity of 78 and 89% and a specificity of 94 and 89%. CONCLUSION: Near-field and F components from RA and LA activation can be identified in the HB atrial EGM. Earliest atrial EGM analysis at the HB or CS can predict the need for LA access during FAT ablation.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Seno Coronario/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Taquicardia Atrial Ectópica/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Taquicardia Atrial Ectópica/cirugía
14.
BMC Nephrol ; 12: 43, 2011 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-21910914

RESUMEN

BACKGROUND: Despite the substantial progress in the quality of critical care, the incidence and mortality of acute kidney injury (AKI) continues to rise during hospital admissions. We conducted a national, multicenter, prospective, epidemiological survey to evaluate the importance of AKI in intensive care units (ICUs) in Hungary. The objectives of this study were to determine the incidence of AKI in ICU patients; to characterize the differences in aetiology, illness severity and clinical practice; and to determine the influencing factors of the development of AKI and the patients' outcomes. METHODS: We analysed the demographic, morbidity, treatment modality and outcome data of patients (n = 459) admitted to ICUs between October 1st, 2009 and November 30th, 2009 using a prospectively filled in electronic survey form in 7 representative ICUs. RESULTS: The major reason for ICU admission was surgical in 64.3% of patients and medical in the remaining 35.7%. One-hundred-twelve patients (24.4%) had AKI. By AKIN criteria 11.5% had Stage 1, 5.4% had Stage 2 and 7.4% had Stage 3. In 44.0% of patients, AKI was associated with septic shock. Vasopressor treatment, SAPS II score, serum creatinine on ICU admission and sepsis were the independent risk factors for development of any stage of AKI. Among the Stage 3 patients (34) 50% received renal replacement therapy. The overall utilization of intermittent renal replacement therapy was high (64.8%). The overall in-hospital mortality rate of AKI was 49% (55/112). The ICU mortality rate was 39.3% (44/112). The independent risk factors for ICU mortality were age, mechanical ventilation, SOFA score and AKI Stage 3. CONCLUSIONS: For the first time we have established the incidence of AKI using the AKIN criteria in Hungarian ICUs. Results of the present study confirm that AKI has a high incidence and is associated with high ICU and in-hospital mortality.


Asunto(s)
Lesión Renal Aguda/epidemiología , Mortalidad Hospitalaria/tendencias , Unidades de Cuidados Intensivos/tendencias , Lesión Renal Aguda/etiología , Lesión Renal Aguda/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hungría/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
15.
Nanomaterials (Basel) ; 12(1)2021 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-35009961

RESUMEN

In this work, the application of high-power LED365nm and commercial, low-price LED398nm for heterogeneous photocatalysis with TiO2 and ZnO photocatalysts are studied and compared, focusing on the effect of light intensity, photon energy, quantum yield, electrical energy consumption, and effect of matrices and inorganic components on radical formation. Coumarin (COU) and its hydroxylated product (7-HC) were used to investigate operating parameters on the •OH formation rate. In addition to COU, two neonicotinoids, imidacloprid and thiacloprid, were also used to study the effect of various LEDs, matrices, and inorganic ions. The transformation of COU was slower for LED398nm than for LED365nm, but r07-HC/r0COU ratio was significantly higher for LED398nm. The COU mineralization rate was the same for both photocatalysts using LED365nm, but a significant difference was observed using LED398nm. The impact of matrices and their main inorganic components Cl- and HCO3- were significantly different for ZnO and TiO2. The negative effect of HCO3- was evident, however, in the case of high-power LED365nm and TiO2, and the formation of CO3•- almost doubled the r07-HC and contributes to the conversion of neonicotinoids by altering the product distribution and mineralization rate.

16.
Materials (Basel) ; 15(1)2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-35009197

RESUMEN

The comparison of the efficiency of the commercially available photocatalysts, TiO2 and ZnO, irradiated with 365 nm and 398 nm light, is presented for the removal of two antibiotics, sulfamethazine (SMT) and sulfamethoxypyridazine (SMP). The •OH formation rate was compared using coumarin, and higher efficiency was proved for TiO2 than ZnO, while for 1,4-benzoquinone in O2-free suspensions, the higher contribution of the photogenerated electrons to the conversion was observed for ZnO than TiO2, especially at 398 nm irradiation. An extremely fast transformation and high quantum yield of SMP in the TiO2/LED398nm process were observed. The transformation was fast in both O2 containing and O2-free suspensions and takes place via desulfonation, while in other cases, mainly hydroxylated products form. The effect of reaction parameters (methanol, dissolved O2 content, HCO3- and Cl-) confirmed that a quite rarely observed energy transfer between the excited state P25 and SMP might be responsible for this unique behavior. In our opinion, these results highlight that "non-conventional" mechanisms could occur even in the case of the well-known TiO2 photocatalyst, and the effect of wavelength is also worth investigating.

17.
Langmuir ; 26(16): 13697-702, 2010 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-20695622

RESUMEN

This study focuses on electrodeposition for infiltrating in situ a conducting polymer such as poly(3,4-ethylenedioxythiophene) (PEDOT) into a host titanium dioxide (TiO(2)) nanotube array (NTA) framework. The TiO(2) NTA was electrosynthesized on titanium foil in turn by anodization in a fluoride-containing medium. The PEDOT layer was electrografted into the TiO(2) NTA framework using a two-step potentiostatic growth protocol in acetonitrile containing supporting electrolyte. The nanoscopic features of oligomer/polymer infiltration and deposition in the NTA interstitial voids were monitored by field-emission scanning electron microscopy. Systematic changes in the nanotube inner diameter and the wall thickness afforded insights into the evolution of the TiO(2)NTA/PEDOT hybrid assembly. This assembly was subsequently characterized by UV-visible diffuse reflectance, cyclic voltammetry, and photoelectrochemical measurements. These data serve as a prelude to further use of these hybrids in heterojunction solar cells.

18.
Analyst ; 135(2): 375-80, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20098773

RESUMEN

In this work a poly(3,4-ethylenedioxythiophene) (PEDOT)/iron oxalate composite was synthesized by electrochemical polymerization. The layer was deposited potentiostatically from the monomer-containing solution in the presence of iron(II) oxalate. Similarly to the polypyrrole/iron oxalate electrode--presented in a recent paper--the layer gave a negative photocurrent, which depended on the oxygen concentration of the electrolyte. This cathodic photocurrent--taken as the differences between the values registered under illumination and in the dark at -750 mV potential on the cathodic part of the voltammetric cycles--confirmed the sensitivity of the PEDOT/iron oxalate electrode for dissolved oxygen. Stationary photocurrents were determined also from chronoamperometric measurements, and they exhibited a linear behaviour with the dissolved oxygen concentration to below 1 ppm. The photo-effect of the PEDOT/iron oxalate layer can be attributed to the excitation of the neutral form of the film.

19.
Europace ; 11(8): 1011-7, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19443430

RESUMEN

AIMS: The purpose of our study was to determine the acute effects of complex fractionated electrograms (CFAE) ablation guided by automated detection on dominant frequency (DF) and regulatory index (RI) for the fibrillatory process. METHODS AND RESULTS: The study included 41 patients (21 paroxysmal and 20 persistent) referred for catheter ablation of atrial fibrillation (AF). Our ablation strategy included pulmonary vein isolation (PVI) as first step, CFAE ablation as second step, roof line ablation as next, and mitral isthmus ablation as last step. On the CFAE map, we were targeting only points outside the previous PVI lines. Simultaneously, we evaluated DF and RI changes in the coronary sinus after each step of ablation. The termination rate by CFAE ablation was low (12.5% in paroxysmal and 10% in persistent AF). Changes in DF and RI after CFAE ablation were not significant (<0.25 Hz and max. 0.02 increase for RI) compared with other ablation steps. Pulmonary vein isolation, roof line, and mitral isthmus ablation resulted in significant changes in DF and RI. CONCLUSION: On the basis of our results, CFAE ablation guided by a dedicated software algorithm and performed after standard PVI without CFAE remapping does not influence the fibrillatory process significantly. Application of a modified algorithm with different settings warrants further investigations.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Potenciales de Acción , Animales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 19(7): 653-8, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18284500

RESUMEN

INTRODUCTION: While some posteroseptal and left posterior accessory pathways (APs) can be ablated on the tricuspid annulus or within the coronary venous system, others require a left-sided approach. "Fragmented" or double potentials are frequently recorded in the coronary sinus (CS), with a smaller, blunt component from left atrial (LA) myocardium, and a larger, sharp signal from the CS musculature. METHODS AND RESULTS: Forty patients with posteroseptal or left posterior AP were included. The LA-CS activation sequence was determined at the earliest site during retrograde AP conduction. Eleven APs (27.5%) were ablated on the tricuspid annulus (right endocardial), 9 (22.5%) inside the coronary venous system (epicardial), and 20 (50%) on the mitral annulus (left endocardial). A "fragmented" or double "atrial" potential was recorded in all patients inside the CS at the earliest site during retrograde AP conduction. Sharp potential from the CS preceded the LA blunt component (sharp/blunt sequence) in all patients with an epicardial AP, and in 10 of 11 (91%) patients with a right endocardial AP. Therefore, 18 of 19 (95%) APs ablated by a right-sided approach produced this pattern. The reverse sequence (blunt/sharp) was recorded in 19 of 20 (95%) patients with a left endocardial AP. CONCLUSION: During retrograde AP conduction, the sequence of LA-CS musculature activation-as deduced from analysis of electrograms recorded at the earliest site inside the CS-can differentiate posteroseptal and left posterior APs that require left heart catheterization from those that can be eliminated by a totally venous approach.


Asunto(s)
Ablación por Catéter/métodos , Seno Coronario , Electrocardiografía/métodos , Atrios Cardíacos , Sistema de Conducción Cardíaco/anomalías , Sistema de Conducción Cardíaco/cirugía , Tabiques Cardíacos/cirugía , Contracción Miocárdica , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA