Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Dermatol Ther ; 34(5): e15068, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34297465

RESUMEN

The management of hidradenitis suppurativa (HS) flares with intralesional steroids lacks strong scientific evidence but limited data suggest that it may be useful. The objective of this study is to assess the clinical and ultrasound responses of HS flares to ultrasound-guided injections of intralesional triamcinolone (40 mg/ml) with a dilution 1:4 versus 1:2 at 30-day (t1), 60-day (t2), and 90-day (t3) follow-up. We recruited patients with ≤3 acute lesions, unresponsive to topical therapy. At baseline we assessed lesions clinically and by ultra-high frequency ultrasound (48 or 70 MHz) and randomly performed an ultrasound-guided injection of triamcinolone. Assessments were repeated at t1, t2, and t3 follow-up, re-injecting the lesion in the case of no or partial response. We treated 49 lesions: 38.8% showed improvements at t1; 46.9% at t2; 6% at t3; and 8.3% showed no clinical and ultrasound improvements. Long-term follow-up data confirmed a statistically significant reduction in Visual Analogue Scale (VAS)-pain, Dermatology Life Quality Index (DLQI), and HS-Physician Global Assessment (HS-PGA), as well as edema and vascular signals. No adverse effects were reported. Our study suggests that ultrasound-injections with a 1:2 dilution are beneficial for HS flares that do not respond to topical treatment and should be included in the therapeutic algorithm.


Asunto(s)
Hidradenitis Supurativa , Hidradenitis Supurativa/diagnóstico por imagen , Hidradenitis Supurativa/tratamiento farmacológico , Humanos , Inyecciones Intralesiones , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Triamcinolona , Ultrasonografía Intervencional
2.
Skin Res Technol ; 27(2): 277-282, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33529441

RESUMEN

BACKGROUND: High-frequency ultrasound (HFUS) is a non-invasive method that detects superficial skin features. Ultra-high frequencies (50-100 MHz) can reveal epidermis and dermis structures. OBJECTIVES: In this study, we describe the psoriatic plaque using a new device equipped with a 70 MHz probe (VEVO® MD, Fujifilm, VisualSonics) and we assess the lesion before and after ixekizumab. METHODS: We examined the superficial hyperechoic band, the subepidermal hypoechoic band (SLEB), and the vascularization of the plaque in ten patients affected by plaque psoriasis. RESULTS: The average superficial hyperechoic band thickness was 0.2157 mm before treatment, 0.1611 mm after 15 days, and 0.1354 mm (P < .05) after 30 days. The SLEB thickness was 0.7535 mm at baseline, 0.3300 mm after 15 days (P < .05), and 0.2007 mm (P < .05) after 30 days. The average percentage vascularization was 50.21% at baseline, 13.15% after 15 days (P < .05), and 5.97% after 30 days. UHFUS assessment highlighted the rapid action of the drug in terms of the decrease in vascularization after 15 days. It revealed a statistically significant reduction in SLEB thickness after 15 days and a significant reduction in the hyperechoic superficial band after 30 days. CONCLUSIONS: VEVO® MD provides physicians with high-resolution details of the psoriatic plaque, thus enabling tailored-made treatments.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Psoriasis , Humanos , Psoriasis/diagnóstico por imagen , Psoriasis/tratamiento farmacológico , Piel/diagnóstico por imagen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA