Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 150(17): 1327-1342, 2024 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-38989565

RESUMEN

BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68-79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6-50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Masculino , Femenino , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/instrumentación , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Anciano de 80 o más Años
2.
Ann Surg ; 279(6): 961-972, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38214159

RESUMEN

OBJECTIVE: To provide an updated systematic review and meta-analysis with meta-regression of efficacy and safety of fenestrated/branched endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) compared with open repair. BACKGROUND: Endovascular repair of TAAAs may be a promising alternative to open surgery by reducing invasiveness and expanding the eligible population, but evidence remains limited. METHODS: We applied "Prepared Items for Systematic Reviews and Meta-analysis" guidelines to retrieve, quantitatively pool, and critically evaluate the efficacy and safety (including 30-day mortality, reintervention, spinal cord injury [SCI], and renal injury) of both approaches. Original studies were retrieved from PubMed, Embase, and Cochrane Library until April 20, 2022, excluding papers reporting <10 patients. Pooled proportions and means were determined using a random-effect model. Heterogeneity between studies was evaluated with I2 statistics. RESULTS: Sixty-four studies met the predefined inclusion criteria. Endovascular cohort patients were older and had higher rates of comorbidities. Endovascular repair was associated with similar proportions of mortality (0.07, 95% confidence intervals [CI]: 0.06-0.08) compared with open repair (0.09, 95% CI: 0.08-0.12; P = 0.22), higher proportions of reintervention (0.19, 95% CI: 0.13-0.26 vs 0.06, 95% CI: 0.04-0.10; P < 0.01), similar proportions of transient SCI (0.07, 95% CI: 0.05-0.09 vs 0.06, 95% CI: 0.05-0.08; P = 0.28), lower proportions of permanent SCI (0.04, 95% CI: 0.03-0.05 vs 0.06, 95% CI: 0.05-0.07; P < 0.01), and renal injury (0.08, 95% CI: 0.06-0.10 vs 0.13, 95% CI: 0.09-0.17; P = 0.02). Results were affected by high heterogeneity and potential publication bias. CONCLUSIONS: Despite these limitations and the lack of randomized trials, this meta-analysis suggests that endovascular TAAA repair could be a safer alternative to the open approach.


Asunto(s)
Aneurisma de la Aorta Torácica , Procedimientos Endovasculares , Humanos , Procedimientos Endovasculares/métodos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Aneurisma de la Aorta Toracoabdominal
3.
J Vasc Surg ; 80(5): 1418-1424.e1, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39029810

RESUMEN

OBJECTIVE: This study aimed to assess the impact of urgency on early and midterm outcomes of the Candy-Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection. METHODS: The CP registry was reviewed, and patients were categorized into elective and urgent/emergent groups for analysis. End points included technical success, clinical success, early (30-day) computed tomography angiography findings, early (30-day) mortality, adverse events, and aortic remodeling in patients with available computed tomography angiography follow-up and reintervention. RESULTS: A total of 155 patients received a custom-made CP, of whom 32 patients (44% male, mean age 61 ± 9 years) were treated urgently and 123 patients (63% male, mean age 62 ± 11 years) electively. The primary CP rate was higher in the urgent group (28/32, 88%, in the urgent group vs 96/123, 78%, in the elective group, P = .051). The mean contrast volume was higher in the urgent group (157 ± 56 mL in the urgent group vs 130 ± 71 mL in the elective group, P = .017). Technical success was achieved in all patients in both groups. Clinical success was achieved in 25 of 32 (78%) patients in the urgent group vs 113 and 123 (92%) in the elective group (P = .159). The early mortality rate was 13% (4 of 32 patients) in the urgent group vs 1% (1 of 123 patients) in the elective group (P = .120). There was no statistically significant difference regarding the early adverse events between the urgent and elective CP groups. Early aortic-related reinterventions were required in 6 of 32 (19%) patients in the urgent group vs 6 of 123 (5%) in the elective group (P = .094). Thoracic aortic aneurysm sac regression was lower in the urgent group (5/28, 18%, in the urgent group vs 63/114, 55%, in the elective group, P = .001). Stable thoracic aortic aneurysm sac was higher in the urgent group (22/28, 79%, in the urgent group vs 47/114, 41%, in the elective group, P = .000). An increase in thoracic aortic aneurysm sac occurred in 1 of 28 (4%) patients in the urgent group vs 4 of 114 (4%) patients in the elective group (P = .096). CONCLUSIONS: The urgent use of the CP technique for distal FL occlusion in aortic dissection was feasible and effective. The decrease in aortic FL sac diameter may be affected by the urgent use of CP due to limited sizing availability. However, it achieved a high rate of aortic remodeling.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Sistema de Registros , Humanos , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Persona de Mediana Edad , Femenino , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Anciano , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Resultado del Tratamiento , Estudios Retrospectivos , Enfermedad Crónica , Factores de Tiempo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Prótesis Vascular , Factores de Riesgo , Stents , Diseño de Prótesis , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Electivos , Remodelación Vascular , Aortografía/métodos , Urgencias Médicas
4.
Artículo en Inglés | MEDLINE | ID: mdl-39321954

RESUMEN

OBJECTIVE: Despite the increasing number of fenestrated/branched endovascular aortic repair (f/bEVAR) procedures, evidence on post-operative antiplatelet therapy is lacking. This study aimed to investigate the role of single antiplatelet therapy (SAPT) vs. double antiplatelet therapy (DAPT) after f/bEVAR on 30 day and follow up outcomes. METHODS: A multicentre retrospective analysis was conducted, including f/bEVAR patients managed from 1 January 2018 to 31 December 2022. Comparative outcomes were assessed according to post-operative antiplatelet therapy. The cohort was divided into the SAPT group (acetylsalicylic acid [ASA] or clopidogrel) and DAPT group (ASA and clopidogrel). The duration of SAPT or DAPT was one to six months. Primary outcomes were 30 day death, and cardiovascular ischaemic and major haemorrhagic events. Secondary outcomes were survival and target vessel (TV) patency during follow up. RESULTS: A total of 1 430 patients were included: 955 under SAPT and 475 under DAPT. The 30 day mortality was similar (SAPT 2.1% vs. DAPT 1.5%; p = .42). Cardiovascular ischaemic events were lower in the DAPT group (SAPT 11.9% vs. DAPT 8.2%; p = .040), with DAPT being an independent protector for acute mesenteric (p = .009) and lower limb ischaemia (p = .020). No difference was found in 30 day major haemorrhagic events (SAPT 7.5% vs. DAPT 6.3%; p = .40). The mean follow up was 21.8 ± 2.9 months. Cox regression showed no cofounders on survival, with similar rates between groups (log rank p = .71). DAPT patients presented higher TV patency (SAPT 93.4%, standard error [SE] 0.7% vs. DAPT 96.6%, SE 0.7%; log rank p = .007) at thirty six months. Cox regression revealed bEVAR as a predictor of worse TV patency (hazard ratio 2.03, 95% confidence interval 1.36 - 3.03; p < .001). DAPT was related to higher patency within bEVAR patients (SAPT 87.2%, SE 2.1% vs. DAPT 94.9%, SE 1.9%; p < .001). CONCLUSIONS: DAPT after f/bEVAR was associated with lower risk of cardiovascular ischaemic events and higher TV patency, especially in bEVAR cases. No difference in major haemorrhagic events was observed at 30 days.

5.
Ann Vasc Surg ; 108: 519-556, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38942370

RESUMEN

BACKGROUND: Endovascular aortic repair (EVAR) requires extensive preoperative, intraoperative, and postoperative imaging for planning, surveillance, and detection of endo-leaks. There have been manyadvancements in imaging modalities to achieve this purpose. This review discussed different imaging modalities used at different stages of treatment of complex EVAR. METHODS: We conducted a literature review of all the imaging modalities utilized in EVAR by searching various databases. RESULTS: Preoperative techniques include analysis of images obtained via modified central line using analysis software and intravascular ultrasound. Fusion imaging (FI), carbon dioxide (CO2) angiography, intravascular ultrasound, and Fiber Optic RealShape (FORS) technology have been crucial in obtaining real-time imaging for the detection of endo-leaks during operative procedures. Conventional imaging modalities like computed tomography (CT) angiography (CTA) and magnetic resonance (MR) angiography are still employed for postoperative surveillance along with computational fluid dynamics and contrast-enhanced ultrasound (CEUS). The advancements in artificial intelligence (AI) have been the breakthrough in developing robust imaging applications. CONCLUSIONS: This review explains the advantages, disadvantages, and side-effect profile of the abovementioned imaging modalities.


Asunto(s)
Aortografía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Valor Predictivo de las Pruebas , Humanos , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Ultrasonografía Intervencional , Angiografía por Tomografía Computarizada , Inteligencia Artificial , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Diagnóstico por Imagen/métodos , Reparación Endovascular de Aneurismas
6.
Ann Surg ; 278(2): e396-e404, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35925761

RESUMEN

OBJECTIVE: To assess outcomes of fenestrated-branched endovascular aortic repair (FB-EVAR) of Extent I-III thoracoabdominal aortic aneurysms (TAAAs) without prophylactic cerebrospinal fluid drainage (CSFD). BACKGROUND: Prophylactic CSFD has been routinely used during endovascular TAAA repair, but concerns about major drain-related complications have led to revising this paradigm. METHODS: We reviewed a multicenter cohort of 541 patients treated for Extent I-III TAAAs by FB-EVAR without prophylactic CSFD. Spinal cord injury (SCI) was graded as ambulatory (paraparesis) or nonambulatory (paraplegia). Endpoints were any SCI, permanent paraplegia, response to rescue treatment, major drain-related complications, mortality, and patient survival. RESULTS: There were 22 Extent I, 240 Extent II and 279 Extent III TAAAs. Thirty-day mortality was 3%. SCI occurred in 45 patients (8%), paraparesis occurring in 23 (4%) and paraplegia in 22 patients (4%). SCI was more common in patients with Extent I-II compared with Extent III TAAAs (12% vs. 5%, P =0.01). Rescue treatment included permissive hypertension in all patients, with CSFD in 22 (4%). Symptom improvement was noted in 73%. Twelve patients (2%) had permanent paraplegia. Two patients (0.4%) had major drain-related complications. Independent predictors for SCI by multivariate logistic regression were sustained perioperative hypotension [odds ratio (OR): 4.4, 95% confidence interval (95% CI): 1.7-11.1], patent collateral network (OR: 0.3, 95% CI: 0.1-0.6), and total length of aortic coverage (OR: 1.05, 95% CI: 1.01-1.10). Patient survival at 3 years was 72%±3%. CONCLUSION: FB-EVAR of Extent I-III TAAAs without CSFD has low mortality and low rates of permanent paraplegia (2%). SCI occurred in 8% of patients, and rescue treatment improved symptoms in 73% of them.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Traumatismos de la Médula Espinal , Humanos , Procedimientos Endovasculares/efectos adversos , Factores de Riesgo , Aneurisma de la Aorta Abdominal/cirugía , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Paraplejía/etiología , Paraplejía/prevención & control , Paraplejía/cirugía , Pérdida de Líquido Cefalorraquídeo/complicaciones , Pérdida de Líquido Cefalorraquídeo/cirugía , Drenaje/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Estudios Multicéntricos como Asunto
7.
Ann Surg ; 278(2): e389-e395, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35837956

RESUMEN

OBJECTIVE: To report the mid-term outcomes of fenestrated-branched endovascular aneurysm repair (F-BEVAR) following a failed previous endovascular aneurysm repair (pEVAR) or previous open aneurysm repair (pOAR). METHODS: Data from consecutive patients who underwent F-BEVAR for pEVAR or pOAR from 2006 to 2021 from 17 European vascular centers were analyzed. Endpoints included technical success, major adverse events, 30-day mortality, and 5-year estimates of survival, target vessel primary patency, freedom from reinterventions, type I/III endoleaks, and sac growth >5 mm. BACKGROUND: Treatment of a failed previous abdominal aortic aneurysm repair is a complex undertaking. F-BEVAR is becoming an increasingly attractive option, although comparative data are limited regarding associated risk factors, indications for treatment, and various outcomes. RESULTS: There were 526 patients included, 268 pOAR and 258 pEVAR. The median time from previous repair to F-BEVAR was 7 (interquartile range, 4-12) years, 5 (3-8) for pEVAR, and 10 (6-14) for pOAR, P <0.001. Predominant indication for treatment was type Ia endoleak for pEVAR and progression of the disease for pOAR. Technical success was 92.8%, pOAR (92.2%), and pEVAR (93.4%), P =0.58. The 30-day mortality was 6.5% overall, 6.7% for pOAR, and 6.2% for pEVAR, P =0.81. There were 1853 treated target vessels with 5-year estimates of primary patency of 94.4%, pEVAR (95.2%), and pOAR (94.4%), P =0.03. Five-year estimates for freedom from type I/III endoleaks were similar between groups; freedom from reintervention was lower for pEVAR (38.3%) than for pOAR (56.0%), P =0.004. The most common indication for reinterventions was for type I/III endoleaks (37.5%). CONCLUSIONS: Repair of a failed pEVAR or pOARis safe and feasible with comparable technical success and survival rates. While successful treatment can be achieved, significant rates of reintervention should be anticipated, particularly for issues related to instability of target vessels/bridging stents.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Endofuga/epidemiología , Endofuga/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Factores de Riesgo , Sistema de Registros , Estudios Retrospectivos , Diseño de Prótesis
8.
Ann Surg ; 278(4): 568-577, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37395613

RESUMEN

OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Estudios Retrospectivos , Prótesis Vascular
9.
J Vasc Surg ; 78(2): 300-312.e3, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37076108

RESUMEN

OBJECTIVE: To compare costs and effectiveness of elective open (OR) vs fenestrated/branched endovascular (ER) repair of thoracoabdominal aneurysms (TAAAs) in a high-volume center. METHODS: This single-center retrospective observational study (PRO-ENDO TAAA Study, NCT05266781) was designed as part of a larger health technology assessment analysis. All electively treated TAAAs between 2013 and 2021 were analyzed and propensity-matched. End points were clinical success, major adverse events (MAEs), hospital direct costs, and freedom from all causes and aneurysm-related mortality and reinterventions. Risk factors and outcomes were homogeneously classified according to the Society of Vascular Surgery reporting standards. Cost-effectiveness value and incremental cost-effectiveness ratio were calculated, considering the absence of MAEs as a measure of effectiveness. RESULTS: Propensity matching identified 102 pairs of patients out of 789 TAAAs. Mortality, MAE, permanent spinal cord ischemia rates, respiratory complications, cardiac complications, and renal injury were higher for OR (13% vs 5%, P = .048; 60% vs 17%, P < .001; 10% vs 3%, P = .045; 91% vs 18%, P < .001; 16% vs 6%, P = .024; 27% vs 6%, P < .001, respectively). Access complication rate (6% vs 27%; P < .001) was higher in the ER group. Intensive care unit stay was longer (P < .001) for OR, and ER patients were discharged home more frequently (3% vs 94%; P < .001). No differences in midterm end points were observed at 2 years. Despite ER reducing all the hospital cost items (-42% to -88%, P < .001), the higher expenses (P < .001) of the endovascular devices increased the overall cost of ER by 80%. Cost-effectiveness value for ER was favorable to OR (56,365 vs 64,903 €/patient) with an incremental cost-effectiveness ratio of 48,409 € per MAE saved. CONCLUSIONS: ER of TAAA reduces perioperative mortality and morbidity compared with OR, with no differences in reinterventions and survival rates at midterm follow-up. Despite the expenses for endovascular grafts, ER was found to be more cost-effective in preventing MAEs.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Stents/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Análisis de Costo-Efectividad , Resultado del Tratamiento , Complicaciones Posoperatorias , Aneurisma/cirugía , Factores de Riesgo , Hospitales , Estudios Retrospectivos
10.
J Vasc Surg ; 77(6): 1598-1606.e3, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36822256

RESUMEN

OBJECTIVE: To investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent. METHODS: The COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier: NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards. RESULTS: Two hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001). CONCLUSIONS: The use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Femenino , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Factores de Riesgo , Grado de Desobstrucción Vascular , Diseño de Prótesis , Resultado del Tratamiento , Stents , Italia , Procedimientos Endovasculares/efectos adversos , Sistema de Registros
11.
J Vasc Surg ; 78(3): 584-592.e2, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37187414

RESUMEN

OBJECTIVE: To assess branch vessel outcomes after endovascular repair of complex aortic aneurysms analyzing possible factors influencing early and long-term results. METHODS: The Italian Multicentre Fenestrated and Branched registry enrolled 596 consecutive patients treated with fenestrated and branched endografts for complex aortic disease from January 2008 to December 2019 by four Italian academic centers. The primary end points of the study were technical success (defined as target visceral vessel [TVV] patency and absence of bridging device-related endoleak at final intraoperative control), and freedom from TVV instability (defined as the combined results of type IC/IIIC endoleaks and patency loss) during follow-up. Secondary end points were overall survival and TVV-related reinterventions. RESULTS: We excluded 591 patients (3 patients with a surgical debranching and 2 patients who died before completion from the study cohort) were treated for a total of 1991 visceral vessels targeted by either a directional branch or a fenestration. The overall technical success rate was 98.4%. Failure was related to the use of an off-the-shelf (OTS) device (custom-made device vs OTS, HR, 0.220; P = .007) and a preoperative TVV stenosis of >50% (HR, 12.460; P < .001). The mean follow-up time was 25.1 months (interquartile range, 3-39 months). The overall estimated survival rates were 87%, 77.4%, and 67.8% at 1, 3, and 5 years, respectively (standard error [SE], 0.015, 0.022, and 0.032). During follow-up, TVV branch instability was observed in 91 vessels (5%): 48 type IC/IIIC endoleaks (2.6%) and 43 stenoses-thromboses (2.4%). The extent of aneurysm disease (thoracoabdominal aortic aneurysm [TAAA] types I-III vs TAAA type IV/juxtarenal aortic aneurysm/pararenal aortic aneurysm) was the only independent predictor for developing a TVV-related type IC/IIIC endoleak (HR, 3.899; 95% confidence interval [CI]:, 1.924-7.900; P < .001). Risk of patency loss was independently associated with branch configuration (HR, 8.883; P < .001; 95% CI, 3.750-21.043) and renal arteries (HR, 2.848; P = .030; 95% CI, 1.108-7.319). Estimated rates at 1, 3, and 5 years of freedom from TVV instability and freedom from TVV-related reintervention were 96.6%, 93.8%, and 90% (SE, 0.005, 0.007, and 0.014) and 97.4%, 95.0%, and 91.6% (SE, 0.004, 0.007, and 0.013), respectively. CONCLUSIONS: Intraoperative failure to bridge a TVV was associated with a preoperative TVV stenosis of >50% and the use of OTS devices. Midterm outcomes were satisfying, with an estimated 5-year freedom from TVV instability and reintervention of 90.0% and 91.6%, respectively. During follow-up, the larger extent of aneurysm disease was associated with an increased risk of TVV-related endoleaks, whereas a branch configuration and renal arteries were more prone to patency loss.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Endofuga/etiología , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Constricción Patológica/etiología , Factores de Riesgo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Resultado del Tratamiento , Diseño de Prótesis
12.
J Vasc Surg ; 78(4): 863-873.e3, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37330705

RESUMEN

OBJECTIVE: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Femenino , Prótesis Vascular , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Estudios de Cohortes , Resultado del Tratamiento , Factores de Tiempo , Diseño de Prótesis
13.
J Vasc Surg ; 77(6): 1588-1597.e4, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36731757

RESUMEN

OBJECTIVE: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. RESULTS: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. CONCLUSIONS: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Prótesis Vascular , Aneurisma/cirugía , Estudios Retrospectivos , Diseño de Prótesis
14.
J Endovasc Ther ; 30(6): 811-816, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-35707893

RESUMEN

PURPOSE: To describe the implantation steps of the latest generation of candy-plug device (third CP generation [CP III]) and to illustrate its possible pitfalls by discussing a case in whom this device was employed to occlude the false lumen (FL) of a chronic type B aortic dissection. TECHNIQUE: A 69 year-old male patient who underwent a frozen elephant trunk arch repair due to residual type A aortic dissection developed a FL aneurysmal degeneration limited to the descending thoracic aorta. Two thoracic stent-grafts were deployed into the true lumen up to the celiac trunk origin. Then, the FL was occluded with a self-occluding CP III device (Cook Medical, Bloomington, Indiana), placed at the same level as the distal thoracic stent-graft. The distal un-stented sleeve was pushed upward to allow immediate occlusion of its central lumen, avoiding interference with reno-visceral arteries arising from the FL. Both intraoperative transesophageal echocardiography and follow-up computed tomographic angiography scan demonstrated complete FL thrombosis. CONCLUSION: The introduction of CP III with its self-occluding mechanism helped to shorten and standardize the procedure. However, adjunctive steps may be needed to immediately obtain FL occlusion and avoid hampering the perfusion of vessels arising from the FL.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Trombosis , Masculino , Humanos , Anciano , Prótesis Vascular , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Stents , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía , Estudios Retrospectivos
15.
J Endovasc Ther ; : 15266028231214162, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38031973

RESUMEN

PURPOSE: Preliminary results of the INSIGHT study showed that the low-profile INCRAFT Abdominal Aortic Aneurysm (AAA) Stent-Graft System was safe and effective in the endovascular aneurysm repair (EVAR). This study aimed to assess the durability and the midterm effectiveness of EVAR using the INCRAFT System in the framework of a multicenter, prospective, open-label, post-approval study. MATERIALS AND METHODS: Between 2015 and 2016, 150 subjects from 23 European centers treated with the INCRAFT System for an infrarenal AAA were included. Clinical and radiologic data were prospectively collected and analyzed using protocol-specified, monitored follow-up clinic visits at 1, 6, and 12 months post-implantation and annually after that. The clinical success at 3 years was determined. Freedom from overall and aneurysm-related mortality, type I endoleak, secondary interventions, and aneurysm sac enlargement through 3 years were evaluated. Kaplan-Meier estimates were used for late outcomes. An independent clinical events committee reviewed all events. The CT (computed tomography) scans through 1 year were reviewed by an independent core laboratory. RESULTS: The primary clinical success rate at 3 years was 84.0% (126/150). There were no aneurysm-related deaths, endograft migration, or aneurysm-related ruptures through 3 years. Stent fracture was detected in 2 subjects (1.3%) without clinical sequelae. Over 3 years, freedom from overall mortality was 89.4%, freedom from secondary interventions was 80%, and freedom from aneurysm sac enlargement was 96.5%. The 3-year freedom from type IA and IB endoleaks was 93.3% and 98.6%, respectively. CONCLUSIONS.: In a multicenter real-world study setting, the use of a low-profile INCRAFT device for AAA is associated with sustained clinical success and low rates of reinterventions through 3 years. CLINICAL IMPACT: Low-profile endografts have broadened the spectrum of patients with anatomic suitability for endovascular repair of abdominal aortic aneurysms (AAA). However, questions remain regarding the durability of the repair. The INSIGHT study evaluated the use of the INCRAFT System in routine real-world clinical practice, including patients with complex anatomies. The treatment was safe and effective. The results showed sustained clinical success over 3 years, with no aneurysm-related deaths or ruptures, and a high rate of intervention-free survival at 3 years. Despite the low-profile design of the endograft, the midterm results demonstrate the durability of AAA repair using the INCRAFT System.ClinicalTrials.gov Identifier: NCT02477111.

16.
J Endovasc Ther ; 30(6): 817-821, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-35698790

RESUMEN

The absence of an adequate ileo-femoral access is usually considered an absolute contraindication to fenestrated and branched aortic repairs. Alternative routes and dedicated stent-graft designs have been advocated. Hereby, we describe the case of a 73-year-old man with a recurrent type IV thoracoabdominal aortic aneurysm and complete thrombotic pararenal aortic occlusion treated successfully with a tri-branch custom-made endograft deployed via a transaxillary access.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Prótesis Vascular , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Factores de Riesgo , Resultado del Tratamiento , Stents , Diseño de Prótesis , Arteriopatías Oclusivas/cirugía
17.
J Endovasc Ther ; : 15266028231202456, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37750487

RESUMEN

PURPOSE: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT: Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.

18.
J Endovasc Ther ; : 15266028231217233, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38062565

RESUMEN

OBJECTIVE: To report on the recommendations of an expert-based consensus on the indications, timing, and techniques of aortic balloon occlusion (ABO) in the management of ruptured abdominal aortic aneurysms (rAAA). METHODS: Eleven facilitators created appropriate statements regarding the study issues that were voted on using a 4-point Likert scale with open-comment fields, by a selected panel of international experts (vascular surgeons and interventional radiologists) using a 3-round modified Delphi consensus procedure (study period: January-April 2023). Based on the experts' responses, only the statements reaching grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final study report. The consistency of each round's answers was also graded using Cohen's kappa, the intraclass correlation coefficient, and, in case of double resubmission, Fleiss kappa. RESULTS: Sixty-three experts were included in the final analysis and voted on 25 statements related to indication and timing (n=6), and techniques (n=19) of ABO in the setting of rAAA. Femoral sheath or ABO should be preferably placed in the operating room, via a percutaneous transfemoral access, on a stiff wire (grade B, consistency I), ABO placement should be suprarenal and last less than 30 minutes (grade B, consistency II), postoperative peripheral vascular status (grade A, consistency II) and laboratory testing every 6 to 12 hours (grade B, consistency) should be assessed to detect complications. Formal training for ABO should be implemented (grade B, consistency I). Most of the statements in this international expert-based Delphi consensus study might guide current choices for indications, timing, and techniques of ABO in the management of rAAA. Clinical practice guidelines should incorporate dedicated statements that can guide clinicians in decision-making. CONCLUSIONS: At arrival and during both open or endovascular procedures for rAAA, selective use of intra-aortic balloon occlusion is recommended, and it should be performed preferably by the treating physician in aortic pathology. CLINICAL IMPACT: This is the first consensus study of international vascular experts aimed at defining the indications, timing, and techniques of optimal use of ABO in the clinical setting of rAAA. Aortic occlusion by endovascular means (or ABO) is a quick procedure in properly trained hands that may play an important role as a temporizing measure until the definitive aortic repair is achieved, whether by endovascular or open means. Since data on its use in hemodynamically unstable patients are limited in the literature, owing to practical challenges in the performance of well-conducted prospective studies, understanding real-world use by experts is of importance in addressing critical issues and identifying main gaps in knowledge.

19.
J Endovasc Ther ; 30(2): 281-288, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35236159

RESUMEN

PURPOSE: The aim of this study is to report an Italian multicenter experience analyzing the incidence and the risk factors associated with spinal cord ischemia (SCI) in a large cohort of thoracoabdominal aortic aneurysms (TAAAs) treated by fenestrated-branched endovascular aneurysm repair (F-/B-EVAR). MATERIALS AND METHODS: All consecutive patients undergoing F-/B-EVAR in 4 Italian university centers between 2008 and 2019 were prospectively recorded and retrospectively analyzed. Spinal cord ischemia, 30 day/in-hospital adverse events, and mortality were assessed as early outcomes. Risk factors for SCI were determined by multivariable analysis. RESULTS: A total of 351 patients received F-/B-EVAR for a TAAA. Twenty-eight (8.0%) patients died within 30 postoperative days or during the hospitalization. Regarding SCI, 47 patients (13.4%) developed neurological symptoms related to spinal cord impaired perfusion. Among them, 17 (4.8%) had a major permanent impairment. The multivariable analysis identified that SCI was associated with Crawford extent I to III (odds ratio [OR]: 20.90, p=0.004, 95% confidence interval [CI]=2.69-162.57), and with endovascular procedures performed for ruptured TAAA (OR: 5.74, p=0.010, 95% CI=1.53-21.57). Spinal cord ischemia was also significantly associated with a grade 3 bleeding during the visceral stage (OR: 4.34, p=0.005, 95% CI=1.55-12.16) and a grade 2 renal insufficiency at 30 days (OR: 7.45, p=0.002, 95% CI=2.12-26.18). CONCLUSION: The present study indicates that SCI is still an open issue after extent I to III TAAA endovascular repair, while its incidence in extent IV TAAA and pararenal/juxtarenal aneurysms is rare. Thoracoabdominal aortic aneurysms extension, urgent TAAA repair for rupture, severe bleeding, and 30 day renal insufficiency have been identified as significant risk factors for SCI. In the presence of such factors, adjunctive strategies may be considered to reduce SCI rates, while in low-risk patients invasive or potentially-risky maneuvers might not be justified.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Insuficiencia Renal , Isquemia de la Médula Espinal , Humanos , Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Isquemia de la Médula Espinal/diagnóstico por imagen , Isquemia de la Médula Espinal/epidemiología , Isquemia de la Médula Espinal/etiología , Factores de Riesgo , Insuficiencia Renal/complicaciones , Insuficiencia Renal/cirugía , Sistema de Registros
20.
Eur J Vasc Endovasc Surg ; 66(1): 50-56, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36958480

RESUMEN

OBJECTIVE: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. METHODS: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. RESULTS: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 - 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 - 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. CONCLUSION: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.


Asunto(s)
Aneurisma Falso , Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Stents , Aneurisma Falso/cirugía , Procedimientos Endovasculares/métodos , Aortografía/métodos , Resultado del Tratamiento , Prótesis Vascular
SELECCIÓN DE REFERENCIAS