Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Vaccine Immunol ; 14(5): 505-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17376860

RESUMEN

The advent of multiplexed bead assays in recent years has introduced a new dimension of testing for complex diseases such as lupus, which can involve multiple autoantibodies. The ability to rapidly identify multiple autoantibodies, with high sensitivity and specificity in an automated fashion, is highly attractive. The aim of this study was to assess the performance and clinical value of multiplexed bead-based (AtheNA Multi-Lyte ANA-II test system) immunoassays both by comparing the results with those achieved by indirect fluorescent-antibody assay (IFA) or conventional enzyme immunoassays (EIAs) and by independent identification of autoantibodies in well-characterized samples. To achieve this goal, 984 samples were tested for seven analytes (SS/A, SS/B, Sm, RNP, Scl-70, double-stranded DNA [dsDNA], and centromere B) in both traditional and bead-based assays. The average concordance for the different analytes was 91%, ranging from 81% (dsDNA) to 97% (centromere B). The average relative specificity and sensitivity for the analytes were also high, 92% and 81%, respectively. An examination of 93 "normal controls" demonstrated a 7% false-positive rate, which was comparable to IFA. Percentages of different autoantibodies found in patients with a variety of disease conditions (34 with calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia; 41 with mixed connective tissue disease; 24 with scleroderma; and 35 with Sjogren's syndrome) were well within the range expected from each group. A scrutiny of results from AtheNA and EIA and Farr results for 185 systemic lupus erythematosus samples revealed comparable results by both methods, with the exception of SS/A and dsDNA, where AtheNA had a higher percentage of SS/A-positive results compared to EIA (51% versus 29%) and a lower percentage of dsDNA-positive results (18% versus 28% at a cutoff of 5 IU/ml).


Asunto(s)
Anticuerpos Antinucleares/inmunología , Antígenos Nucleares/inmunología , Autoanticuerpos/inmunología , Enfermedades del Sistema Inmune/diagnóstico , Vasculitis/inmunología , Estudios de Casos y Controles , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Humanos , Enfermedades del Sistema Inmune/inmunología , Técnicas para Inmunoenzimas/métodos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA