RESUMEN
AIMS: The role of antiplatelet therapy in patients with spontaneous coronary artery dissection (SCAD) undergoing initial conservative management is still a matter of debate, with theoretical arguments in favour and against its use. The aims of this article are to assess the use of antiplatelet drugs in medically treated SCAD patients and to investigate the relationship between single (SAPT) and dual (DAPT) antiplatelet regimens and 1-year patient outcomes. METHODS AND RESULTS: We investigated the 1-year outcome of patients with SCAD managed with initial conservative treatment included in the DIssezioni Spontanee COronariche (DISCO) multicentre international registry. Patients were divided into two groups according to SAPT or DAPT prescription. Primary endpoint was 12-month incidence of major adverse cardiovascular events (MACE) defined as the composite of all-cause death, non-fatal myocardial infarction (MI), and any unplanned percutaneous coronary intervention (PCI). Out of 314 patients included in the DISCO registry, we investigated 199 patients in whom SCAD was managed conservatively. Most patients were female (89%), presented with acute coronary syndrome (92%) and mean age was 52.3 ± 9.3 years. Sixty-seven (33.7%) were given SAPT whereas 132 (66.3%) with DAPT. Aspirin plus either clopidogrel or ticagrelor were prescribed in 62.9% and 36.4% of DAPT patients, respectively. Overall, a 14.6% MACE rate was observed at 12 months of follow-up. Patients treated with DAPT had a significantly higher MACE rate than those with SAPT [18.9% vs. 6.0% hazard ratios (HR) 2.62; 95% confidence intervals (CI) 1.22-5.61; P = 0.013], driven by an early excess of non-fatal MI or unplanned PCI. At multiple regression analysis, type 2a SCAD (OR: 3.69; 95% CI 1.41-9.61; P = 0.007) and DAPT regimen (OR: 4.54; 95% CI 1.31-14.28; P = 0.016) resulted independently associated with a higher risk of 12-month MACE. CONCLUSIONS: In this European registry, most patients with SCAD undergoing initial conservative management received DAPT. Yet, at 1-year follow-up, DAPT, as compared with SAPT, was independently associated with a higher rate of adverse cardiovascular events (ClinicalTrial.gov id: NCT04415762).
Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/tratamiento farmacológico , Adulto , Vasos Coronarios , Disección , Quimioterapia Combinada , Femenino , Humanos , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sistema de Registros , Resultado del TratamientoRESUMEN
The objective of this study is to evaluate completeness of coronary revascularization in patients with complex stable coronary artery disease (SCAD) who underwent percutaneous coronary interventions (PCI), but a surgical revascularization indicated according to 2018 European Society of Cardiology guidelines. The optimal mode of revascularization for SCAD should take into account clinical, anatomic, and procedural characteristics-including anticipated completeness of revascularization-and modality of treatment should be discussed by a Heart Team. Among patients enrolled in the APpropriAteness of percutaneous Coronary interventions in patients with ischemic heart disease study, we identified patients with complex SCAD. Rates of ad-hoc PCI and documented heart team discussion were reported stratified by guideline recommended mode of revascularization. Completeness of revascularization was assessed by an angiographic core laboratory using residual SS (rSS) ≤ 8 and SYNTAX Revascularization Index (SRI) ≥ 70%. Among 336 PCI patients with SCAD, 182 (54.2%) had complex coronary disease and 152 underwent ad-hoc PCI (83.5%). Patients for whom surgery was the recommended revascularization option (9.3%) had a significantly and substantial higher rate of incomplete revascularization than patients for whom either mode of revascularization or PCI was recommended (61.3% vs 23.6% with rSS > 8, p < 0.001 and 77.4% vs 44.6% with SRI < 70%, p < 0.001). Patients with complex SCAD receiving percutaneous myocardial revascularization when surgery was recommended have substantially incomplete myocardial revascularization. These data support multidisciplinary decision-making in these patients and suggest considering anticipated completeness when deciding mode of coronary revascularization.
Asunto(s)
Puente de Arteria Coronaria/normas , Enfermedad de la Arteria Coronaria/terapia , Adhesión a Directriz/normas , Intervención Coronaria Percutánea/normas , Guías de Práctica Clínica como Asunto/normas , Pautas de la Práctica en Medicina/normas , Anciano , Toma de Decisiones Clínicas , Angiografía Coronaria/normas , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del TratamientoRESUMEN
AIMS: AUGMENT-HF was an international, multi-centre, prospective, randomized, controlled trial to evaluate the benefits and safety of a novel method of left ventricular (LV) modification with alginate-hydrogel. METHODS: Alginate-hydrogel is an inert permanent implant that is directly injected into LV heart muscle and serves as a prosthetic scaffold to modify the shape and size of the dilated LV. Patients with advanced chronic heart failure (HF) were randomized (1 : 1) to alginate-hydrogel (n = 40) in combination with standard medical therapy or standard medical therapy alone (Control, n = 38). The primary endpoint of AUGMENT-HF was the change in peak VO2 from baseline to 6 months. Secondary endpoints included changes in 6-min walk test (6MWT) distance and New York Heart Association (NYHA) functional class, as well as assessments of procedural safety. RESULTS: Enrolled patients were 63 ± 10 years old, 74% in NYHA functional class III, had a LV ejection fraction of 26 ± 5% and a mean peak VO2 of 12.2 ± 1.8 mL/kg/min. Thirty-five patients were successfully treated with alginate-hydrogel injections through a limited left thoracotomy approach without device-related complications; the 30-day surgical mortality was 8.6% (3 deaths). Alginate-hydrogel treatment was associated with improved peak VO2 at 6 months-treatment effect vs. CONTROL: +1.24 mL/kg/min (95% confidence interval 0.26-2.23, P = 0.014). Also 6MWT distance and NYHA functional class improved in alginate-hydrogel-treated patients vs. Control (both P < 0.001). CONCLUSION: Alginate-hydrogel in addition to standard medical therapy for patients with advanced chronic HF was more effective than standard medical therapy alone for improving exercise capacity and symptoms. The results of AUGMENT-HF provide proof of concept for a pivotal trial. TRIAL REGISTRATION NUMBER: NCT01311791.
Asunto(s)
Alginatos/administración & dosificación , Insuficiencia Cardíaca/terapia , Hidrogel de Polietilenoglicol-Dimetacrilato/administración & dosificación , Ecocardiografía , Prueba de Esfuerzo , Tolerancia al Ejercicio/fisiología , Femenino , Ácido Glucurónico/administración & dosificación , Insuficiencia Cardíaca/fisiopatología , Ácidos Hexurónicos/administración & dosificación , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Seguridad del Paciente , Estudios Prospectivos , Prótesis e Implantes , Calidad de Vida , Resultado del Tratamiento , Caminata/fisiologíaRESUMEN
BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.
Asunto(s)
Válvula Aórtica , Cateterismo Periférico , Arteria Femoral , Punciones , Radiografía Intervencional , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Ultrasonografía Intervencional , Humanos , Arteria Femoral/diagnóstico por imagen , Masculino , Femenino , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Anciano , Fluoroscopía , Resultado del Tratamiento , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Factores de Riesgo , Radiografía Intervencional/efectos adversos , Prótesis Valvulares Cardíacas , Factores de Tiempo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Diseño de PrótesisRESUMEN
INTRODUCTION: Spontaneous coronary artery dissection (SCAD) is a rare cause of acute myocardial infarction (AMI), which primarily affects young women without traditional cardiovascular risk factors, often presenting as sudden cardiac death. This study aims to investigate the prevalence, characteristics, predictors, and outcomes of cardiac arrest in SCAD patients. METHODS: The DISCO IT/SPA registry, an international retrospective multicenter study, enrolled 375 SCAD patients from 26 centers in Italy and Spain. Patients were categorized based on the presence or absence of cardiac arrest at admission. Data on demographics, clinical presentation, treatment, angiographic findings, and outcomes were collected. Angiograms were independently reviewed, and outcomes included major adverse cardiovascular events (MACE) and in-hospital bleeding. RESULTS: Among 375 SCAD patients, 20 (5.3%) presented with cardiac arrest. Both groups were similar in age, gender distribution, and conventional risk factors, except for a lower prevalence of dyslipidemia in the cardiac arrest group. ST-segment elevation myocardial infarction (STEMI) presentation and angiographic type 2b were independent predictors of cardiac arrest. Revascularization was more frequent in the cardiac arrest group. In-hospital outcomes, except for longer hospitalization, did not differ. On follow-up (average 21 months), MACE rates were similar between groups. CONCLUSIONS: Cardiac arrest is a notable complication in SCAD, mostly presenting with ventricular fibrillation. The prognosis of SCAD patients presenting with cardiac arrest did not differ from those without, reporting a similar rate of events both in-hospital and during long-term follow-up. STEMI presentation and angiographic type 2b were identified as independent predictors of cardiac arrest in SCAD.
Asunto(s)
Anomalías de los Vasos Coronarios , Paro Cardíaco , Sistema de Registros , Enfermedades Vasculares , Humanos , Femenino , Masculino , Paro Cardíaco/epidemiología , Paro Cardíaco/etiología , Persona de Mediana Edad , Estudios Retrospectivos , Anomalías de los Vasos Coronarios/epidemiología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/diagnóstico , Enfermedades Vasculares/congénito , Enfermedades Vasculares/epidemiología , Enfermedades Vasculares/diagnóstico , Enfermedades Vasculares/complicaciones , Adulto , España/epidemiología , Anciano , Italia/epidemiología , Angiografía Coronaria/métodos , Estudios de Seguimiento , Factores de RiesgoRESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios RetrospectivosRESUMEN
BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Anciano de 80 o más Años , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Estudios de SeguimientoRESUMEN
BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de RegistrosRESUMEN
BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda , Factores de Tiempo , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/métodosRESUMEN
BACKGROUND: Hyponatremia is a well known predictor of short-term outcomes in heart failure (HF); however, its impact on long-term survival in HF patients with systolic dysfunction is not well established. METHODS AND RESULTS: Using the Duke Databank for Cardiovascular Diseases, we identified 1,045 patients with HF and systolic dysfunction undergoing cardiac catheterization from January 2000 through December 2008. The effect of hyponatremia as independent predictor of all-cause death and cardiovascular death/rehospitalization was examined using a multivariable Cox proportional regression model. Hyponatremia was present in 107/1,045 patients (10.2%). Hyponatremic patients were older, more likely to be anemic, with higher heart rate and levels of blood urea nitrogen, lower blood pressure, and more severe HF. Using an unadjusted analysis, hyponatremia was associated with higher risk of all-cause death (hazard ratio [HR] 1.89, 95% confidence interval [CI] 1.44-2.49; P < .0001) and of cardiovascular death/rehospitalization (HR 1.40, 95% CI 1.11-1.77; P = .005) at 4.5 years. When entered into a multivariable Cox model, hyponatremia remained significant for all-cause death (HR 1.42, 95% CI 1.07-1.88) and for cardiovascular death/rehospitalization (HR 1.45, 95% CI 1.14-1.86). CONCLUSIONS: Hyponatremia is relatively common in HF patients with LV dysfunction and is independently associated with increased risk of all-cause mortality and cardiovascular mortality/rehospitalization.
Asunto(s)
Insuficiencia Cardíaca/mortalidad , Hiponatremia/complicaciones , Anciano , Cateterismo Cardíaco , Enfermedad Crónica , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Hospitalización , Humanos , Hiponatremia/fisiopatología , Masculino , Persona de Mediana Edad , North Carolina , Modelos de Riesgos Proporcionales , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Disfunción Ventricular Izquierda/fisiopatologíaRESUMEN
Heart failure is one of the most common, costly, disabling and growing diseases (McMurray and Pfeffer in Lancet 365(9474):1877-1889, 2005). Hyponatremia, conventionally defined as a serum-sodium concentration equal or less than 135 mmol/l (American Heart Association in Heart disease and stroke statistics--2007 update. American Heart Association, Dallas, 2007; Stewart et al. in Eur J Heart Fail 4:361-371, 2002), is a common phenomenon in patients with heart failure, with an incidence of 20-25% (Krumholz et al. in Arch Intern Med 157:e99-e104, 1997; Rosamond et al. in Circulation 117(4):e25-e146, 2008; Adrogue and Madias in N Engl J Med 342:1581-1589, 2000) and seems to be of prognostic importance in patients with heart failure (Luca et al. in Am J Cardiol 96:19L-23L, 2005; Gheorghiade et al. in Eur Heart J 28:980-988, 2007; Gheorghiade et al. in Arch Intern Med 167:1998-2005, 2007). So far treatment strategies have been limited and burdened by side effects. The development of hyponatremia in the setting of heart failure is related to the arginine vasopressin (AVP) dysregulation. Thus, AVP receptor antagonists are a promising approach to treatment. However, several questions remain: whether there is a cause-and-effect mechanism, if the correction of hyponatremia improves outcomes, and defining the specific cut-off level of serum-sodium that should be used to define hyponatremia. In this review, we aim to summarize the literature on hyponatremia in patients with heart failure within several aspects: incidence in clinical trials and registries, prognostic value, underlying mechanisms, therapeutic options, and possible future perspectives.
Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Hiponatremia/fisiopatología , Antagonistas de los Receptores de Hormonas Antidiuréticas , Insuficiencia Cardíaca/complicaciones , Humanos , Hiponatremia/complicaciones , Modelos Teóricos , Pronóstico , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
Renal dysfunction is often present and/or worsens in patients with heart failure and this is associated with increased costs of care, complications and mortality. The cardiorenal syndrome can be defined as the presence or development of renal dysfunction in patients with heart failure. Its mechanisms are likely related to low cardiac output, increased venous congestion and renal venous pressure, neurohormonal and inflammatory activation and local changes, such as adenosine release. Many drugs, including loop diuretics, may contribute to worsening renal function through the activation of some of these mechanisms. Renal damage is conventionally defined by the increase in creatinine and blood urea nitrogen blood levels. However, these changes may be not related with renal injury or prognosis. New biomarkers of renal injury seem promising but still need to be validated. Thus, despite the epidemiological evidence, we are still lacking of satisfactory tools to assess renal injury and function and its prognostic significance.
Asunto(s)
Síndrome Cardiorrenal/fisiopatología , Creatinina/sangre , Insuficiencia Cardíaca/complicaciones , Riñón/fisiopatología , Insuficiencia Renal/complicaciones , Biomarcadores/sangre , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Humanos , Pruebas de Función Renal , Pronóstico , Insuficiencia Renal/tratamiento farmacológico , Insuficiencia Renal/fisiopatología , Factores de RiesgoRESUMEN
Most patients with heart failure (HF) already have or develop renal dysfunction; this might contribute to their poor outcome. Current treatment for HF can also contribute to worsen renal function. High furosemide doses are traditionally associated with worsening renal function (WRF), but patients with fluid overload may benefit of aggressive fluid removal. Unfortunately, promising therapies like vasopressin antagonists and adenosine antagonists have not been demonstrated to improve outcomes. Likewise, correction of low renal blood flow through dopamine, inotropic agents, or vasodilators does not seem to be associated with a clear benefit. However, transient WRF associated with acute HF treatment may not necessarily portend a poor prognosis. In this review, we focus on the strategies to detect renal dysfunction in acute HF, the underlying pathophysiological mechanisms, and the potential treatments.
Asunto(s)
Insuficiencia Cardíaca/tratamiento farmacológico , Enfermedades Renales/etiología , Riñón/fisiopatología , Antagonistas de Receptores de Mineralocorticoides/uso terapéutico , Vasodilatadores/uso terapéutico , Enfermedad Aguda , Adenosina/antagonistas & inhibidores , Biomarcadores/metabolismo , Cardiotónicos/uso terapéutico , Diuréticos/uso terapéutico , Dopamina/uso terapéutico , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Enfermedades Renales/tratamiento farmacológico , Pronóstico , Vasopresinas/antagonistas & inhibidoresRESUMEN
Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a step-by-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
OBJECTIVES: Recent heart failure studies have suggested that inflammatory and immune system activation are associated with increased levels of cytokines, chemokines and inflammatory proteins during acutely decompensated heart failure. The objectives of this substudy were to evaluate the role of neurohormonal and inflammatory activation in the pathogenesis and outcome of acute heart failure (AHF) and the correlation between biomarker levels and clinical outcomes. METHODS: Serum levels of B-type natriuretic peptide-32 (BNP-32), endothelin-1 (ET-1), norepinephrine, troponins I and T, C-reactive protein (CRP), von Willebrand factor, plasminogen activator inhibitor-1, interleukin-6 (IL-6) and tissue plasminogen activator (TPA) were measured at baseline, 24 and 48 h and 7 and 30 days in 112 patients with AHF recruited to the Value of Endothelin Receptor Inhibition with Tezosentan in Acute Heart Failure Study neurohormonal substudy. RESULTS: On univariable analysis, CRP, BNP and ET-1 were predictive of worsening heart failure by day 30; when considered together, only CRP and BNP were significantly associated with this outcome. On adjustment for age, baseline blood pressure, serum sodium and serum creatinine, only age and BNP remained significant. CRP, IL-6 and TPA levels were significantly correlated with 180-day mortality on univariable analysis. CONCLUSION: Circulating markers of inflammation may be useful in gauging prognosis in patients with AHF.
Asunto(s)
Biomarcadores/sangre , Insuficiencia Cardíaca/sangre , Neurotransmisores/sangre , Anciano , Anciano de 80 o más Años , Proteína C-Reactiva/análisis , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Inmunoensayo , Interleucina-6/sangre , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Norepinefrina/sangre , Inhibidor 1 de Activador Plasminogénico/sangre , Pronóstico , Modelos de Riesgos Proporcionales , Ensayos Clínicos Controlados Aleatorios como Asunto , Activador de Tejido Plasminógeno/sangre , Troponina I/sangre , Factor de von Willebrand/análisisRESUMEN
Despite the epidemiologic importance, large investments, and careful design, recent results of heart failure (HF) trials have been unable to demonstrate significant treatment improvements. This shortcoming has led to a reassessment of research methodology, particularly related to sample size and costs, for which end-point selection is a main issue. In comparing interventions in clinical trials, surrogate end points may be used to reduce the costs. To this end, ongoing research into the roles of imaging biomarkers as reliable surrogate end points may lead to better clinical trial design and more efficient development of new therapies for HF.
Asunto(s)
Biomarcadores/metabolismo , Insuficiencia Cardíaca/diagnóstico , Ensayos Clínicos como Asunto , Progresión de la Enfermedad , Insuficiencia Cardíaca/metabolismo , Humanos , Índice de Severidad de la EnfermedadRESUMEN
Arterial vasospasm is a well known cause of ischemia and, if prolonged, of parenchymal infarction. The clinical presentation varies according to the involved arterial district. We describe a rare case, which occurred in a young lady, of recurrent and multisystem vasospasm, resulting in multiple cerebral and myocardial infarctions. Our patient was resistant to medical therapy, requiring stent implantation of the involved vessels.
Asunto(s)
Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Encéfalo , Arterias Carótidas , Vasoespasmo Coronario , Vasoespasmo Intracraneal , Adulto , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/terapia , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/métodos , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Bloqueadores de los Canales de Calcio/uso terapéutico , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiopatología , Arterias Carótidas/cirugía , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Vasoespasmo Coronario/diagnóstico por imagen , Vasoespasmo Coronario/etiología , Vasoespasmo Coronario/fisiopatología , Resistencia a Medicamentos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Paro Cardíaco Extrahospitalario/terapia , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Recurrencia , Stents , Resultado del Tratamiento , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/etiología , Vasoespasmo Intracraneal/fisiopatologíaRESUMEN
BACKGROUND: Coronavirus disease 2019 (COVID-19) has shown high morbidity and mortality and the relationship between pulmonary embolism (PE) and COVID-19 is well established in the literature. METHODS: We describe the characteristics of a cohort of COVID-19 patients (EP-COV) hospitalized at our Centre with PE, investigating how COVID-19 may have influenced their outcomes, as compared to patients without COVID-19 hospitalized for PE in the same months of 2020 (EP-2020) and 2019 (EP-2019). RESULTS: EP-COV patients (n=25) were younger (60.5 ± 8.5 vs 71.4 ± 14.5 vs 70.9 ± 11.8 years, p=0.003), more frequently male (76% vs 48% vs 35%, p=0.016), with a lower history of neoplasia (12% vs 47% vs 40%, p=0.028) and more clinically severe (SOFA score 3.4 ± 1.4 vs 2.2 ± 1.4 vs 1 ± 1.1, p<0.001 and PaO2/FiO2 ratio 223.8 ± 75.5 vs 306.5 ± 49.3 vs 311.8 ± 107.5) than EP-2020 (n=17) and EP-2019 patients (n=20). D-dimer and C-reactive protein were higher in EP-COV (p=0.038 e p<0.001, respectively). The rate of concomitant deep vein thrombosis associated with PE did not differ significantly between the three groups. EP-COV patients developed PE more frequently during in-hospital stay than non-COVID-19 patients (p = 0.016). The mortality rate was higher in EP-COV than in EP-2020 and EP-2019 patients (36% vs 0% vs 5%, p=0.019). CONCLUSIONS: In our study, the risk factors for PE in COVID-19 patients seem to differ from the traditional risk factors for venous thromboembolism; EP-COV patients are clinically more severe and display a higher mortality rate than EP-2020 and EP-2019 patients.