Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Prosthet Dent ; 131(1): 144.e1-144.e9, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38167132

RESUMEN

STATEMENT OF PROBLEM: Microbial adhesion on occlusal devices may lead to oral diseases such as candidiasis. Whether chitosan and eugenol provide antibiofilm effects is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the biofilm formation of C. albicans strains on occlusal device materials and the antibiofilm effects of chitosan and eugenol against C. albicans on these surfaces. MATERIAL AND METHODS: A total of 88 specimens (5×10×2 mm) were produced from occlusal device materials with 4 production techniques: vacuum-formed thermoplastic (Group V), head-press (Group H), computer-aided design and computer-aided manufacture (CAD-CAM) (Group C), and 3-dimensionally (3D) printed (Group D) (n=22). After various finishing procedures, the surface properties of the specimens were evaluated by using surface free energy (SFE), surface roughness (SR) measurements, and elemental and topographic analysis. Biofilm formation of C. albicans strain and the antibiofilm effects of chitosan and eugenol against biofilm formation on these surfaces were also examined with a crystal violet assay. The distribution's normality was statistically analyzed with the Kolmogorov-Smirnov test. One-way and two-way analysis of variance with post hoc Tukey tests were used for statistical evaluations (α=.05). RESULTS: Surface roughness values in Groups D and H were significantly higher than in other groups (P<.05). While the highest surface free energy values (except γp) were in Group V, Group C had the highest γp. The lowest biofilm value appeared in Group H. Chitosan exhibited an antibiofilm effect in all groups except Group H, while eugenol was effective in all groups. CONCLUSIONS: The production method affected the susceptibility of occlusal device materials to the adhesion of C. albicans. Eugenol was an effective antibiofilm agent for device materials.


Asunto(s)
Candida albicans , Quitosano , Eugenol/farmacología , Eugenol/uso terapéutico , Quitosano/farmacología , Biopelículas , Propiedades de Superficie , Ensayo de Materiales
2.
Odontology ; 111(4): 942-952, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36973535

RESUMEN

This study evaluated microleakage from class II cavities filled with bulk-fill composite preheated to different temperatures, applied at different thicknesses, and with different polymerization modes. A total of 60 mesio-occlusal cavity were drilled into the extracted human third molars at 2 mm and 4 mm thickness. Preheated bulk-fill composite resin (Viscalor; VOCO, Germany) was applied to the cavities at 68 °C and 37 °C after the adhesive resin was applied, and cured using standard and high-power light-curing modes of a VALO light-curing unit. An incrementally applied microhybrid composite was used as the control. The teeth were subjected to 2000 cycles of heating to 55 °C and cooling to 5 °C with a 30-s hold time. Then, they were immersed in a 50% silver nitrate solution for 24 h and scanned with micro-computed tomography. Scanned data were processed using the CTAn software. Two (2D) and three (3D) dimensional analyses of leached silver nitrate were performed. The data's normality was assessed using the Shapiro-Wilk test before comparisons using a three-way analysis of variance. In both 2D and 3D analysis, bulk-fill composite resin preheated to 68 °C and applied at 2 mm thickness showed less microleakage. In the 3D analysis, restorations applied at 37 °C and 4 mm thickness in high-power mode showed significantly higher values (p < 0.001). Preheated bulk-fill composite resin can be applied at 68 °C and effectively cured at both 2 mm and 4 mm thickness.


Asunto(s)
Caries Dental , Filtración Dental , Humanos , Resinas Compuestas , Microtomografía por Rayos X , Restauración Dental Permanente/métodos , Nitrato de Plata , Ensayo de Materiales
3.
Clin Oral Investig ; 26(8): 5289-5299, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35474553

RESUMEN

OBJECTIVES: The aim of this study is to evaluate the adhesion of Streptococcus mutans on the surface of CAD/CAM materials with various surface treatments. METHODS: Vita Enamic, Lava Ultimate, and Cerasmart materials were used in this study. A total of 90 samples were prepared (n = 10). After various finishing and polishing procedures (non-polished, manual polished, and glazed), surface roughness (SR) measurements, surface free energy (SFE), and elemental and topographic analysis with FIB-SEM/EDX were used to evaluate the samples' surface properties. To improve bacterial adhesion, CAD/CAM materials were covered with sterile artificial saliva containing mucin for pellicle formation and incubated for 1 h at 37 °C. Bacteria were then inoculated into the pellicle-coated specimens, and incubation was performed at 37 °C for 24 h. Bacterial adhesion was determined as × 105 CFU/mL and monitored using FIB-SEM analysis. The Kolmogorov-Smirnov test was used to statistically analyze the normality of the distribution; the groups were then compared using one-way ANOVA and Tukey's test. RESULTS: The SR of the control group was statistically higher in all materials (p < 0.05). There were no statistically significant differences in SR between all materials in the non-polished and manual polished groups (p > 0.05). The Vita Enamic control group exhibited the highest SFE value. The highest S. mutans adhesion was observed in non-polished (p < 0.05). Vita Enamic samples had higher CFU than other groups. CONCLUSIONS: Non-polished surfaces showed higher SR and bacterial adhesion. Polishing processes affected the surface properties and bacterial adhesion. CLINICAL RELEVANCE: Care must be taken in polishing restorations to minimize the risk of bacterial adhesion and recurrent caries. TRIAL REGISTRATION: In this study, the materials used for dental treatments are in vitro evaluated. Due to that, this study is not registered to clinical trials.


Asunto(s)
Adhesión Bacteriana , Pulido Dental , Cerámica , Diseño Asistido por Computadora , Pulido Dental/métodos , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie
4.
J Esthet Restor Dent ; 34(6): 924-932, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35118802

RESUMEN

OBJECTIVES: To determine the color stability and microhardness of three bulk-fill composites with different polymerization characteristics, after immersion in four different solutions. MATERIALS AND METHODS: Color measurements of three bulk fill (Viscalor (VIS), Tetric PowerFill (TPF), Fill Up! (FUP)) and a microhyrid composite resin (G-aenial posterior [GCP]) were performed after polymerization. The specimens were immersed in coffee, cola, red wine and distilled water. Discolorations were recorded after 24 h (T1), 10 days (T2) and 30 days (T3) of immersion. ΔE (CIEDE2000) values were calculated. Vickers microhardness (VHN) was measured from top and bottom surfaces at T0 and T3. Data was analyzed with Two-way ANOVA, One-way ANOVA and Tukey post hoc tests. RESULTS: The highest discoloration was seen in wine and the lowest in distilled water and cola. At T3, there was no difference in distilled water groups, while the statistically highest ΔE00 were obtained in TPF and GCP in coffee, cola and wine. VIS groups had the highest VHN values at T0 and T3 in all solutions. CONCLUSIONS: Samples immersed in coffee and wine showed discoloration beyond clinically acceptable limits. After 30 days, discoloration occurred in all materials immersed in all solutions. At T3, VIS microhardness generally decreased, while TPF did not. CLINICAL SIGNIFICANCE: After 30 days, all bulk-fill composites immersed in distilled water, coffee and wine showed clinically unacceptable ΔE00 .


Asunto(s)
Café , Resinas Compuestas , Color , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie , Agua
5.
Microsc Res Tech ; 84(8): 1783-1793, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33586287

RESUMEN

This study aimed to examine the surface characteristics of low shrinkage composites and adhesion of Streptococcus mutans and Streptococcus mitis to these materials. Control material (glass) and three low shrinkage composites (Charisma Diamond, Kalore GC, Beatiful II LS) were used. After polishing procedure was applied to composite specimens, surface roughness (SR), surface free energy (SFE), and contact angle measurements were performed. Surfaces of composite were analyzed using scanning electron microscope and energy-dispersive X-ray spectroscopy. After pellicle formation with artificial saliva, S. mutans and S. mitis biofilms were incubated in 5% CO2 for 24 h at 37°C and were analyzed using confocal laser scanning microscopy. The lowest SR and highest SFE values were found in the control group. While the contact angle of control was statistically lower than composites, statistically difference was not found between composite groups. S. mutans adhesion of composites was significantly lower than control group, but there was no significant difference between composites. S. mitis adhesion of all groups was statistically similar. SR did not affect the S. mutans and S. mitis adhesion. Less adherence of S. mutans to low shrinkage composites was associated with low SFE and high contact angle values. Even though the highest SR was observed in the Charisma Diamond, no difference was found between the composites in terms of bacterial adhesion.


Asunto(s)
Adhesión Bacteriana , Resinas Compuestas , Biopelículas , Ensayo de Materiales , Streptococcus mutans , Propiedades de Superficie
6.
Odovtos (En línea) ; 24(3)dic. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1406167

RESUMEN

Abstract The purpose of this study was to compare the effect of different disinfection protocols of dentin on bond strength of an MDP-containing universal adhesive. Twelve extracted mandibular third molars were separated horizontally at the mid-coronal of crown to get smooth and sound dentin surfaces using low-speed diamond saw. The teeth were randomly fallen into four groups: chlorhexidine (CHX), ozone, Er,Cr:YSGG laser irradiation (LASER) and no treatment (control). After cavity disinfection application, a universal adhesive (G-Premio Bond) was applied to the surface of dentin according to self-etch mode as instructed by the manufacturer. After incremental built-up of composite resin (Charisma Smart), the specimens were immersed in distilled water at 37°C for 24h. Dentin/composite beams with 1 mm² cross sectional area were produced and micro-tensile bond strength (µTBS) was applied on these beams (n=20). Failure mods were determined under a stereomicroscope at ×40. The resin penetration of samples stained with Rhodamine B fluorochrome dye was examined with a confocal laser scanning microscope. Statistical analysis was performed with SPSS-22. Test results were analyzed using One-way Anova and Tukey HSD Post-Hoc tests (p0.5). All applications of cavity disinfection procedures decreased the µTBS of the resin-dentin interface.


Resumen El propósito de este estudio fue comparar el efecto de diferentes protocolos de desinfección de la dentina sobre la fuerza de unión de un adhesivo universal que contiene MDP. Doce terceros molares mandibulares extraídos se quebraron horizontalmente en la mitad de la corona para obtener superficies de dentina lisas y sólidas utilizando una sierra de diamante de baja velocidad. Los dientes se dividieron aleatoriamente en cuatro grupos: clorhexidina (CHX), ozono, irradiación con láser Er,Cr:YSGG (LASER) y ningún tratamiento (control). Después de la aplicación de la desinfección de la cavidad, se aplicó un adhesivo universal (G-Premio Bond) a la superficie de la dentina según el modo de autograbado indicado por el fabricante. Después de la obturación con resina compuesta (Charisma Smart), las muestras se sumergieron en agua destilada a 37°C durante 24h. Se produjeron porciones de dentina/resina con un área de sección transversal de 1 mm² y se aplicó una fuerza de adhesión microtensile (µTBS) (n=20). Los modos de falla se determinaron bajo un microscopio estereoscópico a ×40. La penetración de la resina de las muestras teñidas con colorante fluorocromo rodamina B se examinó con un microscopio de barrido láser confocal. El análisis estadístico se realizó con SPSS-22. Los resultados de las pruebas se analizaron utilizando las pruebas post-hoc Anova unidireccional y Tukey HSD (p0.5). Todas las aplicaciones de procedimientos de desinfección de cavidades redujeron el µTBS de la interfaz resina-dentina.


Asunto(s)
Humanos , Desinfección , Desinfectantes/uso terapéutico , Boca , Turquía
7.
Odovtos (En línea) ; 24(1)abr. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386582

RESUMEN

Abstract The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. In this study, three bulk-fill composites- SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. When comparing the baseline and the 24- hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.


Resumen El objetivo fue investigar el efecto del precalentamiento de tres resinas Bulk-fill, una resina compuesta convencional sobre la microdureza Vickers y la profundidad de curado de estas resinas. Se utilizaron tres composites Bulk-Fill-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), y una resina compuesta convencional G-ænial POSTERIOR (GP) como grupo de control. Las muestras se obtuvieron a temperatura ambiente (24°C) y a 55°C en modo T2 después de haber sido colocadas en un dispositivo de calentamiento durante 10 minutos. Se dividieron en ocho grupos (n=10) según el tipo de material y el proceso de calentamiento que se utilizó (precalentado y no calentado). Se probaron con un medidor de microdureza Vickers (VHN) en las superficies inferior y superior. Las primeras mediciones se obtuvieron en la línea de base; la segunda se realizó después de que las muestras se almacenaran en agua destilada a 37°C durante 24 horas. La profundidad de curado se calculó utilizando una relación de dureza inferior/ superior de las mediciones. El análisis estadístico se realizó utilizando el SPSS V23 y las pruebas de Shapiro-Wilk. Por último, se utilizó la prueba de Duncan para las comparaciones múltiples (p<0,05). VHN aumentó tras el procedimiento de precalentamiento en las resina Bulk-Fill, disminuyó en los GP. No hubo diferencias entre los valores de VHN de referencia y de 24 horas en SDR y GP. Después de 24 horas, mientras que el VHN de EST aumentó, el VHN de AFX disminuyó. No hubo diferencias entre los ratios de dureza de las muestras de AFX y EST (p<0,001) y los ratios de dureza fueron mayores que los de GP y SDR. Al comparar los valores de referencia y los de 24 horas, el VHN dependió del tipo de materiales. Se obtuvo una profundidad de curado suficiente en todos los grupos con un grosor de 2mm.


Asunto(s)
Resinas Compuestas/análisis , Calentadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA