1.
Magn Reson Med ; 71(4): 1542-53, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23716466

RESUMEN

PURPOSE: Changes in aortic geometry or presence of aortic valve (AoV) disease can result in substantially altered aortic hemodynamics. Dilatation of the ascending aorta or AoV abnormalities can result in an increase in helical flow. METHODS: 4D flow magnetic resonance imaging was used to test the feasibility of quantitative helicity analysis using equidistantly distributed 2D planes along the entire aorta. The evaluation of the method included three parts: (1) the quantification of helicity in 12 healthy subjects, (2) an evaluation of observer variability and test-retest reliability, and (3) the quantification of helical flow in 16 patients with congenitally altered bicuspid AoVs. RESULTS: Helicity quantification in healthy subjects revealed consistent directions of flow rotation along the entire aorta with high clockwise helicity in the aortic arch and an opposite rotation sense in the ascending and descending aorta. The results demonstrated good scan-rescan and inter- and intraobserver agreement of the helicity parameters. Helicity quantification in patients revealed a significant increase in absolute peak relative helicity during systole and a considerably greater heterogeneous distribution of mean helicity in the aorta. CONCLUSION: The method has the potential to serve as a reference distribution for comparisons of helical flow between healthy subjects and patients or between different patient groups.


Asunto(s)
Aorta/patología , Aorta/fisiopatología , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/patología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Velocidad del Flujo Sanguíneo , Técnicas de Imagen Sincronizada Cardíacas/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA