Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Digit Imaging ; 31(2): 159-166, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28948384

RESUMEN

Dual-energy X-ray absorptiometry (DXA) is the most frequently performed examination to assess bone mineral density in clinical practice. Aside from images and graphical displays, many numerical values are part of DXA reports. These values are typically manually entered into the formal report through the electronic medical record or PACS workstation. The process takes time and is prone to errors. Exporting the DXA numerical data via HL7 engine to the electronic medical record was proposed to improve reporting efficiency and accuracy. The output from the DXA unit computer was reconfigured to export the report content via the HL7 interface engine into the electronic medical record. Radiology interpretive reporting was subsequently done directly in the electronic medical record. In the evaluation of errors, 100 preliminary DXA reports before the change and 100 after the change were examined. These reports were analyzed for errors that included decimal change, number transposition, negative number issue, other incorrect number error, and failure to include prior exam for comparison. In addition, report turnaround times were evaluated before and after the changes were made. Reporting time evaluations included 1-year volume prior to change (3915 reports) and 1 month post-change (206 reports). Of 100 DEXA exams before the change, 15 final reports contained 25 numerical errors. After the change, no numerical errors in the reports were identified. Exam end to final report time decreased from 2159 to 625 min on average. Automating data transmittal from the DXA modality for report generation improves accuracy and turnaround time. This approach did not require any third party software, and healthcare information security concerns were negated since we are using our standard workstations. Secondary to the affordability and applicability to the large percentage of the population using electronic medical record systems, this type of automated workflow is recommended.


Asunto(s)
Absorciometría de Fotón/métodos , Densidad Ósea , Registros Electrónicos de Salud , Osteoporosis/diagnóstico por imagen , Humanos , Flujo de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA