Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 128(10): 105001, 2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35333092

RESUMEN

Magnetic measurements during dc helicity injection tokamak startup indicate Alfvénic turbulence in the injected current streams mediates magnetic relaxation and results in macroscopic plasma current drive. Localization of such activity to the injected current streams, a bias voltage dependence to its onset, and higher-order spectral analysis indicate super-Alfvénic electrons excite instabilities that drive the observed turbulence. Measured fluctuation helicity is consistent with an α-dynamo electromotive force driving net current comparable to the macroscopic equilibrium current density. These results imply new constraints for scaling local helicity injection to larger devices.

2.
Phys Rev Lett ; 119(3): 035001, 2017 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-28777627

RESUMEN

Access to and characterization of sustained, toroidally confined plasmas with a very high plasma-to-magnetic pressure ratio (ß_{t}), low internal inductance, high elongation, and nonsolenoidal current drive is a central goal of present tokamak plasma research. Stable access to this desirable parameter space is demonstrated in plasmas with ultralow aspect ratio and high elongation. Local helicity injection provides nonsolenoidal sustainment, low internal inductance, and ion heating. Equilibrium analyses indicate ß_{t} up to ∼100% with a minimum |B| well spanning up to ∼50% of the plasma volume.

3.
Phys Rev Lett ; 116(17): 175001, 2016 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-27176526

RESUMEN

Tokamak experiments at near-unity aspect ratio A≲1.2 offer new insights into the self-organized H-mode plasma confinement regime. In contrast to conventional A∼3 plasmas, the L-H power threshold P_{LH} is ∼15× higher than scaling predictions, and it is insensitive to magnetic topology, consistent with modeling. Edge localized mode (ELM) instabilities shift to lower toroidal mode numbers as A decreases. These ultralow-A operations enable heretofore inaccessible J_{edge}(R,t) measurements through an ELM that show a complex multimodal collapse and the ejection of a current-carrying filament.

4.
Rev Sci Instrum ; 87(11): 11E523, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910356

RESUMEN

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

5.
Rev Sci Instrum ; 87(11): 11E403, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910362

RESUMEN

A novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fast shutter. This ∼103 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot Te(R) for ne > 5 × 1018 m-3.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA