RESUMEN
Fluorescence correlation spectroscopy is a versatile tool for studying fast conformational changes of biomolecules especially when combined with Förster resonance energy transfer (FRET). Despite the many methods available for identifying structural dynamics in FRET experiments, the determination of the forward and backward transition rate constants and thereby also the equilibrium constant is difficult when two intensity levels are involved. Here, we combine intensity correlation analysis with fluorescence lifetime information by including only a subset of photons in the autocorrelation analysis based on their arrival time with respect to the excitation pulse (microtime). By fitting the correlation amplitude as a function of microtime gate, the transition rate constants from two fluorescence-intensity level systems and the corresponding equilibrium constants are obtained. This shrinking-gate fluorescence correlation spectroscopy (sg-FCS) approach is demonstrated using simulations and with a DNA origami-based model system in experiments on immobilized and freely diffusing molecules. We further show that sg-FCS can distinguish photophysics from dynamic intensity changes even if a dark quencher, in this case graphene, is involved. Finally, we unravel the mechanism of a FRET-based membrane charge sensor indicating the broad potential of the method. With sg-FCS, we present an algorithm that does not require prior knowledge and is therefore easily implemented when an autocorrelation analysis is carried out on time-correlated single-photon data.
Asunto(s)
Transferencia Resonante de Energía de Fluorescencia , Fotones , Espectrometría de Fluorescencia/métodos , Transferencia Resonante de Energía de Fluorescencia/métodos , Modelos BiológicosRESUMEN
We introduce p-MINFLUX, a new implementation of the highly photon-efficient single-molecule localization method with a simplified experimental setup and additional fluorescence lifetime information. In contrast to the original MINFLUX implementation, p-MINFLUX uses interleaved laser pulses to deliver the doughnut-shaped excitation foci at a maximum repetition rate. Using both static and dynamic DNA origami model systems, we demonstrate the performance of p-MINFLUX for single-molecule localization nanoscopy and tracking, respectively. p-MINFLUX delivers 1-2 nm localization precision with 2000-1000 photon counts. In addition, p-MINFLUX gives access to the fluorescence lifetime enabling multiplexing and super-resolved lifetime imaging. p-MINFLUX should help to unlock the full potential of innovative single-molecule localization schemes.
Asunto(s)
Nanotecnología , Fotones , ADN , Rayos Láser , Microscopía FluorescenteRESUMEN
Single-molecule localization based super-resolution microscopy has revolutionized optical microscopy and routinely allows for resolving structural details down to a few nanometers. However, there exists a rather large discrepancy between lateral and axial localization accuracy, the latter typically three to five times worse than the former. Here, we use single-molecule metal-induced energy transfer (smMIET) to localize single molecules along the optical axis, and to measure their axial distance with an accuracy of 5 nm. smMIET relies only on fluorescence lifetime measurements and does not require additional complex optical setups.
RESUMEN
3D super-resolution microscopy with nanometric resolution is a key to fully complement ultrastructural techniques with fluorescence imaging. Here, we achieve 3D super-resolution by combining the 2D localization of pMINFLUX with the axial information of graphene energy transfer (GET) and the single-molecule switching by DNA-PAINT. We demonstrate <2 nm localization precision in all 3 dimension with axial precision reaching below 0.3 nm. In 3D DNA-PAINT measurements, structural features, i.e., individual docking strands at distances of 3 nm, are directly resolved on DNA origami structures. pMINFLUX and GET represent a particular synergetic combination for super-resolution imaging near the surface such as for cell adhesion and membrane complexes as the information of each photon is used for both 2D and axial localization information. Furthermore, we introduce local PAINT (L-PAINT), in which DNA-PAINT imager strands are equipped with an additional binding sequence for local upconcentration improving signal-to-background ratio and imaging speed of local clusters. L-PAINT is demonstrated by imaging a triangular structure with 6 nm side lengths within seconds.
RESUMEN
Single-molecule experiments have changed the way we explore the physical world, yet data analysis remains time-consuming and prone to human bias. Here, we introduce Deep-LASI (Deep-Learning Assisted Single-molecule Imaging analysis), a software suite powered by deep neural networks to rapidly analyze single-, two- and three-color single-molecule data, especially from single-molecule Förster Resonance Energy Transfer (smFRET) experiments. Deep-LASI automatically sorts recorded traces, determines FRET correction factors and classifies the state transitions of dynamic traces all in ~20-100 ms per trajectory. We benchmarked Deep-LASI using ground truth simulations as well as experimental data analyzed manually by an expert user and compared the results with a conventional Hidden Markov Model analysis. We illustrate the capabilities of the technique using a highly tunable L-shaped DNA origami structure and use Deep-LASI to perform titrations, analyze protein conformational dynamics and demonstrate its versatility for analyzing both total internal reflection fluorescence microscopy and confocal smFRET data.
Asunto(s)
Aprendizaje Profundo , Imagen Individual de Molécula , Humanos , Imagen Individual de Molécula/métodos , ADN/química , Microscopía , Conformación Proteica , Transferencia Resonante de Energía de Fluorescencia/métodosRESUMEN
A rectangular DNA origami structure is one of the most studied and often used motif for applications in DNA nanotechnology. Here, we present two assays to study structural changes in DNA nanostructures and reveal a reversible rolling-up of the rectangular DNA origami structure induced by bivalent cations such as magnesium or calcium. First, we applied one-color and two-color superresolution DNA-PAINT with protruding strands along the long edges of the DNA origami rectangle. At increasing salt concentration, a single line instead of two lines is observed as a first indicator of rolling-up. Two-color measurements also revealed different conformations with parallel and angled edges. Second, we placed a gold nanoparticle and a dye molecule at different positions on the DNA origami structure. Distance dependent fluorescence quenching by the nanoparticle reports on dynamic transitions as well as it provides evidence that the rolling-up occurs preferentially along the diagonal of the DNA origami rectangle. The results will be helpful to test DNA structural models and the assays presented will be useful to study further structural transitions in DNA nanotechnology.
Asunto(s)
Nanopartículas del Metal , Nanoestructuras , ADN/química , Oro/química , Nanopartículas del Metal/química , Nanoestructuras/química , Nanotecnología/métodos , Conformación de Ácido NucleicoRESUMEN
Graphene exhibits outstanding fluorescence quenching properties that can become useful for biophysics and biosensing applications, but it remains challenging to harness these advantages due to the complex transfer procedure of chemical vapor deposition-grown graphene to glass coverslips and the low yield of usable samples. Here, we screen 10 graphene-on-glass preparation methods and present an optimized protocol. To obtain the required quality for single-molecule and super-resolution imaging on graphene, we introduce a graphene screening method that avoids consuming the investigated sample. We apply DNA origami nanostructures to place fluorescent probes at a defined distance on top of graphene-on-glass coverslips. Subsequent fluorescence lifetime imaging directly reports on the graphene quality, as deviations from the expected fluorescence lifetime indicate imperfections. We compare the DNA origami probes with conventional techniques for graphene characterization, including light microscopy, atomic force microscopy, and Raman spectroscopy. For the latter, we observe a discrepancy between the graphene quality implied by Raman spectra in comparison to the quality probed by fluorescence lifetime quenching measured at the same position. We attribute this discrepancy to the difference in the effective area that is probed by Raman spectroscopy and fluorescence quenching. Moreover, we demonstrate the applicability of already screened and positively evaluated graphene for studying single-molecule conformational dynamics on a second DNA origami structure. Our results constitute the basis for graphene-based biophysics and super-resolution microscopy.
Asunto(s)
Grafito , ADN , Colorantes Fluorescentes , Nanotecnología , Espectrometría RamanRESUMEN
Graphene is considered a game-changing material, especially for its mechanical and electrical properties. This work exploits that graphene is almost transparent but quenches fluorescence in a range up to ≈40 nm. Graphene as a broadband and unbleachable energy-transfer acceptor without labeling, is used to precisely determine the height of molecules with respect to graphene, to visualize the dynamics of DNA nanostructures, and to determine the orientation of Förster-type resonance energy transfer (FRET) pairs. Using DNA origami nanopositioners, biosensing, single-molecule tracking, and DNA PAINT super-resolution with <3 nm z-resolution are demonstrated. The range of examples shows the potential of graphene-on-glass coverslips as a versatile platform for single-molecule biophysics, biosensing, and super-resolution microscopy.
Asunto(s)
Nanotecnología , Grafito , Nanoestructuras , Imagen Individual de MoléculaRESUMEN
Fluorescence resonance energy transfer (FRET) has been instrumental in determining the structure and dynamics of biomolecules but distances above 8 nanometers are not accessible. However, with the advent and rapid development of super-resolution (SR) microscopy, distances between two fluorescent dyes below 20 nanometers can be resolved, which hitherto has been inaccessible for fluorescence microscopy approaches due to the limited resolving power of an optical imaging system that is determined by the fundamental laws of light diffraction (referred to as the diffraction limit). Therefore, the question arises whether SR microscopy can ultimately close the resolution gap between FRET and the diffraction limit and whether SR microscopy can be employed for the structural interrogation of proteins in the sub-20 nm range? Here, we show that the combination of DNA nanotechnology and single-molecule biochemistry allows the first step towards the investigation of the structural organization of a protein via SR microscopy. Limiting factors and possible future directions for the full implementation of SR microscopy as a structural tool are discussed.
Asunto(s)
Transferencia Resonante de Energía de Fluorescencia , Microscopía Fluorescente , Nanotecnología , ADN , Colorantes FluorescentesRESUMEN
In this contribution, we fabricate hybrid constructs based on a natural light-harvesting complex, peridinin-chlorophyll a-protein, coupled to dimer optical antennas self-assembled with the help of the DNA origami technique. This approach enables controlled positioning of individual complexes at the hotspot of the optical antennas based on large, colloidal gold and silver nanoparticles. Our approach allows us to selectively excite the different pigments present in the harvesting complex, reaching a fluorescence enhancement of 500-fold. This work expands the range of self-assembled functional hybrid constructs for harvesting sunlight and can be further developed for other pigment-proteins and proteins.