Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nano Lett ; 20(4): 2585-2593, 2020 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-32092276

RESUMEN

We demonstrated a bioelectronic heart-on-a-chip model for studying the effects of acute hypoxia on cardiac function. A microfluidic channel enabled rapid modulation of medium oxygenation, which mimicked the regimes induced by a temporary coronary occlusion and reversibly activated hypoxia-related transduction pathways in HL-1 cardiac model cells. Extracellular bioelectronics provided continuous readouts demonstrating that hypoxic cells experienced an initial period of tachycardia followed by a reduction in beat rate and eventually arrhythmia. Intracellular bioelectronics consisting of Pt nanopillars temporarily entered the cytosol following electroporation, yielding action potential (AP)-like readouts. We found that APs narrowed during hypoxia, consistent with proposed mechanisms by which oxygen deficits activate ATP-dependent K+ channels that promote membrane repolarization. Significantly, both extra- and intracellular devices could be multiplexed, enabling mapping capabilities unachievable by other electrophysiological tools. Our platform represents a significant advance toward understanding electrophysiological responses to hypoxia and could be applicable to disease modeling and drug development.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas/instrumentación , Corazón/fisiopatología , Hipoxia/fisiopatología , Dispositivos Laboratorio en un Chip , Potenciales de Acción , Animales , Arritmias Cardíacas/fisiopatología , Línea Celular , Fenómenos Electrofisiológicos , Diseño de Equipo , Frecuencia Cardíaca , Humanos , Ratones
2.
ACS Nano ; 18(4): 3775-3782, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38227976

RESUMEN

We report a general approach for the synthesis of single-crystal silicon nanotubes, involving epitaxial deposition of silicon shells on germanium nanowire templates followed by removal of the germanium template by selective wet etching. By exploiting advances in the synthesis of germanium nanowires, we were able to rationally tune the nanotube internal diameters (5-80 nm), wall thicknesses (3-12 nm), and taper angles (0-9°) and additionally demonstrated branched silicon nanotube networks. Field effect transistors fabricated from p-type nanotubes exhibited a strong gate effect, and fluid transport experiments demonstrated that small molecules could be electrophoretically driven through the nanotubes. These results demonstrate the suitability of silicon nanotubes for the design of nanoelectrofluidic devices.

3.
Adv Sci (Weinh) ; 11(36): e2402236, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39054679

RESUMEN

Bioelectronic medicine is emerging as a powerful approach for restoring lost endogenous functions and addressing life-altering maladies such as cardiac disorders. Systems that incorporate both modulation of cellular function and recording capabilities can enhance the utility of these approaches and their customization to the needs of each patient. Here we report an integrated optogenetic and bioelectronic platform for stable and long-term stimulation and monitoring of cardiomyocyte function in vitro. Optical inputs are achieved through the expression of a photoactivatable adenylyl cyclase, that when irradiated with blue light causes a dose-dependent and time-limited increase in the secondary messenger cyclic adenosine monophosphate with subsequent rise in autonomous cardiomyocyte beating rate. Bioelectronic readouts are obtained through a multi-electrode array that measures real-time electrophysiological responses at 32 spatially-distinct locations. Irradiation at 27 µW mm-2 results in a 14% elevation of the beating rate within 20-25 min, which remains stable for at least 2 h. The beating rate can be cycled through "on" and "off" light states, and its magnitude is a monotonic function of irradiation intensity. The integrated platform can be extended to stretchable and flexible substrates, and can open new avenues in bioelectronic medicine, including closed-loop systems for cardiac regulation and intervention, for example, in the context of arrythmias.


Asunto(s)
Miocitos Cardíacos , Optogenética , Miocitos Cardíacos/metabolismo , Optogenética/métodos , Animales , Ratas , Humanos , Células Cultivadas
4.
bioRxiv ; 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38168441

RESUMEN

We report an integrated optogenetic and bioelectronic platform for stable and long-term modulation and monitoring of cardiomyocyte function in vitro. Optogenetic inputs were achieved through expression of a photoactivatable adenylyl cyclase (bPAC), that when activated by blue light caused a dose-dependent and time-limited increase in autonomous cardiomyocyte beat rate. Bioelectronic readouts were achieved through an integrated planar multi-electrode array (MEA) that provided real-time readouts of electrophysiological activity from 32 spatially-distinct locations. Irradiation at 27 µW/mm2 resulted in a ca. 14% increase in beat rate within 20-25 minutes, which remained stable for at least 2 hours. The beating rate could be cycled through repeated "on" and "off' states, and its magnitude was a monotonic function of irradiation intensity. Our integrated platform opens new avenues in bioelectronic medicine, including closed-loop feedback systems, with potential applications for cardiac regulation including arrhythmia diagnosis and intervention.

5.
J Neurosci Methods ; 267: 108-14, 2016 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-27060385

RESUMEN

BACKGROUND: Measuring food intake in rodents is a conceptually simple yet labor-intensive and temporally-imprecise task. Most commonly, food is weighed manually, with an interval of hours or days between measurements. Commercial feeding monitors are excellent, but are costly and require specialized caging and equipment. NEW METHOD: We have developed the Feeding Experimentation Device (FED): a low-cost, open-source, home cage-compatible feeding system. FED utilizes an Arduino microcontroller and open-source software and hardware. FED dispenses a single food pellet into a food well where it is monitored by an infrared beam. When the mouse removes the pellet, FED logs the timestamp to a secure digital (SD) card and dispenses a new pellet into the well. Post-hoc analyses of pellet retrieval timestamps reveal high-resolution details about feeding behavior. RESULTS: FED is capable of accurately measuring food intake, identifying discrete trends during light and dark-cycle feeding. Additionally, we show the utility of FED for measuring increases in feeding resulting from optogenetic stimulation of agouti-related peptide neurons in the arcuate nucleus of the hypothalamus. COMPARISON TO EXISTING METHODS: With a cost of ∼$350 per device, FED is >10× cheaper than commercially available feeding systems. FED is also self-contained, battery powered, and designed to be placed in standard colony rack cages, allowing for monitoring of true home cage feeding behavior. Moreover, FED is highly adaptable and can be synchronized with emerging techniques in neuroscience, such as optogenetics, as we demonstrate here. CONCLUSIONS: FED allows for accurate, precise monitoring of feeding behavior in a home cage setting.


Asunto(s)
Automatización de Laboratorios/instrumentación , Automatización de Laboratorios/métodos , Ingestión de Alimentos , Conducta Alimentaria , Programas Informáticos , Alimentación Animal , Animales , Núcleo Arqueado del Hipotálamo/fisiología , Automatización de Laboratorios/economía , Diseño Asistido por Computadora , Ingestión de Alimentos/fisiología , Suministros de Energía Eléctrica , Diseño de Equipo , Conducta Alimentaria/fisiología , Vivienda para Animales , Masculino , Ratones Endogámicos C57BL , Ratones Transgénicos , Neuronas/fisiología , Optogenética , Fotoperiodo , Impresión Tridimensional , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA