Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 132(15): 155101, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38682996

RESUMEN

The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. We present here elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1-3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T_{e} temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T_{e} confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.

2.
Rev Sci Instrum ; 94(2): 023508, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36859043

RESUMEN

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 1016 cm-3) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 1017 cm-3 to several 1019 cm-3 and electron temperatures from tens of eV to several keV. Here, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 1016 cm-3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

3.
Rev Sci Instrum ; 92(9): 093503, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34598492

RESUMEN

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 µm spatial resolution or 8.9 km/s when fitting with a 150 µm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

4.
Rev Sci Instrum ; 86(7): 073503, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26233379

RESUMEN

We describe a technique by which magnetic field probes are used to triangulate the exact position of breakdown in a high voltage coaxial vacuum gap. An array of three probes is placed near the plane of the gap with each probe at 90° intervals around the outer (anode) electrode. These probes measure the azimuthal component of the magnetic field and are all at the same radial distance from the cylindrical axis. Using the peak magnetic field values measured by each probe, the current carried by the breakdown channel, and Ampères law we can calculate the distance away from each probe that the breakdown occurred. These calculated distances are then used to draw three circles each centered at the centers of the corresponding magnetic probes. The common intersection of these three circles then gives the predicted azimuthal location of the center of the breakdown channel. Test results first gathered on the coaxial gap breakdown device (240 A, 25 kV, 150 ns) at the University of California San Diego and then on COBRA (1 MA, 1 MV, 100 ns) at Cornell University indicate that this technique is relatively accurate and scales between these two devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA