RESUMEN
OBJECTIVES: The aim of this study was to compare the clinical performance of depot medroxyprogesterone acetate (DMPA) in women who received injections every 3 months at the Family Planning Clinic, and those who received every other injection at a health care facility near their place of residence, only returning to the clinic every 6 months. MATERIALS AND METHODS: The medical charts of DMPA users from 2 January 1980 through 31 December 2012 were evaluated for this study. Two cohorts of women were created and compared: those who regularly received DMPA injections every 3 months (3-month group) at the clinic and those who received alternating 3-month injections at a health care facility near their residence house, returning to the clinic every 6 months for an injection (6-month group). In addition, effectiveness rates, reasons for discontinuation, and continuation rates were evaluated. RESULTS: Overall, 2637 women received all injections at 3-month intervals at the clinic, and 1190 women received every other injection at a health care facility near their residence. The women in the 3-month group had higher pregnancy rates and higher discontinuation rates (with the exception of discontinuation due to the loss of libido). CONCLUSION: The women who received alternating injections near their homes were more likely to continue using DMPA as a contraception method and presented lower pregnancy and discontinuation rates (for the majority of reasons), when compared to those women who returned to the clinic every 3 months.
Asunto(s)
Instituciones de Atención Ambulatoria , Anticonceptivos Femeninos/administración & dosificación , Instituciones de Salud , Acetato de Medroxiprogesterona/administración & dosificación , Índice de Embarazo , Viaje , Adulto , Preparaciones de Acción Retardada , Femenino , Humanos , Estimación de Kaplan-Meier , Embarazo , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto JovenRESUMEN
STUDY QUESTION: What is the contribution of the provision, at no cost for users, of long acting reversible contraceptive methods (LARC; copper intrauterine device [IUD], the levonorgestrel-releasing intrauterine system [LNG-IUS], contraceptive implants and depot-medroxyprogesterone [DMPA] injection) towards the disability-adjusted life years (DALY) averted through a Brazilian university-based clinic established over 30 years ago. SUMMARY ANSWER: Over the last 10 years of evaluation, provision of LARC methods and DMPA by the clinic are estimated to have contributed to DALY averted by between 37 and 60 maternal deaths, 315-424 child mortalities, 634-853 combined maternal morbidity and mortality and child mortality, and 1056-1412 unsafe abortions averted. WHAT IS KNOWN ALREADY: LARC methods are associated with a high contraceptive effectiveness when compared with contraceptive methods which need frequent attention; perhaps because LARC methods are independent of individual or couple compliance. However, in general previous studies have evaluated contraceptive methods during clinical studies over a short period of time, or not more than 10 years. Furthermore, information regarding the estimation of the DALY averted is scarce. STUDY DESIGN, SIZE AND DURATION: We reviewed 50 004 medical charts from women who consulted for the first time looking for a contraceptive method over the period from 2 January 1980 through 31 December 2012. PARTICIPANTS/MATERIALS, SETTING, METHODS: Women who consulted at the Department of Obstetrics and Gynaecology, University of Campinas, Brazil were new users and users switching contraceptive, including the copper IUD (n = 13 826), the LNG-IUS (n = 1525), implants (n = 277) and DMPA (n = 9387). Estimation of the DALY averted included maternal morbidity and mortality, child mortality and unsafe abortions averted. MAIN RESULTS AND THE ROLE OF CHANCE: We obtained 29 416 contraceptive segments of use including 25 009 contraceptive segments of use from 20 821 new users or switchers to any LARC method or DMPA with at least 1 year of follow-up. The mean (± SD) age of the women at first consultation ranged from 25.3 ± 5.7 (range 12-47) years in the 1980s, to 31.9 ± 7.4 (range 16-50) years in 2010-2011. The most common contraceptive chosen at the first consultation was copper IUD (48.3, 74.5 and 64.7% in the 1980s, 1990s and 2000s, respectively). For an evaluation over 20 years, the cumulative pregnancy rates (SEM) were 0.4 (0.2), 2.8 (2.1), 4.0 (0.4) and 1.3 (0.4) for the LNG-IUS, the implants, copper IUD and DMPA, respectively and cumulative continuation rates (SEM) were 15.1 (3.7), 3.9 (1.4), 14.1 (0.6) and 7.3 (1.7) for the LNG-IUS, implants, copper IUD and DMPA, respectively (P < 0.001). Over the last 10 years of evaluation, the estimation of the contribution of the clinic through the provision of LARC methods and DMPA to DALY averted was 37-60 maternal deaths; between 315 and 424 child mortalities; combined maternal morbidity and mortality and child mortality of between 634 and 853, and 1056-1412 unsafe abortions averted. LIMITATIONS, REASONS FOR CAUTION: The main limitations are the number of women who never returned to the clinic (overall 14% among the four methods under evaluation); consequently the pregnancy rate could be different. Other limitations include the analysis of two kinds of copper IUD and two kinds of contraceptive implants as the same IUD or implant, and the low number of users of implants. In addition, the DALY calculation relies on a number of estimates, which may vary in different parts of the world. WIDER IMPLICATIONS OF THE FINDINGS: LARC methods and DMPA are highly effective and women who were well-counselled used these methods for a long time. The benefit of averting maternal morbidity and mortality, child mortality, and unsafe abortions is an example to health policy makers to implement more family planning programmes and to offer contraceptive methods, mainly LARC and DMPA, at no cost or at affordable cost for the underprivileged population. STUDY FUNDING/COMPETING INTERESTS: This study received partial financial support from the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), grant # 2012/12810-4 and from the National Research Council (CNPq), grant #573747/2008-3. B.F.B., M.P.G., and V.M.C. were fellows from the scientific initiation programme from FAPESP. Since the year 2001, all the TCu380A IUD were donated by Injeflex, São Paulo, Brazil, and from the year 2006 all the LNG-IUS were donated by the International Contraceptive Access Foundation (ICA), Turku, Finland. Both donations are as unrestricted grants. The authors declare that there are no conflicts of interest associated with this study.
Asunto(s)
Anticoncepción/métodos , Anticonceptivos Femeninos/uso terapéutico , Años de Vida Ajustados por Calidad de Vida , Brasil , Femenino , Humanos , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Levonorgestrel/uso terapéutico , Medroxiprogesterona/uso terapéutico , Embarazo , Embarazo no Planeado , Estudios Retrospectivos , Factores de TiempoRESUMEN
OBJECTIVES: Weight gain is a concern with the contraceptive depot-medroxyprogesterone acetate (DMPA); however, this issue remains controversial. The objective of this study was to compare body weight (BW) and body composition (BC) in DMPA and copper intrauterine device (IUD) users at baseline and after one year of use. STUDY DESIGN: We enrolled new DMPA users and age and weight matched new IUD users into this prospective study. Weight and height were measured, BC (fat and lean mass) was evaluated using dual-energy X-ray absorptiometry, and physical activity was assessed at baseline and at 12 months. Student's paired t test and the Wilcoxon paired test for matched samples were used. RESULTS: Ninety-seven women were enrolled for the study; 26 matched pairs continued using the initial method for at least one year, and completed the baseline and 12 month assessments. An increase of 1.9 kg occurred in BW (p=.02) in DMPA users at 12 months of use, resulting from an increase in fat mass of 1.6 kg (p=.03). Weight remained stable in IUD users; however, there was an increase in lean mass at 12 months of use (p=.001). The number of women practicing physical activity increased in this group. There was a significant difference between the groups regarding the variation in the percentage of central fat (p=.04). CONCLUSION: Weight gain in the DMPA group after the first year of use resulted from an increase in fat mass. Weight remained stable in the IUD group; however, an increase in lean mass and a reduction in localized abdominal fat mass occurred, possibly because more users were practicing physical activity. IMPLICATIONS STATEMENT: There was a greater increase in body weight in DMPA users compared to TCu380A IUD users in the first year of use of the contraceptive method. Furthermore, the weight increase in users of DMPA occurred principally as the result of an increase in fat mass. Physical activity probably could increase the lean mass in the users of TCu380A IUD.