Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 492
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Osteoporos Int ; 32(8): 1639-1649, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33566138

RESUMEN

Millions of CT scans are performed annually and could be also used to opportunistically assess musculoskeletal health; however, it is unknown how well this secondary assessment relates to osteoporotic fracture. This study demonstrates that opportunistic CT screening is a promising tool to predict individuals with previous osteoporotic fracture. INTRODUCTION: Opportunistic computed tomography (oCT) screening for osteoporosis and fracture risk determination complements current dual X-ray absorptiometry (DXA) diagnosis. This study determined major osteoporotic fracture prediction by oCT at the spine and hip from abdominal CT scans. METHODS: Initial 1158 clinical abdominal CT scans were identified from administrative databases and were the basis to generate a cohort of 490 men and women with suitable abdominal CT scans. Participant CT scans met the following criteria: over 50 years of age, the scan had no image artifacts, and the field-of-view included the L4 vertebra and proximal femur. A total of 123 participants were identified as having previously suffered a fracture within 5 years of CT scan date. Fracture cause was identified from clinical data and used to create a low-energy fracture sub-cohort. At each skeletal site, bone mineral density (BMD) and finite element (FE)-estimated bone strength were determined. Logistic regression predicted fracture and receiver-operator characteristic curves analyzed prediction capabilities. RESULTS: In participants with a fracture, low-energy fractures occurred in 88% of women and 79% of men. Fracture prediction by combining both BMD and FE-estimated bone strength was not statistically different than using either BMD or FE-estimated bone strength alone. Predicting low-energy fractures in women determined the greatest AUC of 0.710 by using both BMD and FE-estimated bone strength. CONCLUSIONS: oCT screening using abdominal CT scans is effective at predicting individuals with previous fracture at major osteoporotic sites and offers a promising screening tool for skeletal health assessment.


Asunto(s)
Osteoporosis , Fracturas Osteoporóticas , Absorciometría de Fotón , Densidad Ósea , Femenino , Humanos , Masculino , Osteoporosis/complicaciones , Osteoporosis/diagnóstico por imagen , Osteoporosis/epidemiología , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/epidemiología , Fracturas Osteoporóticas/etiología , Tomografía Computarizada por Rayos X
2.
Osteoporos Int ; 32(9): 1849-1857, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33624139

RESUMEN

We developed and validated a finite element (FE) approach for longitudinal high-resolution peripheral quantitative computed tomography (HR-pQCT) studies using 3D image registration to account for misalignment between images. This reduced variability in longitudinal FE estimates and improved our ability to measure in vivo changes in HR-pQCT studies of bone strength. INTRODUCTION: We developed and validated a finite element (FE) approach for longitudinal high-resolution peripheral quantitative computed tomography (HR-pQCT) studies using 3D rigid-body registration (3DR) to maximize reproducibility by accounting for misalignment between images. METHODS: In our proposed approach, we used the full common bone volume defined by 3DR to estimate standard FE parameters. Using standard HR-pQCT imaging protocols, we validated the 3DR approach with ex vivo samples of the distal radius (n = 10, four repeat scans) by assessing whether 3DR can reduce measurement variability from repositioning error. We used in vivo data (n = 40, five longitudinal scans) to assess the sensitivity of 3DR to detect changes in bone strength at the distal radius by the standard deviation of the rate of change (σ), where the ideal value of σ is minimized to define true change. FE estimates by 3DR were compared to estimates by no registration (NR) and slice-matching (SM). RESULTS: Group-wise comparisons of ex vivo variation (CVRMS, %) found that FE measurement precision was improved by SM (CVRMS < 0.80%) and 3DR (CVRMS < 0.62%) compared to NR (CVRMS~2%), and 3DR was advantageous as repositioning error increased. Longitudinal in vivo reproducibility was minimized by 3DR for failure load estimates (σ = 0.008 kN/month). CONCLUSION: Although 3D registration cannot negate motion artifacts, it plays an important role in detecting and reducing variability in FE estimates for longitudinal HR-pQCT data and is well suited for estimating effects of interventions in in vivo longitudinal studies of bone strength.


Asunto(s)
Huesos , Radio (Anatomía) , Análisis de Elementos Finitos , Humanos , Radio (Anatomía)/diagnóstico por imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
3.
Scand J Rheumatol ; 50(6): 417-426, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33775211

RESUMEN

Objectives: Previous studies of high-resolution peripheral quantitative computed tomography (HR-pQCT) imaging of hand joints in patients with rheumatoid arthritis (RA) have suggested that erosion healing may occur. Our objective was to examine changes in erosion volume, joint space width (JSW), bone mineral density (BMD), and bone remodelling, and their association with clinical outcomes and measures of patient hand function.Method: We examined 48 patients who achieved a good response to a newly initiated biologic therapy. HR-pQCT images of the dominant hands' second and third metacarpophalangeal joints were obtained 3 and 12 months after therapy initiation. Bone erosion volume, JSW, BMD, and bone remodelling were quantified from HR-pQCT images, with improvement, no change (unchanged), or progression in these measures determined by least significant change. Disease activity and hand function measures were collected.Results: There were no significant group changes in HR-pQCT outcomes over the 9 month period. Twenty-two patients had total erosion volumes that remained unchanged, nine showed improvement, and two progressed. The majority of JSW and BMD measures remained unchanged. There was a significant association between the baseline Health Assessment Questionnaire score and the change in minimum JSW, but no other significant associations between HR-pQCT outcomes and function were observed.Conclusions: The vast majority of patients maintained unchanged JSW and BMD over the course of follow-up. Significant improvements in total erosion volume occurred in 27% of patients, suggesting that biologic therapies may lead to erosion healing in some patients, although this did not have an impact on self-reported and demonstrated hand function.


Asunto(s)
Antirreumáticos , Artritis Reumatoide , Productos Biológicos , Terapia Biológica , Antirreumáticos/farmacología , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/tratamiento farmacológico , Productos Biológicos/farmacología , Densidad Ósea/efectos de los fármacos , Densidad Ósea/fisiología , Humanos , Articulación Metacarpofalángica/efectos de los fármacos , Articulación Metacarpofalángica/fisiología , Resultado del Tratamiento
4.
Osteoporos Int ; 31(3): 567-576, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31784787

RESUMEN

Manual correction of automatically generated contours for high-resolution peripheral quantitative computed tomography can be time consuming and introduces precision error. However, bias related to the automated protocol is unknown. This study provides insight into error bias that is present when using uncorrected contours and inter-operator precision error based on operator training. INTRODUCTION: High-resolution peripheral quantitative computed tomography workflow includes manually correcting contours generated by the manufacturer's automated protocol. There is interest in minimizing corrections to save time and reduce precision error; however, bias related to the automated protocol is unknown. This study quantifies error bias when contours are uncorrected and identifies the impact of operator training on bias and precision error. METHODS: Forty-five radii and tibiae scans across a representative range of bone density were analyzed using the automated and manually corrected contours of three operators, with training ranging from beginner to expert, and compared with a "ground truth" to estimate bias. Inter-operator precision was measured across operators. RESULTS: The tibia had greater error bias than the radius when contours were uncorrected, with compartmental bone mineral densities and cortical microarchitecture having greatest biases, which could have significant implications for interpretation of studies using this skeletal site. Bias and precision error were greatest when contours were corrected by the beginner operator; however, when this operator was removed, bias was no longer present and inter-operator precision was between 0.01 and 3.74% for all parameters except cortical porosity. CONCLUSION: These findings establish the need for manual correction and provide guidance on operator training needed to maximize workflow efficiency.


Asunto(s)
Huesos , Radio (Anatomía) , Sesgo , Densidad Ósea , Humanos , Radio (Anatomía)/diagnóstico por imagen , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Flujo de Trabajo
5.
Osteoporos Int ; 31(10): 1995-2005, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32430614

RESUMEN

Longitudinal studies of bone using high-resolution medical imaging may result in non-physiological measurements of longitudinal changes. In this study, we determined that three-dimensional image processing techniques best capture realistic longitudinal changes in bone density and should therefore be used with high-resolution imaging when studying bone changes over time. INTRODUCTION: The purpose of this study was to determine which longitudinal analysis technique (no registration (NR), slice-match (SM) registration, or three-dimensional registration (3DR)) produced the most realistic longitudinal changes in a 3-year study of bone density and structure using high-resolution peripheral quantitative computed tomography (HR-pQCT). METHODS: We assessed HR-pQCT scans of the distal radius and tibia for men and women (N = 40) aged 55-70 years at baseline and 6, 12, 24, and 36 months. To evaluate which longitudinal analysis technique (NR, SM, or 3DR) best captured physiologically reasonable 3-year changes, we calculated the standard deviation of the absolute rate of change in each bone parameter. The data were compared between longitudinal analysis techniques using repeated measures ANOVA and post hoc analysis. RESULTS: As expected, both SM and 3DR better captured physiological longitudinal changes than NR. At the tibia, there were no differences between SM and 3DR; however, at the radius where precision was lower, 3DR produced better results for total bone mineral density. CONCLUSIONS: At least SM or 3DR should be implemented in longitudinal studies using HR-pQCT. 3DR is preferable, particularly at the radius, to ensure that physiological changes in bone density are observed.


Asunto(s)
Densidad Ósea , Radio (Anatomía) , Anciano , Huesos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radio (Anatomía)/diagnóstico por imagen , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X
6.
Osteoporos Int ; 31(11): 2141-2150, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32556518

RESUMEN

Although high-dose vitamin D supplementation is common, effects on arterial calcification remain unexplored. Tibial artery calcification was identified and quantified over 3 years in participants randomized to 400, 4000, or 10,000 IU vitamin D3 daily. High-dose vitamin D supplementation did not affect the development or progression of arterial calcification. INTRODUCTION: To determine whether vitamin D supplementation has a dose-dependent effect on development and progression of arterial calcification. METHODS: This was a secondary analysis of the Calgary Vitamin D Study, a 3-year, double-blind, randomized controlled trial conducted at a single-center in Calgary, Canada. Participants were community-dwelling adults aged 55-70 years with serum 25-hydroxyvitamin D 30-125 nmol/L. Participants were randomized 1:1:1 to receive vitamin D3 400, 4000, or 10,000 IU/day for 3 years. Tibial artery calcification was identified and quantified (in milligrams of hydroxyapatite, mgHA) using high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and 6, 12, 24, and 36 months. Changes in calcification over time and treatment group interaction were evaluated using a constrained linear mixed effects model. RESULTS: Of 311 randomized participants, 302 (400: 105, 4000: 96, 10,000: 101) were eligible for analysis of arterial calcification (54% male, mean (SD) age 62 (4) years, mean (SD) 25-hydroxyvitamin D 78.9 (19.9) nmol/L). At baseline, 85 (28%) had tibial artery calcification, and mean (95% CI) calcification quantity was 2.8 mgHA (95% CI 1.7-3.9). In these 85 participants, calcification quantity increased linearly by 0.020 mgHA/month (95% CI 0.012-0.029) throughout the study, with no evidence of a treatment-group effect (p = 0.645 for interaction). No participants developed new arterial calcifications during the study. CONCLUSIONS: In this population of community-dwelling adults who were vitamin D replete at baseline, supplementation with vitamin D 400, 4000, or 10,000 IU/day did not have differential effects on the development or progression of arterial calcification over 3 years. TRIAL REGISTRATION: clinicaltrials.gov (NCT01900860).


Asunto(s)
Calcinosis , Deficiencia de Vitamina D , Vitamina D , Vitaminas , Adulto , Anciano , Calcinosis/inducido químicamente , Canadá , Colecalciferol , Suplementos Dietéticos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vitamina D/efectos adversos , Vitamina D/uso terapéutico , Deficiencia de Vitamina D/complicaciones , Deficiencia de Vitamina D/tratamiento farmacológico , Vitaminas/efectos adversos , Vitaminas/uso terapéutico
7.
Osteoporos Int ; 31(9): 1607-1627, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32458029

RESUMEN

INTRODUCTION: The application of high-resolution peripheral quantitative computed tomography (HR-pQCT) to assess bone microarchitecture has grown rapidly since its introduction in 2005. As the use of HR-pQCT for clinical research continues to grow, there is an urgent need to form a consensus on imaging and analysis methodologies so that studies can be appropriately compared. In addition, with the recent introduction of the second-generation HrpQCT, which differs from the first-generation HR-pQCT in scan region, resolution, and morphological measurement techniques, there is a need for guidelines on appropriate reporting of results and considerations as the field adopts newer systems. METHODS: A joint working group between the International Osteoporosis Foundation, American Society of Bone and Mineral Research, and European Calcified Tissue Society convened in person and by teleconference over several years to produce the guidelines and recommendations presented in this document. RESULTS: An overview and discussion is provided for (1) standardized protocol for imaging distal radius and tibia sites using HR-pQCT, with the importance of quality control and operator training discussed; (2) standardized terminology and recommendations on reporting results; (3) factors influencing accuracy and precision error, with considerations for longitudinal and multi-center study designs; and finally (4) comparison between scanner generations and other high-resolution CT systems. CONCLUSION: This article addresses the need for standardization of HR-pQCT imaging techniques and terminology, provides guidance on interpretation and reporting of results, and discusses unresolved issues in the field.


Asunto(s)
Densidad Ósea , Osteoporosis , Humanos , Osteoporosis/diagnóstico por imagen , Radio (Anatomía)/diagnóstico por imagen , Tibia , Tomografía Computarizada por Rayos X
8.
Phys Rev Lett ; 124(16): 161802, 2020 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-32383902

RESUMEN

Electron antineutrino appearance is measured by the T2K experiment in an accelerator-produced antineutrino beam, using additional neutrino beam operation to constrain parameters of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix. T2K observes 15 candidate electron antineutrino events with a background expectation of 9.3 events. Including information from the kinematic distribution of observed events, the hypothesis of no electron antineutrino appearance is disfavored with a significance of 2.40σ and no discrepancy between data and PMNS predictions is found. A complementary analysis that introduces an additional free parameter which allows non-PMNS values of electron neutrino and antineutrino appearance also finds no discrepancy between data and PMNS predictions.

9.
J Viral Hepat ; 25(8): 969-975, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29577495

RESUMEN

Multiple direct-acting antiviral (DAA)-based regimens are now available for all hepatitis C virus (HCV) genotypes (GTs). Because HCV GT 4, 5 and 6 are less common in the United States (US) and worldwide, relatively small numbers of participants with these GTs were evaluated in individual clinical trials. To provide a comprehensive description of subtype diversity and treatment outcomes in clinical trials for these less common GTs, we analysed data from 744 participants with HCV GT4 (n = 573), GT5 (n = 81), or GT6 (n = 90) across 18 clinical trials of DAA regimens. These data are from US New Drug Applications submitted between 2014 and 2017, and our analyses included only approved regimens. Excluding unresolved or mixed subtypes, the distribution of reported GT4 subtypes was 49% 4a, 31% 4d and 16% for one of 14 other subtypes. The distribution of GT6 subtypes was 39% 6a, 27% 6e, 8% 6 L and 23% for one of 11 other subtypes. Across approved regimens, sustained virologic response rates 12 weeks post-treatment (SVR12) for GT 4, 5 and 6 ranged from 91% to 100%, 93% to 97% and 96% to 100%, respectively. SVR12 by GT4 subtype ranged from 96% to 100% for 4a and 81% to 100% for 4d. Virologic failures occurred in GT 4a, 4b, 4d and 4r. For GT6, SVR12 was 100% for all subtypes except 6 L, for which 1 of 7 participants experienced virologic failure. To our knowledge, this is the largest compilation of HCV GT 4, 5 or 6 clinical trial data. These analyses may be useful for clinicians treating HCV GT 4, 5 or 6.


Asunto(s)
Antivirales/administración & dosificación , Genotipo , Hepacivirus/clasificación , Hepacivirus/genética , Hepatitis C Crónica/tratamiento farmacológico , Hepatitis C Crónica/virología , Respuesta Virológica Sostenida , Ensayos Clínicos como Asunto , Hepacivirus/aislamiento & purificación , Humanos , Resultado del Tratamiento , Estados Unidos
10.
Osteoarthritis Cartilage ; 26(7): 929-939, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29678623

RESUMEN

OBJECTIVE: Anterior cruciate ligament (ACL) tears increase early onset osteoarthritis (OA) risk leading to cartilage and bone degradation. While the contribution of bone in OA development is unclear, evidence suggests that bone changes accompany cartilage degradation. This study aims to assess if regions with differences in subchondral bone plate thickness have differences in cartilage thickness when comparing ACL reconstructed (ACLR) knees of women ≥5 years post-injury to contralateral and controls with uninjured knees. DESIGN: Magnetic resonance imaging (MRI) assessed cartilage and high resolution peripheral quantitative computed tomography (HR-pQCT) assessed subchondral bone in both knees. Multimodal 3D image registration aligned anatomy. Maps of the spatial distribution of thickness on the articular surfaces were generated to compare women with ACL reconstructions to contralateral and controls with uninjured knees. RESULTS: ACLR knees had a thicker subchondral bone plate in the posterior and central lateral femur compared to contralateral knees (10.4% and 4.2% thicker, P = 0.032 and 0.032, W = 108 and 107, respectively) and in the posterior lateral femur compared to control knees (17.1% thicker, P = 0.014, W = 177). Cartilage differences were not detected (P > 0.05) in these regions. CONCLUSIONS: This study demonstrates that subchondral bone plate thickness differences are prominent following knee injury, as measured by HR-pQCT, but no statistically significant differences in cartilage morphology, measured by MRI, were found between ACLR knees compared to contralateral and control knees. These data provide novel insight into post-traumatic knee injuries that may be signs of early OA pathogenesis.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Factores de Edad , Lesiones del Ligamento Cruzado Anterior/complicaciones , Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Estudios de Casos y Controles , Femenino , Placa de Crecimiento/diagnóstico por imagen , Placa de Crecimiento/patología , Humanos , Interpretación de Imagen Asistida por Computador , Pronóstico , Valores de Referencia , Medición de Riesgo , Factores de Tiempo
11.
Opt Express ; 26(13): 17608-17623, 2018 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-30119572

RESUMEN

Hafnium oxide thin films with varying oxygen content were investigated with the goal of finding the optical signature of oxygen vacancies in the film structure. It was found that a reduction of oxygen content in the film leads to changes in both, structural and optical characteristics. Optical absorption spectroscopy, using nanoKelvin calorimetry, revealed an enhanced absorption in the near-ultraviolet (near-UV) and visible wavelength ranges for films with reduced oxygen content, which was attributed to mid-gap electronic states of oxygen vacancies. Absorption in the near-infrared was found to originate from structural defects other than oxygen vacancy. Luminescence generated by continuous-wave 355-nm laser excitation in e-beam films showed significant changes in the spectral profile with oxygen reduction and new band formation linked to oxygen vacancies. The luminescence from oxygen-vacancy states was found to have microsecond-scale lifetimes when compared with nanosecond-scale lifetimes of luminescence attributed to other structural film defects. Laser-damage testing using ultraviolet nanosecond and infrared femtosecond pulses showed a reduction of the damage threshold with increasing number of oxygen vacancies in hafnium oxide films.

12.
Opt Lett ; 43(18): 4538-4541, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-30211910

RESUMEN

HfO2/SiO2 bilayer coatings and multilayer high-reflection coatings without and with a modified co-evaporated interface (MCEI) have been prepared. An MCEI is designed to be evaporated at an oxygen-deficient environment to achieve higher absorption than the conventional discrete interface. Capacitance-voltage measurements and absorption measurements demonstrate that an MCEI increases the trap density and leads to higher absorption. The laser-induced damage threshold and nano-indenter test results indicate that the MCEI multilayer coating exhibits better laser resistance and mechanical property, despite the larger absorption. The experimental results suggest that adhesive force between layers plays a more important role in nanosecond laser damage resistance than interface absorption.

13.
Phys Rev Lett ; 121(17): 171802, 2018 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-30411920

RESUMEN

The T2K experiment measures muon neutrino disappearance and electron neutrino appearance in accelerator-produced neutrino and antineutrino beams. With an exposure of 14.7(7.6)×10^{20} protons on target in the neutrino (antineutrino) mode, 89 ν_{e} candidates and seven anti-ν_{e} candidates are observed, while 67.5 and 9.0 are expected for δ_{CP}=0 and normal mass ordering. The obtained 2σ confidence interval for the CP-violating phase, δ_{CP}, does not include the CP-conserving cases (δ_{CP}=0, π). The best-fit values of other parameters are sin^{2}θ_{23}=0.526_{-0.036}^{+0.032} and Δm_{32}^{2}=2.463_{-0.070}^{+0.071}×10^{-3} eV^{2}/c^{4}.

14.
Epidemiol Infect ; 146(6): 747-756, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29560838

RESUMEN

Commercial point-of-care (POC) diagnostic tests for Group A Streptococcus, Streptococcus pneumoniae, and influenza virus have large potential diagnostic and financial impact. Many published reports on test performance, often funded by diagnostics companies, are prone to bias. The Standards for Reporting of Diagnostic Accuracy (STARD 2015) are a protocol to encourage accurate, transparent reporting. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool evaluates risk of bias and transportability of results. We used these tools to evaluate diagnostic test accuracy studies of POC studies for three respiratory pathogens. For the 96 studies analysed, compliance was <25% for 14/34 STARD 2015 standards, and 3/7 QUADAS-2 domains showed a high risk of bias. All reports lacked reporting of at least one criterion. These biases should be considered in the interpretation of study results.


Asunto(s)
Sesgo , Pruebas Diagnósticas de Rutina/métodos , Notificación de Enfermedades/normas , Gripe Humana/diagnóstico , Neumonía Neumocócica/diagnóstico , Sistemas de Atención de Punto , Infecciones Estreptocócicas/diagnóstico , Humanos , Infecciones del Sistema Respiratorio/diagnóstico , Medición de Riesgo
15.
BMC Med Imaging ; 18(1): 13, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29764383

RESUMEN

BACKGROUND: We developed a semi-automated algorithm that detects cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT), and extended it with trabecular void volume measurement. In this study we tested the reproducibility of the algorithm using scan/re-scan data. METHODS: Second and third metacarpophalangeal joints of 21 subjects (mean age 49 (SD 11) years, 17 early rheumatoid arthritis and 4 undifferentiated arthritis, all diagnosed < 1 year ago) were imaged twice by HR-pQCT on the same day with repositioning between scans. The images were analyzed twice by one operator (OP1) and once by an additional operator (OP2), who independently corrected the bone contours when necessary. The number, surface and volume of interruptions per joint were obtained. Intra- and inter-operator reliability and intra-operator reproducibility were determined by intra-class correlation coefficients (ICC). Intra-operator reproducibility errors were determined as the least significant change (LSCSD). RESULTS: Per joint, the mean number of interruptions was 3.1 (SD 3.6), mean interruption surface 4.2 (SD 7.2) mm2, and mean interruption volume 3.5 (SD 10.6) mm3 for OP1. Intra- and inter-operator reliability was excellent for the cortical interruption parameters (ICC ≥0.91), except good for the inter-operator reliability of the interruption surface (ICC = 0.70). The LSCSD per joint was 4.2 for the number of interruptions, 5.8 mm2 for interruption surface, and 3.2 mm3 for interruption volume. CONCLUSIONS: The algorithm was highly reproducible in the detection of cortical interruptions and their volume. Based on the LSC findings, the potential value of this algorithm for monitoring structural damage in the joints in early arthritis patients needs to be tested in clinical studies.


Asunto(s)
Artritis/diagnóstico por imagen , Articulación Metacarpofalángica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Algoritmos , Automatización , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
16.
Ann Oncol ; 28(5): 1130-1136, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28327969

RESUMEN

BACKGROUND: Programmed death 1 (PD1) inhibitors are now a foundation of medical management of metastatic melanoma. This study sought to determine whether circulating tumour DNA (ctDNA) provides useful early response and prognostic information. PATIENTS AND METHODS: We evaluated the relationship between pre-treatment and early on treatment ctDNA and outcome in melanoma patients treated with PD1 inhibitors alone or in combination with ipilimumab. RESULTS: ctDNA was detected in 40/76 patients (53%) at baseline, and correlated with stage, LDH levels, disease volume and ECOG performance. RECIST response was 72% (26/36) in group A (undetectable ctDNA at baseline), 77% (17/22) in group B (elevated ctDNA at baseline but undetectable within 12 weeks of therapy) and 6% (1/18) in group C (elevated ctDNA at baseline and remained elevated during treatment). The median PFS was not reached in groups A and B and was 2.7 months for group C [hazard ratio (HR) 0.09; P < 0.001 for group A versus C, and 0.16; P < 0.001 for group B versus C]. The median OS was not reached for groups A and B and was 9.2 months for group C (HR 0.02; P < 0.001 for group A versus C and 0.14; P < 0.001 for group B versus C). The poor outcome measures associated with group C remained significant in multivariate analysis adjusted for LDH, performance status, tumour stage and disease volume. The predictive value for ctDNA for response was confirmed in a separate validation cohort (n = 29, P < 0.01). CONCLUSION: Longitudinal assessment of ctDNA in metastatic melanoma patients receiving treatment with PD1 inhibitors is an accurate predictor of tumour response, PFS and OS. Patients who had a persistently elevated ctDNA on therapy had a poor prognosis, and this may guide combination and sequencing of subsequent therapies.


Asunto(s)
Biomarcadores de Tumor/sangre , ADN Tumoral Circulante/sangre , Melanoma/tratamiento farmacológico , Receptor de Muerte Celular Programada 1/inmunología , Anciano , Anticuerpos Antiidiotipos/administración & dosificación , Anticuerpos Antiidiotipos/inmunología , Supervivencia sin Enfermedad , Femenino , Humanos , Ipilimumab/administración & dosificación , Masculino , Melanoma/sangre , Melanoma/patología , Persona de Mediana Edad , Metástasis de la Neoplasia , Estadificación de Neoplasias , Neoplasias Primarias Secundarias/sangre , Neoplasias Primarias Secundarias/tratamiento farmacológico , Pronóstico , Receptor de Muerte Celular Programada 1/antagonistas & inhibidores
17.
J Anat ; 230(3): 435-443, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27921302

RESUMEN

The pectoral girdle is a complex structure which varies in its morphology between species. A major component in birds is the furcula, which can be considered equivalent to a fusion of the paired clavicles found in many mammals, and the single interclavicle found in many reptiles. These elements are a remnant of the dermal skeleton and the only intramembranous bones in the trunk. Postnatally, the furcula plays important mechanical roles by stabilising the shoulder joint and acting as a mechanical spring during flight. In line with its mechanical role, previous studies indicate that, unlike many other intramembranous bones, furcula growth during development can be influenced by mechanical stimuli. This study investigated the response of individual aspects of furcula growth to both embryo immobilisation and hypermotility in the embryonic chicken. The impact of altered incubation temperature, which influences embryo motility, on crocodilian interclavicle development was also explored. We employed whole-mount bone and cartilage staining and 3D imaging by microCT to quantify the impact of rigid paralysis, flaccid paralysis and hypermobility on furcula growth in the chicken, and 3D microCT imaging to quantify the impact of reduced temperature (32-28 °C) and motility on interclavicle growth in the crocodile. This revealed that the growth rates of the clavicular and interclavicular components of the furcula differ during normal development. Total furcula area was reduced by total unloading produced by flaccid paralysis, but not by rigid paralysis which maintains static loading of embryonic bones. This suggests that dynamic loading, which is required for postnatal bone adaptation, is not a requirement for prenatal furcula growth. Embryo hypermotility also had no impact on furcula area or arm length. Furcula 3D shape did, however, differ between groups; this was marked in the interclavicular component of the furcula, the hypocleideum. Hypocleideum length was reduced by both methods of immobilisation, and interclavicle area was reduced in crocodile embryos incubated at 28 °C, which are less motile than embryos incubated at 32 °C. These data suggest that the clavicular and interclavicle components of the avian furcula respond differently to alterations in embryo movement, with the interclavicle requiring both the static and dynamic components of movement-related loading for normal growth, while static loading preserved most aspects of clavicle growth. Our data suggest that embryo movement, and the mechanical loading this produces, is important in shaping these structures during development to suit their postnatal mechanical roles.


Asunto(s)
Caimanes y Cocodrilos/embriología , Desarrollo Óseo , Huesos/embriología , Embrión de Pollo/embriología , Animales , Imagenología Tridimensional , Movimiento , Microtomografía por Rayos X
18.
Osteoporos Int ; 28(4): 1423-1431, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28074250

RESUMEN

The rate of change in bone density was not different between peri- and post-menopausal women. Differences in rate of change were observed in bone microarchitecture, specifically cortical porosity (Ct.Po), where peri-menopausal women increased +9% per year compared with the +6% per year for post-menopausal women. INTRODUCTION: The purpose of this study was to compare changes in bone density and microarchitecture in peri- and post-menopausal women over 6 years. METHODS: Peri- (n = 26) and post- (n = 65) menopausal women were selected from the Canadian Multicenter Osteoporosis Study. Caucasian women were scanned on dual x-ray absorptiometry (DXA) and high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and follow-up, an average 6 years later. To compare repeat scans, automated 3D image registration was conducted. At the radius and tibia, total volumetric BMD (Tt.BMD), total bone area (Tt.Ar) and cortical porosity (Ct.Po) were assessed, and finite element analysis estimated apparent bone strength. RESULTS: At the tibia, the rate of change for Ct.Po and Tt.Ar was different between groups. Peri-menopausal women had a + 9% per year increase in Ct.Po, but this increase was slower for post-menopausal women at +6% per year (p = 0.049). In addition, post-menopausal women had an increase in Tt.Ar of +0.13% per year compared with a slower increase of +0.06% per year for peri-menopausal women (p = 0.017). The rate of change of density between groups was not significantly different and was approximately -1% per year at the hip by DXA, and -1% per year at the radius and -0.5% per year tibia by HR-pQCT. CONCLUSION: This is a 6-year prospective HR-pQCT study exploring rate of change in Caucasian peri- and post-menopausal women. The microarchitectural features represented by Ct.Po and Tt.Ar changed at a significantly different rate between groups, but group differences were not detected by density measures.


Asunto(s)
Densidad Ósea/fisiología , Perimenopausia/fisiología , Posmenopausia/fisiología , Radio (Anatomía)/anatomía & histología , Tibia/anatomía & histología , Absorciometría de Fotón , Anciano , Envejecimiento/patología , Envejecimiento/fisiología , Femenino , Análisis de Elementos Finitos , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Porosidad , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/fisiología , Tibia/diagnóstico por imagen , Tibia/fisiología , Tomografía Computarizada por Rayos X/métodos
19.
Osteoporos Int ; 28(1): 245-257, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27475931

RESUMEN

In this study, we determined that operator positioning precision contributes significant measurement error in high-resolution peripheral quantitative computed tomography (HR-pQCT). Moreover, we developed software to quantify intra- and inter-operator variability and demonstrated that standard positioning training (now available as a web-based application) can significantly reduce inter-operator variability. INTRODUCTION: HR-pQCT is increasingly used to assess bone quality, fracture risk, and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection ("scout view image") and define the region to be scanned by positioning a "reference line" on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. METHODS: To evaluate the operator in vivo measurement precision, we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner's software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled six new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. RESULTS: In vivo precision errors were up to threefold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. The inter-operator precision errors were significantly greater than the short-term intra-operator precision (p < 0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators and lower inter-operator reproducibility (p < 0.001). Precision errors were significantly greater for the radius than for the tibia. CONCLUSION: Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online ( http://webapps.radiology.ucsf.edu/refline/ ).


Asunto(s)
Competencia Clínica , Osteoporosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Femenino , Humanos , Capacitación en Servicio/métodos , Masculino , Radio (Anatomía)/diagnóstico por imagen , Reproducibilidad de los Resultados , Diseño de Software , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
20.
Phys Rev Lett ; 118(15): 151801, 2017 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-28452532

RESUMEN

T2K reports its first results in the search for CP violation in neutrino oscillations using appearance and disappearance channels for neutrino- and antineutrino-mode beams. The data include all runs from January 2010 to May 2016 and comprise 7.482×10^{20} protons on target in neutrino mode, which yielded in the far detector 32 e-like and 135 µ-like events, and 7.471×10^{20} protons on target in antineutrino mode, which yielded 4 e-like and 66 µ-like events. Reactor measurements of sin^{2}2θ_{13} have been used as an additional constraint. The one-dimensional confidence interval at 90% for the phase δ_{CP} spans the range (-3.13, -0.39) for normal mass ordering. The CP conservation hypothesis (δ_{CP}=0, π) is excluded at 90% C.L.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA