Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Circulation ; 145(15): 1123-1139, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35404682

RESUMEN

BACKGROUND: Acute myocarditis (AM) is thought to be a rare cardiovascular complication of COVID-19, although minimal data are available beyond case reports. We aim to report the prevalence, baseline characteristics, in-hospital management, and outcomes for patients with COVID-19-associated AM on the basis of a retrospective cohort from 23 hospitals in the United States and Europe. METHODS: A total of 112 patients with suspected AM from 56 963 hospitalized patients with COVID-19 were evaluated between February 1, 2020, and April 30, 2021. Inclusion criteria were hospitalization for COVID-19 and a diagnosis of AM on the basis of endomyocardial biopsy or increased troponin level plus typical signs of AM on cardiac magnetic resonance imaging. We identified 97 patients with possible AM, and among them, 54 patients with definite/probable AM supported by endomyocardial biopsy in 17 (31.5%) patients or magnetic resonance imaging in 50 (92.6%). We analyzed patient characteristics, treatments, and outcomes among all COVID-19-associated AM. RESULTS: AM prevalence among hospitalized patients with COVID-19 was 2.4 per 1000 hospitalizations considering definite/probable and 4.1 per 1000 considering also possible AM. The median age of definite/probable cases was 38 years, and 38.9% were female. On admission, chest pain and dyspnea were the most frequent symptoms (55.5% and 53.7%, respectively). Thirty-one cases (57.4%) occurred in the absence of COVID-19-associated pneumonia. Twenty-one (38.9%) had a fulminant presentation requiring inotropic support or temporary mechanical circulatory support. The composite of in-hospital mortality or temporary mechanical circulatory support occurred in 20.4%. At 120 days, estimated mortality was 6.6%, 15.1% in patients with associated pneumonia versus 0% in patients without pneumonia (P=0.044). During hospitalization, left ventricular ejection fraction, assessed by echocardiography, improved from a median of 40% on admission to 55% at discharge (n=47; P<0.0001) similarly in patients with or without pneumonia. Corticosteroids were frequently administered (55.5%). CONCLUSIONS: AM occurrence is estimated between 2.4 and 4.1 out of 1000 patients hospitalized for COVID-19. The majority of AM occurs in the absence of pneumonia and is often complicated by hemodynamic instability. AM is a rare complication in patients hospitalized for COVID-19, with an outcome that differs on the basis of the presence of concomitant pneumonia.


Asunto(s)
COVID-19 , Miocarditis , Adulto , COVID-19/complicaciones , COVID-19/epidemiología , COVID-19/terapia , Femenino , Humanos , Masculino , Miocarditis/diagnóstico , Miocarditis/epidemiología , Miocarditis/terapia , Prevalencia , Estudios Retrospectivos , SARS-CoV-2 , Volumen Sistólico , Función Ventricular Izquierda
2.
Circulation ; 138(11): 1088-1099, 2018 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-29764898

RESUMEN

BACKGROUND: There is controversy about the outcome of patients with acute myocarditis (AM), and data are lacking on how patients admitted with suspected AM are managed. We report characteristics, in-hospital management, and long-term outcome of patients with AM based on a retrospective multicenter registry from 19 Italian hospitals. METHODS: A total of 684 patients with suspected AM and recent onset of symptoms (<30 days) were screened between May 2001 and February 2017. Patients >70 years of age and those >50 years of age without coronary angiography were excluded. The final study population comprised 443 patients (median age, 34 years; 19.4% female) with AM diagnosed by either endomyocardial biopsy or increased troponin plus edema and late gadolinium enhancement at cardiac magnetic resonance. RESULTS: At presentation, 118 patients (26.6%) had left ventricular ejection fraction <50%, sustained ventricular arrhythmias, or a low cardiac output syndrome, whereas 325 (73.4%) had no such complications. Endomyocardial biopsy was performed in 56 of 443 (12.6%), and a baseline cardiac magnetic resonance was performed in 415 of 443 (93.7%). Cardiac mortality plus heart transplantation rates at 1 and 5 years were 3.0% and 4.1%. Cardiac mortality plus heart transplantation rates were 11.3% and 14.7% in patients with complicated presentation and 0% in uncomplicated cases (log-rank P<0.0001). Major AM-related cardiac events after the acute phase (postdischarge death and heart transplantation, sustained ventricular arrhythmias treated with electric shock or ablation, symptomatic heart failure needing device implantation) occurred in 2.8% at the 5-year follow-up, with a higher incidence in patients with complicated forms (10.8% versus 0% in uncomplicated AM; log-rank P<0.0001). ß-Adrenoceptor blockers were the most frequently used medications both in complicated (61.9%) and in uncomplicated forms (53.8%; P=0.18). After a median time of 196 days, 200 patients had follow-up cardiac magnetic resonance, and 8 of 55 (14.5%) with complications at presentation had left ventricular ejection fraction <50% compared with 1 of 145 (0.7%) of those with uncomplicated presentation. CONCLUSIONS: In this contemporary study, overall serious adverse events after AM were lower than previously reported. However, patients with left ventricular ejection fraction <50%, ventricular arrhythmias, or low cardiac output syndrome at presentation were at higher risk compared with uncomplicated cases that had a benign prognosis and low risk of subsequent left ventricular systolic dysfunction.


Asunto(s)
Miocarditis , Enfermedad Aguda , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Biopsia , Fármacos Cardiovasculares/uso terapéutico , Femenino , Trasplante de Corazón , Mortalidad Hospitalaria , Hospitalización , Humanos , Italia , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Miocarditis/diagnóstico , Miocarditis/mortalidad , Miocarditis/fisiopatología , Miocarditis/terapia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Troponina/sangre , Función Ventricular Izquierda , Adulto Joven
3.
Expert Rev Cardiovasc Ther ; 22(7): 325-337, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38970466

RESUMEN

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen
4.
Int J Cardiol ; 400: 131701, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38168557

RESUMEN

BACKGROUND: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs. METHODS: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs. RESULTS: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups. CONCLUSIONS: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Diseño de Prótesis , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/cirugía
5.
J Clin Med ; 11(4)2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-35207232

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for patients with severe, symptomatic AS, regardless of the transcatheter heart valve (THV) implanted. Prior studies demonstrated a higher device success with lower paravalvular leak (PVL) using the balloon-expandable (BE) Sapien/XT THV vs. a self-expanding (SE) THV. However, few data are available on the performance of a novel BE THV. PURPOSE: to compare early clinical performance and safety of the newly available BE Myval THV (Myval, Meril Life Sciences Pvt. Ltd., India) vs. the commonly used SE (Evolut R, Medtronic) THV. METHODS:  A single-center, retrospective cohort analysis was performed with 166 consecutive patients undergoing TAVR from March 2019 to March 2021 for severe symptomatic AS treated with either the novel BE Myval or the SE Evolut R (ER) bioprosthesis. The primary endpoint was device success at day 30 according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included 30-day all-cause mortality, cardiovascular mortality, more than mild PVL, permanent pacemaker implantation (PPI) rates and a composite of all-cause mortality and disabling stroke at 6 months. RESULTS:  Among the 166 included patients, 108 patients received the SE ER THV and 58 patients were treated with the BE Myval THV. At baseline, the two groups showed comparable demographic characteristics. The primary composite endpoint of early device success occurred in 55 patients (94.8%) in the BE Myval group and in 90 patients (83.3%) in the SE ER group (OR 3.667, 95% CI 1.094-12.14; p = 0.048). At day 30, the BE Myval THV group exhibited a significantly lower incidence of more than mild PVL (BE Myval 3.45% vs. SE ER 14.8%, OR 0.2, 95% CI 0.05-0.8; p = 0.0338), along with a lower rate of PPI (BE Myval 11% vs. SE ER 24.2%, OR 0.38, 95% CI 0.15-0.99; p = 0.0535). At the 6-month follow-up, the incidence of all-cause mortality and disabling stroke did not significantly differ between the two groups, while the incidence of PPI (BE Myval 11% vs. SE ER 27.5%, OR 0.32, CI 95% 0.1273-0.8; p = 0.02) and ≥moderate PVL (BE Myval 6.9% vs. SE ER 19.8%, OR 0.31, 95% CI 0.1-0.94; p = 0.0396) was significantly lower in the BE Myval group. CONCLUSIONS: In patients with severe symptomatic AS undergoing TAVR, the novel Myval BE THV provided a comparable performance to the well-known ER SE THV, and it was associated with a lower rate of PPI and ≥moderate PVL within 30 days and 6 months after the procedure. Randomized, head-to-head comparison trials are needed to confirm our results.

11.
G Ital Cardiol (Rome) ; 7(12): 809-14, 2006 Dec.
Artículo en Italiano | MEDLINE | ID: mdl-17294605

RESUMEN

BACKGROUND: The natural history of atherosclerosis has not clearly been elucidated yet. Some works reported that flogosis plays a role in plaque instability. Why does this inflammatory process start? We investigated the correlation between Chlamydia pneumoniae acute infection and plaque rupture. METHODS: We compared blood concentrations of IgM anti-Chlamydia pneumoniae in patients affected by acute myocardial infarction (AMI) and in patients affected by stable angina. RESULTS: Our results showed a minimal statistical difference, with a more positive value in patients with AMI. Subsequently, the group affected by AMI was divided into two subgroups with and without plaque rupture: the subgroup with plaque rupture showed a higher blood concentration of Chlamydia antibodies. This subgroup was also divided into two other subgroups according to blood white cell concentration: the subgroup with normal concentration of white blood cells showed the highest value of Chlamydia antibodies. CONCLUSIONS: Chlamydia pneumoniae could play an important role in atherosclerotic plaque instability


Asunto(s)
Angina de Pecho/microbiología , Infecciones por Chlamydia/complicaciones , Chlamydophila pneumoniae , Enfermedad de la Arteria Coronaria/microbiología , Infarto del Miocardio/microbiología , Angina de Pecho/inmunología , Angina de Pecho/patología , Anticuerpos Antibacterianos/sangre , Biomarcadores/sangre , Infecciones por Chlamydia/inmunología , Infecciones por Chlamydia/patología , Chlamydophila pneumoniae/inmunología , Enfermedad de la Arteria Coronaria/inmunología , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Infarto del Miocardio/inmunología , Infarto del Miocardio/patología , Estudios Retrospectivos , Rotura Espontánea/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA