Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Radiol ; 88(4): 573-8, 2007 Apr.
Artículo en Francés | MEDLINE | ID: mdl-17464256

RESUMEN

OBJECTIVES: Evaluate the improvement in detecting lung nodules when using multidetector CT (MDCT) computer-assisted diagnosis (CAD). MATERIAL AND METHODS: Three radiologists (R1, R2, R3) with different levels of experience independently interpreted 30 MDCT examinations of the thorax taken for screening purposes, first without and then with CAD. The diagnosis was established by two of the three radiologists interpreting the images together, assisted by the CAD. RESULTS: The consensus reading identified 133 nodules, 61 (46%) of which were 4 mm or larger. The sensitivity values in the detection of nodules before and after using the CAD were 54% and 80% (R1), 38% and 71% (R2), and 70% and 88% (R3), respectively. When considering only the nodules that were 4 mm or larger, the sensitivity values varied before and after using the CAD, from 62% to 95% (R1), from 41% to 84% (R2), and from 74% to 92% (R3). By combining two by two the three radiologists' results obtained without the CAD, the sensitivity values were 65%, 83%, and 77%, respectively, for all the nodules, and 70%, 85%, and 77% for the nodules that were 4 mm or larger. The CAD induced a total of 105 false-positive results, with a mean of 3.5 per examination. CONCLUSION: The lung nodules missed by the radiologist can be detected if the CAD is used as a second reader. The CAD can be at least as beneficial as the use of a second independent reader.


Asunto(s)
Diagnóstico por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Radiología/normas , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Reacciones Falso Positivas , Estudios de Factibilidad , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Estudios Prospectivos , Radiografía Torácica , Sensibilidad y Especificidad , Fumar , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada Espiral
2.
J Radiol ; 85(10 Pt 2): 1766-82, 2004 Oct.
Artículo en Francés | MEDLINE | ID: mdl-15507831

RESUMEN

Magnetic resonance imaging and multislice spiral computed tomography are ideal techniques for assessing cardiac function. The main objectives of this article are to describe the different aspects, global and regional systolic left ventricular function, diastolic left ventricular function and right ventricular function, and to introduce the agreed parameters for this evaluation.


Asunto(s)
Corazón/fisiología , Imagen por Resonancia Magnética , Tomografía Computarizada Espiral , Circulación Coronaria , Diástole , Humanos , Imagen por Resonancia Magnética/métodos , Circulación Pulmonar , Volumen Sistólico , Sístole , Tomografía Computarizada Espiral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA