Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Thromb J ; 22(1): 42, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773510

RESUMEN

BACKGROUND: This study aimed to evaluate the association of antiphospholipid antibodies (aPL) and conventional markers of coagulation with ischemic and bleeding risk in patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI). METHODS: In this prospective two-center observational cohort study, patients with AF and an indication for oral anticoagulation (OAC) were enrolled after PCI. Blood was drawn on day 1-3 after PCI. Dilute Russell's viper venom time was used to determine lupus anticoagulant (LA) in OAC-free plasma. Anti-cardiolipin (aCL) IgG, IgM, and anti-ß2-Glycoprotein 1 (aß2GP1) IgG were analyzed by enzyme-linked immunosorbent assay (ELISA). Fibrinogen (FIB), d-dimer, and prothrombin fragment 1 and 2 (PF 1 + 2) were measured in citrated plasma. The primary ischemic outcome was time to major adverse cardiovascular events (MACE; death, myocardial infarction, or stroke) assessed at 6 months. Bleeding was defined according to International Society on Thrombosis and Haemostasis. RESULTS: 158 patients were enrolled between May 2020 and May 2021 on day 1-3 after PCI. The median age was 78 years (interquartile range [IQR] 72-82), 111 (70%) were male, and 39 (25%) presented with acute coronary syndrome. D-dimer was elevated in 74 (47%) patients, FIB was increased in 40 (25%) and PF1 + 2 in 68 (43%) patients. 32 (20%) patients had ≥ 1 antiphospholipid antibody elevated (aPL; LA: 19 [12%], aCL: 14 [9%], aß2GP1: 2 [1%]). The presence of aPL was neither significantly associated with MACE (HR 1.46, 95% CI [0.39-5.49], p = 0.579), nor bleeding (HR 1.07 [0.30-3.84], p = 0.917). Elevated d-dimer was significantly associated with higher risk for MACE (HR 5.06 [1.09-23.41], p = 0.038) and major bleeding (HR 7.04 [1.58-31.47], p = 0.011). Elevated D-dimer increased the predictive capacity of HAS-BLED for major bleedings (HAS-BLED: AUC 0.71 [0.60-0.83] vs. HAS-BLED + d-dimer: AUC 0.79 [0.70-0.88]; p = 0.025). Increased levels of FIB were associated with higher risk for MACE (HR 3.65 [1.11-11.96], p = 0.033). CONCLUSION: Biomarkers of coagulation might be suitable to assess ischemic and bleeding risk in patients with AF following PCI.

2.
Bioengineering (Basel) ; 11(8)2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39199805

RESUMEN

A new accessory was developed to allow implantation of left ventricular assist devices (LVADs) without requiring an anastomosis to the ascending aorta. The accessory combines the LVAD inflow and outflow into a dual-lumen device. Initial prototypes encountered reduced pump performance in vitro, but a second-generation prototype successfully addressed this issue. This feasibility study aimed to demonstrate the anatomic fit, safe implantation, and hemodynamic effectiveness of the LVAD with the accessory. The accessory was implanted in ten female pigs (104 ± 13 kg). Following sternotomy and apical coring under cardiopulmonary bypass, a balloon catheter was retrogradely inserted and exteriorized through the coring site, where it was inflated within the distal third of the outflow graft. It was utilized to pull the accessory's outflow across the aortic valve. After LVAD attachment, the catheter was removed. Echocardiography revealed no relevant valve regurgitation post-implantation. During ramp testing, pump flow increased from 3.7 ± 1.2 to 5.4 ± 1.2 L/min. Necropsy confirmed correct accessory placement in nine animals. No valve lesions or device thrombosis were observed. The accessory enabled LVAD implantation without compromising pump performance. Future work includes design refinements for implantation without cardiopulmonary bypass and long-term testing in a chronic heart failure model.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA