Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Transfusion ; 63(2): 315-322, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36605019

RESUMEN

BACKGROUND: Preoperative anemia is common and associated with adverse postoperative outcomes. Assessment of hemoglobin concentrations may facilitate optimization prior to surgery. However, phlebotomy-based hemoglobin measurement may contribute to patient discomfort and iatrogenic blood loss, which makes non-invasive hemoglobin estimation attractive in this setting. STUDY DESIGN AND METHODS: This is a prospective study of adult patients presenting for preoperative evaluation before elective surgery at a tertiary care medical center. The Masimo Pronto Pulse CO-Oximeter was utilized to estimate blood hemoglobin concentrations (SpHb), which were then compared with hemoglobin concentrations obtained via complete blood count. Receiver operating curves were used to identify SpHb values maximizing specificity for anemia detection while meeting a minimum sensitivity of 80%. RESULTS: A total of 122 patients were recruited with a median (interquartile range) age of 66 (58, 72) years. SpHb measurements were obtained in 112 patients (92%). SpHb generally overestimated hemoglobin with a mean (± 1.96 × standard deviation) difference of 0.8 (-2.2, 3.9) g/dL. Preoperative anemia, defined by hemoglobin <12.0 g/dL in accordance with institutional protocol, was present in 22 patients (20%). The optimal SpHb cut-point to identify anemia was 13.5 g/dL: sensitivity 86%, specificity 81%, negative predictive value 96%, and positive predictive value 53%. Utilizing this cut-point, 60% (73/122) of patients could have avoided phlebotomy-based hemoglobin assessment, while an anemia diagnosis would have been missed in <3% (3/122). CONCLUSION: The use of SpHb devices for anemia screening in surgical patients is feasible with the potential to reliably rule-out anemia despite limited accuracy.


Asunto(s)
Anemia , Hemoglobinas , Adulto , Humanos , Anemia/diagnóstico , Pruebas Hematológicas , Hemoglobinas/análisis , Oximetría/métodos , Estudios Prospectivos , Cuidados Preoperatorios
2.
Transfusion ; 59(7): 2218-2222, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31002192

RESUMEN

BACKGROUND: The prevention of excessive allogeneic red blood cell (RBC) transfusion is an important component of patient blood management initiatives. In this investigation, changes in transfusion behaviors following modification of computerized physician order entry (CPOE) procedures for RBC transfusions to a single-unit default quantity were assessed. STUDY DESIGN AND METHODS: This is an observational cohort study of adults for whom nonemergency allogeneic RBC transfusions were ordered in the 2 years before and 2 years after the date of modification of the CPOE system to a single-unit default (June 18, 2015). Changes in the frequency of single- versus multiunit RBC transfusion orders and other transfusion metrics were compared between preintervention and postintervention cohorts. RESULTS: A total of 52,773 unique transfusion orders for 61,989 RBC units were included, of which 60,045 (96.9%) were transfused. Single-unit orders increased annually, from 10,404 (74.1%) in the first year to 11,645 (88.6%) in the last year, while multiunit orders decreased by more than half (p < 0.0001). The number of RBC units transfused decreased by 13.9% from 32,528 in the preintervention cohort to 27,497 in the post intervention cohort (p < 0.0001) with an estimated reduction in transfusion-related expenditures of nearly $4 million. The percentage of transfusions associated with a posttransfusion hemoglobin of10 g/dL or greater decreased by 34.5% (p < 0.0001). CONCLUSION: Modification of the CPOE process such that nonemergency RBC transfusion orders were defaulted to a single unit was associated with decreased rates of multiunit RBC transfusion orders, lower transfusion volumes, and substantial cost savings.


Asunto(s)
Almacenamiento de Sangre/métodos , Transfusión de Eritrocitos/estadística & datos numéricos , Sistemas de Entrada de Órdenes Médicas/estadística & datos numéricos , Bancos de Sangre/estadística & datos numéricos , Estudios de Cohortes , Costos y Análisis de Costo , Transfusión de Eritrocitos/economía , Hemoglobinas/análisis , Humanos , Sistemas de Entrada de Órdenes Médicas/economía
3.
Mayo Clin Proc ; 96(12): 2980-2990, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34736775

RESUMEN

OBJECTIVE: To assess changes in inpatient transfusion utilization and patient outcomes with implementation of a comprehensive patient blood management (PBM) program at a large US medical center. PATIENTS AND METHODS: This is an observational study of graduated PBM implementation for hospitalized adults (age ≥18 years) from January 1, 2010, through December 31, 2017, at two integrated hospital campuses at a major academic US medical center. Allogeneic transfusion utilization and clinical outcomes were assessed over time through segmented regression with multivariable adjustment comparing observed outcomes against projected outcomes in the absence of PBM activities. RESULTS: In total, 400,998 admissions were included. Total allogeneic transfusions per 1000 admissions decreased from 607 to 405 over the study time frame, corresponding to an absolute risk reduction for transfusion of 6.0% (95% confidence interval [CI]: 3.6%, 8.3%; P<.001) and a 22% (95% CI: 6%, 37%; P=.006) decrease in the rate of transfusions over projected. The risk of transfusion decreased for all blood components except cryoprecipitate. Transfusion reductions were experienced for all major surgery types except liver transplantation, which remained stable over time. Hospital length of stay (multiplicative increase in geometric mean 0.85 [95% CI: 0.81, 0.89]; P<.001) and incident in-hospital adverse events (absolute risk reduction: 1.5% [95% CI: 0.1%, 3.0%]; P=.04) were lower than projected at the end of the study time frame. CONCLUSION: Patient blood management implementation for hospitalized patients in a large academic center was associated with substantial reductions in transfusion utilization and improved clinical outcomes. Broad-scale implementation of PBM in US hospitals is feasible without signal for patient harm.


Asunto(s)
Centros Médicos Académicos/organización & administración , Transfusión Sanguínea/métodos , Anciano , Transfusión Sanguínea/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Desarrollo de Programa , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA