Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Extra Corpor Technol ; 56(1): 30-31, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38488716

RESUMEN

This article advocates for an open communication culture in the perfusion and cardiothoracic community to enhance patient safety during surgery. All team members, including nurses, anesthesiologists, and perfusionists, should actively contribute their insights. Empowering perfusionists to voice concerns without fear of repercussions is crucial. Involvement in debriefs, root cause analyses and data management systems aids continuous improvement. A robust speak-up culture prevents unsafe practices and elevates perfusion care standards, leading to better patient outcomes.


Asunto(s)
Comunicación , Seguridad del Paciente , Humanos , Perfusión
2.
J Extra Corpor Technol ; 56(1): 20-29, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38488715

RESUMEN

INTRODUCTION: The optimal timing for extracorporeal membrane oxygenation (ECMO) circuit change-out is crucial for the successful management of patients with severe cardiopulmonary failure. This comprehensive review examines the various factors that influence the timing of oxygenator replacement in the ECMO circuit. By considering these factors, clinicians can make informed decisions to ensure timely and effective change-out, enhancing patient outcomes and optimizing the delivery of ECMO therapy. METHODOLOGY: A thorough search of relevant studies on ECMO circuits and oxygenator change-out was conducted using multiple scholarly databases and relevant keywords. Studies published between 2017 and 2023 were included, resulting in 40 studies that met the inclusion criteria. DISCUSSION: Thrombosis within the membrane oxygenator and its impact on dysfunction were identified as significant contributors, highlighting the importance of monitoring coagulation parameters and gas exchange. Several factors, including fibrinogen levels, pre and post-membrane blood gases, plasma-free hemoglobin, D-dimers, platelet function, flows and pressures, and anticoagulation strategy, were found to be important considerations when determining the need for an oxygenator or circuit change-out. The involvement of a multidisciplinary team and thorough preparation were also highlighted as crucial aspects of this process. CONCLUSION: In conclusion, managing circuit change-outs in ECMO therapy requires considering factors such as fibrinogen levels, blood gases, plasma-free hemoglobin, D-dimers, platelet function, flows, pressures, and anticoagulation strategy. Monitoring these parameters allows for early detection of issues, timely interventions, and optimized ECMO therapy. Standardized protocols, personalized anticoagulation approaches, and non-invasive monitoring techniques can improve the safety and effectiveness of circuit change-outs. Further research and collaboration are needed to advance ECMO management and enhance patient outcomes.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Oxigenadores de Membrana , Anticoagulantes , Hemoglobinas , Gases
3.
J Extra Corpor Technol ; 55(4): 218-220, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38099639

RESUMEN

The demand for efficient and adaptable life support systems in the field of Extracorporeal Life Support (ECLS) is steadily increasing. To meet this growing need, there is a requirement for a versatile extracorporeal life support circuit that can be effectively applied in various medical scenarios, especially in tertiary hospitals where multiple ECLS services are utilized. These services include Extracorporeal Membrane Oxygenation (ECMO) for addressing respiratory or cardiac problems, Ventricular Assist Device (VAD) as a bridge to recovery or heart transplant, and Venovenous Bypass (VVB) for assisting liver transplantation. In light of this, we propose the creation of a multipurpose circuit that integrates multiple extracorporeal life support (ECLS) functions to cater to diverse medical needs. This innovative circuit not only offers cost-effectiveness and enhanced safety but also ensures optimal utilization, thereby revolutionizing the realm of life support technologies.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Humanos
5.
Braz J Cardiovasc Surg ; 39(4): e20230236, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038115

RESUMEN

INTRODUCTION: Perfusion safety in cardiac surgery is vital, and this survey explores perfusion practices, perspectives, and challenges related to it. Specifically, it examines the readiness of on-call and emergency operation rooms for perfusion-related procedures during urgent situations. The aim is to identify gaps and enhance perfusion safety protocols, ultimately improving patient care. METHODS: This was a preliminary survey conducted as an initial exploration before committing to a comprehensive study. The sample size was primarily determined based on a one-month time frame. The survey collected data from 236 healthcare professionals, including cardiac surgeons, perfusionists, and anesthetists, using an online platform. Ethical considerations ensured participant anonymity and voluntary participation. The survey comprised multiple-choice and open-ended questions to gather quantitative and qualitative data. RESULTS: The survey found that 53% preferred a dry circuit ready for emergencies, 19.9% preferred primed circuits, and 19.1% chose not to have a ready pump at all. Various reasons influenced these choices, including caseload variations, response times, historical practices, surgeon preferences, and backup perfusionist availability. Infection risk, concerns about error, and team dynamics were additional factors affecting circuit readiness. CONCLUSION: This survey sheds light on current perfusion practices and challenges, emphasizing the importance of standardized protocols in regards to readiness of on-call and emergency operation rooms. It provides valuable insights for advancing perfusion safety and patient care while contributing to the existing literature on the subject.


Asunto(s)
Quirófanos , Humanos , Encuestas y Cuestionarios , Perfusión/métodos , Procedimientos Quirúrgicos Cardíacos , Seguridad del Paciente , Servicio de Urgencia en Hospital/organización & administración
6.
J Extra Corpor Technol ; 56(2): 77-81, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38888551

RESUMEN

Venovenous bypass (VVB) is a technique used in liver transplantation (LT) to maintain hemodynamic stability and abdominal organ perfusion and thereby improve patient outcomes. Despite its perceived benefits, VVB utilization has declined globally due to concerns related to heparinization, major bleeding and the need for expertise. Recent advancements, such as percutaneous cannulation techniques and improved extracorporeal technology have improved the safety of VVB in LT. This paper presents a modified VVB circuit with enhanced safety features. Cannulation plays a pivotal role in VVB establishment, with percutaneous methods increasingly favored. Studies demonstrate VVB's efficacy in improving patient outcomes with lower incidence of acute kidney injury and reduced operative time and blood loss, with no added morbidity or mortality. However, its routine use faces challenges, with alternative techniques gaining traction. Our experience highlights VVB's role in various clinical scenarios, including patients with high Model for End-Stage Liver Disease (MELD) scores, challenging surgical anatomy, portal vein thrombosis and pre-existing cardiovascular disease, emphasizing its safety and efficacy. Continued research is needed to optimize VVB techniques and ensure better outcomes for liver transplant recipients.


Asunto(s)
Trasplante de Hígado , Humanos , Circulación Extracorporea/métodos , Trasplante de Hígado/métodos , Resultado del Tratamiento
7.
J Extra Corpor Technol ; 56(3): 84-93, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39303129

RESUMEN

BACKGROUND: The del Nido cardioplegia solution is a widely used method for myocardial protection in various settings. However, there is limited evidence of its effectiveness in adult cardiac surgery, and the baseline solution, Plasma Lyte A, is not readily available, leading to the use of alternative baseline solutions. This study aims to investigate the effectiveness of routine del Nido cardioplegia in adult cardiac surgery and the impact of different baseline solutions on myocardial protection and other perioperative outcomes. METHODS: This study was a prospective, double-blind randomized parallel group clinical trial conducted at a single tertiary care hospital in Iran. A total of 187 adult patients were evaluated for eligibility, of which 120 met the inclusion criteria for elective isolated CABG surgery. The patients were randomly assigned to three groups, with each group consisting of 40 patients. The control group received a normal saline-based routine del Nido cardioplegia, Intervention Group A received Ringer lactate-based del Nido cardioplegia, and Intervention Group B received plain Ringer-based del Nido cardioplegia. The levels of Creatine Kinase-MB (CK-MB), Troponin T, Troponin I, and lactate were primarily assessed at four different times: after anesthesia induction (Baseline), 2 h, 12 h, and 24 h. RESULTS: Preoperative demographic and clinical characteristics were the same among groups with insignificant differences (p > 0.05). There was no significant difference among groups based on CK-MB, Troponin T, Troponin I, and lactate levels (p = 0.078, 0.143, 0.311, and 0.129 respectively). However, there was a significant difference in the time effect of Troponin T and Lactate (p = 0.034, p = <0.001). CONCLUSION: Normal saline, Ringer lactate, and plain Ringer provide comparable myocardial protection in adult-isolated CABG surgery with modified del Nido cardioplegia. Larger studies are needed to identify the best alternative to Plasma Lyte A while maintaining del Nido cardioplegia as the control.


Asunto(s)
Soluciones Cardiopléjicas , Puente de Arteria Coronaria , Paro Cardíaco Inducido , Humanos , Masculino , Método Doble Ciego , Femenino , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Persona de Mediana Edad , Paro Cardíaco Inducido/métodos , Soluciones Cardiopléjicas/uso terapéutico , Anciano , Estudios Prospectivos , Cloruro de Potasio/uso terapéutico , Resultado del Tratamiento , Manitol , Lidocaína , Soluciones , Electrólitos , Sulfato de Magnesio , Bicarbonato de Sodio
8.
J Extra Corpor Technol ; 56(3): 136-144, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39303137

RESUMEN

INTRODUCTION: Heparin, a commonly used anticoagulant in cardiac surgery, binds to antithrombin III (ATIII) to prevent clot formation. However, heparin resistance (HR) can complicate surgical procedures, leading to increased thromboembolic risks and bleeding complications. Proper diagnosis and management of HR are essential for optimizing surgical outcomes. METHODOLOGY: Diagnosis of HR involves assessing activated clotting time (ACT) and HR assays. Management strategies were identified through a comprehensive review of the literature, including studies exploring heparin dosage adjustments, antithrombin supplementation, and alternative anticoagulants in cardiac surgery patients with HR. A thorough search of relevant studies on HR was conducted using multiple scholarly databases and relevant keywords, resulting in 59 studies that met the inclusion criteria. DISCUSSION: HR occurs when patients do not respond adequately to heparin therapy, requiring higher doses or alternative anticoagulants. Mechanisms of HR include AT III deficiency, PF4 interference, and accelerated heparin clearance. Diagnosis involves assessing ACT and HR assays. HR in cardiac surgery can lead to thromboembolic events, increased bleeding, prolonged hospital stays, and elevated healthcare costs. Management strategies include adjusting heparin dosage, supplementing antithrombin levels, and considering alternative anticoagulants. Multidisciplinary management of HR involves collaboration among various specialities. Strategies include additional heparin doses, fresh frozen plasma (FFP) administration, and antithrombin concentrate supplementation. Emerging alternatives to heparin, such as direct thrombin inhibitors and nafamostat mesilate, are also being explored. CONCLUSION: Optimizing the management of HR is crucial for improving surgical outcomes and reducing complications in cardiac surgery patients. Multidisciplinary approaches and emerging anticoagulation strategies hold promise for addressing this challenge effectively.


Asunto(s)
Anticoagulantes , Procedimientos Quirúrgicos Cardíacos , Resistencia a Medicamentos , Heparina , Humanos , Heparina/uso terapéutico , Heparina/administración & dosificación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Anticoagulantes/administración & dosificación , Anticoagulantes/uso terapéutico , Tromboembolia/prevención & control , Tromboembolia/etiología
9.
Rev. bras. cir. cardiovasc ; 39(4): e20230236, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1569618

RESUMEN

ABSTRACT Introduction: Perfusion safety in cardiac surgery is vital, and this survey explores perfusion practices, perspectives, and challenges related to it. Specifically, it examines the readiness of on-call and emergency operation rooms for perfusion-related procedures during urgent situations. The aim is to identify gaps and enhance perfusion safety protocols, ultimately improving patient care. Methods: This was a preliminary survey conducted as an initial exploration before committing to a comprehensive study. The sample size was primarily determined based on a one-month time frame. The survey collected data from 236 healthcare professionals, including cardiac surgeons, perfusionists, and anesthetists, using an online platform. Ethical considerations ensured participant anonymity and voluntary participation. The survey comprised multiple-choice and open-ended questions to gather quantitative and qualitative data. Results: The survey found that 53% preferred a dry circuit ready for emergencies, 19.9% preferred primed circuits, and 19.1% chose not to have a ready pump at all. Various reasons influenced these choices, including caseload variations, response times, historical practices, surgeon preferences, and backup perfusionist availability. Infection risk, concerns about error, and team dynamics were additional factors affecting circuit readiness. Conclusion: This survey sheds light on current perfusion practices and challenges, emphasizing the importance of standardized protocols in regards to readiness of on-call and emergency operation rooms. It provides valuable insights for advancing perfusion safety and patient care while contributing to the existing literature on the subject.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA