Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Indoor Air ; 31(1): 220-228, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32757287

RESUMEN

Negative ion air purifiers (NIAPs), as a less costly alternative to the HEPA filtration, have been increasingly deployed in China and potentially elsewhere. While reducing indoor concentrations of fine particulate matter (PM2.5 ), NIAPs generate massive amounts of negative ions that may be of health concern. We performed week-long interventions with NIAPs in the dormitories of 56 healthy college students living in Beijing. In a randomized order, each student underwent a true and a sham NIAP session. Cardiorespiratory outcomes were measured before and after each session. The use of true NIAPs reduced indoor PM2.5 concentrations significantly, while notably increased negative ion levels. Increases in PM2.5 and negative ion (NI) exposure were independently associated with increased urinary concentration of malondialdehyde, a biomarker of systemic oxidative stress, resulting in a null net effect of NIAP on malondialdehyde. Likewise, no significant net effects of NIAPs were observed for other outcomes indicative of lung function, vascular tone, arterial stiffness, and inflammation. Our findings suggest that negative ions, possibly along with their reaction products with the room air constituents, adversely affect health. The downsides do not support the use of NIAPs as a health-based mitigation strategy to reduce PM2.5 exposure, especially in residences with PM2.5 concentrations that are not extremely high.


Asunto(s)
Filtros de Aire , Contaminación del Aire Interior/estadística & datos numéricos , Monitoreo del Ambiente , Material Particulado , Contaminantes Atmosféricos , Contaminación del Aire , Biomarcadores , China , Filtración , Vivienda , Humanos , Inflamación , Iones , Estrés Oxidativo , Tamaño de la Partícula , Adulto Joven
2.
Sci Rep ; 6: 23388, 2016 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-27025353

RESUMEN

Humidity is one of the main environmental factors affecting the emission rate and key parameters of formaldehyde and volatile organic compounds (VOCs) from building materials. Meanwhile, the initial emittable concentration (Cm,0) is proved to be the most sensitive key parameter to the emission behaviours. However, there is no report on the relationship between humidity and Cm,0. In this paper, Cm,0 of formaldehyde and hexaldehyde from a type of medium density fiberboard in absolute humidity (AH) range of 4.6-19.6 g/m(3) at 25 °C were tested by virtue of a C-history method. Experimental results indicate that Cm,0 is dramatically dependent on AH, increased by 10 and 2 times for formaldehyde and hexaldehyde when AH rising from 4.6 g/m(3) to 19.6 g/m(3). A linear relationship between the logarithm of Cm,0 and AH is obtained based on the measured results. In addition, a correlation characterizing the association of emission rate and AH is derived. The effectiveness of the correlation is verified with our experimental results as well as data from literature. With the correlations, the Cm,0 or emission rate different from the test AH conditions can be conveniently obtained. This study should be useful for predicting the emission characteristics of humidity changing scenarios and for source control.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA