Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Exp Eye Res ; 241: 109854, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38453037

RESUMEN

Mucosal chemokines have antimicrobial properties and play an important role in mucosal immunity. However, little is known about their expression on the ocular surface. This study aimed to analyze the expression of the mucosal chemokines CCL28, CXCL14 and CXCL17 in corneal and conjunctival epithelial cells under in vitro dry eye (DE) conditions, and in conjunctival samples from healthy subjects and DE patients. Human corneal epithelial cells (HCE) and immortalized human conjunctival epithelial cells (IM-HConEpiC) were incubated under hyperosmolar (400-500 mOsM) or inflammatory (TNF-α 25 ng/mL) conditions for 6 h and 24 h to measure CCL28, CXCL14, and CXCL17 gene expression by RT-PCR and their secretion by immunobead-based analysis (CCL28, CXCL14) and ELISA (CXCL17). Additionally, twenty-seven DE patients and 13 healthy subjects were included in this study. DE-related questionnaires (OSDI, mSIDEQ and NRS) evaluated symptomatology. Ocular surface integrity was assessed using vital staining. Tactile sensitivity was measured with Cochet-Bonnet esthesiometer, and mechanic and thermal (heat and cold) sensitivity using Belmonte's non-contact esthesiometer. Subbasal nerve plexus and dendritic cell density were analyzed by in vivo confocal microscopy. Conjunctival cells from participants were collected by impression cytology to measure mucosal chemokines gene expression by RT-PCR. Our results showed that HCE and IM-HConEpiC cells increased CCL28, CXCL14, and CXCL17 secretion under hyperosmolar conditions. The gene expression of CCL28 was significantly upregulated in conjunctival samples from DE patients. CCL28 expression correlated positively with symptomatology, corneal staining, heat sensitivity threshold, and dendritic cell density. CXCL14 expression correlated positively with age, ocular pain, conjunctival staining, tactile sensitivity, and image reflectivity. CXCL17 expression correlated positively with corneal staining. These results suggest that corneal and conjunctival epithelial cells could be a source of CCL28, CXCL14, and CXCL17 on the ocular surface and that CCL28 might be involved in DE pathogenesis.


Asunto(s)
Dieldrín/análogos & derivados , Síndromes de Ojo Seco , Humanos , Síndromes de Ojo Seco/patología , Quimiocinas/genética , Córnea/patología , Conjuntiva/patología , Quimiocinas CC , Quimiocinas CXC
2.
Exp Eye Res ; 219: 109057, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35358536

RESUMEN

The purpose of this study was to analyze inflammation- and pain-related molecules in tears of patients suffering from chronic ocular pain associated with dry eye (DE) and/or a previous corneal refractive surgery (RS). Based on history, symptomatology, and clinical signs, the subjects (n = 180, 51.0 ± 14.7 years, 118 females, 62 males) in this cross-sectional study were assigned to one of five groups: DE and chronic ocular pain after RS (P/DE-RS, n = 52); asymptomatic subjects, i.e., without DE and chronic ocular pain, after RS (A-RS, n = 30); DE and chronic ocular pain without previous RS (P/DE-nonRS, n = 31); DE, no pain, and no previous RS (DE-nonRS, n = 35); and asymptomatic subjects with no previous RS (controls, n = 32). The tear concentrations of 20 cytokines and substance P (SP) were analyzed by immunobead-based assay and enzyme-linked immunosorbent assay, respectively. We found that tear levels of interleukin (IL)-10 and SP were increased in the RS groups. There were significant differences in IL-8/CXCL8 among the five groups. Nerve growth factor (NGF) tear levels were significantly higher in P/DE-RS than in DE-nonRS and controls. IL-9 had the highest percentage of detection in the P/DE-RS and P/DE-nonRS groups, while macrophage inflammatory protein (MIP)-1α, IL-2, and interferon (IFN)-γ were higher in the P/DE-RS, A-RS, and P/DE-nonRS groups. IL-17A was detected only in the A-RS group. Moderate correlations were observed in the A-RS, P/DE-nonRS, DE-nonRS and controls groups. A positive correlation was obtained between growth related oncogene concentration and tear break-up time (rho = 0.550; p = 0.012), while negative correlation was found between monocyte chemoattractant protein-3/CCL7 and conjunctival staining (rho = -0.560; p = 0.001), both in the A-RS group. IL-10 correlated positively with ocular pain intensity (rho = 0.513; p = 0.003) in the P/DE-nonRS group. Regulated on Activation Normal T Cell Expressed and Secreted/CCL5 correlated negatively with conjunctival staining (rho = -0.545; p = 0.001) in the DE-nonRS group. SP correlated negatively with corneal staining (rho = -0.559; p = 0.001) in the controls. In conclusion, chronic ocular pain was associated with higher IL-9 tear levels. IL-10, SP, MIP-1α/CCL3, IL-2, and IFN-γ were associated with previous RS. Higher levels of IL-8/CXCL8, MIP-1α/CCL3, IL-2, and IFN-γ were associated with DE-related inflammation, while NGF levels were related to chronic ocular pain and DE in RS patients. These findings suggest that improved knowledge of tear cytokines and neuromodulators will lead to a more nuanced understanding of how these molecules can serve as biomarkers of chronic ocular pain, leading to better therapeutic and disease management decisions.


Asunto(s)
Síndromes de Ojo Seco , Enfermedad Injerto contra Huésped , Quimiocina CCL3/metabolismo , Conjuntiva/metabolismo , Estudios Transversales , Citocinas/metabolismo , Síndromes de Ojo Seco/metabolismo , Femenino , Enfermedad Injerto contra Huésped/metabolismo , Humanos , Inflamación/metabolismo , Interleucina-10/metabolismo , Interleucina-2 , Interleucina-8/metabolismo , Interleucina-9/metabolismo , Masculino , Factor de Crecimiento Nervioso , Dolor/metabolismo , Lágrimas/metabolismo
3.
Eye Contact Lens ; 47(1): 8-14, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32097186

RESUMEN

OBJECTIVES: Determining the changes in symptomatology suffered by dry eye disease (DED) patients after an intervention is difficult because there is only one validated questionnaire specifically designed to measure these changes and it is somewhat complex. This work uses a simplified questionnaire to evaluate the changes in DED-related symptoms. METHODS: A new questionnaire based on a global rating of change scale was designed. The Change in Dry Eye Symptoms Questionnaire (CDES-Q) consists of 2 questions: CDES-Q1 asks for the change in symptoms ("better," "same," or "worse") relative to a determined previous time and CDES-Q2 quantifies this change (range: 0 to +100). To evaluate the CDES-Q, a prospective observational study was performed. At baseline (V1; day-0), DED-related symptoms were evaluated using the ocular surface disease index (OSDI). In the post-treatment visit (V2; day-90), OSDI, Symptoms Assessment Questionnaire in Dry Eye (SANDE) II, and CDES-Q were used. Also, clinical evaluations were performed in each visit. RESULTS: Thirty-six patients were included. At V2, OSDI, SANDE II, and CDES-Q showed a significant reduction in symptoms (-7.17±12.73, P=0.0021; -11.29±20.95, P=0.0035; -25.28±42.28, P=0.0011, respectively). Patients who answered "better" in CDES-Q1 showed a significantly lower SANDE II than those who answered "same" or "worse," while SANDE II did not discriminate between these groups. CONCLUSIONS: CDES-Q can be a useful tool for the evaluation of changes in DED-related symptoms. It is simple and better discriminates patients without changes from those who suffered a worsening than SANDE II.


Asunto(s)
Síndromes de Ojo Seco , Síndromes de Ojo Seco/diagnóstico , Humanos , Estudios Prospectivos , Encuestas y Cuestionarios
4.
Exp Eye Res ; 193: 107976, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32081669

RESUMEN

Neuropathic dry eye is one of the most frequently seen complications after corneal refractive surgery, however, its incidence decreases in a significant manner along the first six months postoperative, reaching between 10 and 45% incidence. However, little is known on the inflammatory status of the ocular surface during this recovery process. We aim to analyze the clinical and tear molecule concentration changes along six months after advanced surface ablation for myopia correction, in a prospective study including 18 eyes of 18 subjects who bilaterally underwent advanced surface ablation corneal refractive surgery. Clinical variables (uncorrected distance visual acuity, symptoms, conjunctival hyperemia, tear osmolarity, tear stability, corneal fluorescein staining, conjunctival lissamine staining, Schirmer test, and corneal esthesiometry) and a panel of 23 pro and anti-inflammatory cytokines/chemokines concentration in tears preoperatively and at 1, 3 and 6 months postoperatively were evaluated. We found that uncorrected distance visual acuity improved significantly from baseline at 1-month visit, symptoms improved and tear osmolarity decreased significantly from baseline at 3-month visit and there was a decrease in mechanical corneal threshold between 1-month and 3- and 6-month visits. Regarding tear molecules, IL-4, IL-5, IL-6, IL-13, IL-17A, and IFN-γ tear levels were significantly increased at all the three visits, compared to preoperative levels at V0; IL-2 and VEGF were also significantly increased at 1-month and 6-month visits, but not at 3-month visit, whereas IL-9 IL-10 and IL-12 were only significantly increased at 6-month visit. Although we found that there is a recovery in clinical variables at 6 months postoperatively (i.e. neuropathic dry eye was not developed in the sample), ocular surface homeostasis is not completely restored, as it can be seen by the changes in concentration of some pro and anti-inflammatory molecules measured in tears.


Asunto(s)
Citocinas/metabolismo , Síndromes de Ojo Seco/metabolismo , Terapia por Láser/efectos adversos , Procedimientos Quirúrgicos Refractivos/efectos adversos , Lágrimas/metabolismo , Adulto , Biomarcadores/metabolismo , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Estudios Prospectivos , Factores de Tiempo , Agudeza Visual
5.
Stem Cells ; 35(10): 2160-2174, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28758321

RESUMEN

Limbal stem cells are responsible for the continuous renewal of the corneal epithelium. The destruction or dysfunction of these stem cells or their niche induces limbal stem cell deficiency (LSCD) leading to visual loss, chronic pain, and inflammation of the ocular surface. To restore the ocular surface in cases of bilateral LSCD, an extraocular source of stem cells is needed to avoid dependence on allogeneic limbal stem cells that are difficult to obtain, isolate, and culture. The aim of this work was to test the tolerance and the efficacy of human adipose tissue-derived mesenchymal stem cells (hAT-MSCs) to regenerate the ocular surface in two experimental models of LSCD that closely resemble different severity grades of the human pathology. hAT-MSCs transplanted to the ocular surface of the partial and total LSCD models developed in rabbits were well tolerated, migrated to inflamed tissues, reduced inflammation, and restrained the evolution of corneal neovascularization and corneal opacity. The expression profile of the corneal epithelial cell markers CK3 and E-cadherin, and the limbal epithelial cell markers CK15 and p63 was lost in the LSCD models, but was partially recovered after hAT-MSC transplantation. For the first time, we demonstrated that hAT-MSCs improve corneal and limbal epithelial phenotypes in animal LSCD models. These results support the potential use of hAT-MSCs as a novel treatment of ocular surface failure due to LSCD. hAT-MSCs represent an available, non-immunogenic source of stem cells that may provide therapeutic benefits in addition to reduce health care expenses. Stem Cells 2017;35:2160-2174.


Asunto(s)
Córnea/fisiopatología , Células Madre Mesenquimatosas/metabolismo , Nicho de Células Madre/fisiología , Animales , Células Cultivadas , Humanos , Conejos
6.
Ophthalmic Physiol Opt ; 37(1): 60-70, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-28030882

RESUMEN

PURPOSE: To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. METHODS: Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. RESULTS: Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. CONCLUSIONS: Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort.


Asunto(s)
Parpadeo/fisiología , Conjuntiva/diagnóstico por imagen , Lentes de Contacto Hidrofílicos , Córnea/diagnóstico por imagen , Exposición a Riesgos Ambientales , Satisfacción del Paciente , Agudeza Visual , Adulto , Método Doble Ciego , Femenino , Humanos , Masculino , Encuestas y Cuestionarios , Adulto Joven
7.
Ophthalmology ; 123(1): 141-53, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26520171

RESUMEN

PURPOSE: To assess the efficacy of topical 0.1% fluorometholone in dry eye disease (DED) patients for ameliorating the worsening of the ocular surface when exposed to adverse environments. DESIGN: Single-center, double-masked, randomized, vehicle-controlled clinical trial. PARTICIPANTS: Forty-one patients showing moderate to severe DED. METHODS: Patients randomly received 1 drop 4 times daily of either topical 0.1% fluorometholone (FML group) or topical polyvinyl alcohol (PA group) for 22 days. Corneal and conjunctival staining, conjunctival hyperemia, tear film breakup time (TBUT), tear osmolarity, and the Symptom Assessment in Dry Eye (SANDE) questionnaire scores were determined at baseline. Variables were reassessed on day 21 before and after undergoing a 2-hour controlled adverse environment exposure and again on day 22. MAIN OUTCOMES MEASURES: Percentage of patients showing an increase 1 point or more in corneal staining and a reduction of 2 points or more (0-10 scale) in SANDE score, after the controlled adverse environment exposure and 24 hours later. RESULTS: After 21 days of treatment, the FML group showed greater improvements in corneal and conjunctival staining, hyperemia, and TBUT than the PA group (P≤0.03). After the adverse exposure, the percentage of patients having a 1-grade or more increase in corneal staining was significantly (P = 0.03) higher in the PA group (63.1% vs. 23.8%, respectively). Additionally, the FML group showed no significant changes in corneal staining (mean, 0.86; 95% confidence interval [CI], 0.47-1.25; vs. mean, 1.05; 95% CI, 0.59-1.51, for visit 2 and 3, respectively), conjunctival staining (mean, 0.95; 95% CI, 0.54-1.37 vs. mean, 1.19; 95% CI, 0.75-1.63), and hyperemia (mean, 0.71; 95% CI, 0.41-1.02 vs. 1.14; 95% CI, 0.71-1.58) after the exposure, whereas for the PA group, there was significant worsening (P≤0.009) in these variables (corneal staining: mean, 1.95; 95% CI, 1.57-2.33 vs. mean, 2.58; 95% CI, 2.17-2.98; conjunctival staining: mean, 1.68; 95% CI, 1.29-2.08 vs. mean, 2.47; 95% CI, 2.07-2.88; hyperemia: mean, 1.95; 95% CI, 1.63-2.26 vs. mean, 2.84; 95% CI, 2.62-3.07). CONCLUSIONS: Three-week topical 0.1% fluorometholone therapy is effective not only in reducing ocular surface signs in DED patients, but also especially in preventing exacerbation caused by exposure to a desiccating stress.


Asunto(s)
Conjuntiva/efectos de los fármacos , Córnea/efectos de los fármacos , Deshidratación/complicaciones , Síndromes de Ojo Seco/tratamiento farmacológico , Fluorometolona/administración & dosificación , Administración Tópica , Conjuntiva/patología , Córnea/patología , Deshidratación/patología , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/patología , Femenino , Glucocorticoides/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
8.
Exp Eye Res ; 146: 83-94, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26704459

RESUMEN

The transplantation of limbal epithelial stem cells (LESCs) cultured in vitro is a great advance in the treatment of patients suffering from LESC deficiency. However, the optimal technique for LESC isolation from a healthy limbal niche has not yet been established. Our aim was to determine which isolation method renders the highest recovery of functional LESCs from the human limbus. To achieve this purpose, we compared limbal primary cultures (LPCs) obtained from explants and cell suspensions on plastic culture plates. Cell morphology was observed by phase contrast and transmission electron microscopy. LESC, corneal epithelial cell, fibroblast, endothelial cell, melanocyte, and dendritic cell markers were analyzed by real time by reverse transcription polymerase chain reaction and/or immunofluorescence. In addition, colony forming efficiency (CFE) and the presence of holoclones, meroclones, and paraclones were studied. We observed that LPC cells obtained from both methods had cuboidal morphology, desmosomes, and prominent intermediate filaments. The expression of LESC markers (K14, K15, ABCG2, p63α) was similar or higher in LPCs established through cell suspensions, except the expression of p63α mRNA, and there were no significant differences in the expression of corneal epithelial markers (K3, K12). Endothelial cell (PECAM), melanocyte (MART-1), and dendritic cell (CD11c) proteins were not detected, while fibroblast-protein (S100A4) was detected in all LPCs. The CFE was significantly higher in LPCs from cell suspensions. Cells from confluent LPCs produced by explants generated only paraclones (100%), while the percentage of paraclones from LPCs established through cell suspensions was 90% and the remaining 10% were meroclones. In conclusion, LPCs established from cell suspensions have a cell population richer in functional LESCs than LPCs obtained from explants. These results suggest that in a clinical situation in which it is possible to choose between either of the isolation techniques from the donor limbal tissue, then the cell suspension is probably the best option as long as the cells are expanded following our culture conditions.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Epitelio Corneal/ultraestructura , Limbo de la Córnea/ultraestructura , Células Madre/ultraestructura , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/metabolismo , Separación Celular , Células Cultivadas , Epitelio Corneal/metabolismo , Femenino , Humanos , Limbo de la Córnea/metabolismo , Masculino , Microscopía Electrónica de Transmisión , Persona de Mediana Edad , Células Madre/metabolismo , Donantes de Tejidos
9.
Optom Vis Sci ; 93(5): 482-7, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26808383

RESUMEN

PURPOSE: To assess the interchangeability of tear osmolarity measurements between electrical impedance and freezing-point depression osmometers and to analyze inter-eye tear osmolarity variability measured with these osmometers in healthy subjects. METHODS: Tear osmolarity was measured using the TearLab osmometer (OcuSense Inc., San Diego, CA) and the Fiske 210 microsample osmometer (Advanced Instruments Inc., Norwood, MA). We randomly selected one eye in 50 subjects (29 women, 21 men; mean age, 33.16 ± 6.11 years) to analyze whether osmolarity measurements by these osmometers were interchangeable. Both eyes of 25 patients (15 women, 10 men; mean age, 34.32 ± 6.37 years) were included to analyze inter-eye osmolarity variability. RESULTS: The mean tear osmolarity values measured with the TearLab osmometer were higher (305.22 ± 16.06 mOsm/L) than those with the Fiske 210 osmometer (293.40 ± 12.22 mOsm/L), with the intraclass correlation coefficient being 0.23 (p = 0.051). A Bland-Altman plot showed that the systems were not interchangeable because there was a systematic difference, with the limits of agreement being -17.93 to 41.57 mOsm/L. There were no statistically significant differences (p = 0.5006 and p = 0.6533, respectively) between an individual's eyes measured with either osmometer. CONCLUSIONS: Because the TearLab tear osmolarity measurements were higher than those of the Fiske 210 measurements and the limits of agreement were too wide, the two osmolarity values cannot be used interchangeably. In healthy subjects, there is no difference in tear osmolarity between right and left eyes of the same individual measured with both instruments.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico/instrumentación , Osmometria/instrumentación , Lágrimas/química , Adulto , Síndromes de Ojo Seco/etiología , Impedancia Eléctrica , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Reproducibilidad de los Resultados , Temperatura de Transición , Adulto Joven
10.
Optom Vis Sci ; 93(8): 892-900, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26636403

RESUMEN

PURPOSE: The aim of this study was to analyze whether symptoms of discomfort in hydrogel contact lens (HCL) wearers were associated with changes in corneal sensitivity or levels of tear inflammatory mediators. METHODS: Sixty-six subjects were included: 47 HCL wearers, further divided into 24 symptomatic and 23 asymptomatic wearers by the Contact Lens Dry Eye Questionnaire short form and 19 non-contact lens wearers. At least 24 h after HCL removal, we obtained scores from the Ocular Surface Disease Index and mechanical, hot, and cold corneal thresholds using a Belmonte esthesiometer. We collected 4 µl of tears with a capillary micropipette and measured levels of 12 inflammatory markers using a bead-based array: epidermal growth factor, fractalkine, interleukin-10 (IL-10), IL-1ß, IL-1 receptor antagonist, IL-2, IL-4, IL-6, IL-8, monocyte chemoattractant protein 1, tumor necrosis factor-α, and matrix metalloproteinase 9. RESULTS: There were no significant differences between groups in corneal sensitivity thresholds and levels of tear molecules. The following significant correlations were found in the total sample pooled: Ocular Surface Disease Index correlated with mechanical threshold (p < 0.01; rho = -0.324) and epidermal growth factor (p < 0.01, rho = -0.330), and mechanical threshold correlated with heat threshold (p < 0.01, rho = -0.321). CONCLUSIONS: Twenty-four hours after HCL removal, symptoms of discomfort in HCL wearers are not related to changes in corneal sensitivity or tear inflammatory mediator levels. This might indicate either that HCL wear has no effect on these parameters or that ocular surfaces recover from HCL-caused effects during the first hours after HCL removal. However, there were correlations for associations between symptoms, corneal sensitivity, and some molecules in tears.


Asunto(s)
Lentes de Contacto/efectos adversos , Córnea/inervación , Citocinas/metabolismo , Inflamación/metabolismo , Satisfacción del Paciente , Sensación/fisiología , Lágrimas/metabolismo , Adolescente , Adulto , Biomarcadores/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios , Adulto Joven
11.
Optom Vis Sci ; 92(9): e284-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26204472

RESUMEN

PURPOSE: To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). METHODS: This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (κ) coefficient for quantitative and ordinal variables, respectively. RESULTS: Fourteen subjects were recruited in each city with a mean (± SD) age of 63.0 (± 1.7) and 59.1 (± 0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and κ values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p ≥ 0.75) despite RH values significantly differing (p ≤ 0.005). Significant (p ≤ 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 ± 0.60 vs. 5.26 ± 0.64 seconds; higher RH visit, 2.61 ± 0.32 vs. 5.78 ± 0.88 seconds) and corneal (middle RH, 0.64 ± 0.17 vs. 0.14 ± 0.10; higher RH, 0.60 ± 0.22 vs. 0.0 ± 0.0) and conjunctival staining (middle RH, 0.61 ± 0.17 vs. 0.14 ± 0.08; higher RH, 0.57 ± 0.15 vs. 0.18 ± 0.09). CONCLUSIONS: This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated.


Asunto(s)
Clima , Técnicas de Diagnóstico Oftalmológico/normas , Síndromes de Ojo Seco/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Proyectos Piloto , Portugal , Reproducibilidad de los Resultados , España , Lágrimas/química
12.
Exp Eye Res ; 120: 43-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24412438

RESUMEN

Tear levels of certain cytokines/chemokines can potentially serve as biomarkers for dry eye and other ocular surface diseases if they remain stable from day-to-day in healthy eyes. The aim of this study was to determine the normal intra- and inter-day variation of selected tear cytokines/chemokines. Tear samples from 24 young, healthy adults were collected 11:00 AM-1:00 PM (mid-day) and 5:00-7:00 PM (evening) on three non-consecutive days. Concentrations of 18 cytokines/chemokines (EGF, eotaxin, CX3CL1/fractalkine, GM-CSF, IFN-γ, IL-10, IL-1ß, IL-13, IL-17A, IL-1RA, IL-5, IL-6, CXCL8/IL-8, IL-9, CXCL10/IP-10, CCL5/RANTES, TNF-α, and VEGF) were measured by multiplex bead analysis. Ocular surface disease was ruled out by clinical tests. A random-effects ANOVA model was used to evaluate intra- and inter-day effects on cytokine/chemokine levels. Repeatability of intra-subject inter-day measurements was assayed by coefficient of variation. Ten out of the 18 molecules had detectable tear levels in >50% of the subjects. Of those, only IL-10 and IL-1ß levels had significant inter-day variations. EGF, CX3CL1/fractalkine, CXCL10/IP-10, and VEGF were consistently higher in the evening compared to the mid-day measurements. EGF, CXCL10/IP-10, VEGF and CXCL8/IL-8had good intra-subject reproducibility. In conclusion, tear cytokines/chemokines can be measured reproducibly over time, with most not having significant inter-day variability. Some varied significantly depending upon the time of tear collection, and these variations should be taken into account when comparisons are made. The good intra-subject reproducibility for EGF, CXCL10/IP-10, CXCL8/IL-8, and VEGF indicates that these molecules could potentially serve as biomarkers of ocular surface disease.


Asunto(s)
Biomarcadores/metabolismo , Quimiocinas/metabolismo , Citocinas/metabolismo , Proteínas del Ojo/metabolismo , Lágrimas/metabolismo , Adolescente , Adulto , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
13.
Graefes Arch Clin Exp Ophthalmol ; 252(8): 1289-95, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24916930

RESUMEN

BACKGROUND: CD44 and RHAMM hyaluronan (HA) receptors have been studied in several systemic diseases such as osteoarthritis and cancer. However, not too much is known about their role in ocular surface disorders. The purpose of this research was to determine if CD44 and RHAMM are implicated in human ocular surface inflammation. METHODS: Upper tarsal conjunctival epithelial samples from patients with active ocular surface inflammation (n = 17) and healthy controls (n = 14) were recovered by brush cytology. Patients were evaluated by an ophthalmologist and classified in different groups according to the etiology (immune atopic diseases or immune non-atopic diseases) and inflammation intensity (mild/moderate or severe). CD44, RHAMM, and p53 mRNAs were measured using real-time PCR. RESULTS: CD44, RHAMM, and p53 mRNAs were detected in all samples. In immune atopic diseases, higher levels of CD44 and RHAMM mRNAs were present, reaching a 300 % increase for RHAMM in severe inflammation (p < 0.001). In contrast, in immune non-atopic diseases, the HA receptors were downregulated. CD44 tended to decrease up to 30 % in severe patients (p = 0.06), and RHAMM decreased 40 % in severe inflammation (p = 0.021). CONCLUSIONS: RHAMM may be implicated in severe ocular surface inflammation affecting the upper tarsal conjunctiva.


Asunto(s)
Proteínas de la Matriz Extracelular/genética , Regulación de la Expresión Génica/fisiología , Receptores de Hialuranos/genética , Queratoconjuntivitis/genética , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Proteína p53 Supresora de Tumor/genética , Adulto Joven
14.
Ocul Surf ; 32: 130-138, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38395195

RESUMEN

The literature is filled with citations reporting an increased incidence of chronic dry eye disease, also known as keratoconjunctivitis sicca, in patients with systemic autoimmune diseases such as rheumatoid arthritis, Sjögren's Syndrome, systemic sclerosis and lupus. As the most environmentally exposed mucosal surface of the body, the conjunctiva constantly responds to environmental challenges which are typically self limited, but when persistent and unresolved may provoke pathogenic innate and adaptive immune reactions. Our understanding of the pathophysiological mechanisms by which systemic autoimmune diseases cause dry eye inducing ocular surface inflammation continues to evolve. Conjunctival immune tone responds to self or foreign danger signals (including desiccating stress) on the ocular surface with an initial non-specific innate inflammatory response. If unchecked, this can lead to activation of dendritic cells that present antigen and prime T and B cells resulting in an adaptive immune reaction. These reactions generally resolve, but dysfunctional, hyper-responsive immune cells found in systemic autoimmune diseases that are recruited to the ocular surface can amplify inflammatory stress responses in the ocular surface and glandular tissues and result in autoimmune reactions that disrupt tear stability and lead to chronic dry eye disease. We here propose that unique features of the ocular surface immune system and the impact of systemic immune dysregulation in autoimmune diseases, can predispose to development of dry eye disease, and exacerbate severity of existing dry eye.


Asunto(s)
Enfermedades Autoinmunes , Inmunidad Innata , Queratoconjuntivitis Seca , Humanos , Queratoconjuntivitis Seca/inmunología , Enfermedades Autoinmunes/inmunología , Conjuntiva/inmunología , Conjuntiva/patología , Lágrimas/inmunología , Lágrimas/metabolismo
15.
Ophthalmol Ther ; 13(5): 1197-1210, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38446281

RESUMEN

INTRODUCTION: To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments. METHODS: A single-center non-randomized clinical trial was performed at a tertiary care setting. Twenty patients with DED treated with CsA 0.1% CE were exposed to a normal controlled environment (NCE) (23 °C, 50% relative humidity) and an adverse controlled environment (ACE) (23 °C, 10% relative humidity, 0.43 m/s localized airflow) during baseline and the 1- and 3-month visits. Patients underwent the following evaluations: conjunctival hyperemia and staining, corneal fluorescein staining (CFS) using the Oxford and Cornea and Contact Lens Research Unit (CCLRU) scale, meibomian gland (MG) secretion quality, Dry Eye Questionnaire-5, Symptom Assessment in Dry Eye (SANDE II), and Change in Dry Eye Symptoms Questionnaire. Multivariate models were adjusted for statistical analysis. RESULTS: Nineteen women and one man (mean age, 58.9 ± 12.3 years) completed the study. All symptom questionnaires, CFS, conjunctival hyperemia and staining, and MG secretion quality improved (p ≤ 0.003) with 1 month of treatment; improvements were maintained after 3 months (p ≤ 0.02), except for SANDE II (p ≥ 0.07). The CFS worsening (total CCLRU) after baseline ACE exposure (from 8.6 to 10.1) was higher, although not significant (p = 0.64), compared with 1 month (from 5.4 to 5.8) and 3 months (from 5.0 to 5.9) after treatment. CONCLUSION: Topical CsA-0.1% CE improved DED signs and symptoms after 1 month of treatment under controlled environmental conditions. Future studies should confirm the benefit of CsA-0.1% CE in desiccating stress environments. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT04492878.

16.
Exp Eye Res ; 107: 88-100, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23220729

RESUMEN

A role for transforming growth factor (TGF)-ß in the pathogenesis of some ocular surface diseases has been proposed. We determined if secretion of TGF-ß and expression of TGF-ß receptors RI, RII, and RIII by human ocular surface epithelial cells were modified under inflammatory conditions. We also determined how these cells responded to TGF-ß. A human corneal epithelial (HCE) cell line and a conjunctival epithelial cell line (IOBA-NHC) were exposed to TGF-ß1 and -ß2 and to proinflammatory cytokines. TGF-ß receptor mRNAs were analyzed by real time reverse transcription polymerase chain reaction (RT-PCR) in both cell lines, and in conjunctival, limbal, and corneal epithelial cells from post-mortem human specimens. Expression of TGF-ß receptors and pSMAD2/SMAD2 were determined by Western blot and immunofluorescence assays. Secretion of TGF-ß isoforms, cytokine/chemokine, and metalloproteinases (MMPs) were analyzed in cell supernatants by immunobead-based assays. Secretory leukocyte proteinase inhibitor (SLPI) secretion was analyzed by enzyme-linked immunosorbent assay. TGF-ß isoform and receptor gene expression was determined by RT-PCR in conjunctival epithelium of dry eye (DE) patients and healthy subjects. Our results showed that TGF-ß RI expression was down-regulated with IL-4 exposure, whereas TGF-ß RII and TGF-ß2 were upregulated by TNF-α in HCE cells. TGF-ß RIII receptor expression was upregulated in IOBA-NHC cells by TNF-α and IFN-γ. SMAD2 phosphorylation occurred in HCE and IOBA-NHC cells after TGF-ß treatment. TGF-ß significantly up- and down-regulated secretion of several cytokines/chemokines by both cell lines and MMP by HCE cells. TGF-ß2 and TGF-ß3 were upregulated and TGF-ß RIII mRNA was down-regulated in DE conjunctival epithelium. These results show that TGF-ß plays an important role in directing local inflammatory responses in ocular surface epithelial cells.


Asunto(s)
Conjuntiva/citología , Células Epiteliales/efectos de los fármacos , Epitelio Corneal/efectos de los fármacos , Factor de Crecimiento Transformador beta1/farmacología , Factor de Crecimiento Transformador beta2/farmacología , Western Blotting , Línea Celular , Citocinas/metabolismo , Síndromes de Ojo Seco/genética , Electroforesis en Gel de Poliacrilamida , Ensayo de Inmunoadsorción Enzimática , Células Epiteliales/metabolismo , Epitelio Corneal/metabolismo , Femenino , Técnica del Anticuerpo Fluorescente Indirecta , Regulación de la Expresión Génica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Proteínas Serina-Treonina Quinasas/genética , Proteínas Serina-Treonina Quinasas/metabolismo , Proteoglicanos/genética , Proteoglicanos/metabolismo , ARN Mensajero/metabolismo , Reacción en Cadena en Tiempo Real de la Polimerasa , Receptor Tipo I de Factor de Crecimiento Transformador beta , Receptor Tipo II de Factor de Crecimiento Transformador beta , Receptores de Factores de Crecimiento Transformadores beta/genética , Receptores de Factores de Crecimiento Transformadores beta/metabolismo , Inhibidor Secretorio de Peptidasas Leucocitarias/metabolismo , Proteína Smad2/metabolismo , Factor de Crecimiento Transformador beta1/metabolismo , Factor de Crecimiento Transformador beta2/metabolismo
17.
J Mater Sci Mater Med ; 24(12): 2819-29, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23892486

RESUMEN

The aim of this work was to evaluate semi-synthetic biopolymers based on chitosan (CH) and gelatin (G) as potential in vitro carrier substrata for human limbal epithelial cells (hLECs). To that end, human corneal epithelial cells (HCE) were cultured onto different CH-G membranes. None of the polymers were cytotoxic and cell proliferation was higher when CH was functionalized with G. Expression levels of corneal epithelial markers (K3, K12, E-caherin, desmoplakin, and zonula occludens (ZO)-1) were better maintained in HCE cells grown on CH-G 20:80 membranes than other proportions. Consequently, CH-G 20:80 was chosen for the subsequent expansion of hLECs. Cells derived from limbal explants were successfully expanded on CH-G 20:80 membranes using a culture medium lacking components of non-human animal origin. The expression levels found for corneal (K3 and K12) and limbal epithelial stem cells (K15) specific markers were similar to or higher than those found in limbal cells grown onto the control substratum. Our results demonstrate that CH-G 20:80 membranes are suitable for the expansion and maintenance of stem cells derived from the limbal niche. These results strongly support the use of polymers as alternative substrata for the transplantation of cultivated limbal cells onto the ocular surface.


Asunto(s)
Biopolímeros/química , Quitosano/química , Epitelio Corneal/citología , Gelatina/química , Células Madre/citología , Técnicas de Cultivo de Célula , Proliferación Celular , Supervivencia Celular , Córnea/patología , Medios de Cultivo/química , Humanos , Ensayo de Materiales , Polímeros/química , Andamios del Tejido
18.
Heliyon ; 9(6): e16995, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37484334

RESUMEN

Purpose: To evaluate patterns and opinion from international experts with respect to dry eye disease (DED) diagnosis in clinical practice. Methods: An online survey was distributed to worldwide DED experts. The use of diagnosis tests was evaluated including: symptoms questionnaires, functional tests, tear stability, tear volume, tear composition, surface damage and inflammation, and eyelid assessment. After the subjective importance of symptoms, tear break up time (TBUT), non-invasive TBUT, Schirmer's test, tear meniscus height, tear osmolarity, tear metalloproteinase 9, blepharitis assessment and non-contact meibography was evaluated according to likert scale. Results: The survey was sent to 109 experts, and 77 completed the questionnaire (rate of response = 70.6%). Most of the participants were from North America (27%) and Europe (40%). A majority of respondents (73%) diagnose DED using clinical signs and symptoms, but not fulfilling a specific criteria. Seventy-six participants (98.7%) use symptoms questionnaires. All participants evaluate damage to ocular surface, and fluorescein staining is the most frequent method used (92%). Also, all the respondents perform meibomian gland and blepharitis assessment. On the other hand, only 69.8% evaluate tear composition, being osmolarity the most common test used (66.2%). Regarding to the importance of tests, TBUT (p = 0.002) and Schirmer's (p = 0.021) were found to be more important to experts from Europe than North America. No differences were found in any other test (p > 0.05). Conclusions: This survey offers updated and day-to-day diagnostic clinical practice by DED worldwide experts. The results highlight the importance of symptoms and clinical signs, but not necessarily following a strict criteria.

19.
Front Toxicol ; 5: 1148357, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37063600

RESUMEN

Human intoxication after mercury exposure is a rare condition that can cause severe damage to the central nervous, respiratory, cardiovascular, renal, gastrointestinal, skin, and visual systems and represents a major public health concern. Ophthalmic involvement includes impaired function of the extraocular muscles and the eyelids, as well as structural changes in the ocular surface, lens, retina, and optic nerve causing a potential irreversible damage to the visual system. Although, there are many pathways for poisoning depending on the mercury form, it has been suggested that tissue distribution does not differ in experimental animals when administered as mercury vapor, organic mercury, or inorganic mercury. Additionally, visual function alterations regarding central visual acuity, color discrimination, contrast sensitivity, visual field and electroretinogram responses have also been described widely. Nevertheless, there is still controversy about whether visual manifestations occur secondary to brain damage or as a direct affectation, and which ocular structure is primarily affected. Despite the use of some imaging techniques such as in vivo confocal microscopy of the cornea, optical coherence tomography (OCT) of the retina and optic nerve, and functional tests such as electroretinography has helped to solve in part this debate, further studies incorporating other imaging modalities such as autofluorescence, OCT angiography or adaptive optics retinal imaging are needed. This review aims to summarize the published structural and functional alterations found in the visual system of patients suffering from mercury intoxication.

20.
Eur J Ophthalmol ; 33(1): 188-195, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35450456

RESUMEN

PURPOSE: Compare 0.30% sodium hyaluronate (0.30%HA) ocular gel with 0.18%HA eye drops in terms of improvement of ocular signs and symptoms, in patients with moderate to severe dry eye disease (DED). METHODS: This was a multicentric, randomized, investigator-masked, non-inferiority, comparative study conducted over 84 days. Three visits were scheduled, testing fluorescein corneal and conjunctival staining (Oxford and Van Bijsterveld scores), tear film break-up time (TBUT), Schirmer test, DED symptoms, 5-Item-Dry-Eye-Questionnaire (5-DEQ), patient and investigator satisfaction and frequency of instillation. RESULTS: At Day 35 (D35) and Day 84 (D84), both groups (n = 35 each) had a significant improvement in corneal staining (p < 0.001) with no inter-group difference. Van Bijsterveld score improved earlier (D35) for 0.30%HA suggesting a faster effect on conjunctival epithelium healing. There was no difference between the two concentrations in terms of TBUT or Schirmer improvements; however, the Schirmer test increase was only significant for 0.30%HA at D35 (p = 0.040). At D35 and D84, both groups showed similar improvements of DED symptoms and DEQ-5 score. Furthermore, treatment satisfaction was similar for the 2 formulations suggesting that daily use of 0.30%HA do not cause gel-related blurred vision disturbances. Frequency of instillation was similar for both groups. CONCLUSION: Our study demonstrates the non-inferiority of 0.30%HA gel compared to 0.18%HA solution in patients with moderate to severe DED. Because of its gel formulation and higher HA concentration providing prolonged comfort without causing visual disturbances, 0.30%HA gel might be adapted for bedtime use or during the day in more severe conditions.


Asunto(s)
Síndromes de Ojo Seco , Ácido Hialurónico , Humanos , Conjuntiva , Síndromes de Ojo Seco/tratamiento farmacológico , Síndromes de Ojo Seco/diagnóstico , Fluoresceína , Ácido Hialurónico/uso terapéutico , Soluciones Oftálmicas , Lágrimas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA