Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artif Organs ; 48(4): 408-417, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38380771

RESUMEN

BACKGROUND: Mechanical cardiac support is currently an effective strategy to reduce morbidity and mortality in pediatric patients. However, solid evidence regarding the feasibility of intracorporeal devices in children still needs to be provided. We report our 10-year experience with intracorporeal left ventricular assist devices (LVAD) in children. MATERIALS AND METHODS: We included all patients undergoing intracorporeal, continuous-flow LVAD implantation between 2012 and 2022. Baseline and postoperative data were collected from the institutional database. RESULTS: Seven HeartWare and 4 HeartMate3 were implanted in 11 patients (median age 13.9 years, median body surface area - BSA - 1.42 m2, IQR 1.06-1.68). The most frequent indication to LVAD implant was dilated cardiomyopathy (72.7%). All candidates underwent a thorough preoperative advanced imaging. Three-dimensional reconstructions and implant fit simulation were performed when BSA was <1.2 m2, weight <30 kg, or internal transverse thoracic diameter <20 cm. There was no operative death. The most common postoperative complication was surgical re-exploration due to bleeding (27.3%). One patient died of severe neurological complications after about 3 months of hospitalization. No late deaths or unplanned re-hospitalizations occurred in the remaining 10, 6 of whom were discharged home. There were no major complications at the follow-up. All survivors underwent successful heart transplantation. CONCLUSIONS: Intracorporeal LVAD implantation proved to be a potentially feasible and safe option in young teenagers and children whose BSA was >1.0 m2. In borderline cases, the 3D reconstruction with implant fit simulation can effectively help to identify those patients who can safely undergo intrathoracic LVAD implantation.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Adolescente , Humanos , Niño , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis/efectos adversos , Complicaciones Posoperatorias , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
2.
ASAIO J ; 70(6): e78-e81, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38652244

RESUMEN

The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.01 m 2 undergoing a safe and effective HeartMate3 implantation despite extremely small thoracic dimensions. Using computed tomography-derived three-dimensional (3D) reconstruction, it was possible to simulate several device positions finding the best HeartMate3 lodging. Simulation-guided pump placement was then obtained in the operating room. Normal HeartMate3 functioning was registered until heart transplant. Our experience shows that preoperative planning and virtual fitting simulation can be effective to assess safety of HeartMate3 implantation even in small children. The 3D reconstruction and simulation may help to increase the pool of children candidates for this device, even though a larger experience is needed to assess the risk profile of the HeartMate3 in such small patients.


Asunto(s)
Corazón Auxiliar , Humanos , Femenino , Niño , Imagen Multimodal/métodos , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad
3.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38317061

RESUMEN

Patients with aortic arch pathologies after surgery for type-A acute aortic dissection represent a challenging population since open surgery is associated with a non-negligible rate of mortality and complications. Microinvasive endovascular aortic arch repair Arch-Thoracic EndoVascular Aortic Repair (Ar-TEVAR) has shown promising results in high-risk patients. Ar-TEVAR is usually performed under general anaesthesia. We report the case of an 83-year-old man with a history of ascending aorta replacement for type-A acute aortic dissection who was referred for an anastomotic pseudoaneurysm. Ar-TEVAR using an off-the-shelf single-branch aortic arch stent graft was chosen. In order to further minimize procedural invasiveness, monitored anaesthesia care (local anaesthesia with sedation and analgesia) was performed since it provides less stress on the cardiovascular and respiratory systems and overall leads to a faster recovery especially in elderly patients.


Asunto(s)
Anestesia , Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Aorta Torácica/cirugía , Prótesis Vascular , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/cirugía , Stents , Resultado del Tratamiento , Disección Aórtica/cirugía , Estudios Retrospectivos
4.
Curr Probl Cardiol ; 49(1 Pt B): 102078, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37716536

RESUMEN

Transfusions are extremely frequent after cardiac surgery, and they have a considerable economic burden and impact on outcomes. Optimal patient blood management could play a fundamental role in reducing the rate of transfusion and Jehovah's Witnesses (JW) represent the ideal surrogate study population. This meta-analysis compares outcomes of JWs and non-JWs' patients undergoing cardiac surgery, assessing the safety of a bloodless cardiac surgery. A scoping review was conducted using a search strategy for studies assessing outcomes of JW undergoing cardiac surgery. The primary outcome was perioperative mortality, and a random-effects meta-analysis was performed. Ten studies were included in our meta-analysis, involving 780 JW patients refusing any type of transfusion ("JW") and 1182 patients accepting transfusion if needed ("non-JW"). 86% of non-JW patients received at least 1 transfusion. There was no significant difference in terms of perioperative mortality (OR 0.91; 95% CI 0.55-1.52; p = 0.72). The volume blood loss was significantly less in the JW (p = 0.001), while the rate of reoperation for bleeding was also lower, but not statistically significative, in the JW (p = 0.16). Both preoperative and postoperative hemoglobin and hematocrit were significantly higher in the JW. Therefore, we concluded that bloodless cardiac surgery is safe and early outcomes are similar between JW and non-JW patients: optimal patient blood management is fundamental in guarantying these results. Further studies are needed to assess if a limitation of transfusion could have a positive long-term impact on outcomes.


Asunto(s)
Procedimientos Médicos y Quirúrgicos sin Sangre , Procedimientos Quirúrgicos Cardíacos , Testigos de Jehová , Humanos , Estudios Retrospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Transfusión Sanguínea
5.
Artículo en Inglés | MEDLINE | ID: mdl-39034189

RESUMEN

BACKGROUND: Cardiac allograft vasculopathy (CAV) assessment post-heart transplantation (HT) typically relies on invasive coronary angiography (ICA). However, cardiac computed tomography angiography (CCTA) is emerging as a promising alternative due to its potential benefits in economic, safety, and logistical aspects. This study aimed to evaluate the impact of a CCTA program on these aspects in CAV surveillance post-HT. METHODS: A retrospective single-center study was conducted between March 2021 and February 2023, involving HT patients who underwent either CCTA or ICA. RESULTS: Among 260 patients undergoing CAV surveillance, 115 (44.2%) patients underwent CCTA, and 145 (55.8%) patients underwent ICA. The CCTA group showed incurred lower overall costs (p â€‹< â€‹0.0001) and shorter hospitalization times (p â€‹< â€‹0.0001) compared to the ICA group. In terms of safety, CCTA surveillance required significantly lower contrast volumes (p â€‹< â€‹0.0001) and lower effective doses (p â€‹= â€‹0.03). CONCLUSION: CCTA emerges as a safe and cost-effective non-invasive alternative for CAV surveillance post-HT, outperforming ICA in terms of safety, logistical aspects, and economic burden.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA