Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 266(3): 791-800, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23264348

RESUMEN

PURPOSE: To assess the effect of a decrease in tube voltage from 120 kVp to 100 kVp on dose, contrast-to-noise ratio (CNR), and three-dimensional (3D) image quality in patients undergoing computed tomographic (CT) colonography as well as to determine how these changes are affected by patient size. MATERIALS AND METHODS: This HIPAA-compliant and institutional review board-approved retrospective study included 63 consecutive patients who underwent CT colonography and who waived informed consent. Scanning was performed with patients in the supine (120 kVp) and prone (100 kVp) positions, with other parameters unchanged. Volume CT dose index (CTDI(vol)), dose-length product (DLP), image noise, attenuation of selected materials, and CNR were compared with the Wilcoxon matched-pairs signed rank test. Two readers blinded to tube voltage independently assessed 3D endoluminal image quality. The k coefficients were calculated for interobserver agreement. Average image quality ratings were compared with the Wilcoxon signed rank test. All recorded data were stratified by patient anteroposterior diameter to determine effects of patient size. RESULTS: Decreasing tube voltage from 120 to 100 kVp resulted in a 20% decrease in CTDI(vol) (P < .001) and a 16% decrease in DLP (P < .001). Image noise increased by 32% (P < .001). Mean attenuation of tagged fluid increased from 395 to 487 HU (P < .001). There was no change in mean CNR of tagged fluid (17.1 at 120 kVp, 16.8 at 100 kVp; P = .37), regardless of patient size. The 3D image quality decreased slightly from a median score of 5 out of 5 to 4 out of 5 (P < .001). There was substantial interobserver agreement. CONCLUSION: A decrease in tube voltage from 120 to 100 kVp results in a significant decrease in radiation dose but only a minimal decrease in 3D image quality at all patient sizes. © RSNA, 2012.


Asunto(s)
Carga Corporal (Radioterapia) , Dosis de Radiación , Protección Radiológica/métodos , Radiometría , Enfermedades del Sigmoide/diagnóstico por imagen , Adulto , Anciano , Colonografía Tomográfica Computarizada , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA