Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Molecules ; 29(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38338382

RESUMEN

Despite the considerable steps taken in the last decade in the context of antineoplastic drug (AD) handling procedures, their mutagenic effect still poses a threat to healthcare personnel actively involved in compounding and administration units. Biological monitoring procedures usually require large volumes of sample and extraction solvents, or do not provide adequate sensitivity. It is here proposed a fast and automated method to evaluate the urinary levels of cyclophosphamide and iphosphamide, composed of a miniaturized solid phase extraction (µSPE) followed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The extraction procedure, developed through design of experiments (DoE) on the ePrep One Workstation, required a total time of 9.5 min per sample, with recoveries of 77-79% and a solvent consumption lower than 1.5 mL per 1 mL of urine sample. Thanks to the UHPLC-MS/MS method, the limits of quantification (LOQ) obtained were lower than 10 pg/mL. The analytical procedure was successfully applied to 23 urine samples from compounding wards of four Italian hospitals, which resulted in contaminations between 27 and 182 pg/mL.


Asunto(s)
Antineoplásicos , Exposición Profesional , Ifosfamida , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida con Espectrometría de Masas , Monitoreo Biológico , Ciclofosfamida , Cromatografía Líquida de Alta Presión/métodos , Extracción en Fase Sólida , Solventes
2.
Molecules ; 28(14)2023 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-37513313

RESUMEN

Formaldehyde (FA) is a toxic compound and a human carcinogen. Regulating FA-releasing substances in commercial goods is a growing and interesting topic: worldwide production sectors, like food industries, textiles, wood manufacture, and cosmetics, are involved. Thus, there is a need for sensitive, economical, and specific FA monitoring tools. Solid-phase microextraction (SPME), with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBHA) on-sample derivatization and gas chromatography, is proposed for FA monitoring of real-life samples. This study reports the use of polydimethylsiloxane (PDMS) as a sorbent phase combined with innovative commercial methods, such as multiple SPME (MSPME) and cooling-assisted SPME, for FA determination. Critical steps, such as extraction and sampling, were evaluated in method development. The derivatization was performed at 60 °C for 30 min, followed by 15 min sampling at 10 °C, in three cycles (SPME Arrow) or six cycles (SPME). The sensitivity was satisfactory for the method's purposes (LOD-LOQ at 11-36 ng L-1, and 8-26 ng L-1, for SPME and SPME Arrow, respectively). The method's linearity ranges from the lower LOQ at trace level (ng L-1) to the upper LOQ at 40 mg L-1. The precision range was 5.7-10.2% and 4.8-9.6% and the accuracy was 97.4% and 96.3% for SPME and SPME Arrow, respectively. The cooling MSPME set-up applied to real commercial goods provided results of quality comparable to previously published data.

3.
Philos Trans A Math Phys Eng Sci ; 378(2183): 20200188, 2020 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-32981442

RESUMEN

We suggest that the unprecedented and unintended decrease of emissions of air pollutants during the COVID-19 lock-down in 2020 could lead to declining seasonal ozone concentrations and positive impacts on crop yields. An initial assessment of the potential effects of COVID-19 emission reductions was made using a set of six scenarios that variously assumed annual European and global emission reductions of 30% and 50% for the energy, industry, road transport and international shipping sectors, and 80% for the aviation sector. The greatest ozone reductions during the growing season reached up to 12 ppb over crop growing regions in Asia and up to 6 ppb in North America and Europe for the 50% global reduction scenario. In Europe, ozone responses are more sensitive to emission declines in other continents, international shipping and aviation than to emissions changes within Europe. We demonstrate that for wheat the overall magnitude of ozone precursor emission changes could lead to yield improvements between 2% and 8%. The expected magnitude of ozone precursor emission reductions during the Northern Hemisphere growing season in 2020 presents an opportunity to test and improve crop models and experimentally based exposure response relationships of ozone impacts on crops, under real-world conditions. This article is part of a discussion meeting issue 'Air quality, past present and future'.


Asunto(s)
Contaminación del Aire/análisis , Betacoronavirus , Infecciones por Coronavirus/epidemiología , Productos Agrícolas/efectos de los fármacos , Productos Agrícolas/crecimiento & desarrollo , Ozono/análisis , Pandemias , Neumonía Viral/epidemiología , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/prevención & control , Contaminación del Aire/estadística & datos numéricos , COVID-19 , Monitoreo del Ambiente , Europa (Continente) , Humanos , Modelos Biológicos , Dióxido de Nitrógeno/análisis , Dióxido de Nitrógeno/toxicidad , Ozono/toxicidad , Medición de Riesgo , SARS-CoV-2 , Estaciones del Año
4.
Clin Lab ; 66(3)2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32162882

RESUMEN

BACKGROUND: The case concerns a 30-year-old woman in the 24th week of pregnancy presenting to the medical emergency room with fever and abdominal pain. Urine sediment microscopy revealed the presence of unknown needle-shaped crystals. METHODS: Crystals identification was performed by Fourier-Transform Infrared Spectroscopy coupled to Attenuated Total Reflectance (FTIR-ATR). RESULTS: Amoxicillin crystals were verified with semiquantitative results of 87.7%. CONCLUSIONS: Drug-induced crystalluria is a frequent finding in urine examination and it may be asymptomatic. FTIR spectroscopy is a rapid and specific tool in identification of crystals and could be useful supporting renal disease diagnosis and monitoring drug therapy.


Asunto(s)
Amoxicilina , Cálculos Urinarios , Adulto , Amoxicilina/química , Amoxicilina/orina , Antibacterianos/química , Antibacterianos/orina , Femenino , Humanos , Microscopía , Embarazo , Complicaciones del Embarazo/diagnóstico , Complicaciones del Embarazo/orina , Espectroscopía Infrarroja por Transformada de Fourier , Urinálisis , Cálculos Urinarios/química , Cálculos Urinarios/orina
5.
Med Lav ; 110(6): 446-458, 2019 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-31846449

RESUMEN

BACKGROUND: In recent years, under-vacuum sealing (UVS) and containers with formalin encapsulated in the lid have been proposed for the reduction of occupational exposure to airborne formaldehyde (FA) in healthcare environments. OBJECTIVES: We are presenting a study focused on the assessment of FA in hospitals: an automatic sampling system was set, different sampling devices were compared, and the concentration of FA was assessed, following its use in different scenarios. METHODS: Three different devices for sampling/measuring FA were compared. They are based on: 1. silica gel cartridges impregnated with 2,4-dinitrophenylhydrazine (2,4-DNPH); 2. SPME® fiber using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine; 3. direct reading commercial instrumentation. Three typical scenarios using FA were investigated: operating theatres where small biopsies are soaked into closed-circuit system 4% FA containers, secretariat of pathology laboratories during the registration of biopsies and pathology laboratories during the filling procedure by UVS and the slicing of biopsies. RESULTS: The automatic sampling system allowed short-, long-, and in continuous-sampling time to measure airborne FA. Different sampling devices provided comparable results when tested to assess FA concentration ranging from 0.020-0.320 ppm in a test chamber, although  the devices based on 2,4-DNPH were  the best in terms of sensitivity and accuracy. The results of 246 samples showed that the FA concentration was less than 0.04 ppm in 91% of the measurements. CONCLUSIONS: The automatic methods efficiently allow sampling and measurement of FA in hospital settings. When using safe practices, the concentration of FA is well below occupational limit values.


Asunto(s)
Monitoreo del Ambiente , Formaldehído , Hospitales , Exposición Profesional , Humanos , Laboratorios
6.
Molecules ; 23(8)2018 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-30050023

RESUMEN

High-throughput screening of samples is the strategy of choice to detect occupational exposure biomarkers, yet it requires a user-friendly apparatus that gives relatively prompt results while ensuring high degrees of selectivity, precision, accuracy and automation, particularly in the preparation process. Miniaturization has attracted much attention in analytical chemistry and has driven solvent and sample savings as easier automation, the latter thanks to the introduction on the market of the three axis autosampler. In light of the above, this contribution describes a novel user-friendly solid-phase microextraction (SPME) off- and on-line platform coupled with gas chromatography and triple quadrupole-mass spectrometry to determine urinary metabolites of polycyclic aromatic hydrocarbons 1- and 2-hydroxy-naphthalene, 9-hydroxy-phenanthrene, 1-hydroxy-pyrene, 3- and 9-hydroxy-benzoantracene, and 3-hydroxy-benzo[a]pyrene. In this new procedure, chromatography's sensitivity is combined with the user-friendliness of N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide on-fiber SPME derivatization using direct immersion sampling; moreover, specific isotope-labelled internal standards provide quantitative accuracy. The detection limits for the seven OH-PAHs ranged from 0.25 to 4.52 ng/L. Intra-(from 2.5 to 3.0%) and inter-session (from 2.4 to 3.9%) repeatability was also evaluated. This method serves to identify suitable risk-control strategies for occupational hygiene conservation programs.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Hidrocarburos Policíclicos Aromáticos/química , Hidrocarburos Policíclicos Aromáticos/aislamiento & purificación , Microextracción en Fase Sólida , Humanos , Límite de Detección , Hidrocarburos Policíclicos Aromáticos/orina
7.
Glob Chang Biol ; 23(11): 4651-4662, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28273392

RESUMEN

Growing food crops to meet global demand and the search for more sustainable cropping systems are increasing the need for new cultivars in key production areas. This study presents the identification of rice traits putatively producing the largest yield benefits in five areas that markedly differ in terms of environmental conditions in the Philippines, India, China, Japan and Italy. The ecophysiological model WARM and sensitivity analysis techniques were used to evaluate phenotypic traits involved with light interception, photosynthetic efficiency, tolerance to abiotic stressors, resistance to fungal pathogens and grain quality. The analysis involved only model parameters that have a close relationship with phenotypic traits breeders are working on, to increase the in vivo feasibility of selected ideotypes. Current climate and future projections were considered, in the light of the resources required by breeding programs and of the role of weather variables in the identification of promising traits. Results suggest that breeding for traits involved with disease resistance, and tolerance to cold- and heat-induced spikelet sterility could provide benefits similar to those obtained from the improvement of traits involved with canopy structure and photosynthetic efficiency. In contrast, potential benefits deriving from improved grain quality traits are restricted by weather variability and markedly affected by G × E interactions. For this reason, district-specific ideotypes were identified using a new index accounting for both their productivity and feasibility.


Asunto(s)
Cambio Climático , Oryza , Cruzamiento , China , Productos Agrícolas , Grano Comestible , Calor , India , Italia , Japón , Oryza/fisiología , Fenotipo , Filipinas
8.
Arh Hig Rada Toksikol ; 75(1): 41-50, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38548384

RESUMEN

Healthcare workers handling antineoplastic drugs (ADs) in preparation units run the risk of occupational exposure to contaminated surfaces and associated mutagenic, teratogenic, and oncogenic effects of those drugs. To minimise this risk, automated compounding systems, mainly robots, have been replacing manual preparation of intravenous drugs for the last 20 years now, and their number is on the rise. To evaluate contamination risk and the quality of the working environment for healthcare workers preparing ADs, we applied the Failure Mode Effects and Criticality Analysis (FMECA) method to compare the acceptable risk level (ARL), based on the risk priority number (RPN) calculated from five identified failure modes, with the measured risk level (MRL). The model has shown higher risk of exposure with powdered ADs and containers not protected by external plastic shrink film, but we found no clear difference in contamination risk between manual and automated preparation. This approach could be useful to assess and prevent the risk of occupational exposure for healthcare workers coming from residual cytotoxic contamination both for current handling procedures and the newly designed ones. At the same time, contamination monitoring data can be used to keep track of the quality of working conditions by comparing the observed risk profiles with the proposed ARL. Our study has shown that automated preparation may have an upper hand in terms of safety but still leaves room for improvement, at least in our four hospitals.


Asunto(s)
Antineoplásicos , Exposición Profesional , Humanos , Sector de Atención de Salud , Antineoplásicos/análisis , Exposición Profesional/efectos adversos , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Hospitales , Personal de Salud , Monitoreo del Ambiente/métodos
9.
Pract Lab Med ; 39: e00392, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38617587

RESUMEN

Objectives: Coronavirus disease 2019 (COVID-19) has a wide spectrum of clinical severity. A cytokine storm is associated with COVID-19 severity. Of these, IL-6 is significantly associated with higher mortality and is also a marker for predicting disease prognosis. IL-6 may act as a target for therapeutics and, a blockade of IL-6 function by Tocilizumab has been described as a treatment of the inflammatory process COVID-19-related. This study aims to describe our experience comparing two different methods, in detail Human IL-6 Instant ELISA and the Elecsys IL-6 based on ECLIA, for the IL-6 assessment. Design and methods: IL-6 levels from serum samples of 104 COVID-19 patients, admitted to the AOU Careggi (Hospital in Florence -Italy), were assessed by using the two above-mentioned methods, and the results were analysed through Passing-Bablok regression fit and Bland-Altman plot. Results: The regression exhibited a linear relation between the methods with a regression equation (y = - 0.13 + 0.63 x; 95 % C.I. intercept = - 0.13 to 4.55; 95 % C.I. slope = 1.03 to 1.26 with R2 = 0.89, p > 0.05), showing a positive slope. The agreement of the two methods reported a bias of -25.0 pg/mL. Thus, the two methods correlate but do not agree in terms of numeric results. Conclusions: The two assays showed good comparability. However, because of the extremely wide linear range of the ECLIA, its throughput and its capacity for immune profiling, it represents an interesting emerging technology in the immunology field.

10.
Arh Hig Rada Toksikol ; 74(3): 187-197, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37791676

RESUMEN

Antineoplastic drugs (ADs) are essential tools in cancer treatment, but their cytotoxicity poses a risk to workers involved in their handling. In a hospital environment fundamental strategies for minimising exposure involve proper use of safety cabinets and closed-circuit transfer devices, along with personnel training and increased awareness of risks. However, medical gloves remain the first line of defence. In this respect the evaluation of glove materials and best choices can improve hospital safety management and prevent potential hazards and long-term consequences. The aim of this study was to assess contamination of gloves in samples taken from AD administration and preparation units of nine Italian hospitals and to raise awareness of the importance of evaluating chemico-physical properties of gloves. Our findings show that 33 % of the analysed gloves were positive for at least one AD, with contaminations ranging from 0.6 to 20,729 pg/ cm2. We proposed the alert glove values (AGVs) for each AD as a limit value for contamination assessment and good practice evaluation. Our findings also point to multiple AD contamination (43 % of positive findings in preparation units), calculated as total AGV (AGV-T), and confirm that gloves should be replaced after 30 min of AD handling, based on cumulative permeation and area under the curve (AUC), to maintain safety and limit dermal exposure.


Asunto(s)
Antineoplásicos , Exposición Profesional , Humanos , Sector de Atención de Salud , Antineoplásicos/efectos adversos , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Hospitales , Guantes Protectores
11.
ACS Omega ; 8(17): 15397-15405, 2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37151501

RESUMEN

Trimellitic, phthalic, and maleic anhydrides are important building blocks to produce polymers and additives, such as plasticizers. In humans, the exposure to these compounds can cause several health issues. In European Union and USA, their presence in substances and mixtures is restricted by CLP Regulation (no. 1272/2008) and HCS/HazCom 2012, respectively, but no information about the corresponding acids is reported. For this reason, a selective method to determine anhydrides in mixtures, in the presence of acids, could be interesting. Nowadays, methods in the literature are either not selective or use explosive and toxic reagents (as diazomethane). In this work, an innovative, greener, and safer method for the simultaneous recognition and quantification of anhydrides and acids, via direct injection gas chromatography-mass spectrometry, is developed. The sample pretreatment consists in selective esterification with absolute ethanol on the anhydride, followed by a treatment with boron trifluoride-methanol for the methylation of remaining carboxylic groups. The optimization of the functionalization, a crucial step of the method, was optimized by experimental design. The limit of detection-limit of quantification (LOD-LOQ) values for trimellitic, phthalic, and maleic anhydrides are 0.31-0.93, 0.47-1.41, and 0.06-0.18 µg/mL, respectively.

12.
J Anal Methods Chem ; 2022: 8690569, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35154846

RESUMEN

The solid-phase microextraction (SPME), invented by Pawliszyn in 1989, today has a renewed and growing use and interest in the scientific community with fourteen techniques currently available on the market. The miniaturization of traditional sample preparation devices fulfills the new request of an environmental friendly analytical chemistry. The recent upswing of these solid-phase microextraction technologies has brought new availability and range of robotic automation. The microextraction solutions propose today on the market can cover a wide variety of analytical fields and applications. This review reports on the state-of-the-art innovative solid-phase microextraction techniques, especially those used for chromatographic separation and mass-spectrometric detection, given the recent improvements in availability and range of automation techniques. The progressively implemented solid-phase microextraction techniques and related automated commercially available devices are classified and described to offer a valuable tool to summarize their potential combinations to face all the laboratories requirements in terms of analytical applications, robustness, sensitivity, and throughput.

13.
Crit Rev Anal Chem ; 52(7): 1702-1716, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34096409

RESUMEN

Formaldehyde (FA) is ubiquitous in the atmospheric environment. It is generally the dominant atmospheric carbonyl compound. Due to its well-known carcinogenicity, FA is a compound that arises the attention in the scientific community. In studies concerning the toxicological effects of FA on humans, animals, and the environment, testing and calibration of air sampling systems and analytical instruments are pivotal. Therefore, the preparation of controllable standard gaseous atmospheres containing FA at levels known with precision and accuracy is essential. This review summarizes the procedures for generating the FA atmosphere, given that operative solutions have been evolving recently. Furthermore, an overview on the available system to collect and store gaseous standard is reported. The progressively implemented FA generation techniques, together with commercially-available instruments, are herein described, classified, and compared.


Asunto(s)
Formaldehído , Gases , Animales , Humanos
14.
Med Pr ; 73(5): 383-396, 2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36374172

RESUMEN

BACKGROUND: Chemotherapy drugs are widely used to treat cancer, but their active compounds represent a danger for workers who could be exposed to them. However, they aren't yet included in directive CE No. 1272/2008 and the European Biosafety Network has only recommended a limit value of 100 pg/cm2 for surface contamination. Thus, it is crucial to assess surface contaminations in healthcare environments. Currently, the technique of choice is surface wipe test combined with liquid chromatography tandem mass spectrometry to achieve high sensibility. MATERIAL AND METHODS: A campaign involving Careggi University Hospital (Florence, Italy) was performed from January 2020 to December 2021, collecting 1449 wipe samples between administration units, preparation unit, and personnel gloves. From the obtained data, the 90th percentile was calculated for 30 antiblastic drugs and proposed as surface exposure levels (SELs); while from data concerning personnel glove contamination, weekly contamination was estimated. RESULTS: In the 2-year period only 417 wipe samples were found positive (28.8%), the majority of which regard samples coming from administration unit bathrooms. The proposed SELs are almost all <100 pg/cm2, except for few drugs which produce higher contamination on bathroom surfaces. Also, the estimation of pharmacy personnel's glove contamination highlighted very low results (ng/week). CONCLUSIONS: Deeply established protocols and procedures for safe handling of ADs allow for obtaining excellent cleaning results and thus a safer work environment, however, the risk of cytostatic contaminations cannot be avoided in healthcare workplaces, and thus a harmonization of classification and labeling of chemotherapy drugs throughout the European Union should be done. Med Pr. 2022;73(5):383-96.


Asunto(s)
Antineoplásicos , Exposición Profesional , Humanos , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Monitoreo del Ambiente/métodos , Antineoplásicos/análisis , Cromatografía Liquida , Lugar de Trabajo , Contaminación de Equipos
15.
Int J Occup Med Environ Health ; 34(3): 319-338, 2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-33236726

RESUMEN

The potential carcinogenicity of formaldehyde (FA) has prompted increasing preventive measures in anatomic pathology (AP) laboratories and new strategies aimed at innovating airborne FA monitoring systems. This review provides an updated overview of the most recent improvements in preventive measures, safe practices, and exposure monitoring tools in the FA usage and handling. A computer-based search of scientific and non-scientific sources was performed on PubMed, Web of Science, Google and Google Patents databases, querying the main topics of real-time, in-continuous FA monitoring instruments for sale, and commercially available tools for improving preventive measures in formalin management. In order to simplify the sampling process and to choose a better analytic solution to FA assessment, the main characteristics of each FA monitoring instrument were described. The novel technical tools recently introduced on the global market, aimed at reducing FA emissions in AP laboratories, were summarized. This review is directed at anatomic pathologists to draw their attention to the rapidly growing field of safe formalin practices. A repeated exposure assessment is recommended to evaluate technical changes in air monitoring programs to keep FA emissions low, in compliance with the limit value; thus, evolved monitoring devices are needed. Int J Occup Med Environ Health. 2021;34(3):319-38.


Asunto(s)
Formaldehído , Exposición Profesional , Computadores , Humanos , Laboratorios , Flujo de Trabajo
16.
J Mass Spectrom ; 55(7): e4481, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31770470

RESUMEN

The determination of urinary S-phenylmercapturic acid (S-PMA) represents the most reliable biomarker to monitor the intake risk of airborne benzene. Recently, the European Chemical Agency deliberated new occupational exposure limits for benzene and recommended an S-PMA biological limit value of 2-µg/g creatinine. This limit is an order of magnitude lower than the previous one, and its determination constitutes a challenge in the analytical field. We developed and validated a method that allows the fully automated and sensitive determination of S-PMA by the use of gas-chromatography negative chemical ionization tandem mass spectrometry in isotopic dilution. For negative chemical ionization, we selected a mixture of 1% isobutane in argon as reactive gas, by studying its chemical ionization mechanism and optimal parameters compared with pure isobutane or pure methane. This gas mixture produces a more abundant signal of the target analyte than isobutane or methane, and it extended the operative lifetime of the ion source, enabling us to start a high-throughput approach of the S-PMA analysis. Moreover, energy-resolved mass spectrometry experiments were carried out to refine the MS/MS analysis conditions, testing nitrogen and argon as collision gases. The method optimization was pursued by a chemometric model by using the experimental design. The quantification limit for S-PMA was 0.10 µg/L. Accuracy (between 98.3% and 99.6%) and precision (ranging from 1.6% to 6.4%) were also evaluated. In conclusion, the newly developed assay represents a powerful tool for the robust, reliable, and sensitive quantification of urinary S-PMA, and because of its automation, it is well suited for application in large environmental and biological monitoring.

17.
Arh Hig Rada Toksikol ; 71(3): 178-189, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33074166

RESUMEN

The last two decades have been crucial for the assessment of airborne formaldehyde (FA) exposure in healthcare environments due to changes in limits and reference values, definition of carcinogenicity, and new monitoring methods. The aim of this study was to analyse twenty years (1999-2019) of experience in automatic, continuous airborne FA monitoring in the Pathology Laboratory and operating rooms at the Careggi University Hospital, Florence, Italy. These 20 years saw gradual improvements in FA monitoring of exposed employees considered at maximum risk, including improvements in analytical methods of detection and sampling strategies, which came with changes in procedures and workflow operations. In 2019, after the adoption of safe practices, including a closed-circuit system using pre-loaded containers and a vacuum sealing, 94 % of the total measurements (FA concentrations) were lower than 16 µg/m3, and only 6 % ranged from 21 to 75 µg/m3. In the studied work units, the ratio between area and personal readings ranged from 0.9 to 1.0, both for long and short-term sampling. Personal sampling was simplified with a new workstation, which integrated different monitoring systems into an innovative ergonomic armchair equipped with personal sampling devices. Area monitoring was also improved with a real-time, continuous photoacoustic instrument. Over these 20 years, FA exposure significantly dropped, which coincided with optimised histology workflow and implementation of safety practices. For high-throughput screening and cost savings we propose an innovative ergonomic armchair station which allows remote continuous monitoring.


Asunto(s)
Exposición Profesional , Monitoreo del Ambiente , Formaldehído , Hospitales , Humanos , Italia , Exposición Profesional/prevención & control
18.
Int J Occup Med Environ Health ; 33(2): 137-150, 2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32080682

RESUMEN

OBJECTIVES: Hydrogen peroxide (HP) accounts for 15% of the total global chemical revenue. According to the National Institute of Occupational Safety and Health, the HP concentration immediately dangerous to human life or health is 75 ppm. Operators exposed to HP should pay attention when choosing the monitoring technique that should be specific and sensitive enough to discriminate the exposure levels from background concentrations. In order to assess the long- and short-term exposure to HP in disinfection processes, the authors compared 6 industrial hygiene monitoring methods to evaluate their efficiency in measuring airborne HP concentrations. MATERIAL AND METHODS: Airborne HP concentrations were evaluated using an on-fiber triphenylphosphine solid-phase microextraction method, and they were compared with those obtained using a 13-mm Swinnex titanium oxysulfate filter holder and 4 portable direct-reading electrochemical sensors. A survey carried out in wood pulp bleaching, food and beverage disinfection processing, and in a hospital department to reduce the risk of spreading nosocomial infections, was performed during routine operations to access the risk of HP occupational exposure. RESULTS: Through the generation of HP gaseous dynamic atmospheres (0.1-85 ppm), the authors evaluated the consistency of the results obtained using the 6 methods described. The monitoring campaigns showed that the increase in HP could be relatively high (until 67 ppm) in food and beverage processing. CONCLUSIONS: In the authors' opinion, the current 8-h time-weighted average limits of 1 ppm for HP do not reflect the actual risk; a short-term exposure limit would, therefore, provide a much better protection. 2020;33(2):137-50.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Desinfectantes/análisis , Monitoreo del Ambiente/métodos , Peróxido de Hidrógeno/análisis , Exposición Profesional/análisis , Humanos , Medición de Riesgo , Sensibilidad y Especificidad , Valores Limites del Umbral
19.
Anal Chim Acta ; 1119: 77-100, 2020 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-32439057

RESUMEN

This review is an update of a previous review in 2009 and covers publications from 2009 to 2019. The review focuses on experimental design, referred to as the design of experiments (DoE), used in developing bioanalytical solid-phase microextraction (SPME) methods. Characteristics of different SPME approaches are illustrated and critically discussed. The literature selection evidences that two-level full factorial designs, with a limited number of factors (<5), are most frequently used for preliminary factors screening. When applying the response surface methodology for the quantitative assessment of factorial effects, few quadratic models were used. The most popular were the rotatable central composite and Box-Benkhen designs. Models including more than four factors, such as fractional factorial designs (including the Plackett-Burman and Taguchi designs), were rarely used. Definitive screening and D-Optimal designs were not reported anywhere in the literature selection. When examining the diagnostic criteria used to evaluate different model's quality and validity, it was apparent the researchers relied heavily on commercial software for experimental design, analysis, and reporting of the results.


Asunto(s)
Bioensayo , Proyectos de Investigación , Microextracción en Fase Sólida , Programas Informáticos
20.
Artículo en Inglés | MEDLINE | ID: mdl-31163683

RESUMEN

Carbonyl compounds (CCs) are products present both as vapors and as condensed species adsorbed on the carbonaceous particle matter dispersed in the air of urban areas, due to vehicular traffic and human activities. Chronic exposure to CCs is a potential health risk given the toxicity of these chemicals. The present study reports on the measurement of the concentrations of 14 CCs in air as vapors and 2.5 µm fraction PM by the ENVINT GAS08/16 gas/aerosol sampler, a serial sampler that uses annular denuder, as sampling device. The 14 CCs were derivatized during sampling prior to gas-chromatographic separation and multiple detection by mass spectrometry, nitrogen-phosphorus thermionic, electron capture detection. Outdoor air multiple samples were collected in four locations in the urban area of Florence. The results evidenced that formaldehyde, acetaldehyde, and acetone were the more abundant CCs in the studied areas. The data collected was discussed considering the particle to vapor ratio of each CC found. The CCs pollution picture obtained was tentatively related to the nature and intensity of the traffic transiting by the sampling sites. This approach allowed to determine 14 CCs in both concentrated and diluted samples and is proposed as a tool for investigating outdoor and indoor pollution.


Asunto(s)
Filtros de Aire , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Aldehídos/análisis , Cromatografía de Gases , Monitoreo del Ambiente/métodos , Acetona/análisis , Adsorción , Italia , Material Particulado/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA