Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 42(5): 583-591, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36920628

RESUMEN

Patients with cardiac implantable electronic device (CIED) and Staphylococcus aureus bacteraemia (SAB) are at risk of having infective endocarditis (IE). The objectives were to describe a Swedish population-based cohort of patients with CIED and SAB, to identify risk factors, and to construct a predictive score for IE. Patients over 18 years old in the Stockholm Region identified to have SAB in the Karolinska Laboratory database from January 2015 through December 2019 were matched to the Swedish Pacemaker and Implantable Cardioverter-Defibrillator ICD Registry to identify the study cohort. Data were collected from study of medical records. A cohort of 274 patients with CIED and SAB was identified and in 38 episodes (14%) IE were diagnosed, 19 with changes on the CIED, and 35 with changes on the left side of the heart. The risk factors predisposition for IE, community acquisition, embolization, time to positivity of blood cultures, and growth in blood culture after start of therapy in blood cultures were independently associated to IE. A score to identify patients with IE was constructed, the CTEPP score, and the chosen cut-off generated a sensitivity of 97%, specificity of 25%, and a negative predictive value of 98%. The score was externally validated in a population-based cohort of patients with CIED and SAB from another Swedish region. We found that 14% of patients with CIED and SAB had definite IE diagnosed. The CTEPP-score can be used to predict the risk of IE and, when negative, the risk is negligible.


Asunto(s)
Bacteriemia , Desfibriladores Implantables , Endocarditis Bacteriana , Endocarditis , Infecciones Estafilocócicas , Humanos , Adolescente , Estudios Retrospectivos , Infecciones Estafilocócicas/diagnóstico , Estudios de Cohortes , Bacteriemia/diagnóstico , Staphylococcus aureus , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/microbiología
2.
Infect Dis (Lond) ; 56(7): 543-553, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38529922

RESUMEN

BACKGROUND: Patients with cardiac implantable electronic device (CIED) and Staphylococcus aureus bacteraemia (SAB) are at risk of having CIED infection, pocket infection or endocarditis. To avoid treatment failures, guidelines recommend that the CIED should be extracted in all cases of SAB butrecent studies indicate low extraction rates and low risk of relapse. The aim of the study was to describe a Swedish population-based cohort of patients with CIED and SAB, the rate of extraction, and treatment failure measured as recurrent SAB. METHODS: Patients identified to have SAB in the Karolinska Laboratory database, serving a population of 1.9 million, from January 2015 through December 2019 were matched to the Swedish ICD and Pacemaker Registry. Patients with CIED and SAB were included. Clinical data were collected from medical records. RESULTS: A cohort of 274 patients was identified and 38 patients (14%)had the CIED extracted. Factors associated with extraction were lower age, lower Charlson comorbidity index, shorter time since CIED implantation, and non-nosocomial acquisition, but not mortality. No patient was put on lifelong antibiotic treatment. Sixteen patients (6%) had a recurrent SAB within one year, two in patients subjected to extraction (5%) and 14 in patients not subjected to CIED-extraction (6%). Three of the 14 patients were found to have definite endocarditis during the recurrent episode. CONCLUSIONS: Despite a low extraction rate, there were few recurrences. We suggest that extraction of the CIED might be omitted if pocket infection, changes on the CIED, or definite endocarditis are not detected.


Asunto(s)
Bacteriemia , Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Infecciones Estafilocócicas , Staphylococcus aureus , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/microbiología , Bacteriemia/epidemiología , Bacteriemia/microbiología , Desfibriladores Implantables/efectos adversos , Suecia/epidemiología , Marcapaso Artificial/microbiología , Marcapaso Artificial/efectos adversos , Persona de Mediana Edad , Anciano de 80 o más Años , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/epidemiología , Staphylococcus aureus/aislamiento & purificación , Remoción de Dispositivos , Recurrencia , Factores de Riesgo , Antibacterianos/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA