Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Neuroeng Rehabil ; 7: 24, 2010 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-20525164

RESUMEN

BACKGROUND: In this work we consider hidden signs (biomarkers) in ongoing EEG activity expressing epileptic tendency, for otherwise normal brain operation. More specifically, this study considers children with controlled epilepsy where only a few seizures without complications were noted before starting medication and who showed no clinical or electrophysiological signs of brain dysfunction. We compare EEG recordings from controlled epileptic children with age-matched control children under two different operations, an eyes closed rest condition and a mathematical task. The aim of this study is to develop reliable techniques for the extraction of biomarkers from EEG that indicate the presence of minor neurophysiological signs in cases where no clinical or significant EEG abnormalities are observed. METHODS: We compare two different approaches for localizing activity differences and retrieving relevant information for classifying the two groups. The first approach focuses on power spectrum analysis whereas the second approach analyzes the functional coupling of cortical assemblies using linear synchronization techniques. RESULTS: Differences could be detected during the control (rest) task, but not on the more demanding mathematical task. The spectral markers provide better diagnostic ability than their synchronization counterparts, even though a combination (or fusion) of both is needed for efficient classification of subjects. CONCLUSIONS: Based on these differences, the study proposes concrete biomarkers that can be used in a decision support system for clinical validation. Fusion of selected biomarkers in the Theta and Alpha bands resulted in an increase of the classification score up to 80% during the rest condition. No significant discrimination was achieved during the performance of a mathematical subtraction task.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Electroencefalografía/métodos , Epilepsia/diagnóstico , Procesamiento de Señales Asistido por Computador , Adolescente , Niño , Femenino , Humanos , Masculino
2.
J Neuroeng Rehabil ; 5: 25, 2008 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-18990257

RESUMEN

In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a scalp potential recording. Furthermore, a review of the performance results of the different techniques is provided to compare these different inverse solutions. The authors also include the results of a Monte-Carlo analysis which they performed to compare four non parametric algorithms and hence contribute to what is presently recorded in the literature. An extensive list of references to the work of other researchers is also provided. This paper starts off with a mathematical description of the inverse problem and proceeds to discuss the two main categories of methods which were developed to solve the EEG inverse problem, mainly the non parametric and parametric methods. The main difference between the two is to whether a fixed number of dipoles is assumed a priori or not. Various techniques falling within these categories are described including minimum norm estimates and their generalizations, LORETA, sLORETA, VARETA, S-MAP, ST-MAP, Backus-Gilbert, LAURA, Shrinking LORETA FOCUSS (SLF), SSLOFO and ALF for non parametric methods and beamforming techniques, BESA, subspace techniques such as MUSIC and methods derived from it, FINES, simulated annealing and computational intelligence algorithms for parametric methods. From a review of the performance of these techniques as documented in the literature, one could conclude that in most cases the LORETA solution gives satisfactory results. In situations involving clusters of dipoles, higher resolution algorithms such as MUSIC or FINES are however preferred. Imposing reliable biophysical and psychological constraints, as done by LAURA has given superior results. The Monte-Carlo analysis performed, comparing WMN, LORETA, sLORETA and SLF, for different noise levels and different simulated source depths has shown that for single source localization, regularized sLORETA gives the best solution in terms of both localization error and ghost sources. Furthermore the computationally intensive solution given by SLF was not found to give any additional benefits under such simulated conditions.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía , Modelos Neurológicos , Modelos Teóricos , Algoritmos , Animales , Humanos
3.
Physiol Meas ; 28(8): 745-71, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17664670

RESUMEN

The back-projected independent components (BICs) of single-trial, auditory P300 and contingent negative variation (CNV) evoked potentials (EPs) were derived using independent component analysis (ICA) and cluster analysis. The method was tested in simulation including a study of the electric dipole equivalents of the signal sources. P300 data were obtained from healthy and Alzheimer's disease (AD) subjects. The BICs were of approximately 100 ms duration and approximated positive- and negative-going half-sinusoids. Some positively and negatively peaking BICs constituting the P300 coincided with known peaks in the averaged P300. However, there were trial-to-trial differences in their occurrences, particularly where a positive or a negative BIC could occur with the same latency in different trials, a fact which would be obscured by averaging them. These variations resulted in marked differences in the shapes of the reconstructed, artefact-free, single-trial P300s. The latencies of the BIC associated with the P3b peak differed between healthy and AD subjects (p < 0.01). More reliable evidence than that obtainable from single-trial or averaged P300s is likely to be found by studying the properties of the BICs over a number of trials. For the CNV, BICs corresponding to both the orienting and the expectancy components were found.


Asunto(s)
Variación Contingente Negativa/fisiología , Electroencefalografía/estadística & datos numéricos , Potenciales Relacionados con Evento P300/fisiología , Adulto , Anciano , Enfermedad de Alzheimer/fisiopatología , Artefactos , Análisis por Conglomerados , Simulación por Computador , Potenciales Evocados Auditivos/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Componente Principal , Valores de Referencia
4.
Comput Intell Neurosci ; : 462593, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18695735

RESUMEN

There is an important evidence of differences in the EEG frequency spectrum of control subjects as compared to epileptic subjects. In particular, the study of children presents difficulties due to the early stages of brain development and the various forms of epilepsy indications. In this study, we consider children that developed epileptic crises in the past but without any other clinical, psychological, or visible neurophysiological findings. The aim of the paper is to develop reliable techniques for testing if such controlled epilepsy induces related spectral differences in the EEG. Spectral features extracted by using nonparametric, signal representation techniques (Fourier and wavelet transform) and a parametric, signal modeling technique (ARMA) are compared and their effect on the classification of the two groups is analyzed. The subjects performed two different tasks: a control (rest) task and a relatively difficult math task. The results show that spectral features extracted by modeling the EEG signals recorded from individual channels by an ARMA model give a higher discrimination between the two subject groups for the control task, where classification scores of up to 100% were obtained with a linear discriminant classifier.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA