Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
2.
Transplantation ; 108(8): 1669-1680, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39012953

RESUMEN

BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.


Asunto(s)
Consenso , Preservación de Órganos , Perfusión , Humanos , Perfusión/normas , Perfusión/métodos , Preservación de Órganos/normas , Preservación de Órganos/métodos , Donantes de Tejidos/provisión & distribución , Trasplante de Órganos/normas , Trasplante de Órganos/métodos , Selección de Donante/normas , Obtención de Tejidos y Órganos/normas , Obtención de Tejidos y Órganos/métodos
3.
Ann Thorac Surg ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023462

RESUMEN

BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.

5.
Circulation ; 105(22): 2588-91, 2002 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-12045161

RESUMEN

BACKGROUND: A lifetime mechanical solution for advanced heart failure must be reliable, with a low risk of life-threatening complications. After extensive laboratory testing, we began clinical trials with an axial flow pump for long-term treatment of New York Heart Association class IV, transplant-ineligible patients. METHODS AND RESULTS: The Jarvik 2000 is a continuous flow device that is implanted in the apex of the left ventricle with offloading to the descending thoracic aorta. Skull-based percutaneous power delivery was derived from cochlear implant technology. We used this system in 4 patients with end-stage dilated cardiomyopathy. Exercise capacity, quality of life, device parameters, and native heart function were monitored serially. One patient died from right heart failure at 3 months. The other patients were discharged from hospital between 3 and 8 weeks postoperatively and are currently New York Heart Association I or II. Follow-up lasted between 9 and 20 months. There has been no device failure or hemolysis. Native heart function and quality of life were markedly improved. CONCLUSIONS: The Jarvik 2000 is a true assist (rather than replacement) device that functions synergistically with the native left ventricle and provides excellent quality of life. Adverse events are infrequent. This blood pump may provide a mechanical solution for end-stage heart failure in the community.


Asunto(s)
Cardiomiopatía Dilatada/terapia , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Disfunción Ventricular/terapia , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Peso Corporal , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiomiopatía Dilatada/complicaciones , Ecocardiografía , Diseño de Equipo , Tolerancia al Ejercicio , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Pruebas de Función Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Calidad de Vida , Recuperación de la Función , Tasa de Supervivencia , Trombosis/prevención & control , Tiempo , Resultado del Tratamiento , Disfunción Ventricular/complicaciones
6.
Ann Thorac Surg ; 74(4): 1080-5, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12400749

RESUMEN

BACKGROUND: Evolving blood pump technology has produced user-friendly continuous flow left ventricular assist devices, but uncertainty exists about the safety of chronic nonpulsatile circulation. We established consistently nonpulsatile blood flow in a sheep model using the Terumo magnetically suspended centrifugal pump. We then compared end-organ function between pulseless and control animals. METHODS: Fifteen healthy sheep (65 to 85 kg) were allocated to either left ventricular assist device (n = 9) or control (n = 6) groups. We implanted the device through a left thoracotomy and determined the flow rate at which pulse pressure was absent. The flow rate was then adjusted to exceed that rate (4.2 +/- 1.5 L/min), and all variables of pump function were continuously monitored by computer. Blood tests were taken serially for hepatic and renal function and plasma renin levels. The sheep were sacrificed electively at 30 (n = 3), 90 (n = 4), 180 (n = 1), and 340 (n = 1) days. Detailed histologic examination was made of the brain, liver, kidney, myocardium, and major arteries. RESULTS: All animals remained in good condition until sacrifice. All measures of end-organ function remained within normal limits for both groups. There were no histologic differences between the organs of pulsatile and nonpulsatile animals. Although there was no significant difference in mean blood pressure, plasma renin levels were substantially elevated in pulseless animals (1.4 +/- 0.3 pg/mL versus 2.9 +/- 0.3 pg/mL; p < 0.05). We also identified thinning of the medial layer of the ascending aorta in nonpulsatile sheep (1.8 +/- 0.4 mm in left ventricular assist device animals versus 2.6 +/- 0.6 mm in control sheep; p < 0.05). CONCLUSIONS: Chronic nonpulsatile circulation was well tolerated, and we found neither functional nor histologic changes in major end organs. The renin-angiotensin system was upregulated, but this did not provide a significant rise in blood pressure. The changes in the aortic wall merit further investigation. As a result of these findings, we consider that nonpulsatile devices can be used safely for long-term circulatory support.


Asunto(s)
Corazón Auxiliar , Circulación Hepática/fisiología , Circulación Renal/fisiología , Animales , Aorta/citología , Velocidad del Flujo Sanguíneo , Encéfalo/citología , Riñón/citología , Hígado/citología , Masculino , Miocardio/citología , Renina/sangre , Ovinos
7.
Eur J Cardiothorac Surg ; 22(2): 228-32, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12142190

RESUMEN

OBJECTIVE: Heart failure is now a public health epidemic. Donor hearts are severely restricted in availability. Permanent mechanical circulatory support or bridge to myocardial recovery are emerging alternatives. After extensive laboratory experience we sought to evaluate the intraventricular Jarvik 2000 Heart in patients with endstage heart failure. METHODS: The Jarvik 2000 Heart is a novel thumb-sized left ventricular assist device (LVAD) which is fitted within the apex of the native left ventricle. A vascular graft off loads this to the descending thoracic aorta. The pump rotor spins at between 8000 and 12,000 rpm providing 5-6 litres blood flow per minute. We have used the device with skull-mounted power delivery for seven permanent implants and trans-abdominal drive line for ten bridge-to-transplant patients. RESULTS: All patients survived the operation. Three died from non-device related complications. Survivors had early resolution of heart failure with return to NYHA I/II. All had pulsatile circulation. The device was user-friendly and imperceptible to the patient. Both the pump and native left ventricle contributed to the cardiac output during exercise. Seven patients have been transplanted successfully. All explanted devices were free from thrombus formation. Two permanent implant patients left hospital as early as 3 weeks postoperatively. CONCLUSIONS: The Jarvik 2000 is an effective user-friendly LVAD which allows early discharge from hospital. The intraventricular position has distinct advantages especially through absence of an inflow cannula. Synergy develops between the LVAD and native left ventricle. Early experience suggests that this may be a realistic LVAD to treat heart failure routinely in the outpatient setting.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos , Suministros de Energía Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento
8.
Eur J Cardiothorac Surg ; 43(6): 1237-42, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23345184

RESUMEN

OBJECTIVES: Raised pulmonary artery pressure (PAP), trans-pulmonary gradient (TPG) and pulmonary vascular resistance (PVR) are risk factors for poor outcomes after heart transplant in patients with secondary pulmonary hypertension (PH) and may contraindicate transplant. Unloading of the left ventricle with an implantable left ventricular assist device (LVAD) may reverse these pulmonary vascular changes. We studied the effect of implanting centrifugal LVADs in a cohort of patients with secondary PH as a bridge to candidacy. METHODS: Pulmonary haemodynamics on patients implanted with centrifugal LVADs at a single unit between May 2005 and December 2010 were retrospectively reviewed. RESULTS: Twenty-nine patients were implanted with centrifugal LVADs (eight HeartWare ventricular assist device (HVAD), HeartWare International, USA and 21 VentrAssist, Ventracor Ltd., Australia). Seventeen were ineligible for transplant by virtue of high TPG/PVR. All the patients were optimized with inotrope/balloon pump followed by LVAD insertion. Four required temporary right VAD support. Thirty-day mortality post-LVAD was 3.4% (1 of 29) with a 1-year survival of 85.7% (24 of 28). Thirteen patients have been transplanted to date: 30-day mortality was 7.7% (1 of 13) and 1-year survival was 91% (10 of 11). Baseline and post-VAD pulmonary haemodynamics were significantly improved: systolic PAP (mmHg), mean PAP, TPG (mmHg) of 57 ± 9.5, 42 ± 4.4 and 14 ± 3.9 reduced to 32 ± 7.5, 18 ± 5.5 and 9 ± 3.3, respectively. PVR reduced from 5 ± 1.5 to 2.1 ± 0.5 Wood units (P < 0.05). CONCLUSIONS: In selected heart failure patients with secondary PH, use of centrifugal LVAD results in significant reductions in PAP, TPG and PVR, which are observed within 1 month, reaching a nadir by 3 months. Such patients bridged to candidacy have post-transplant survival comparable with those having a heart transplant as primary treatment.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Hipertensión Pulmonar/fisiopatología , Adolescente , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Análisis de Supervivencia
11.
Am J Cardiol ; 103(9): 1261-8, 2009 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-19406269

RESUMEN

Cardiomyocyte apoptosis has been implicated in the pathogenesis of heart failure (HF). This study was performed in patients with left ventricular (LV) volume overload at different stages in the development of HF to correlate apoptotic gene expression with LV echocardiographic phenotype. LV biopsies were procured from 24 cardiac surgical patients selected from 4 distinct clinical groups (n = 6) in the progression from preserved LV function to HF. Group I consisted of control patients with normal LV function (e.g., with atrial myxoma), group II had aortic regurgitation with LV hypertrophy and preserved systolic function (ejection fraction >50%), group III had aortic regurgitation with LV dysfunction (ejection fraction 30% to 40%), and group IV had end-stage HF (ejection fraction <20%). Biopsies were used to measure mRNA expression of the genetic regulators of mitochondrial (Bad, Bax, Bcl-2, Bcl-xL, and p53) and death-receptor- (Fas and tumor necrosis factor receptor 1 [TNFR1]) mediated apoptotic pathways by reverse transcription-polymerase chain reaction. Caspase activity was determined using specific fluorogenic peptide substrates and immunohistochemistry. Evidence for apoptosis was obtained using terminal deoxynucleotidyl transferase deoxyuridine triphosphate nick end labeling and in situ oligo ligation assays. Expression of proapoptotic factors (Bax, p53, TNFR1), antiapoptotic mitochondrial factor (Bcl-xL), and caspases 3, 8, and 9 increased progressively during the transition from preserved LV function to HF (p <0.05, analysis of variance). No significant difference was found for Bad, Bcl-2, or Fas. No evidence of DNA fragmentation was identified. In conclusion, activation of the cardiomyocyte apoptotic cascade occurs during the development of volume overload-induced HF. Mitochondrial (Bax, p53, caspase 9) and death-receptor mediated (TNFR1, caspase 8) pathways are upregulated but without completion of DNA fragmentation.


Asunto(s)
Apoptosis/fisiología , Gasto Cardíaco Bajo/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Receptores de Muerte Celular/metabolismo , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Anciano , Apoptosis/genética , Biomarcadores/análisis , Biopsia con Aguja , Fragmentación del ADN , Progresión de la Enfermedad , Femenino , Regulación de la Expresión Génica , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/patología , Humanos , Hipertrofia Ventricular Izquierda/genética , Hipertrofia Ventricular Izquierda/patología , Hipertrofia Ventricular Izquierda/fisiopatología , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Mitocondrias/genética , Mitocondrias/metabolismo , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología , Probabilidad , Pronóstico , ARN Mensajero/análisis , Receptores de Muerte Celular/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Medición de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Transducción de Señal/genética , Transducción de Señal/fisiología , Regulación hacia Arriba , Disfunción Ventricular Izquierda/genética , Disfunción Ventricular Izquierda/patología , Proteína X Asociada a bcl-2/genética , Proteína X Asociada a bcl-2/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA