Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Clin Exp Ophthalmol ; 40(8): 792-801, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22594402

RESUMEN

BACKGROUND: To evaluate different mechanisms of primary angle closure and to quantify anterior chamber parameters in these mechanisms using anterior segment optical coherence tomography in an Asian population. DESIGN: Hospital-based cross-sectional observational study. PARTICIPANTS: Forty-eight consecutive patients with primary angle closure glaucoma. METHODS: Patients underwent complete ophthalmic examination and imaging of nasal-temporal angles with anterior segment optical coherence tomography. Images were categorized into four primary angle closure mechanisms: pupil block, plateau iris configuration, Thick peripheral iris roll and exaggerated lens vault. Parameters computed: anterior chamber depth central, anterior chamber depth at 1000 µm and 2000 µm anterior to scleral spur, lens vault, anterior chamber area, angle opening distance, trabecular iris space area and iris thickness. MAIN OUTCOME MEASURE: Anterior chamber parameters and primary angle closure mechanisms. RESULTS: Mean values of anterior chamber depths: central (P < 0.001), at 2000 µm (P < 0.001), 1000 µm (P < 0.001), lens vault (P < 0.001), anterior chamber area (P < 0.001), were significantly different among the four groups. Multivariate analysis showed anterior chamber depths: central, and anterior chamber depth at 2000 µm and anterior chamber area were higher in plateau iris and Thick peripheral iris roll and lower in exaggerated lens vault (P < 0.001) as compared to pupil block mechanism, lens vault was greater in exaggerated lens vault (P < 0.001) and lesser in plateau iris and Thick peripheral iris roll as compared to pupil block mechanism. CONCLUSION: Anterior segment optical coherence tomography may be used for evaluation of underlying primary angle closure mechanism(s) in a patient and tailor the treatment accordingly.


Asunto(s)
Cámara Anterior/patología , Glaucoma de Ángulo Cerrado/diagnóstico , Tomografía de Coherencia Óptica , Anciano , Estudios Transversales , Femenino , Humanos , Presión Intraocular/fisiología , Iris/patología , Cristalino/patología , Masculino
2.
Invest Ophthalmol Vis Sci ; 48(8): 3683-8, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17652739

RESUMEN

PURPOSE: To evaluate the reproducibility of anterior chamber (AC) angle measurements obtained using anterior segment optical coherence tomography (AS-OCT). METHODS: Patients with suspected glaucoma and those with glaucoma, ocular hypertension, or anatomically narrow angles were recruited from the glaucoma service at the National University Hospital, Singapore. All subjects underwent imaging of the nasal, temporal, and inferior AC angles with an AS-OCT prototype under standardized dark and light conditions. For short-term reproducibility analysis, a single observer acquired two sets of images followed by a third set of images acquired by a second observer. The interval between sessions was 10 minutes. For long-term reproducibility analysis, a single observer acquired two sets of images at least 24 hours apart. Images were measured using custom software to determine the AC depth (ACD), angle opening distance at 500 microm (AOD(500)), angle recess area at 500 microm (ARA(500)), and trabecular-iris space area at 500 microm (TISA(500)). The intraclass correlation coefficient (ICC) was calculated as a measure of intraobserver and interobserver reproducibility. RESULTS: Twenty eyes of 20 patients were analyzed for short-term reproducibility, and 23 eyes of 23 patients were analyzed for long-term reproducibility. AC depth measurement demonstrated excellent reproducibility (ICC 0.93-1.00) in both dark and light conditions. For the nasal and temporal quadrants, all AC angle parameters demonstrated good to excellent short-term (ICC 0.67-0.90) and long-term (ICC 0.56-0.93) reproducibility in both dark and light conditions. In the inferior quadrant, reproducibility was lower in all categories of analysis and varied from poor to good (ICC 0.31-0.73). CONCLUSIONS: AS-OCT allows quantitative assessment of the AC angle. The reproducibility of AC angle measurements was good to excellent for the nasal and temporal quadrants. The lower reproducibility of measurements in the inferior quadrant may be unique to this prototype due to difficulty in acquiring high-quality images of the inferior angle. Further assessment of the commercially available AS-OCT is needed to clarify this finding.


Asunto(s)
Cámara Anterior/patología , Glaucoma/patología , Tomografía de Coherencia Óptica/normas , Anciano , Estudios Transversales , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Singapur , Tomografía de Coherencia Óptica/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA