Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ Arrhythm Electrophysiol ; 11(3): e005592, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29874166

RESUMEN

BACKGROUND: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. METHODS AND RESULTS: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start (r=-0.112; P=0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth (P=0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79-6.80); the type of arrhythmia (P=0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08-22.7 and hazard ratio, 2.02; 95% CI, 1.04-3.91, respectively); the operator's (P=0.002) and patient's age (P=0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in <25% of their procedures; 17 (48.6%) operators achieved ZFL in >75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97-0.99) as patient's age decreased by 1 year. Acute procedural success was obtained in all cases. CONCLUSIONS: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator's experience, and patient's age.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Fluoroscopía/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Supraventricular/cirugía , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA