Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Crit Care Med ; 51(1): 136-140, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36519987

RESUMEN

OBJECTIVES: To quantify the accuracy of and clinical events associated with a risk alert threshold for impending hypoglycemia during ICU admissions. DESIGN: Retrospective electronic health record review of clinical events occurring greater than or equal to 1 and less than or equal to 12 hours after the hypoglycemia risk alert threshold was met. SETTING: Adult ICU admissions from June 2020 through April 2021 at the University of Virginia Medical Center. PATIENTS: Three hundred forty-two critically ill adults that were 63.5% male with median age 60.8 years, median weight 79.1 kg, and median body mass index of 27.5 kg/m2. INTERVENTIONS: Real-world testing of our validated predictive model as a clinical decision support tool for ICU hypoglycemia. MEASUREMENTS AND MAIN RESULTS: We retrospectively reviewed 350 hypothetical alerts that met inclusion criteria for analysis. The alerts correctly predicted 48 cases of level 1 hypoglycemia that occurred greater than or equal to 1 and less than or equal to 12 hours after the alert threshold was met (positive predictive value = 13.7%). Twenty-one of these 48 cases (43.8%) involved level 2 hypoglycemia. Notably, three myocardial infarctions, one medical emergency team call, 19 deaths, and 20 arrhythmias occurred greater than or equal to 1 and less than or equal to 12 hours after an alert threshold was met. CONCLUSIONS: Alerts generated by a validated ICU hypoglycemia prediction model had a positive predictive value of 13.7% for real-world hypoglycemia events. This proof-of-concept result suggests that the predictive model offers clinical value, but further prospective testing is needed to confirm this.


Asunto(s)
Deterioro Clínico , Sistemas de Apoyo a Decisiones Clínicas , Hipoglucemia , Adulto , Humanos , Masculino , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Hipoglucemia/diagnóstico , Unidades de Cuidados Intensivos
2.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37578778

RESUMEN

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Estudios de Factibilidad , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA