Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Dent Mater ; 40(6): 958-965, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729780

RESUMEN

OBJECTIVE: To investigate the feasibility of optical coherence tomography (OCT)-based digital image correlation (DIC) analysis and to identify the experimental parameters for measurements of polymerization shrinkage. METHODS: Class I cavities were prepared on bovine incisors and filled with Filtek Z350XT Flowable (Z350F). One OCT image of the polymerized restoration was processed to generate virtually displaced images. In addition, the tooth specimen was physically moved under OCT scanning. A DIC software analyzed these virtual and physical transformation sets and assessed the effects of subset sizes on accuracy. The refractive index of unpolymerized and polymerized Z350F was measured via OCT images. Finally, different particles (70-80 µm glass beads, 150-212 µm glass beads, and 75-150 µm zirconia powder) were added to Z350F to inspect the analyzing quality. RESULTS: The analyses revealed a high correlation (>99.99%) for virtual movements within 131 pixels (639 µm) and low errors (<5.21%) within a 10-µm physical movement. A subset size of 51 × 51 pixels demonstrated the convergence of correlation coefficients and calculation time. The refractive index of Z350F did not change significantly after polymerization. Adding glass beads or zirconia particles caused light reflection or shielding in OCT images, whereas blank Z350F produced the best DIC analysis results. SIGNIFICANCE: The OCT-based DIC analysis with the experimental conditions is feasible in measuring polymerization shrinkage of RBC restorations. The subset size in the DIC analysis should be identified to optimize the analysis conditions and results. Uses of hyper- or hypo-reflective particles is not recommended in this method.


Asunto(s)
Resinas Compuestas , Polimerizacion , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Animales , Bovinos , Resinas Compuestas/química , Circonio/química , Estudios de Factibilidad , Incisivo/diagnóstico por imagen , Ensayo de Materiales , Procesamiento de Imagen Asistido por Computador/métodos , Técnicas In Vitro , Preparación de la Cavidad Dental/métodos , Propiedades de Superficie , Refractometría , Restauración Dental Permanente
2.
Dent Mater ; 40(7): 1064-1071, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38777732

RESUMEN

OBJECTIVES: To examine the polymerization shrinkage of different resin-based composite (RBC) restorations using optical coherence tomography (OCT) image-based digital image correlation (DIC) analysis. METHODS: The refractive index (RI) of three RBCs, Filtek Z350XT (Z350), Z350Flowable (Z350F), and BulkFill Posterior (Bulkfill), was measured before and after polymerization to calibrate their axial dimensions under OCT. Class I cavities were prepared in bovine incisors and individually filled with these RBCs under nonbonded and bonded conditions. A series of OCT images of these restorations were captured during 20-s light polymerization and then input into DIC software to analyze their shrinkage behaviors. The interfacial adaptation was also examined using these OCT images. RESULTS: The RI of the three composites ranged from 1.52 to 1.53, and photopolymerization caused neglectable increases in the RI values. For nonbonded restorations, Z350F showed maximal vertical displacements on the top surfaces (-16.75 µm), followed by Bulkfill (-8.81 µm) and Z350 (-5.97 µm). In their bonded conditions, all showed increased displacements. High variations were observed in displacement measurements on the bottom surfaces. In the temporal analysis, the shrinkage of nonbonded Z350F and Bulkfill decelerated after 6-10 s. However, Z350 showed a rebounding upward displacement after 8.2 s. Significant interfacial gaps were found in nonbonded Z350 and Z350F restorations. SIGNIFICANCE: The novel OCT image-based DIC analysis provided a comprehensive examination of the shrinkage behaviors and debonding of the composite restorations throughout the polymerization process. The flowable composite showed the highest shrinkage displacements. Changes in the shrinkage direction may occur in nonbonded conventional composite restorations.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Polimerizacion , Tomografía de Coherencia Óptica , Resinas Compuestas/química , Tomografía de Coherencia Óptica/métodos , Bovinos , Animales , Ensayo de Materiales , Propiedades de Superficie , Refractometría , Adaptación Marginal Dental , Preparación de la Cavidad Dental , Procesamiento de Imagen Asistido por Computador
3.
Dev Dyn ; 241(10): 1545-61, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22911626

RESUMEN

BACKGROUND: We investigated the roles of p120 catenin, Cdc42, Rac1, and RhoA GTPases in regulating migration of presomitic mesoderm cells in zebrafish embryos. p120 catenin has dual roles: It binds the intracellular and juxtamembrane region of cadherins to stabilize cadherin-mediated adhesion with the aid of RhoA GTPase, and it activates Cdc42 GTPase and Rac1 GTPase in the cytosol to initiate cell motility. RESULTS: During gastrulation of zebrafish embryos, knockdown of the synthesis of zygotic p120 catenin δ1 mRNAs with a splice-site morpholino caused lateral widening and anterior-posterior shortening of the presomitic mesoderm and somites and a shortened anterior-posterior axis. These phenotypes indicate a cell-migration effect. Co-injection of low amounts of wild-type Cdc42 or wild-type Rac1 or dominant-negative RhoA mRNAs, but not constitutively-active Cdc42 mRNA, rescued these p120 catenin δ1-depleted embryos. CONCLUSIONS: These downstream small GTPases require appropriate spatiotemporal stimulation or cycling of GTP to guide mesodermal cell migration. A delicate balance of Rho GTPases and p120 catenin underlies normal development.


Asunto(s)
Movimiento Celular/fisiología , Gastrulación/fisiología , Mesodermo/metabolismo , Pez Cebra/embriología , Proteína de Unión al GTP cdc42/metabolismo , Proteína de Unión al GTP rac1/metabolismo , Animales , Western Blotting , Cateninas/genética , Cateninas/metabolismo , Clonación Molecular , Técnicas de Silenciamiento del Gen , Guanosina Trifosfato/metabolismo , Hibridación in Situ , Mesodermo/citología , Mesodermo/enzimología , Oligonucleótidos Antisentido/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Catenina delta
4.
Materials (Basel) ; 13(6)2020 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-32178450

RESUMEN

The residual stress of thin films during the deposition process can cause the components to have unpredictable deformation and damage, which could affect the service life and reliability of the microsystems. Developing an accurate and reliable method for measuring the residual stress of thin films at the micrometer and nanometer scale is a great challenge. To analyze the residual stress regarding factors such as the mechanical anisotropy and preferred orientation of the materials, information related to the in-depth lattice strain function is required when calculating the depth profiles of the residual strain. For depth-resolved measurements of residual stress, it is strategically advantageous to develop a measurement procedure that is microstructurally independent. Here, by performing an incremental focused ion beam (FIB) ring-core drilling experiment with various depth steps, the digital image correlation (DIC) of the specimen images was obtained. The feasibility of DIC to FIB images was evaluated after the translation test, and an appropriate procedure for reliable results was established. Furthermore, the condition of the film in the function of residual stress was assessed and compared to elucidate the applicability of this technology.

5.
Ultramicroscopy ; 108(7): 619-24, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18037563

RESUMEN

The resonant frequency and sensitivity of flexural vibration for an atomic force microscope (AFM) cantilever with a sidewall probe have been analyzed. A closed-form expression for the sensitivity of vibration modes has been obtained using the relationship between the resonant frequency and contact stiffness of cantilever and sample. The results show that a sidewall scanning AFM is more sensitive when the contact stiffness is lower and that the first mode is the most sensitive. However, the high-order modes become more sensitive than the low-order modes as the contact stiffness increases. The resonance frequency of an AFM cantilever is low when contact stiffness is small. However, the frequency rapidly increases as contact stiffness increases. In addition, it can be found that the effects of the vertical extension on the sensitivity and the resonant frequency of an AFM cantilever are significant. Decreasing the length of vertical extension can increase the resonance frequency and sensitivity of mode 1 when the contact stiffness is small. However, the situation is reverse when the contact stiffness becomes large.

6.
Dent Mater ; 32(12): e362-e373, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27671469

RESUMEN

OBJECTIVES: To investigate the effects of light curing protocols on the shrinkage behaviors, contraction stress, and microleakage in composite restorations by an experimental-numerical hybrid analysis. METHODS: Three groups of human molars were collected to receive different light-curing protocols: vertical or oblique curing at regular intensity, and vertical curing at reduced intensity. For each tooth, the composite fillings were consecutively placed under unbonded and bonded states, and their shrinkage behaviors were examined with a digital image correlation (DIC) technique. The strains of the unbonded restorations were input into two finite element analysis (FEA) models with settings of the composite as either homogeneous or hardened along polymerization gradients. The preliminary solutions were verified by their individual deformations in the bonded restorations. The interfacial microleakage of restorations was also determined by micro-CT scanning and compared with the FEA results. RESULTS: The bonded restorations showed centripetal shrinkage patterns with greater downward displacements than their unbonded restorations. Vertical curing at regular intensity caused the greatest shrinkage strain, contraction stress, and microleakage among the three protocols. Low-intensity curing reduced overall shrinkage strain and displacements at cervical margin, but did not prevent the formation of microleakage. Oblique curing caused asymmetric shrinkage with the tooth-shielded side revealing less deformation. Setting the polymerization-dependent elastic moduli of the composite enhanced the reliability of FEA. SIGNIFICANCE: This hybrid analysis comprehensively examined the polymerization shrinkage behaviors. Both the light intensity and direction affect the shrinkages and contraction stress. Oblique curing decreases shrinkage due to the attenuated irradiation by tooth-shielding rather than modulations of shrinkage direction.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Restauración Dental Permanente , Adaptación Marginal Dental , Ensayo de Materiales , Diente Molar , Polimerizacion , Reproducibilidad de los Resultados
7.
Dent Mater ; 27(2): 134-43, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20951420

RESUMEN

OBJECTIVES: To analyze the influence of cavity geometry and lining materials in MOD composite restorations by characterizing the polymerization shrinkage and cusp deflection. METHODS: Eighty intact molars with similar sizes were collected and randomly divided into eight groups. MOD cavities with various widths and depths were prepared on these teeth: Group I, 2((W)) × 2((D)) mm; Group II, 4((W)) × 2((D)) mm; Groups III, IIIf, IIIg, 2((W)) × 4((D)) mm; and Groups IV, IVf, IVg, 4((W)) × 4((D)) mm. In Groups IIIf and IVf, flowable composite liner was placed prior to composite restoration, while glass-ionomer liner was used in Groups IIIg and IVg. Deformations of restorations resulted from composite shrinkage were recorded for 30 min following light irradiation using a digital-image-correlation (DIC) method to subpixel level. The displacements at the boundaries of the restorations were analyzed using one-way ANOVA and the post hoc test at a 5% significance level. The correlation between the geometric factors and the displacements was also analyzed. RESULTS: The inward displacements on free surfaces were greater than those on the bonded surfaces. Groups with flowable composite linings showed greater amount of displacements on free and bonded surfaces compared to the unlined and glass ionomer lining groups. The correlation analysis showed that the free surface shrinkage was related with the cavity width and C-factor, while cusp deflections were correlated with the cavity depth and the cusp compliance. SIGNIFICANCE: The DIC technique measures composite shrinkage on different boundaries of restorations to facilitate the investigation of polymerization kinetics. Using flowable composite lining and increased cusp depth may aggravate the cusp flexure.


Asunto(s)
Resinas Compuestas/química , Preparación de la Cavidad Dental/clasificación , Materiales Dentales/química , Restauración Dental Permanente/clasificación , Procesamiento de Imagen Asistido por Computador/métodos , Grabado Ácido Dental , Bisfenol A Glicidil Metacrilato/química , Fenómenos Químicos , Recubrimiento de la Cavidad Dental/métodos , Recubrimientos Dentinarios/química , Cementos de Ionómero Vítreo/química , Humanos , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Polimerizacion , Resinas Sintéticas/química , Propiedades de Superficie , Corona del Diente/patología
8.
J Mech Behav Biomed Mater ; 4(3): 322-30, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21316620

RESUMEN

Endodontically-treated teeth are prone to fracture due to loss of tooth structure and altered mechanical behaviors. The stability and rigidity of post-restored teeth, particularly in cases involving periodontal destruction, has not been adequately investigated. This study examined the influence of post material on teeth with simulated bone reduction by a multiparametric evaluation. Sixty extracted premolars of similar sizes were endodontically treated then divided into six groups. Each group was restored with one of the combinations of three posts (a glass-fiber, a prefabricated titanium post, and a cast post) and two simulated bone conditions (2 or 6 mm below crown margins). After crown restorations, they were loaded with a 100 N force then the displacements were examined by the digital-image-correlation technique. Marginal integrity on the buccal and lingual crown margins was examined before and after the thermocycling. Finally, the teeth were loaded until failure to examine the strength and fracture patterns. The digital-image-correlation measurements revealed that tooth deformation was related to the support conditions, especially for the fiber post groups. The cast post groups showed less altered marginal integrity after thermomechanical loading than the fiber and titanium post groups did. In the fracture test, the fiber-post/reduced-support group exhibited inferior fracture strength. The reduced support significantly affected fracture strength and incidence of repairable root fracture. The marginal integrity was not correlated with tooth deformation, since the tooth flexed at the crest of the simulated bone. The root fracture resistance was determined mainly by post materials but was concurrently affected by the support conditions.


Asunto(s)
Pérdida de Hueso Alveolar/complicaciones , Biomimética , Diente no Vital/complicaciones , Pérdida de Hueso Alveolar/fisiopatología , Fenómenos Biomecánicos , Humanos , Movimiento , Fracturas de los Dientes , Diente no Vital/fisiopatología
9.
J Mech Behav Biomed Mater ; 4(8): 2138-49, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22098914

RESUMEN

The objective of this study was to examine the effects of cavity configuration on the polymerization shrinkage and stress of light-cured composite restorations by combining local strain measurement and a finite element analysis (FEA). Dental mesio-occluso-distal cavities of various widths and depths (each for 2 vs. 4 mm), representing different configuration factors, were prepared on extracted molars. The displacements of the bonded tooth cusps and cavity floors, caused by polymerization shrinkage of composite restorations, were assessed utilizing a digital-image-correlation (DIC) technique. The cervical marginal microleakage was investigated by examining the resin replicas of these restorations under SEM. The local material properties of the polymerized composite along the curing depth were defined by the nanoindentation test and applied in the subsequent FEA. In the FEA, four models were generated to correspond with the experimental restorations. In the DIC measurement results, the 4(w)×4(D) mm cavity presented the greatest values of inward displacements at the cusp and floor. The cavity depth, rather than the cavity width, was found to significantly correlate to the floor deformation, the location of shrinkage centers, and also the cervical microleakage ratio. The FEA simulation results showed that the 2(w)×4(D) mm cavity presented the maximal von Mises and principal stress located respectively on the cervical margins and cavity floor. Additional safety factor analysis showed a high risk of bond failure over the cavity floor in the 4-mm deep cavity. With the experimental validation, the simulation revealed that the cavity depth was significant to the formation of contraction stress and the incidence of interfacial debonding.


Asunto(s)
Resinas Compuestas/química , Reparación de Restauración Dental/métodos , Análisis de Elementos Finitos , Pruebas de Dureza , Nanotecnología , Polimerizacion , Reproducibilidad de los Resultados , Estrés Mecánico
10.
Cardiol Rev ; 17(4): 192-7, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19525681

RESUMEN

Rivaroxaban is a novel oral direct factor Xa inhibitor. It is currently awaiting approval from the US Food and Drug Administration as a prophylaxis for venous thromboembolism in total knee and hip replacements. Based on phase II and III trials, rivaroxaban has been shown to be as efficacious, if not more, as traditional antithrombotic therapy with similar safety profiles. The Regulation of Coagulation in Major Orthopedic Surgery Reducing the Risk of Deep Vein Thrombosis and Pulmonary Embolism (RECORD) phase III trials have shown rivaroxaban 10 mg once daily to be superior to the low molecular weight heparin, enoxaparin, when used for prophylaxis of venous thromboembolism in orthopedic surgeries. Rivaroxaban has been shown to have tolerable adverse effects and a low potential for drug-drug or drug-food interactions. It has the major advantages of once daily oral dosing and no required laboratory monitoring, giving it the potential to replace current antithrombotics in the market today.


Asunto(s)
Antitrombina III/administración & dosificación , Fibrinolíticos/administración & dosificación , Morfolinas/administración & dosificación , Tiofenos/administración & dosificación , Tromboembolia/prevención & control , Administración Oral , Ensayos Clínicos como Asunto , Humanos , Rivaroxabán
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA