Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 91(5): 3475-3483, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30712341

RESUMEN

Sensitive and high-throughput measurement of biotherapeutics and biomarkers in plasma and tissues is critical for protein-drug development. Enrichment of target signature peptide (SP) after sample digestion permits sensitive LC-MS-based protein quantification and carries several prominent advantages over protein-level enrichment; however, developing high-quality antipeptide antibodies is challenging. Here we describe a novel, antibody-free, peptide-level-enrichment technique enabling high-throughput, sensitive, and robust quantification of proteins in biomatrices, by highly selective removal of matrix peptides and components via cation-exchange (CX) reversed-phase (RP) SPE with strategically regulated pH and ionic and organic strengths. Multiple-mechanism washing and elution achieved highly selective separation despite the low plate number of the SPE cartridge. We first investigated the adsorption-desorption behaviors of peptides on CX-RP sorbent and the coexisting, perplexing effects of pH, and ionic and organic strengths on the selectivity for SP enrichment, which has not been previously characterized. We demonstrated that the selectivity for separating target SPs from matrix peptides was closely associated with buffer pH relative to the pI of the SP, and pH values of pI - 2, pI, and pI + 2 respectively provided exceptional specificity for the ionic wash, the hydrophobic wash, and selective elution. Furthermore, desorption of peptides from the mixed-mode sorbent showed exponential and linear dependence, respectively, on organic-solvent percentage and salt percentage. On the basis of these findings, we established a streamlined procedure for rapid and robust method development. Quantification of biotherapeutics, targets, and biomarkers in plasma and tissues was used as the model system. Selective enrichment of target SPs was achieved along with elimination of 87-95% of matrix peptides, which improved the LOQ by 20-fold (e.g., 2 ng per gram of tissue). Application was demonstrated by sensitive quantification of time courses of mAb (T84.66) and target (CEA) in plasma and tumor tissues from a low-dose mouse PK study. For the first time, down-regulation of membrane-associated antigen following mAb treatment was observed. The CX-RP enrichment is robust, high-throughput, and universally applicable and thus is highly valuable for ultrasensitive, large-scale measurement of target protein in plasma and tissues.


Asunto(s)
Anticuerpos Monoclonales/análisis , Ensayos Analíticos de Alto Rendimiento , Péptidos/química , Animales , Anticuerpos Monoclonales/farmacocinética , Biomarcadores/análisis , Cromatografía Liquida , Concentración de Iones de Hidrógeno , Espectrometría de Masas , Ratones , Concentración Osmolar , Solventes/química
2.
Anal Chem ; 90(3): 1870-1880, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29276835

RESUMEN

For LC-MS-based targeted quantification of biotherapeutics and biomarkers in clinical and pharmaceutical environments, high sensitivity, high throughput, and excellent robustness are all essential but remain challenging. For example, though nano-LC-MS has been employed to enhance analytical sensitivity, it falls short because of its low loading capacity, poor throughput, and low operational robustness. Furthermore, high chemical noise in protein bioanalysis typically limits the sensitivity. Here we describe a novel trapping-micro-LC-MS (T-µLC-MS) strategy for targeted protein bioanalysis, which achieves high sensitivity with exceptional robustness and high throughput. A rapid, high-capacity trapping of biological samples is followed by µLC-MS analysis; dynamic sample trapping and cleanup are performed using pH, column chemistry, and fluid mechanics separate from the µLC-MS analysis, enabling orthogonality, which contributes to the reduction of chemical noise and thus results in improved sensitivity. Typically, the selective-trapping and -delivery approach strategically removes >85% of the matrix peptides and detrimental components, markedly enhancing sensitivity, throughput, and operational robustness, and narrow-window-isolation selected-reaction monitoring further improves the signal-to-noise ratio. In addition, unique LC-hardware setups and flow approaches eliminate gradient shock and achieve effective peak compression, enabling highly sensitive analyses of plasma or tissue samples without band broadening. In this study, the quantification of 10 biotherapeutics and biomarkers in plasma and tissues was employed for method development. As observed, a significant sensitivity gain (up to 25-fold) compared with that of conventional LC-MS was achieved, although the average run time was only 8 min/sample. No appreciable peak deterioration or loss of sensitivity was observed after >1500 injections of tissue and plasma samples. The developed method enabled, for the first time, ultrasensitive LC-MS quantification of low levels of a monoclonal antibody and antigen in a tumor and cardiac troponin I in plasma after brief cardiac ischemia. This strategy is valuable when highly sensitive protein quantification in large sample sets is required, as is often the case in typical biomarker validation and pharmaceutical investigations of antibody therapeutics.


Asunto(s)
Cromatografía Liquida/instrumentación , Ensayos Analíticos de Alto Rendimiento/instrumentación , Espectrometría de Masas/instrumentación , Péptidos/análisis , Proteínas/análisis , Secuencia de Aminoácidos , Animales , Anticuerpos Monoclonales/análisis , Biomarcadores/análisis , Cromatografía Liquida/economía , Cromatografía Liquida/métodos , Diseño de Equipo , Ensayos Analíticos de Alto Rendimiento/economía , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Inmunoglobulina G/análisis , Límite de Detección , Espectrometría de Masas/economía , Espectrometría de Masas/métodos , Ratones , Ratas , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA