Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int Orthop ; 47(9): 2245-2251, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37188902

RESUMEN

PURPOSE: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head-neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. MATERIALS AND METHODS: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head-neck metal adapter was used. The preoperative and one year follow-up modified Merle d'Aubigné hip score was used to evaluate functional outcomes. RESULTS: Of a total of 34 cases included for revision, the head-neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0-9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d'Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. CONCLUSION: The use of a head-neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Fémur/cirugía , Acetábulo/cirugía , Reoperación , Falla de Prótesis
2.
Int Orthop ; 46(12): 2793-2798, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35951099

RESUMEN

PURPOSE: We hypothesized that the intra-operative measurement of the femoral head may increase the accuracy of the acetabular cup size optimal selection in total hip arthroplasty (THA). The purpose of this clinical research was to analyze the correlation between the estimated cup size from intra-operative measurement of the femoral head and the pre-operative templated cup size. METHODS: A prospective observational single-center study was conducted from June 2019 to January 2020 including primary THA (n = 100). All cases were pre-operatively templated. The measurement of the anterior-posterior diameter of the femoral head was routinely intra-operatively performed. Any definitive implanted cup was considered as "oversized" when the size was > 4 mm than the diameter of the native head. RESULTS: The median (interquartile range) size of the implanted cup, pre-operative planned cup size, and diameter of the femoral head were measured 52 (50-54) mm, 50 (48-54) mm and 49 (45-51) mm, respectively. Pre-operative planned size cup accurately predicted the implanted cup or differed in only one size (2 mm) in 77 (78%) cases. Otherwise, intra-operative femoral head measurement method accurately predicted the implanted or differed in only one size (2 mm) in 51 (87%) cases (p = 0.097). CONCLUSION: The intra-operative femoral head measurement is a simple and reliable tool to help the surgeons choose the best size of the acetabular cup and is as reliable as the pre-operative templating in order to avoid cup oversizing in THA. Utmost caution is warranted whenever the cup reamer is > 4 mm than the anterior-posterior diameter of the native head.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cirujanos , Humanos , Cabeza Femoral/cirugía , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA