1.
J Appl Clin Med Phys ; 15(3): 4742, 2014 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-24892351

RESUMEN

As part of the approval process for the use of scattered or uniform scanning proton therapy in National Cancer Institute (NCI)-sponsored clinical trials, the Radiological Physics Center (RPC) mandates irradiation of two RPC anthropomorphic proton phantoms (prostate and spine). The RPC evaluates these irradiations to ensure that they agree with the institutions' treatment plans within criteria of the NCI-funded cooperative study groups. The purpose of this study was to evaluate the use of an anthropomorphic spine phantom for proton matched-field irradiation, and to assess its use as a credentialing tool for proton therapy beams. We used an anthropomorphic spine phantom made of human vertebral bodies embedded in a tissue substitute material called Muscle Substitute/Solid Rigid Number 4 (MS/SR4) comprising three sections: a posterior section containing the posterior surface and the spinous processes, and left and right (L/R) sections containing the vertebral bodies and the transverse processes. After feasibility studies at three institutions, the phantom, containing two thermoluminescent dosimeters (TLDs) for absolute dose measurements and two sheets of radiochromic film for relative dosimetry, was shipped consecutively to eight proton therapy centers participating in the approval study. At each center, the phantom was placed in a supine or prone position (according to the institution's spine treatment protocol) and imaged with computed tomography (CT). The images then were used with the institution's treatment planning system (TPS) to generate two matched fields, and the phantom was irradiated accordingly. The irradiated phantom was shipped to the RPC for analysis, and the measured values were compared with the institution's TPS dose and profiles using criteria of ± 7% for dose agreement and 5 mm for profile distance to agreement. All proton centers passed the dose criterion with a mean agreement of 3% (maximum observed agreement, 7%). One center failed the profile distance-to-agreement criterion on its initial irradiation, but its second irradiation passed the criterion. Another center failed the profile distance-to-agreement criterion, but no repeat irradiation was performed. Thus, seven of the eight institutions passed the film profile distance-to-agreement criterion with a mean agreement of 1.2 mm (maximum observed agreement 5 mm). We conclude that an anthropomorphic spine phantom using TLD and radiochromic film adequately verified dose delivery and field placement for matched-field treatments.


Asunto(s)
Materiales Biomiméticos/normas , Ensayos Clínicos como Asunto/instrumentación , Radiometría/instrumentación , Radiometría/normas , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/normas , Columna Vertebral/efectos de la radiación , Antropometría/instrumentación , Materiales Biomiméticos/economía , Ensayos Clínicos como Asunto/economía , Ensayos Clínicos como Asunto/normas , Aprobación de Recursos/normas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , National Cancer Institute (U.S.)/economía , National Cancer Institute (U.S.)/normas , Terapia de Protones , Radiometría/economía , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
2.
Phys Med Biol ; 54(16): N367-74, 2009 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-19636083

RESUMEN

Electron monitor unit (MU) calculation requires measured beam data such as the relative output factor (ROF) of a cone, insert correction factor (ICF) and effective source-to-surface distance (ESD). Measuring the beam data to cover all possible clinical cases is not practical for a busy clinic because it takes tremendous time and labor. In this study, we propose a practical approach to reduce the number of data measurements without affecting accuracy. It is based on two findings of dosimetric properties of electron beams. One is that the output ratio of two inserts is independent of the cone used, and the other is that ESD is a function of field size but independent of cone and jaw opening. For the measurements to prove the findings, a parallel plate ion chamber (Markus, PTW 23343) with an electrometer (Cardinal Health 35040) was used. We measured the outputs to determine ROF, ICF and ESD of different energies (5-21 MeV). Measurements were made in a Plastic Water phantom or in water. Three linear accelerators were used: Siemens MD2 (S/N 2689), Siemens Primus (S/N 3305) and Varian Clinic 21-EX (S/N 1495). With these findings, the number of data set to be measured can be reduced to less than 20% of the data points.


Asunto(s)
Electrones , Radiometría/métodos , Agua
3.
Med Phys ; 44(5): 1734-1746, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28273345

RESUMEN

PURPOSE: While positron emission tomography (PET) allows for the imaging of tissues activated by proton beams in terms of monitoring the therapy administered, most endogenous tissue elements are activated by relatively high-energy protons. Therefore, a relatively large distance off-set exists between the dose fall-off and activity fall-off. However, 16 O(p,2p,2n)13 N has a relatively low energy threshold which peaks around 12 MeV and also a residual proton range that is approximately 1 to 2 mm. In this phantom study, we tested the feasibility of utilizing the 13 N production peak as well as the differences in activity fall-off between early and late PET scans for proton range verification. One of the main purposes for this research was developing a proton range verification methodology that would not require Monte Carlo simulations. METHODS AND MATERIALS: Both monoenergetic and spread-out Bragg peak beams were delivered to two phantoms - a water-like gel and a tissue-like gel where the proton ranges came to be approximately 9.9 and 9.1 cm, respectively. After 1 min of postirradiation delay, the phantoms were scanned for a period of 30 min using an in-room PET. Two separate (Early and Late) PET images were reconstructed using two different postirradiation delays and acquisition times; Early PET: 1 min delay and 3 min acquisition, Late PET: 21 min delay and 10 min acquisition. The depth gradients of the PET signals were then normalized and plotted as functions of depth. The normalized gradient of the early PET images was subtracted from that of the late PET images, to observe the 13 N activity distribution in relation to depth. Monte Carlo simulations were also conducted with the same set-up as the measurements stated previously. RESULTS: The subtracted gradients show peaks at 9.4 and 8.6 cm in water-gel and tissue-gel respectively for both pristine and SOBP beams. These peaks are created in connection with the sudden change of 13 N signals with depth and consistently occur 2 mm upstream to where 13 N signals were most abundantly created (9.6 and 8.8 cm in water-gel and tissue-gel, respectively). Monte Carlo simulations provided similar results as the measurements. CONCLUSIONS: The subtracted PET signal gradient peaks and the proton ranges for water-gel and tissue-gel show distance off-sets of 4 to 5 mm. This off-set may potentially be used for proton range verification using only the PET measured data without Monte Carlo simulations. More studies are necessary to overcome various limitations, such as perfusion-driven washout, for the feasibility of this technique in living patients.


Asunto(s)
Fantasmas de Imagen , Tomografía de Emisión de Positrones , Protones , Estudios de Factibilidad , Humanos , Método de Montecarlo
4.
Sci Rep ; 7(1): 18044, 2017 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-29273727

RESUMEN

Theoretical investigations suggest that gold nanoparticle (GNP)-mediated radiation dose enhancement and radiosensitization can be maximized when photons interact with gold, predominantly via photoelectric absorption. This makes ytterbium (Yb)-169, which emits photons with an average energy of 93 keV (just above the K-edge of gold), an ideal radioisotope for such purposes. This investigation tests the feasibility of tumor-specific prostate brachytherapy achievable with Yb-169 and actively targeted GNPs, using an external beam surrogate of Yb-169 created from an exotic filter material - erbium (Er) and a standard copper-filtered 250 kVp beam. The current in vitro study shows that treatment of prostate cancer cells with goserelin-conjugated gold nanorods (gGNRs) promotes gonadotropin releasing hormone receptor-mediated internalization and enhances radiosensitivity to both Er-filtered and standard 250 kVp beams, 14 and 10%, respectively. While the degree of GNP-mediated radiosensitization as seen from the in vitro study may be considered moderate, the current in vivo study shows that gGNR treatment plus Er-filtered x-ray irradiation is considerably more effective than radiation treatment alone (p < 0.0005), resulting in a striking reduction in tumor volume (50% smaller) 2 months following treatment. Overall, the current results provide strong evidence for the feasibility of tumor-specific prostate brachytherapy with Yb-169 and gGNRs.


Asunto(s)
Braquiterapia/métodos , Oro/uso terapéutico , Nanopartículas del Metal/uso terapéutico , Próstata/efectos de la radiación , Neoplasias de la Próstata/radioterapia , Fármacos Sensibilizantes a Radiaciones/uso terapéutico , Animales , Erbio , Oro/administración & dosificación , Humanos , Masculino , Nanopartículas del Metal/administración & dosificación , Ratones , Ratones Desnudos , Células PC-3 , Próstata/patología , Neoplasias de la Próstata/patología , Fármacos Sensibilizantes a Radiaciones/administración & dosificación , Rayos X
5.
Med Phys ; 43(8): 4775, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27487895

RESUMEN

PURPOSE: Gold nanoparticles (GNPs) are being investigated actively for various applications in cancer diagnosis and therapy. As an effort to improve the imaging of GNPs in vivo, the authors developed bimetallic hybrid Zn@Au NPs with zinc cores and gold shells, aiming to render them in vivo visibility through positron emission tomography (PET) after the proton activation of the zinc core as well as capability to induce radiosensitization through the secondary electrons produced from the gold shell when irradiated by various radiation sources. METHODS: Nearly spherical zinc NPs (∼5-nm diameter) were synthesized and then coated with a ∼4.25-nm gold layer to make Zn@Au NPs (∼13.5-nm total diameter). 28.6 mg of these Zn@Au NPs was deposited (∼100 µm thick) on a thin cellulose target and placed in an aluminum target holder and subsequently irradiated with 14.15-MeV protons from a GE PETtrace cyclotron with 5-µA current for 5 min. After irradiation, the cellulose matrix with the NPs was placed in a dose calibrator to assess the induced radioactivity. The same procedure was repeated with 8-MeV protons. Gamma ray spectroscopy using an high-purity germanium detector was conducted on a very small fraction (<1 mg) of the irradiated NPs for each proton energy. In addition to experimental measurements, Monte Carlo simulations were also performed with radioactive Zn@Au NPs and solid GNPs of the same size irradiated with 160-MeV protons and 250-kVp x-rays. RESULTS: The authors measured 168 µCi of activity 32 min after the end of bombardment for the 14.15-MeV proton energy sample using the (66)Ga setting on a dose calibrator; activity decreased to 2 µCi over a 24-h period. For the 8-MeV proton energy sample, PET imaging was additionally performed for 5 min after a 12-h delay. A 12-h gamma ray spectrum showed strong peaks at 511 keV (2.05 × 10(6) counts) with several other peaks of smaller magnitude for each proton energy sample. PET imaging showed strong PET signals from mostly decaying (66)Ga. The Monte Carlo results showed that radioactive Zn@Au NPs and solid GNPs provided similar characteristics in terms of their secondary electron spectra when irradiated. CONCLUSIONS: The Zn@Au NPs developed in this investigation have the potential to be used as PET-imageable radiosensitizers for radiotherapy applications as well as PET tracers for molecular imaging applications.


Asunto(s)
Oro/química , Nanopartículas del Metal , Tomografía de Emisión de Positrones , Fármacos Sensibilizantes a Radiaciones , Zinc/química , Electrones , Rayos gamma , Método de Montecarlo , Protones
6.
Phys Med Biol ; 61(6): 2562-81, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-26952844

RESUMEN

Some investigators have shown tumor cell killing enhancement in vitro and tumor regression in mice associated with the loading of gold nanoparticles (GNPs) before proton treatments. Several Monte Carlo (MC) investigations have also demonstrated GNP-mediated proton dose enhancement. However, further studies need to be done to quantify the individual physical factors that contribute to the dose enhancement or cell-kill enhancement (or radiosensitization). Thus, the current study investigated the contributions of particle-induced x-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), Auger and secondary electrons, and activation products towards the total dose enhancement. Specifically, GNP-mediated dose enhancement was measured using strips of radiochromic film that were inserted into vials of cylindrical GNPs, i.e. gold nanorods (GNRs), dispersed in a saline solution (0.3 mg of GNRs/g or 0.03% of GNRs by weight), as well as vials containing water only, before proton irradiation. MC simulations were also performed with the tool for particle simulation code using the film measurement setup. Additionally, a high-purity germanium detector system was used to measure the photon spectrum originating from activation products created from the interaction of protons and spherical GNPs present in a saline solution (20 mg of GNPs/g or 2% of GNPs by weight). The dose enhancement due to PIXE/PIGE recorded on the films in the GNR-loaded saline solution was less than the experimental uncertainty of the film dosimetry (<2%). MC simulations showed highly localized dose enhancement (up to a factor 17) in the immediate vicinity (<100 nm) of GNRs, compared with hypothetical water nanorods (WNRs), mostly due to GNR-originated Auger/secondary electrons; however, the average dose enhancement over the entire GNR-loaded vial was found to be minimal (0.1%). The dose enhancement due to the activation products from GNPs was minimal (<0.1%) as well. In conclusion, under the currently investigated conditions that are considered clinically relevant, PIXE, PIGE, and activation products contribute minimally to GNP/GNR-mediated proton dose enhancement, whereas Auger/secondary electrons contribute significantly but only at short distances (<100 nm) from GNPs/GNRs.


Asunto(s)
Rayos gamma , Nanopartículas del Metal/efectos de la radiación , Terapia de Protones/métodos , Protones , Dosis de Radiación , Rayos X , Algoritmos , Animales , Oro/efectos de la radiación , Nanopartículas del Metal/química , Nanopartículas del Metal/uso terapéutico , Ratones
7.
Phys Med Biol ; 61(5): 2162-76, 2016 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-26907591

RESUMEN

Biocompatible/biodegradable hydrogel polymers were immersed in 18O-enriched water and 16O-water to create 18O-water hydrogels and 16O-water hydrogels. In both cases, the hydrogels were made of ~91 wt% water and ~9 wt% polymer. In addition, 5-8 µm Zn powder was suspended in 16O-water and 18O-enriched water and cross-linked with hydrogel polymers to create Zn/16O-water hydrogels (30/70 wt%, ~9 wt% polymer) and Zn/18O-water hydrogels (10/90 wt%), respectively. A block of extra-firm 'wet' tofu (12.3 × 8.8 × 4.9 cm, ρ ≈ 1.05 g cm−3) immersed in water was injected with Zn/16O-water hydrogels (0.9 ml each) at four different depths using an 18-gauge needle. Similarly, Zn/18O-water hydrogels (0.9 ml) were injected into a second tofu phantom. As a reference, both 16O-water hydrogels (1.8 ml) and 18O-water hydrogels (0.9 ml) in Petri dishes were irradiated in a 'dry' environment. The hydrogels in the wet tofu phantoms and dry Petri dishes were scanned via CT and images were used for treatment planning. Then, they were positioned at the proton distal dose fall-off region and irradiated (2 Gy) followed by PET/CT imaging.Notably high PET signals were observed only in 18O-water hydrogels in the dry environment. The visibility of the Zn/16O-water hydrogels injected into the tofu phantom was outstanding in CT images, but these hydrogels provided no noticeable PET signals. The visibility of the Zn/18O-water hydrogels in the wet tofu were excellent on CT and moderate on PET; however, the PET signals were weaker than those in the dry environment, possibly owing to 18O-water leaching out. The hydrogel markers studied here could be used to develop universal PET/CT fiducial markers. Their PET visibility (attributed more to activated 18O-water than Zn) after proton irradiation can be used for proton therapy/range verification. More investigation is needed to slow down the leaching of 18O-water.


Asunto(s)
Marcadores Fiduciales/efectos adversos , Hidrogeles/química , Tomografía de Emisión de Positrones/métodos , Protones , Hidrogeles/efectos de la radiación , Isótopos de Oxígeno
8.
Phys Med Biol ; 61(11): N291-310, 2016 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-27203621

RESUMEN

Conventional proton beam range verification using positron emission tomography (PET) relies on tissue activation alone and therefore requires particle therapy PET whose installation can represent a large financial burden for many centers. Previously, we showed the feasibility of developing patient implantable markers using high proton cross-section materials ((18)O, Cu, and (68)Zn) for in vivo proton range verification using conventional PET scanners. In this technical note, we characterize those materials to test their usability in more clinically relevant conditions. Two phantoms made of low-density balsa wood (~0.1 g cm(-3)) and beef (~1.0 g cm(-3)) were embedded with Cu or (68)Zn foils of several volumes (10-50 mm(3)). The metal foils were positioned at several depths in the dose fall-off region, which had been determined from our previous study. The phantoms were then irradiated with different proton doses (1-5 Gy). After irradiation, the phantoms with the embedded foils were moved to a diagnostic PET scanner and imaged. The acquired data were reconstructed with 20-40 min of scan time using various delay times (30-150 min) to determine the maximum contrast-to-noise ratio. The resultant PET/computed tomography (CT) fusion images of the activated foils were then examined and the foils' PET signal strength/visibility was scored on a 5 point scale by 13 radiologists experienced in nuclear medicine. For both phantoms, the visibility of activated foils increased in proportion to the foil volume, dose, and PET scan time. A linear model was constructed with visibility scores as the response variable and all other factors (marker material, phantom material, dose, and PET scan time) as covariates. Using the linear model, volumes of foils that provided adequate visibility (score 3) were determined for each dose and PET scan time. The foil volumes that were determined will be used as a guideline in developing practical implantable markers.


Asunto(s)
Marcadores Fiduciales , Tomografía de Emisión de Positrones , Terapia de Protones , Radioterapia Guiada por Imagen/normas , Humanos , Metales , Fantasmas de Imagen , Prótesis e Implantes
9.
Phys Med Biol ; 58(21): 7497-512, 2013 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-24099853

RESUMEN

Proton beam range verification using positron emission tomography (PET) currently relies on proton activation of tissue, the products of which decay with a short half-life and necessitate an on-site PET scanner. Tissue activation is, however, negligible near the distal dose fall-off region of the proton beam range due to their high interaction energy thresholds. Therefore Monte Carlo simulation is often supplemented for comparison with measurement; however, this also may be associated with systematic and statistical uncertainties. Therefore, we sought to test the feasibility of using long-lived proton-activated external materials that are inserted or infused into the target volume for more accurate proton beam range verification that could be performed at an off-site PET scanner. We irradiated samples of ≥98% (18)O-enriched water, natural Cu foils, and >97% (68)Zn-enriched foils as candidate materials, along with samples of tissue-equivalent materials including (16)O water, heptane (C7H16), and polycarbonate (C16H14O3)n, at four depths (ranging from 100% to 3% of center of modulation (COM) dose) along the distal fall-off of a modulated 160 MeV proton beam. Samples were irradiated either directly or after being embedded in Plastic Water® or balsa wood. We then measured the activity of the samples using PET imaging for 20 or 30 min after various delay times. Measured activities of candidate materials were up to 100 times greater than those of the tissue-equivalent materials at the four distal dose fall-off depths. The differences between candidate materials and tissue-equivalent materials became more apparent after longer delays between irradiation and PET imaging, due to the longer half-lives of the candidate materials. Furthermore, the activation of the candidate materials closely mimicked the distal dose fall-off with offsets of 1 to 2 mm. Also, signals from the foils were clearly visible compared to the background from the activated Plastic Water® and balsa wood phantoms. These results indicate that markers made from these candidate materials could be used for in vivo proton range verification using an off-site PET scanner.


Asunto(s)
Marcadores Fiduciales , Tomografía de Emisión de Positrones/normas , Terapia de Protones/instrumentación , Radioterapia Guiada por Imagen/normas , Estudios de Factibilidad , Fantasmas de Imagen
10.
Phys Med Biol ; 58(11): 3815-35, 2013 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-23681070

RESUMEN

Positron emission tomography (PET) has been suggested as an imaging technique for in vivo proton dose and range verification after proton induced-tissue activation. During proton treatment, irradiated tissue is activated and decays while emitting positrons. In this paper, we assessed the feasibility of using PET imaging after proton treatment to determine tissue elemental composition by evaluating the resultant composite decay curve of activated tissue. A phantom consisting of sections composed of different combinations of (1)H, (12)C, (14)N, and (16)O was irradiated using a pristine Bragg peak and a 6 cm spread-out Bragg-peak (SOBP) proton beam. The beam ranges defined at 90% distal dose were 10 cm; the delivered dose was 1.6 Gy for the near monoenergetic beam and 2 Gy for the SOBP beam. After irradiation, activated phantom decay was measured using an in-room PET scanner for 30 min in list mode. Decay curves from the activated (12)C and (16)O sections were first decomposed into multiple simple exponential decay curves, each curve corresponding to a constituent radioisotope, using a least-squares method. The relative radioisotope fractions from each section were determined. These fractions were used to guide the decay curve decomposition from the section consisting mainly of (12)C + (16)O and calculate the relative elemental composition of (12)C and (16)O. A Monte Carlo simulation was also used to determine the elemental composition of the (12)C + (16)O section. The calculated compositions of the (12)C + (16)O section using both approaches (PET and Monte Carlo) were compared with the true known phantom composition. Finally, two patients were imaged using an in-room PET scanner after proton therapy of the head. Their PET data and the technique described above were used to construct elemental composition ((12)C and (16)O) maps that corresponded to the proton-activated regions. We compared the (12)C and (16)O compositions of seven ROIs that corresponded to the vitreous humor, adipose/face mask, adipose tissue, and brain tissue with ICRU 46 elemental composition data. The (12)C and (16)O compositions of the (12)C + (16)O phantom section were estimated to within a maximum difference of 3.6% for the near monoenergetic and SOBP beams over an 8 cm depth range. On the other hand, the Monte Carlo simulation estimated the corresponding (12)C and (16)O compositions in the (12)C + (16)O section to within a maximum difference of 3.4%. For the patients, the (12)C and (16)O compositions in the seven ROIs agreed with the ICRU elemental composition data, with a mean (maximum) difference of 9.4% (15.2%). The (12)C and (16)O compositions of the phantom and patients were estimated with relatively small differences. PET imaging may be useful for determining the tissue elemental composition and thereby improving proton treatment planning and verification.


Asunto(s)
Tomografía de Emisión de Positrones , Terapia de Protones , Estudios de Factibilidad , Humanos , Método de Montecarlo , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador