Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pacing Clin Electrophysiol ; 45(1): 103-110, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34727374

RESUMEN

BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios Retrospectivos
3.
Open Heart ; 9(2)2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35790318

RESUMEN

OBJECTIVES: This study evaluates predictors of conduction abnormalities (CA) following transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valves (BAV). BACKGROUND: TAVI is associated with CA that commonly necessitate a permanent pacemaker. Predictors of CA are well established among patients with tricuspid aortic valves but not in those with BAV. METHODS: This is a single-centre, retrospective, observational study of patients with BAV treated with TAVI. Pre-TAVI ECG and CT scans and procedural characteristics were evaluated in 58 patients with BAV. CA were defined as a composite of high-degree atrioventricular block, new left bundle branch block with a QRS >150 ms or PR >240 ms and right bundle branch block with new PR prolongation or change in axis. Predictors of CA were identified using regression analysis and optimum cut-off values determined using area under the receiver operating characteristic curve analysis. RESULTS: CA occurred in 35% of patients. Bioprosthesis implantation depth, the difference between membranous septum (MS) length and implantation depth (δMSID) and device landing zone (DLZ) calcification adjacent to the MS were identified as univariate predictors of CA. The optimum cut-off for δMSID was 1.25 mm. Using this cut-off, low δMSID and DLZ calcification adjacent to MS predicted CA, adjusted OR 8.79, 95% CI 1.88 to 41.00; p=0.01. Eccentricity of the aortic valve annulus, type of BAV and valve calcium quantity and distribution did not predict CA. CONCLUSIONS: In BAV patients undergoing TAVI, short δMSID and DLZ calcification adjacent to MS are associated with an increased risk of CA.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Reemplazo de la Válvula Aórtica Transcatéter , Bloqueo de Rama , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
4.
Arrhythm Electrophysiol Rev ; 10(2): 91-100, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34401181

RESUMEN

Despite advances in the field of cardiac resynchronisation therapy (CRT), response rates and durability of therapy remain relatively static. Optimising device timing intervals may be the most common modifiable factor influencing CRT efficacy after implantation. This review addresses the concept of fusion pacing as a method for improving patient outcomes with CRT. Fusion pacing describes the delivery of CRT pacing with a programming strategy to preserve intrinsic atrioventricular (AV) conduction and ventricular activation via the right bundle branch. Several methods have been assessed to achieve fusion pacing. QRS complex duration (QRSd) shortening with CRT is associated with improved clinical response. Dynamic algorithm-based optimisation targeting narrowest QRSd in patients with intact AV conduction has shown promise in people with heart failure with left bundle branch block. Individualised dynamic programming achieving fusion may achieve the greatest magnitude of electrical synchrony, measured by QRSd narrowing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA