Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 29(5): 1067-71, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24295802

RESUMEN

In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available. We investigated the torque to periprosthetic femoral fracture of the Exeter short stem compared with the conventional length Exeter stem in a Sawbone model. Forty-two stems; 21 shorter and 21 conventional stems both with three different offsets were cemented in a composite Sawbone model and torqued to fracture. Results showed that Sawbone femurs break at a statistically significantly lower torque to failure with a shorter compared to conventional-length Exeter stem of the same offset. Both standard and short-stem designs are safe to use as the torque to failure is 7-10 times that seen in activities of daily living.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera , Fracturas Periprotésicas/fisiopatología , Diseño de Prótesis , Cementación , Fémur/cirugía , Humanos , Modelos Anatómicos , Fracturas Periprotésicas/etiología , Torque
2.
J Arthroplasty ; 28(1): 103-9.e1, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23040643

RESUMEN

The standard Exeter stem has a length of 150 mm with offsets 37.5 to 56 mm. Shorter stems of lengths 95, 115 and 125 mm with offsets 35.5 mm or less are available for patients with smaller femurs. Concern has been raised regarding the behavior of the smaller implants. This paper analyzed data from the Australian Orthopaedic Association National Joint Replacement Registry comparing survivorship of stems of offset 35.5 mm or less with the standard stems of 37.5 mm offset or greater. At 7 years, there was no significant difference in the cumulative percent revision rate in the short stems (3.4%, 95% CI 2.4-4.8%) compared with the standard length stems (3.5%, 95% CI 3.3-3.8%) despite its use in a greater proportion of potentially more difficult developmental dysplasia of the hip cases.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Humanos , Estimación de Kaplan-Meier , Osteoartritis de la Cadera/cirugía , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación
3.
J Orthop Surg (Hong Kong) ; 22(2): 163-7, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25163947

RESUMEN

PURPOSE: To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. METHODS: Two groups of 5 synthetic femurs were used, and 6 pressure sensors were placed in the femur at 20-mm intervals proximally to distally. Cement was filled into the femoral canal retrogradely using a cement gun with either the half-moon pressuriser or the femoral canal pressuriser. Maximum pressures and pressure time integrals (cumulative pressure over time) of the 2 pressurisers were compared. RESULTS: At all sensors, the half-moon pressuriser produced higher maximum pressures and pressure time integrals than the femoral canal pressuriser, but the difference was significant only at sensor 1 (proximal femur). This may result in reduced cement interdigitation in the proximal femur. CONCLUSION: The half-moon pressuriser produced higher maximum cementation pressures and pressure time integrals than the femoral canal pressuriser in the proximal femur region, which is critical for rotational stability of the implant and prevention of implant fracture.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementación/instrumentación , Fémur/cirugía , Prótesis de Cadera , Presión , Humanos , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA