Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
JACC Clin Electrophysiol ; 5(8): 935-943, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31439295

RESUMEN

OBJECTIVES: A prospective, multicenter study was performed to assess the safety and efficacy of the Durata and Optisure HV leads and the Ellipse VR implantable cardioverter-defibrillator (ICD) (St. Jude Medical, Sylmar, California) in a 1.5-T magnetic resonance imaging (MRI) environment. The primary safety objective was >90% freedom from MRI scan-related complications. The primary efficacy objectives were absence of change in capture threshold and absence of decrease of sensing amplitude from pre-MRI examination to 1 month after MRI. BACKGROUND: MRI scanning of patients has been shown to be safe in patients with magnetic resonance-conditional implantable cardioverter-defibrillators (ICD) systems. METHODS: Patients with a previously implanted magnetic resonance-conditional system underwent a nondiagnostic MRI scan. After the scan, a questionnaire was given to investigators and patients who returned for 1-month follow-up examination. A subset of patients underwent ventricular tachyarrhythmia or ventricular fibrillation (VT/VF) induction testing after the MRI to evaluate defibrillation function. RESULTS: There were 220 patients (81% male; 62.1 ± 11.2 years of age) enrolled who received an MRI scans from 29 centers. All primary safety and efficacy endpoints were met (p < 0.0001). No significant detection delays were found in 34 patients who had VT/VF episodes after the MRI scan was performed. Most physicians reported easy and acceptable programming and ease of MRI scheduling. CONCLUSIONS: The MRI Ready MRI-conditional ICD system is safe, and electrical performance was not affected in patients receiving a 1.5-T whole-body MRI scan. Investigators reported favorable collaboration between cardiologists and radiologists in the MRI Ready IDE clinical trial. (A Clinical Evaluation of the Durata or Optisure High Voltage Leads and Ellipse VR ICD Undergoing MRI, an IDE Study [MRI Ready IDE]; NCT02787291).


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética , Seguridad del Paciente , Adulto , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/normas , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Estudios Prospectivos
2.
Ann Thorac Surg ; 94(2): 429-33; discussion 434-5, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22762940

RESUMEN

BACKGROUND: Laparoscopic Nissen fundoplication is a common operation performed for reflux disease, generally with good results. A small percentage of patients experience transthoracic migration of the wrap, causing recurrent symptoms and eventually requiring transthoracic repair. METHODS: A retrospective chart review was performed for all patients who underwent a transthoracic repair of a slipped Nissen fundoplication at our institution from 2006 to 2010. Data included demographics, previous antireflux operations, symptoms at presentation, findings at operation, and overall outcome. RESULTS: Sixteen patients with a mean age of 61 years (range, 51-76 years) were identified who fit inclusion criteria. The most common presenting symptom was pain. Intraoperative findings included hiatal breakdown in all patients, shortened esophagus in 10 (62%) patients, and foreign body/mesh in 4 (25%) patients. Nine (56%) patients underwent a Collis gastroplasty along with a Nissen fundoplication. Nissen fundoplication alone was performed in 6 (38%) patients and a Belsey fundoplication with a Collis gastroplasty was performed in 1 (6%) patient. Minor complications occurred in 4 (25%) patients and major complications were seen in 2 (13%) patients. The median length of stay was 9 days (range, 6-30 days). There were no postoperative deaths. Overall, 12 (75%) of the patients were judged to have a good outcome, 3 (19%) a fair outcome, and 1 (6%) a poor outcome over a median 9-month follow-up. CONCLUSIONS: Transthoracic repair in patients who have had transthoracic migration of a previous Nissen fundoplication has acceptable surgical outcome and affords symptomatic relief to the majority of patients.


Asunto(s)
Migración de Cuerpo Extraño/cirugía , Fundoplicación/efectos adversos , Fundoplicación/instrumentación , Anciano , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Procedimientos Quirúrgicos Torácicos/métodos , Insuficiencia del Tratamiento
3.
Am J Surg ; 204(5): e15-20, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22902101

RESUMEN

BACKGROUND: Video-assisted thoracoscopic surgery (VATS) pulmonary lobectomy has been associated with decreased complication rates and length of stay compared with lobectomy by thoracotomy. No studies have addressed VATS lobectomy in Veterans Administration (VA) patients. METHODS: A retrospective review was undertaken of 50 VATS lobectomies performed between August 2007 and June 2009 by one surgeon in a VA hospital, a university-affiliated county hospital, and a private community hospital. RESULTS: VA patients had more medical comorbidities, poorer lung function, greater current smoker status, and fewer preoperative biopsies. Pleural adhesions or hilar lymphadenopathy were encountered more commonly in VA than nonfederal patients. Surgical times and number of procedures performed were greater in VA patients. There was no statistically significant difference in the risk of postoperative complications or chest tube duration although length of stay was longer for VA patients. CONCLUSIONS: VATS lobectomy is feasible in a VA setting. The evidence strongly suggests that veterans can benefit from VATS lobectomy in terms of improved outcomes and diminished length of stay compared with thoracotomy.


Asunto(s)
Neoplasias Pulmonares/cirugía , Neumonectomía/métodos , Cirugía Torácica Asistida por Video , Salud de los Veteranos/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Hospitales Comunitarios , Hospitales de Condado , Hospitales Privados , Hospitales Universitarios , Hospitales de Veteranos , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias , Estudios Retrospectivos , Texas , Resultado del Tratamiento , Estados Unidos , United States Department of Veterans Affairs
4.
J Invest Surg ; 23(4): 197-203, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20690844

RESUMEN

OBJECTIVE: To characterize a new method of postoperative gastrointestinal leak detection based on electrical resistance changes due to extravasated electrolyte contrast. BACKGROUND: Postoperative gastrointestinal leak results in increased patient morbidity, mortality, and hospital costs that can be mitigated by early diagnosis. A sensitive and specific diagnostic test that could be performed at the bedside has the potential to shorten the time to diagnosis and thereby improve the quality of treatment. MATERIALS AND METHODS: Anaesthetized rats underwent celiotomy and creation of a 5-mm gastrotomy. In experimental animals, electrical resistance changes were measured with a direct current ohmmeter after the introduction of 5 cc of 23.4% NaCl electrolyte solution via gavage and measured with a more sensitive alternating current ohmmeter after the gavage of 1-5 cc of 0.9% NaCl. Comparison was made to negative controls and statistical analysis was performed. RESULTS: Leakage from the gastrotomy induced by as little as 1 cc of gavage-delivered 0.9% NaCl contrast solution was detectable as a statistically significant drop in electrical resistance when compared to results from negative controls. CONCLUSION: Electrical resistance change associated with electrolyte-gated leak detection is highly sensitive and specific and has the potential to be rapidly translated into clinical settings.


Asunto(s)
Fuga Anastomótica/diagnóstico , Impedancia Eléctrica , Electrólitos , Cloruro de Sodio , Anastomosis Quirúrgica , Animales , Extravasación de Materiales Terapéuticos y Diagnósticos , Modelos Animales , Complicaciones Posoperatorias , Ratas , Ratas Endogámicas BN , Sensibilidad y Especificidad
5.
Int J Pharm ; 384(1-2): 46-52, 2010 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19782740

RESUMEN

Lung transplantation animal models have been well established and enabled the investigation of a variety of new pharmacotherapeutic strategies for prevention of lung allograft rejection. Direct administration of immunosuppressive agents to the lung is a commonly investigated approach; however, can prove challenging due to the poor solubility of the drug molecule, the tortuous pathways of the lung periphery, and the limited number of excipients approved for inhalation. In this study, we aimed to evaluate a solubility enhancing formulation of tacrolimus for localized therapy in a lung transplanted rat model and determine the extent of drug absorption into systemic circulation. Characterization of the nebulized tacrolimus dispersion for nebulization showed a fine particle fraction (FPF) of 46.1% and a mass median aerodynamic diameter (MMAD) of 4.06 microm. After single dose administration to transplanted and non-transplanted rats, a mean peak transplanted lung concentration of 399.8+/-29.2 ng/g and mean peak blood concentration of 4.88+/-1.6 ng/mL were achieved. It is theorized that enhanced lung retention of tacrolimus is due to lipophilic associations with bronchial tissue and phospholipid surfactants in lung fluid. These findings indicate that tacrolimus dispersion for nebulization can achieve highly localized therapy for lung transplant recipients.


Asunto(s)
Trasplante de Pulmón , Pulmón/metabolismo , Modelos Animales , Nebulizadores y Vaporizadores , Tacrolimus/farmacocinética , Animales , Rechazo de Injerto/metabolismo , Rechazo de Injerto/prevención & control , Pulmón/efectos de los fármacos , Trasplante de Pulmón/métodos , Masculino , Tamaño de la Partícula , Ratas , Ratas Endogámicas Lew , Tacrolimus/administración & dosificación , Tacrolimus/uso terapéutico , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología
6.
Ann Thorac Surg ; 82(2): 460-3; discussion 463-4, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16863744

RESUMEN

BACKGROUND: Associated comorbidities in potential lung transplant recipients may significantly impact operative morbidity and mortality. We undertook this review to specifically study whether patients who underwent associated cardiac procedures either before (as a prerequisite) or during their lung transplantation had different outcomes when compared with the overall cohort of lung transplant recipients. METHODS: A retrospective chart review was performed of all patients who underwent lung transplantation at the University of Texas Health Science Center at San Antonio from January 1994 to June 2004. The records of these patients were analyzed for patient-days on the ventilator, hospital length of stay, operative morbidity and mortality, and long-term survival. The patients were then divided into two groups and compared: patients who had a cardiac intervention either prerequisite to or concurrent with their transplant (group C, n = 13) and patients who did not (group NC [no cardiac intervention], n = 120). RESULTS: Although the median length of stay was longer in group C when compared with group NC, the number of patient-days on the ventilator and the operative morbidity and mortality were similar for both groups. Likewise, overall long-term survival was not significantly different (Kaplan-Meier method, p = 0.70). CONCLUSIONS: Patients who are otherwise deemed to be good candidates for lung transplantation but are found to have an associated cardiac condition that could adversely affect their candidacy may still be considered for transplantation in selected cases if the cardiac abnormality can be addressed either before or during transplantation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Trasplante de Pulmón/mortalidad , Adulto , Anciano , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Ventiladores Mecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA