Asunto(s)
Colon/metabolismo , Diabetes Mellitus/tratamiento farmacológico , Hipoglucemiantes/metabolismo , Hipoglucemiantes/uso terapéutico , Síndrome Metabólico/tratamiento farmacológico , Metformina/metabolismo , Metformina/uso terapéutico , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/metabolismo , Humanos , Hipoglucemiantes/sangre , Absorción Intestinal , Síndrome Metabólico/diagnóstico , Síndrome Metabólico/metabolismo , Metformina/sangre , Proyectos PilotoRESUMEN
Background: The use of a contaminated endoscope may lead to infections due to the transmission of potential pathogens from patient to patient. Methods: Post-reprocessing microbiological surveillance of four duodenoscopes was carried out over a three-year period in the Digestive Endoscopy Unit of an Italian hospital. Sampling of duodenoscopes was performed after the devices have been reprocessed. The initial phase of surveillance involved the contemporary evaluation of the four duodenoscopes; afterwards, microbiological surveillance proceeded at monthly intervals. Results: The initial phase of surveillance revealed that three duodenoscopes presented a high level of contamination with "high-concern" micro-organisms, some of which were multi-drug-resistant. The highest values of contamination regarded the species P. aeruginosa (2500 CFU/duodenoscope), K. pneumoniae (2580 CFU/duodenoscope), and A. baumannii (2600 CFU/duodenoscope). Since the cultures were repeatedly positive on three successive occasions, the contaminated devices were sent to the manufacturer for evaluation. Audits were carried out with the personnel responsible for reprocessing, which was aimed to optimize the procedures used, and subsequently, only one case of non-conformity was found. Conclusions: Our study highlighted both the potential risk of transmitting pathogens through the use of duodenoscopes and the importance of implementing a well-structured system of microbiological surveillance and training programs, in order to reduce the risk of spreading retrograde cholangiopancreatography (ERCP)-associated infections.
Asunto(s)
Infección Hospitalaria/prevención & control , Desinfección/métodos , Duodenoscopios/microbiología , Contaminación de Equipos , Bacterias/aislamiento & purificación , HumanosRESUMEN
BACKGROUND: Compared to emergency surgery, self-expandable metallic stents are effective and safe when used as bridge-to-surgery (BTS) in operable patients with acute colorectal cancer obstruction. In this study, we report data on the new conformable colonic stents. OBJECTIVES: To evaluate clinical effectiveness of conformable stents as BTS in patients with acute colorectal cancer obstruction. DESIGN: This was a retrospective study. SETTINGS: The study was conducted at six Italian Endoscopic Units. PATIENTS: Data about patients with acute malignant colorectal obstruction were collected between 2007 and 2012. MAIN OUTCOME MEASURES: All patients were treated with conformable stents as BTS. Technical success, clinical success, rate of primary anastomosis and colostomy, early and late complications were evaluated. RESULTS: Data about 88 patients (62 males) were reviewed in this study. Conformable SEMS were correctly deployed in 86 out of 88 patients, with resolution of obstruction in all treated patients. Tumor resection with primary anastomosis was possible in all patients. A temporary colostomy was performed in 40. Early complications did not occur. Late complications occurred in 11 patients. Stent migration was significantly higher in patients treated with partially-covered stents compared to the uncovered group (35% vs. 0%, P<0.001). Endoscopical re-intervention was required in 12% of patients. One patient with rectal cancer had an anastomotic dehiscence after surgery and he was successfully treated with endoscopic clipping. One year after surgery, all patients were alive and local recurrence have not been documented. LIMITATIONS: This was a retrospective and uncontrolled study. CONCLUSIONS: Preliminary data from this large case series are encouraging, with a high rate of technical and clinical success and low rate of clinically relevant complications. Partially-covered SEMS should be avoided in order to reduce the risk of endoscopic re-intervention.
Asunto(s)
Neoplasias Colorrectales/complicaciones , Endoscopía del Sistema Digestivo , Obstrucción Intestinal/cirugía , Stents Metálicos Autoexpandibles , Adulto , Anciano , Anciano de 80 o más Años , Aleaciones , Materiales Biocompatibles Revestidos , Femenino , Humanos , Obstrucción Intestinal/etiología , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Estudios RetrospectivosRESUMEN
Inflammation and oxidative stress play a crucial role in the development of colorectal cancer (CRC) and interference with these mechanisms represents a strategy in CRC chemoprevention. Allopurinol, a safe molecular scavenger largely used as antigout agent, has been shown to increase survival of patients with advanced CRC and to reduce CRC incidence in long-term gout users in epidemiologic studies. We conducted a randomized, double-blind, placebo-controlled preoperative trial in subjects with colorectal adenomatous polyps to assess the activity of allopurinol on biomarkers of colorectal carcinogenesis. After complete colonoscopy and biopsy of the index polyp, 73 subjects with colorectal adenomas were assigned to either placebo or one of two doses of allopurinol (100 mg or 300 mg) and treated for four weeks before polyp removal. Change of Ki-67 labeling index in adenomatous tissue was the primary endpoint. Secondary endpoints were the immunohistochemical (IHC) expression of NF-κB, ß-catenin, topoisomerase-II-α, and terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL) in adenomatous polyps and normal adjacent colonic tissue. Compared with placebo, Ki-67 levels were not significantly modulated by allopurinol, whereas ß-catenin and NF-κB expression levels decreased significantly in adenomatous tissue, with a mean change from baseline of -10.6%, 95% confidence interval (CI), -20.5 to -0.7, and -8.1%, 95% CI, -22.7 to 6.5, respectively. NF-κB also decreased significantly in normal adjacent tissue (-16.4%; 95% CI, -29.0 to -3.8). No dose-response relationship was noted, except for NF-κB expression in normal tissue. Allopurinol can inhibit biomarkers of oxidative activation in colon adenomatous polyps and normal adjacent tissue. Further studies should define its potential chemopreventive activity.