Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Opt Express ; 26(8): 9850-9865, 2018 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-29715931

RESUMEN

Recent advances in superresolution fluorescence microscopy have been limited by a belief that surpassing two-fold resolution enhancement of the Rayleigh resolution limit requires stimulated emission or the fluorophore to undergo state transitions. Here we demonstrate a new superresolution method that requires only image acquisitions with a focused illumination spot and computational post-processing. The proposed method utilizes the focused illumination spot to effectively reduce the object size and enhance the object sparsity and consequently increases the resolution and accuracy through nonlinear image post-processing. This method clearly resolves 70nm resolution test objects emitting ~530nm light with a 1.4 numerical aperture (NA) objective, and, when imaging through a 0.5NA objective, exhibits high spatial frequencies comparable to a 1.4NA widefield image, both demonstrating a resolution enhancement above two-fold of the Rayleigh resolution limit. More importantly, we examine how the resolution increases with photon numbers, and show that the more-than-two-fold enhancement is achievable with realistic photon budgets.

2.
Appl Opt ; 54(9): 2244-54, 2015 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-25968507

RESUMEN

The depth of field of an optical system can be extended through a combination of point spread function (PSF) engineering and image processing. A phase mask inserted in the back aperture of the system creates a PSF that is focus-invariant over an extended depth. A digital deconvolution is then used to restore transverse resolution. The application and analysis of this technique to fluorescence microscopy is limited in the literature. In this paper we formalize a microscopy specific imaging model, and experimentally demonstrate a total variation regularized deconvolution approach. Results are compared to the Wiener filter.

3.
Appl Opt ; 52(10): D1-11, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23545977

RESUMEN

Extended depth of field (EDF) microscopy, achieved through computational optics, allows for real-time 3D imaging of live cell dynamics. EDF is achieved through a combination of point spread function engineering and digital image processing. A linear Wiener filter has been conventionally used to deconvolve the image, but it suffers from high frequency noise amplification and processing artifacts. A nonlinear processing scheme is proposed which extends the depth of field while minimizing background noise. The nonlinear filter is generated via a training algorithm and an iterative optimizer. Biological microscope images processed with the nonlinear filter show a significant improvement in image quality and signal-to-noise ratio over the conventional linear filter.


Asunto(s)
Artefactos , Inteligencia Artificial , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Microscopía/métodos , Procesamiento de Señales Asistido por Computador , Algoritmos , Dinámicas no Lineales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
4.
Appl Opt ; 52(14): 3172-7, 2013 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-23669829

RESUMEN

We have demonstrated a one-dimensional array of individually addressable electrowetting tunable liquid lenses that compensate for more than one wave of phase distortion across a wavefront. We report a scheme for piston control using tunable liquid lens arrays in volume-bound cavities that alter the optical path length without affecting the wavefront curvature. Liquid lens arrays with separately tunable focus or phase control hold promise for laser communication systems and adaptive optics.

5.
J Biomed Opt ; 25(5): 1-13, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32441065

RESUMEN

SIGNIFICANCE: It is commonly assumed that using the objective lens to create a tightly focused light spot for illumination provides a twofold resolution improvement over the Rayleigh resolution limit and that resolution improvement is independent of object properties. Nevertheless, such an assumption has not been carefully examined. We examine this assumption by analyzing the performance of two super-resolution methods, known as image scanning microscopy (ISM) and illumination-enhanced sparsity (IES). AIM: We aim to identify the fundamental differences between the two methods, and to provide examples that help researchers determine which method to utilize for different imaging conditions. APPROACH: We input the same image datasets into the two methods and analyze their restorations. In numerical simulations, we design objects of distinct brightness and sparsity levels for imaging. We use biological imaging experiments to verify the simulation results. RESULTS: The resolution of IES often exceeds twice the Rayleigh resolution limit when imaging sparse objects. A decrease in object sparsity negatively affects the resolution improvement in both methods. CONCLUSIONS: The IES method is superior for imaging sparse objects with its main features being bright and small against a dark, large background. For objects that are largely bright with small dark features, the ISM method is favorable.


Asunto(s)
Iluminación , Microscopía , Simulación por Computador
6.
J Biomed Opt ; 13(2): 024020, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18465983

RESUMEN

An extension of Nomarski differential interference contrast microscopy enables isotropic linear phase imaging through the combination of phase shifting, two directions of shear, and Fourier space integration using a modified spiral phase transform. We apply this method to simulated and experimentally acquired images of partially absorptive test objects. A direct comparison of the computationally determined phase to the true object phase demonstrates the capabilities of the method. Simulation results predict and confirm results obtained from experimentally acquired images.


Asunto(s)
Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Microscopía de Contraste de Fase/instrumentación , Refractometría/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/instrumentación
7.
Appl Opt ; 47(1): 15-24, 2008 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18157271

RESUMEN

We introduce a quantitative phase imaging method for homogeneous objects with a bright field transmission microscope by using an amplitude mask and a digital processing algorithm. A known amplitude pattern is imaged on the sample plane containing a thick phase object by placing an amplitude mask in the field diaphragm of the microscope. The phase object distorts the amplitude pattern according to its optical path length (OPL) profile, and the distorted pattern is recorded in a CCD detector. A digital processing algorithm then estimates the object's quantitative OPL profile based on a closed form analytical solution, which is derived using a ray optics model for objects with small OPL gradients.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Iluminación/métodos , Microscopía de Contraste de Fase/métodos , Procesamiento de Señales Asistido por Computador , Microscopía de Contraste de Fase/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA