Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
2.
J Control Release ; 363: 376-388, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37734672

RESUMEN

Polyurethanes are a versatile and highly tunable class of materials that possess unique properties including high tensile strength, abrasion and fatigue resistance, and flexibility at low temperatures. The tunability of polyurethane properties has allowed this class of polymers to become ubiquitous in our daily lives in fields as diverse as apparel, appliances, construction, and the automotive industry. Additionally, polyurethanes with excellent biocompatibility and hemocompatibility can be synthesized, enabling their use as biomaterials in the medical field. The tunable nature of polyurethane biomaterials also makes them excellent candidates as drug delivery vehicles, which is the focus of this review. The fundamental idea we aim to highlight in this article is the structure-property-function relationships found in polyurethane systems. Specifically, the chemical structure of the polymer determines its macroscopic properties and dictates the functions for which it will perform well. By exploring the structure-property-function relationships for polyurethanes, we aim to elucidate the fundamental properties that can be tailored to achieve controlled drug release and empower researchers to design new polyurethane systems for future drug delivery applications.


Asunto(s)
Materiales Biocompatibles , Poliuretanos , Materiales Biocompatibles/química , Poliuretanos/química , Sistemas de Liberación de Medicamentos , Polímeros/química
3.
Biomaterials ; 29(27): 3656-3661, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18556061

RESUMEN

In a previous report we screened a combinatorial peptide library to identify novel ligands that bind with high affinity and specificity to human blood outgrowth endothelial cells (HBOEC). In this study we demonstrate the use of the phage display-selected-HBOEC-specific peptides as a tool to direct and modulate endothelial cell (EC) behavior with a focus on designing functional biomaterials intended for use in cardiovascular applications. First, we ensured that our peptide ligands did not interfere with EC function as tested by proliferation, migration, tube formation, and response to vascular endothelial growth factor. Second, peptides that supported EC function were incorporated into methacrylic terpolymers via chain transfer free radical polymerization. The HBOEC-specific peptide, TPSLEQRTVYAK, when covalently coupled to a terpolymer matrix, retained binding affinity towards HBOEC in a serum-free medium. Under the same binding conditions, the attachment of human umbilical vein endothelial cells (HUVEC) was limited, thus establishing HBOEC specificity. To our knowledge, this is the first report demonstrating specificity in binding to peptide-modified biomaterials of mature EC, i.e., HUVEC, and EC of progenitor origin such as HBOEC. The findings from this work could facilitate the development of autologous cell therapies with which to treat cardiovascular disease.


Asunto(s)
Adhesión Celular , Endotelio Vascular/citología , Polímeros , Secuencia de Aminoácidos , Células Cultivadas , Humanos , Ligandos
4.
Forensic Sci Int Genet ; 35: 113-122, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29727813

RESUMEN

STRmix™ uses several laboratory specific parameters to calibrate the stochastic model for peak heights. These are modelled on empirical observations specific to the instruments and protocol used in the analysis. The extent to which these parameters can be borrowed from laboratories with similar technology and protocols without affecting the accuracy of the system is investigated using a sensitivity analysis. Parameters are first calibrated to a publicly available dataset, after which a large number of likelihood ratios are computed for true contributors and non-contributors using both the calibrated parameters and several borrowed parameters. Differences in the LR caused by using different sets of parameter values are found to be negligible.


Asunto(s)
Repeticiones de Microsatélite , Modelos Estadísticos , Probabilidad , Programas Informáticos , Alelos , Dermatoglifia del ADN , Genética Forense , Técnicas de Genotipaje , Humanos
5.
J Biomater Sci Polym Ed ; 28(10-12): 1051-1069, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28277000

RESUMEN

The field of biomaterials science has exhibited astounding growth during the last half century. This growth can be attributed to a more thorough understanding of cellular behaviours, new mechanistic insights into cell-materials interactions, advances in polymer synthesis, and the development of innovative fabrication techniques. This progress has enabled biomaterials to transition from materials that fill in for damaged or diseased tissues to implants that actively work with biology to aid in the healing process. In this review, we will discuss several of these advances including emerging knowledge on mechanotransduction, the use of substrate topography in modulating cellular behaviour, and the incorporation of bioactive molecules to foster specific cellular adhesion, promote tissue morphogenesis, and enable biologically driven degradation. We will then consider future challenges and directions in the field.


Asunto(s)
Materiales Biocompatibles , Materiales Biomiméticos , Matriz Extracelular/metabolismo , Polímeros , Adhesividad , Animales , Humanos , Péptidos y Proteínas de Señalización Intercelular/metabolismo
6.
Forensic Sci Int Genet ; 23: 226-239, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27235797

RESUMEN

In 2015 the Scientific Working Group on DNA Analysis Methods published the SWGDAM Guidelines for the Validation of Probabilistic Genotyping Systems [1]. STRmix™ is probabilistic genotyping software that employs a continuous model of DNA profile interpretation. This paper describes the developmental validation activities of STRmix™ following the SWGDAM guidelines. It addresses the underlying scientific principles, and the performance of the models with respect to sensitivity, specificity and precision and results of interpretation of casework type samples. This work demonstrates that STRmix™ is suitable for its intended use for the interpretation of single source and mixed DNA profiles.


Asunto(s)
Dermatoglifia del ADN , Genotipo , Repeticiones de Microsatélite , Programas Informáticos , Humanos , Funciones de Verosimilitud , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad
7.
J Biomed Mater Res A ; 74(1): 117-23, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15924302

RESUMEN

Oxidative and hydrolytic biostability assessment was carried out on a novel acrylic material made of hexamethyl methacrylate (HMA), methyl methacrylate (MMA), and methacrylic acid (MAA). To simulate the in vivo microenvironment, solutions of H2O2/CoCl2 and buffered solutions of cholesterol esterase (CE) and phospholipase A2 (PLA) were used. As controls, film specimens were incubated in deionized water. Samples were incubated in these solutions at 37 degrees C for 10 weeks before physical and mechanical properties were evaluated by size exclusion chromatography (SEC), 1H- nuclear magnetic resonance (1H-NMR), acid-base titration, and Instron tensile testing. The results from this study indicate excellent biostability of HMA-MMA-MAA terpolymers and thus their potential for use in biomedical devices for long-term implantation.


Asunto(s)
Resinas Acrílicas/química , Materiales Biocompatibles/química , Resinas Acrílicas/síntesis química , Tampones (Química) , Fenómenos Químicos , Química Física , Cromatografía en Gel , Cobalto/química , Elastómeros , Peróxido de Hidrógeno/química , Hidrólisis , Lisosomas/enzimología , Espectroscopía de Resonancia Magnética , Ensayo de Materiales , Metacrilatos/química , Metilmetacrilato/química , Oxidación-Reducción , Fosfolipasas A/química , Fosfolipasas A2 , Polimetil Metacrilato/síntesis química , Polimetil Metacrilato/química , Esterol Esterasa/química , Resistencia a la Tracción
8.
Forensic Sci Int Genet ; 16: 121-131, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25596557

RESUMEN

Recently there has been a drive for standardisation of DNA profile interpretation within and between different forensic laboratories. The continuous interpretation software STRmix™ has been adopted for use by laboratories in Australia and New Zealand for profile interpretation. Within this paper we examine the concordance in profile interpretation of three crime samples by twenty different analysts across twelve different international laboratories using STRmix™. The three profiles selected for this study exhibited a range of template and complexity. The use of probabilistic software has compelled a level of concordance between different analysts however there remain differences within profile interpretation, particularly with the objective assignment of the number of contributors to profiles.


Asunto(s)
ADN/genética , Probabilidad , Programas Informáticos , Humanos
9.
Biomaterials ; 25(15): 2971-8, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-14967529

RESUMEN

The goal of this research was to design a biomaterial, using acrylic terpolymers, which could support endothelial cells and function in small diameter vascular graft applications. Hexyl methacrylate (HMA) and octyl methacrylate (OMA) were used as comonomers to produce a material with a low glass transition temperature (T(g)). Methacrylic acid (MAA) was used to provide ionic character, and methyl methacrylate (MMA) was selected because of its wide usage in biomedical applications. Cation neutralization was employed to modify the mechanical properties. RGD-based peptide sequences were attached to promote endothelial cell adhesion, because vascular grafts seeded with endothelial cells have fewer problems with thrombosis. The two methods used to incorporate peptide sequences were a chain transfer reaction during polymerization, and a coupling reaction attaching the peptides to carboxyl groups on the polymer after polymerization. The compositions that produced T(g)s of approximately 0 degrees C were 75 mol% OMA and 92 mol% HMA. The Young's modulus of the HMA copolymer was approximately 0.37 MPa, well below the desired value of 0.9 MPa. Likewise, the Young's modulus of approximately 0.50 MPa for the OMA copolymer was also below the desired value. After partial neutralization with sodium cations, the Young's moduli increased to approximately 0.93 and 0.99 MPa, respectively. The chain transfer reaction lowered the molecular weights and mechanical properties of the copolymers, while the coupling reaction method had little effect on these properties. The chain transfer method appears to be a promising one-step method to produce polymers with a wide range of peptide concentrations.


Asunto(s)
Materiales Biocompatibles/química , Metacrilatos/química , Oligopéptidos/química , Prótesis Vascular , Elasticidad , Concentración de Iones de Hidrógeno , Ensayo de Materiales , Polímeros/química , Resistencia a la Tracción , Ingeniería de Tejidos/instrumentación , Ingeniería de Tejidos/métodos , Trasplantes , Viscosidad
10.
Biomaterials ; 23(16): 3359-68, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12099278

RESUMEN

Dendrimer biocides have been shown to be more potent than their small molecule counterparts. In this study, several techniques were utilized to investigate the interactions between quaternary ammonium functionalized poly(propylene imine) dendrimers and bacterial membranes. Both Gram-positive and Gram-negative bacteria were tested. The techniques employed include UV-Vis spectroscopy, differential scanning calorimetry, and bioluminescence. When treated with dendrimer biocides, release of 260nm adsorbing materials from Escherichia coli strains quickly increased and reached a plateau afterwards, while release of 260 nm absorbing materials from Staphylococcus aureus increased monotonically with the concentration due to the difference in cell structures. The different release behavior also correlates with the antimicrobial properties against these two types of bacteria. Bioluminescence experiments using bacteria containing stress-responsive bioluminescent reporter gene fusions provided information suggesting that damage to the cell membranes is the primary mechanism of the antimicrobial action for dendrimer biocides. High concentrations of calcium ions can limit the efficacy of the dendrimer biocides, although the tested concentration range is much higher than most practical applications. Differential scanning calorimetry studies showed at high concentrations that dendrimer biocides formed precipitates with phospholipid vesicles, suggesting a strong interaction with this model of bacterial membrane. These results provide insight about the antibacterial action of dendrimer biocides and establish the basis for their mode of action.


Asunto(s)
Antibacterianos/farmacología , Membrana Celular/química , Bacterias Gramnegativas/química , Bacterias Grampositivas/química , Polipropilenos/química , Polipropilenos/farmacología , Compuestos de Amonio Cuaternario/química , Compuestos de Amonio Cuaternario/farmacología , Staphylococcus aureus/química , Adsorción , Calcio/farmacología , Escherichia coli/química , Escherichia coli/crecimiento & desarrollo , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Gramnegativas/crecimiento & desarrollo , Bacterias Grampositivas/efectos de los fármacos , Bacterias Grampositivas/crecimiento & desarrollo , Luz , Staphylococcus aureus/crecimiento & desarrollo
11.
J Biomed Mater Res A ; 70(2): 265-73, 2004 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-15227671

RESUMEN

Hexyl methacrylate (HMA), methyl methacrylate (MMA), and methacrylic acid (MAA) were used as comonomers to produce a low glass transition temperature material, potentially useful in fabricating a small diameter vascular graft. Because it has been shown that grafts seeded with endothelial cells have better resistance to thrombosis, RGD-based peptide sequences were incorporated into the terpolymer. The two methods used for incorporating peptide sequences were a chain transfer reaction during polymerization, and a coupling reaction between the amine terminus of the peptide and the carboxyl groups of the MAA. Polymers were synthesized using the chain transfer reaction with peptide concentrations ranging from 1.7 to 7.0 micromol/g. Weight-average molecular weights decreased with increasing peptide concentration from 310,000 g/mol for the terpolymer without peptide, to 110,000 g/mol for a peptide concentration of 7.0 micromol/g. As a result, Young's modulus decreased with increasing peptide concentration. Terpolymers with peptides attached through a coupling reaction showed no decrease in molecular weight or mechanical properties. Confocal microscopy showed cells seeded on the RGD surfaces adhered and spread, while terpolymers with RGE sequences showed cells that were rounded and not spreading. Cell density on RGD surfaces increased with increasing peptide concentration up to a bulk peptide concentration of approximately 5 micromol/g and reached a plateau, which indicated the minimum peptide concentration necessary for maximum cell adhesion.


Asunto(s)
Materiales Biocompatibles , Endotelio Vascular/citología , Oligopéptidos , Ácidos Polimetacrílicos , Fenómenos Biomecánicos , Bioprótesis , Prótesis Vascular , Adhesión Celular , Recuento de Células , Células Cultivadas , Humanos , Ensayo de Materiales , Propiedades de Superficie , Ingeniería de Tejidos
12.
Tissue Eng Part A ; 19(9-10): 1113-21, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23167808

RESUMEN

The initial adhesion of human umbilical vein endothelial cells (HUVECs), cord blood endothelial colony-forming cells (ECFCs), and human blood outgrowth endothelial cells (HBOECs) was studied under radial flow conditions. The surface of a variable shear-rate device was either coated with polymer films or covered by synthetic fibers. Spin-coating was applied to produce smooth polymer films, while fibrous scaffolds were generated by electrospinning. The polymer was composed of hexyl methacrylate, methyl methacrylate, poly(ethylene glycol) methacrylate (PEGMA), and CGRGDS peptide. The peptide was incorporated into the polymer system by coupling to an acrylate-PEG-N-hydroxysuccinimide comonomer. A shear-rate-dependent increase of the attached cells with time was observed with all cell types. The adhesion of ECs increased on RGD-linked polymer surfaces compared to polymers without adhesive peptides. The number of attached ECFCs and HBOECs are significantly higher than that of HUVECs within the entire shear-rate range and surfaces examined, especially on RGD-linked polymers at low shear rates. Their superior adhesion ability of endothelial progenitor cells under flow conditions suggests they are a promising source for in vivo seeding of vascular grafts and shows the potential to be used for self-endothelialized implants.


Asunto(s)
Células Endoteliales/citología , Péptidos/química , Polímeros/química , Células Madre/citología , Adhesión Celular/fisiología , Materiales Biocompatibles Revestidos/química , Células Endoteliales de la Vena Umbilical Humana/citología , Humanos , Metacrilatos/química , Estructura Molecular , Oligopéptidos/química , Polietilenglicoles/química
13.
Tissue Eng Part A ; 19(1-2): 79-90, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22834688

RESUMEN

A family of methacrylic terpolymer biomaterials was electrospun into three-dimensional scaffolds. The glass transition temperature of the polymer correlates with the morphology of the resulting scaffold. Glassy materials produce scaffolds with discrete fibers and large pore areas (1531±1365 µm(2)), while rubbery materials produce scaffolds with fused fibers and smaller pore areas (154±110 µm(2)). Three different endothelial-like cell populations were seeded onto these scaffolds under static conditions: human umbilical vein endothelial cells (HUVECs), adult human peripheral blood-derived outgrowth endothelial cells, and umbilical cord blood-derived human blood outgrowth endothelial cells. Cellular behavior depended on both cell type and scaffold topography. Specifically, cord blood-derived outgrowth endothelial cells showed more robust adhesion and growth on all scaffolds in comparison to other cell types as measured by the density of adherent cells, the number of proliferative cells, and the enzymatic activity of the adherent cells. Peripheral blood-derived outgrowth cells exhibited less ability to inhabit the terpolymer interfaces in comparison to their cord blood-derived counterparts. HUVECs also exhibited less of a capacity to colonize the terpolymer interfaces in comparison to the cord blood-derived cells. However, the mature endothelial cells did show scaffold-dependent behavior. Specifically, we observed an increase in their ability to populate the low-porosity scaffolds. All cells maintained an endothelial phenotype after 1 week of culture on the electrospun scaffolds.


Asunto(s)
Vasos Sanguíneos/citología , Vasos Sanguíneos/crecimiento & desarrollo , Electroquímica/métodos , Células Endoteliales/citología , Células Endoteliales/fisiología , Ingeniería de Tejidos/instrumentación , Andamios del Tejido , Células Cultivadas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Metacrilatos/química , Rotación
14.
Acta Biomater ; 8(8): 2899-910, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22503950

RESUMEN

A methacrylic terpolymer system with non-fouling interfacial properties was synthesized by the random copolymerization of hexyl methacrylate, methyl methacrylate and sulfobetaine methacrylate (a monomer bearing a zwitterionic pendant group). Polymers were synthesized from feeds containing 0-15 mol.% of the zwitterion-containing methacrylate. Proton nuclear magnetic resonance verified the incorporation of sulfobetaine methacrylate into the polymer structure. Water absorption studies illustrate that the hydrophilicity of the material increases with increasing zwitterion concentration. The biological properties of the polymer were probed by fibrinogen adsorption, human umbilical vein endothelial cell adhesion and growth, and platelet adhesion. Strong resistance to protein adsorption and cell and platelet attachment was observed on materials synthesized from 15 mol.% sulfobetaine methacrylate. Results were compared to the non-fouling behavior of a PEGylated terpolymer formulation and it was observed that the poly(ethylene glycol)-containing materials were slightly more effective at resisting human umbilical vein endothelial cell adhesion and growth over a 7 day incubation period, but the zwitterion-containing materials were equally effective at resisting fibrinogen adsorption and platelet adhesion. The zwitterion-containing materials were electrospun into three-dimensional random fiber scaffolds. Materials synthesized from 15 mol.% of the zwitterion-containing monomer retained their non-fouling character after fabrication into scaffolds.


Asunto(s)
Betaína/análogos & derivados , Materiales Biocompatibles/síntesis química , Polímeros/síntesis química , Diseño de Prótesis , Adsorción/efectos de los fármacos , Adulto , Betaína/química , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Plaquetas/efectos de los fármacos , Plaquetas/ultraestructura , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Etilaminas , Fibrinógeno/farmacología , Células Endoteliales de la Vena Umbilical Humana/citología , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Masculino , Metacrilatos , Microscopía Fluorescente , Microscopía de Contraste de Fase , Adhesividad Plaquetaria/efectos de los fármacos , Polietilenglicoles/química , Polímeros/química , Polímeros/farmacología
15.
J Biomed Mater Res A ; 100(3): 794-801, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22238050

RESUMEN

A nonfouling peptide grafted polymer was synthesized that can promote endothelial cell (EC) binding. The polymer was composed of hexyl methacrylate, methyl methacrylate, poly(ethylene glycol) methacrylate, and CGRGDS peptide. The peptide was incorporated into the polymer system either by a chain transfer reaction or by coupling to an acrylate-PEG-N-hydroxysuccinimide (NHS) comonomer. The introduction of PEG chains minimizes protein adsorption. Human umbilical vein ECs and endothelial colony forming cells were cultured on these surfaces in short term and long-term studies. A difference in number and morphology of ECs was observed depending on the method of peptide incorporation. Both cell types adhered better to polymer films containing NHS coupled RGD peptide after 2 h even in the presence of albumin but significant cell detachment occurred after 4 days. Polymer solutions were electrospun into fibrous scaffolds. Both nonfouling and peptide binding characteristics were retained after processing.


Asunto(s)
Adhesión Celular/fisiología , Proliferación Celular , Células Endoteliales/fisiología , Oligopéptidos/química , Polietilenglicoles/química , Polímeros/química , Materiales Biocompatibles Revestidos , Células Endoteliales/citología , Células Endoteliales de la Vena Umbilical Humana , Humanos , Ensayo de Materiales , Estructura Molecular , Propiedades de Superficie
17.
J Biomed Mater Res A ; 94(4): 1294-302, 2010 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-20694997

RESUMEN

A terpolymer copolymerized from hexyl methacrylate, methyl methacrylate, and poly(ethylene glycol) methacrylate (PEGMA) was synthesized. Polymers containing 0-25 mol % PEGMA were studied. As the mole fraction of PEGMA in the polymer chains increased, the material becomes more hydrophilic as observed by a decrease in the contact angle of water (81 degrees -68 degrees) and an increase in the equilibrium water absorption (0.7-237 wt %). Furthermore, the material shows nonfouling interfacial properties through resistance to protein adsorption and cellular attachment. A total of 1.2 microg/cm(2) fibrinogen, 18,000 HUVECs/cm(2), and 3,000,000 platelets/cm(2) adsorbed or adhered on non-PEGylated materials, whereas very low amounts of protein or cells were observed on materials containing >or=15 mol % PEGMA. Being thermoplastic, the polymer can be processed postsynthesis. To illustrate the processing capabilities of the material, polymer solutions were electrospun into nonwoven fibrous scaffold, which also retained their nonfouling character.


Asunto(s)
Materiales Biocompatibles/síntesis química , Metacrilatos/síntesis química , Metilmetacrilato/síntesis química , Polietilenglicoles/síntesis química , Adsorción/efectos de los fármacos , Adulto , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Plaquetas/efectos de los fármacos , Plaquetas/ultraestructura , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Células Endoteliales/citología , Células Endoteliales/efectos de los fármacos , Fibrinógeno/metabolismo , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Metacrilatos/química , Metacrilatos/farmacología , Metilmetacrilato/química , Metilmetacrilato/farmacología , Microscopía Fluorescente , Peso Molecular , Adhesividad Plaquetaria/efectos de los fármacos , Polietilenglicoles/química , Polietilenglicoles/farmacología , Venas Umbilicales/citología , Agua/química
18.
J Biomed Mater Res B Appl Biomater ; 92(2): 289-97, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19927330

RESUMEN

A biomaterial system with tunable mechanical properties was synthesized through random copolymerization of hexyl methacrylate, methyl methacrylate, and methacrylic acid. The composition, molecular weight, water absorption, glass transition temperature, and tensile properties of the polymer system were characterized, and the biocompatibility of the material was demonstrated by the ability of human umbilical vein endothelial cells to adhere, proliferate, and spread on the polymer surface. No difference was observed in the behavior of the endothelial cells on the materials regardless of material stiffness.


Asunto(s)
Materiales Biocompatibles/farmacología , Células Endoteliales/efectos de los fármacos , Metacrilatos/farmacología , Absorción , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Cromatografía en Gel , Cristalización , Células Endoteliales/ultraestructura , Humanos , Metacrilatos/síntesis química , Metacrilatos/química , Peso Molecular , Estrés Mecánico , Temperatura , Resistencia a la Tracción , Agua/química
19.
J Biomed Mater Res A ; 94(4): 1195-204, 2010 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-20694986

RESUMEN

A family of methacrylic terpolymer biomaterials was electrospun into three-dimensional fibrous scaffolds. The glass transition temperature of the polymer correlates with the morphology of the resulting scaffold. Glassy materials produce scaffolds with discrete fibers and a high percent void space (84%) while the rubbery materials produced scaffolds with fused fibers and a much lower percent void space (18%). By electrospinning onto a rotating mandrel, aligned fiber scaffolds were fabricated, and it was shown that controlling the rotation speed of the collector allowed for control over the degree of fiber alignment. The electrospinning was shown to not degrade the number average molecular weight of the polymer chains. Human umbilical vein endothelial cells (HUVECs) were seeded onto the electrospun scaffolds under static conditions and it was found that the morphology of the scaffold controlled the cellular proliferation, the metabolic activity, and the morphology of adherent cells. In particular, HUVECs seeded onto low void space scaffolds exhibited enhanced cellular spreading, enzymatic activity, and proliferation. HUVECs seeded onto aligned fiber scaffolds did not demonstrate increased proliferation; however, the cells did organize themselves in the direction of fiber alignment resulting in cells with elongated morphology.


Asunto(s)
Forma de la Célula , Células Endoteliales/citología , Células Endoteliales/metabolismo , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Forma de la Célula/efectos de los fármacos , Módulo de Elasticidad/efectos de los fármacos , Células Endoteliales/efectos de los fármacos , Vidrio/química , Humanos , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Peso Molecular , Polímeros/química , Polímeros/farmacología , Porosidad/efectos de los fármacos , Propiedades de Superficie/efectos de los fármacos , Temperatura de Transición , Venas Umbilicales/citología
20.
J Biomater Sci Polym Ed ; 25(14-15): 1459-60, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25104314
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA